How to Order. Body size. Pressure: 2 MPa. Pressure increase ratio 0 Twice. Symbol. Thread type. Body size

Similar documents
Series VBA1110 to 4200

Booster Regulator/Air Tank

Vacuum Saving Valve Series ZP2V How to Order ZP2V A5 03 Connection thread symbol for the pad Male thread connection Symbol Thread Applicable fixed ori

No.IL02-OM00011-A PRODUCT NAME LOCK UP VALVE. MODEL/ Series IL201 IL211

Industrial Filter. FGD series

30% (SMC comparison) Silencer. New. New. The M5 silencer is now added! The resin silencer is now a more compact size! Series AN.

Related Products: Auto Drain Valve. Model/Specifications. Model

PRODUCT NAME. Main Line Filter. MODEL / Series / Product Number

Air operated valve. VGA342R Series

VBA1110 to 4200 VBA /4 (IN/OUT) 1/4

Doc. No.SYJ300-OMO0002-A. Air Operated Valve PRODUCT NAME. SYJA300 / SYJ3000 Series MODEL/ Series

Series IRV1000/2000/3000

Membrane Air Dryer. IDG1-C06 Series IDG1-C06-P Series

Booster Regulator/Air Tank Increase factory air pressure by up to 4 times! Air-only operation requires no power supply, reduces heat generation, and

Lightweight and Compact Type Floating Joint

5 Port Air Operated Valve

Filter-Regulator-Lubricator

Pressure Relief 3 Port Valve New. Sonic Conductance 45% With the indicator window Step1. With locking holes

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6

IR1000-A IR1010-A IR1020-A

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Series ZFC. Air Suction Filter In-line Type with One-touch Fittings

Moisture Control Tube

Series AMJ. Drain Separator for Vacuum

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

Booster Regulator/Air Tank Increase factory air pressure by up to twice as much! Air-only operation requires no power supply, reduces

435 psi (3.0 MPa) Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. Maximum supply pressure. Set pressure range.

EXH. Specifications. Descriptions. Min. working pressure MPa

Operation Manual Air Saver Unit ASV5000 Series

Doc. No.VFR3000-OMH0005-B. 5 Port Air Operated Valve PRODUCT NAME. VFRA3000, 4000 Series MODEL/ Series

Booster Regulator/Air Tank Increase factory air pressure by up to 4 times! Air-only operation requires no power supply, reduces heat generation, and

kpa or less 5.0. Compressed Air Preparation Filter. AFF/AM/AMD Series CAT.ES30-17B. 1 μm (Current model: 3 μm) 20% 60% 52% 160 mm.

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

SeriesTRBU. Flame Resistant (Equivalent to UL-94 Standard V-0) FR Double Layer Polyurethane Tubing

Filter-Regulator-Lubricator

Direct Operated Precision Regulator Modular Style. Standard Specifications

Series AS-FPQ/AS-FPG. Speed Controller with One-touch Fitting for Clean Room. Speed controllers for clean room use

reduces flow setting time and setting errors!

5.0 MPa Maximum Supply Pressure. New. Stepless control of air pressure proportional to an electrical signal. Series ITVX CAT.

Booster Regulator/Air Tank

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

Pilot Check Valve: Metal Body Type

Precision Regulator IR3120

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

Power Valve: Precision Regulator. High precision, large capacity relief regulator

Low torque Metal seal type Rotary joint

Vacuum Pad with Ejector. Series ZHP

VACUUM REGULATORS CONTENTS

Compressed Air Cleaning Filter Series

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

PVC Quick Drain Valve

F.R.L. Units Precautions 1 Be sure to read this before handling.

Pressure booster. Air Service Units Series Page. General 5.1. Pressure boosters ø Pressure boosters ø 40 c/w air pressure regulator 5.

Parallel Seal Type Slit Valve

Low Friction Cylinders

Process Pump. Self-priming makes priming unnecessary. Air operated type. Air supply port. 5 port solenoid valves. Application Example

5 Port Solenoid Valve

Precision Regulator. Series Model Regulating pressure range Port size Page

Chinese Pressure Vessel Regulations Compliant Product Air Tank for Booster Regulator

Process Pump. Series PAF3000/Series PAF5000

Compact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ

Process Pump PB1000A

ALF400 to 900, ALT-5/-9

Air preparation filter

Booster Regulator/Air Tank

1.0. ISE70/71 Series CAT.ES A. MPa/1.6 MPa. 3-Screen Display High-Precision Digital Pressure Switch. Angled display.

AMG. Model Note) Rated flow (l/min (ANR)) Port size Mass (kg) 1 8, , 3 8. Specifications Fluid. Element life

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type.

Pressure Sensor PSE53#

Unit 24: Applications of Pneumatics and Hydraulics

Increase factory air pressure by up to twice as much! No need for an electrical supply!

Port size. Model Screw-in ZFA10 1/8 ZFA20 1/4 ZFB10 ZFB20 ZFB30 ZFB40 ZFC5 ZFC7

Relays/Valves. Lock-Up Valve. Series IL201/211/220 EMC.IL A-UK

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order

Precision Regulator. IR1000/2000/3000 Series ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV IC ITVH ITVX PVQ VY1 AP100.

Hand Valve Series. Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Control Open/Close for Air Supply.

Process Pump. Flare type (LQ3 fitting) added to the type with nut. Series PAF CAT.ES100-59C. Series PAF5000. Series PAF3000. New

Technical Data Sheet TI-F50 Locking Units series KFH

High Vacuum L Type Valve PRODUCT NAME. XLF Series MODEL/ Series

Change Valve. Push-In Fitting Type Three-way Changeover Valve. Changeover Air Direction by 90. Lightweight and Compact Design.

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Coiling Tube with Twist-Proof Fitting

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

Air Tank for Booster Regulator Compliant with ASME Standards

Process Pump. PAF3000 Series/PAF5000 Series

Oxygen Usage Best Practice Guide

Air Amplifiers & SYSTEMS

Push-In Fitting Type Silencer

F.R.L. Units Precautions 1 Be sure to read this before handling products.

Angle Seat Valve / Air Operated Type

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order. Option. Symbol.

Regulator. Accessory. Description. Symbol. Nil. With bracket. B With round. Port size. (Without limit indicator) With set nut (For panel mount)

Model GPR Primary Pressure Regulating Valve. Instruction Manual

Model GP-1000 Series PRESSURE REDUCING VALVE. Installation & Operation Manual

Transcription:

Booster Regulator Series VBA How to Order VBA 0 series VBA 0 0 Body size /4 Pressure: MPa Pressure increase ratio 0 Twice Thread type Symbol F Thread type G Port size Symbol Port size 0 /4 Symbol VBA0-0 VBA-0 VBA 0A 40A series VBA 40A 04 A 4A 43A Body size 3/8, Air-operated type /, Air-operated type /, Max. operating pressure.6 MPa Pressure increase ratio: Twice VBA0A-03 Port size Symbol Port size 03 3/8 04 / Applicable series VBA A VBA4 A Thread type Symbol Thread type F G VBA40A-04

Booster Regulator Series VBA Standard Specifications Model Fluid Pressure increase ratio Pressure adjustment mechanism Max. flow rate Note 3) (l/min (ANR)) Set pressure range (MPa) Max. supply pressure (MPa) Proof pressure (MPa) Port size (IN, OUT, EXH: 3 locations) Pressure gauge port size (IN, OUT: locations) (G) (Rc) Ambient and fluid temperature ( C) Installation Lubrication Mass (kg) VBA0-0 VBA0A-03 VBA40A-04 VBAA-03 VBA4A-04 VBA-0 VBA43A-04 Compressed air 00 0. to.0 3 /4 /6 0.85 000 0. to.0 0. to.0 to 50 (No freezing) Horizontal Grease (Non-lube) Note ) If the OUT pressure is higher than the set pressure by the handle, excessive pressure is exhausted from the back of the handle. Note ) Please consult SMC for details on the air-operated type (VBAA-03, VBA4A-04) and.6 MPa compatible type (VBA43A-04). Note 3) Flow rate at IN= OUT= 0.5 MPa. The pressure varies depending on the operating conditions. Refer to Flow Characteristic s on page 3 and 4. Twice Handle-operated with relief mechanism Note ) Air-operated Note ) 3/8 /8 3.9 900 000 900 60 0. to.0.5.5 / /8 3/8 /8 / /8 8.6 3.9 8.6 Twice to 4 times Handle-operated with relief mechanism Note ) 0. to.0 3 /4 /6 0.98 Twice 600 0. to.6.4 / /8 8.6

Series VBA VBA0 Flow Characteristics VBA Flow Characteristics P =.0 MPa P = 0.75 MPa P = 0.5 MPa P = 0.4 MPa P = 0.3 MPa P = P P = 0.4 MPa P = 0.3 MPa P = 0.5 MPa P = 0.75 MPa P =.0 MPa P = P Pressure Characteristics Outlet air flow (l/min (ANR)) Inlet pressure: 0.7 MPa Outlet pressure:.0 MPa Flow rate: 0 l/min (ANR) Pressure Characteristics Outlet air flow (l/min (ANR)) Inlet pressure: 0.6 MPa Outlet pressure:.0 MPa Flow rate: 0 l/min (ANR) Set point Set point Inlet pressure (MPa) Charge Characteristics Inlet pressure (MPa) Charge Characteristics Charge time per 0 liters t (s) Charge time per 0 liters t (s) VBA0 Pressure increase ratio P/P The time required to charge tank pressure from 0.8 MPa to.0 MPa at 0.5 MPa supply pressure: P P With the pressure increase ratio from.6 to.0, the charge time of 65 6 = 49 sec. (t) is given by the graph. Then, the charge time (T) for a 0 l tank: Pressure increase ratio P/P 0.8 P.0 P.0 P.5 = =.6 = =.0 = =.0 = = 3.0 0.5 P 0.5 P 0.5 P 0.5 V 0 T = t x = 49 x = 49 (s). 0 0 VBA The time required to charge tank pressure from.0 MPa to.5 MPa at 0.5 MPa supply pressure: With the pressure increase ratio from.0 to 3.0, the charge time of 70 60 = 0 sec. (t) is given by the graph. Then, the charge time (T) for a 0 l tank: V 0 T = t x = 0 x = 0 (s). 0 0

Booster Regulator Series VBA VBA0A Flow Characteristics (VBA0A).0 0.8 0.6 0.4 0. 0 00 400 600 800 000 00 Pressure Characteristics.04.0.0 0.98 0.96 0.94 Charge Characteristics P = 0.4 MPa P = 0.3 MPa Outlet air flow (l/min (ANR)) P = 0.5 MPa 0 0.4 0.5 0.6 0.7 0.8 0.9 Inlet pressure (MPa) Inlet pressure: 0.7 MPa Outlet pressure:.0 MPa Flow rate: 0 l/min (ANR) Set point VBA0A VBA40A Flow Characteristics (VBA40A).0 0.8 0.6 0.4 0. P = 0.3 MPa 0 500 000 500 000 Pressure Characteristics.04.0.0 0.98 0.96 0.94 Outlet air flow (l/min (ANR)) Charge Characteristics P = 0.5 MPa P = 0.4 MPa 0 0.4 0.5 0.6 0.7 0.8 0.9 Inlet pressure (MPa) Inlet pressure: 0.7 MPa Outlet pressure:.0 MPa Flow rate: 0 l/min (ANR) Set point VBA40A Pulsation/ Pulsation is decreased by using tank. If the outlet capacity is undersized, pulsation may occur. VBAT05A Max. pulsation range (MPa) 0. 0.08 0.06 0.04 0.0 0 3 4 5 Capacity (l) VBA0 VBAT0A, VBAT0A, VBAT38A Max. pulsation range (MPa) 0. 0.08 0.06 0.04 0.0 VBAT0 VBAT0 VBAT05 VBAT38 0 0 0 30 38 40 Capacity (l) Charge time per 0 liters t (s) 0 9 8 7 6 5 4 3 VBA0A VBA0A 0...3.4.5.6.7.8.9.0 Pressure increase ratio P/P The time required to charge tank pressure from 0.8 MPa to.0 MPa at 0.5 MPa supply pressure: P P With the pressure increase ratio from.6 to.0, the charge time of.5 3.8 = 7.7 sec. (t) is given by the graph. Then, the charge time (T) for a 00 l tank: Charge time per 0 liters t (s) 0 9 8 7 6 5 4 3 VBA40A VBA40A 0...3.4.5.6.7.8.9.0 Pressure increase ratio P/P 0.8 P.0 P 0.8 P.0 = =.6 = =.0 = =.6 = =.0 0.5 P 0.5 P 0.5 P 0.5 V 00 T = t x = 7.7 x = 77 (s). 0 0 The time required to charge tank pressure from 0.8 MPa to.0 MPa at 0.5 MPa supply pressure: With the pressure increase ratio from.6 to.0, the charge time of 3.5. =.4 sec. (t) is given by the graph. Then, the charge time (T) for a 00 l tank: V 00 T = t x =.4 x = 4 (s). 0 0 VBA0A VBA40A Conditions: Inlet pressure: 0.5 MPa Outlet set pressure: MPa Flow rate: Between 0 and max. flow rate Performance of air tank Alleviates the pulsation generated on the outlet side. Manages supply air to be consumed for short periods of time by storing air through raising the tank pressure.

Series VBA Sizing (Sizing can be achieved by using SMC Energy Saving Program Ver. 3.. Contact your SMC sales representative.) Tc Ts P P3 P ød L Pressure Stroke Upper tank pressure limit P3 Lower tank pressure limit P Necessary supply pressure to cylinder P START Inlet pressure P Time Provide requisite conditions for selection. Necessary conditions: D [mm]: Bore size L [mm]: Cylinder stroke W [mm/s]: Cylinder operating speed C [pc.]: Number of cylinders Tc [s]: Cylinder operating time Ts [s]: Cylinder stop time P [MPa]: Inlet pressure P [MPa] Note ) : Necessary supply pressure to cylinder Example 00 00 00 0.5 30 0.5 0.8 Other conditions: Q [l/min (ANR)]: Necessary air flow amount Qb [l/min (ANR)]: Air flow at outlet of booster regulator Tc [s]: Cylinder stroke time K: Cylinder double-acting:, single-acting: P3 [MPa] Note ) : Pressure to charge in a tank T [s]: Time to charge (Time to charge to P) T [s]: Time to charge (Time to charge to P3) T [s]: Time to charge (Time to charge from P to P3) Z: Number of booster regulators Note ) P is necessary supply pressure to cylinder, and set the pressure to the lower tank pressure limit or less with a regulator. Adjust the pressure taking the maximum operating pressure of equipment in use into consideration. Note ) P3 is output pressure of the booster regulator, which is also the upper pressure limit charged in a tank. Calculate required flow Q. Select booster regulator size from flow characteristics table. Q [l/min (ANR)] = π x D x W x (P + 0.0) x 60 x C 4 x 0 6 0.0 Q = π x 00 x 00 (0.8 + 0.0) x x 60 x = 84 [l/min (ANR)] 4 x 0 6 0.0 VBA A: Qb = 500 [l/min (ANR)] VBA4 A: Qb = 050 [l/min (ANR)] Refer to Flow Characteristics on page 3 and 4. Use the VBA (pressure increase ratio 4) with pressure increase ratio of to 4. Usage of pressure increase ratio below (pressure increase ratio ) is preferred for the VBA0. A stable operation and increased life expectancy will result. Inlet supply pressure volume is approximately twice the volume of the outlet side. {approx. times (pressure increase ratio ), approx. 4 times (pressure increase ratio 4)}. Boost regulator requires that the inlet side volume should be the sum of the flow volume running into the outlet side and the volume exhausted from E port (for driving), because air is the power source. Judgement of flow rate NO: Need no tank The VBA4 A can supply necessary pressure. Avoid pulsation (Max. 0.05 MPa) NO YES The VBA A cannot obtain necessary pressure. YES Obtain the tank volume V. Select the tank with the capacity over V. (Q Qb/) x (Tc x K/60) V [l] = (P3 P) x 9.9 (84 500/) x (0.5 x /60) V = = 5 [l] (.0 0.8) x 9.9 Select the VBAT0, which can be directly connected to the VBA A. Tank part no. VBAT05 VBAT0 VBAT0 VBAT38 Inner volume 5 l 0 l 0 l 38 l Select the tank from table below. Applicable combination model VBA0 VBA0 VBA A VBA A VBA A VBA4 A VBA4 A Calculate time T from charge characteristics table. Refer to Change Characteristics on page 3 and 4. T [s] = ( V ) x 0 T T Z 5 3.7 T = ( ) x = 4. [s] 0 Judgement of charge time T Ts NO Extend stop time Ts up to charge time T or more. NO Increase number of booster regulators (Z) to decrease T. YES YES YES END When running continuously for longer periods of time, confirm the life expectancy. When the life expectancy is shorter than required, select a larger sized booster regulator.

Booster Regulator Series VBA Construction/Principle The IN air passes through the check valve to booster chambers A and B. Meanwhile, air is supplied to drive chamber B via the governor and the switching valve. Then, the air pressure from drive chamber B and booster chamber A are applied to the piston, boosting the air in booster chamber B. As the piston travels, the boosted air is pushed via the check valve to the OUT side. When the piston reaches to the end, the piston causes the switching valve to switch, so that drive chamber B is in the exhaust state and drive chamber A is in the supply state respectively. Then, the piston reverses its movement, this time, the pressures from booster chamber B and drive chamber A boosts the air in booster chamber A and sends it to the OUT side. The process described above is repeated to continuously supply highly pressurized air from the IN to the OUT side. The governor establishes the outlet pressure by handle operation and pressure adjustment in the drive chamber by feeding back the outlet pressure. VBA Drive chamber A Drive chamber B Governor IN (Inlet) Booster chamber B VBA0/0A/40A Booster chamber A Governor Drive chamber A IN (Inlet) Drive chamber B Booster chamber A Piston rod Piston Piston Switching valve E OUT (Outlet) Check valve Switching valve Check valve E OUT Booster chamber B (Outlet) Construction/Replacement Parts VBA 0 VBA0A, 40A q y r w e t q t r w e Replacement Parts/Replacement Part Kits Place an order with the following applicable model number. Model Order no. 0 VBA -0 KT-VBA0- VBA0A-03 KT-VBA0A- VBA40A-04 KT-VBA40A- The kit includes the parts from q to y and a grease pack. No. 3 4 5 6 Model Description Piston seal Governor assembly Check valve Gasket Rod seal Mounting screw Grease pack The grease pack has 0 g of grease. Make sure to refer to the procedure for maintenance. VBA -0 8 0 VBA0A-03 Quantity 4 8 VBA40A-04

Series VBA Dimensions VBA0-0, VBA-0 Gauge port Rc/6 Gauge port Rc/6 OUT IN Pressure gauge (Option) 50 60 ø8 4 x ø5.5 (Mounting hole) IN OUT 0 35 44 08.5 50 3 7 IN port G/4 OUT port G/4 Silencer (Option) AN00-0 40 50 5 60 70 VBA0A-03 300 39 Pressure gauge (Option) 8 IN side gauge port Rc/8 OUT side gauge port Rc/8 76 IN port G3/8 46 43 OUT port G3/8 5 Silencer (Option) 4 53 73 3. 4 x ø 98 EXH port 8 G3/8

Booster Regulator Series VBA Dimensions VBA40A-04 404 IN side gauge port Rc/8 40 Pressure gauge (Option) OUT side gauge port Rc/8 43 5 6.8 6 IN port G/ OUT port G/ 4 8 Silencer (Option) 3 96 6 3. 4 x ø 30 50 G EXH port /

Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of, Warning or Danger. They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC), Japan Industrial Standards (JIS) ) and other safety regulations ). ) ISO 444: Pneumatic fluid power General rules relating to systems. ISO 443: Hydraulic fluid power General rules relating to systems. IEC 6004-: Safety of machinery Electrical equipment of machines. (Part : General requirements) ISO 08-99: Manipulating industrial robots -Safety. JIS B 8370: General rules for pneumatic equipment. JIS B 836: General rules for hydraulic equipment. JIS B 9960-: Safety of machinery Electrical equipment of machines. (Part : General requirements) JIS B 8433-993: Manipulating industrial robots - Safety. etc. ) Labor Safety and Sanitation Law, etc. : Operator error could result in injury or equipment damage. Warning: Operator error could result in serious injury or loss of life. Danger : In extreme conditions, there is a possibility of serious injury or loss of life. Warning. The compatibility of the product is the responsibility of the person who designs the equipment or decides its specifications. Since the product specified here is used under various operating conditions, its compatibility with specific equipment must be decided by the person who designs the equipment or decides its specifications based on necessary analysis and test results. The expected performance and safety assurance of the equipment will be the responsibility of the person who has determined its compatibility with the product. This person should also continuously review all specifications of the product referring to its latest catalog information, with a view to giving due consideration to any possibility of equipment failure when configuring the equipment.. Only personnel with appropriate training should operate machinery and equipment. The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced. 3. Do not service or attempt to remove product and machinery/equipment until safety is confirmed.. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed.. When the product is to be removed, confirm that the safety measures as mentioned above are implemented and the power from any appropriate source is cut, and read and understand the specific product precautions of all relevant products carefully. 3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction. 4. Contact SMC beforehand and take special consideration of safety measures if the product is to be used in any of the following conditions.. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to direct sunlight.. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or other applications unsuitable for the standard specifications described in the product catalog. 3. An application which could have negative effects on people, property, or animals requiring special safety analysis. 4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical pro tective function, and periodical checks to confirm proper operation. Back page

Safety Instructions The product is provided for use in manufacturing industries. The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch. Limited Warranty and Disclaimer/Compliance Requirements The product used is subject to the following Limited Warranty and Disclaimer and Compliance Requirements. Read and accept them before using the product. Limited Warranty and Disclaimer. The warranty period of the product is year in service or.5 years after the product is delivered. 3) Also, the product may have specified durability, running distance or replacement parts. Please consult your nearest sales branch.. For any failure or damage reported within the warranty period which is clearly our responsibility, a replacement product or necessary parts will be provided. This limited warranty applies only to our product independently, and not to any other damage incurred due to the failure of the product. 3. Prior to using SMC products, please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products. 3) Vacuum pads are excluded from this year warranty. A vacuum pad is a consumable part, so it is warranted for a year after it is delivered. Also, even within the warranty period, the wear of a product due to the use of the vacuum pad or failure due to the deterioration of rubber material are not covered by the limited warranty. Compliance Requirements When the product is exported, strictly follow the laws required by the Ministry of Economy, Trade and Industry (Foreign Exchange and Foreign Trade Control Law).

Series VBA Specific Product Precautions Be sure to read this before handling. Refer to the back of pages and for Safety Instructions. For Common Precautions, refer to Precautions for Handling Pneumatic Devices (M-03-E3A). Booster Regulator Specific Product Precautions Warning Design. Warning concerning abnormal outlet pressure If there is a likelihood of causing an outlet pressure drop due to unforeseen circumstances such as equipment malfunction, thus leading to a major problem, take safety measures on the system side. Because the outlet pressure could exceed its set range if there is a large fluctuation in the inlet pressure, leading to unexpected accidents, take safety measures against abnormal pressures. Operate the equipment within its maximum operating pressure and set pressure range.. Residual pressure measures Connect a 3-port valve to the OUT side of the booster regulator if the residual pressure must be released quickly from the outlet pressure side for maintenance, etc. (Refer to the below diagram.) The residual outlet pressure side cannot be released even if the 3-port valve is connected to the IN side because the check valve in the booster regulator will activate.. System configuration The IN port of the booster regulator has metallic mesh to prevent dust from entering the booster regulator. However, it cannot remove dust continuously or separate drainage. Make sure to install a mist separator (AM series) at the inlet side of the booster regulator. The booster regulator has a sliding part inside, and it generates dust. Also, install a cleaning device such as an air filter or a mist separator on the outlet side as necessary. Connect a lubricator to the outlet side, because the accumulated oil in the booster regulator may result in a malfunction.. Exhaust air measures Provide a dedicated pipe to release the exhaust air from each booster regulator. If exhaust air is converged into a pipe, the back pressure that is created could cause improper operation. Depending on the necessity, install a silencer or an exhaust cleaner on the exhaust port of the booster regulator to reduce the exhausting sound. 3. Maintenance space Allow the sufficient space for maintenance and inspection. Selection. Verify the specifications. Consider the operating conditions and operate this product within the specification range that is described in this catalog.. Selection Based on the conditions (pressure, flow rate, takt time, etc.) required for the outlet side of the booster regulator, select the size of the booster regulator in accordance with the selection procedures described in this catalog or model selection program. Use the VBA (pressure increase ratio 4) with pressure increase ratio of to 4. Usage of pressure increase ratio below (pressure increase ratio ) is preferred for the VBA0. A stable operation and increased life expectancy will result. Inlet supply pressure volume is approximately twice the volume of the outlet side. {approx. times (pressure increase ratio ), approx. 4 times (pressure increase ratio 4)}. Booster regulator requires that the inlet side volume should be the sum of the flow volume running into the outlet side and the volume exhausted from E port (for driving), because air is the power source. When running continuously for longer periods of time, confirm the life expectancy. The life expectancy of a booster regulator is dependent upon the operational cycle. Thus, when used for driving cylinders, etc. in the outlet side, life expectancy will be reduced. Make sure the outlet pressure is set more than 0. MPa higher than the inlet pressure. A pressure difference less than 0. MPa makes the operation unstable and may result in malfunction. Mounting. Transporting When transporting this product, hold it lengthwise with both hands. Never hold it by the black handle that protrudes from the center because the handle could become detached from the body, causing the body to fall and leading to injury.. Installation Install this product so that the silver-colored tie-rods and cover are placed horizontally. If mounted vertically, it may result in malfunction. Because the piston cycle vibration is transferred, use the following retaining bolts (VBA: M5; VBA, 4: M0) and tighten them with the specified torque (VBA: 3 N m; VBA, 4: 4 N m). If the transmission of vibration is not preferred, insert an isolating rubber material before installation. The pressure gauge should be mounted with the following torque. R /6 for VBA: 3 to 4 N, R /8: 7 to 9 N

Series VBA Specific Product Precautions Be sure to read this before handling. Refer to the back of pages and for Safety Instructions. For Common Precautions, refer to Precautions for Handling Pneumatic Devices (M-03-E3A). Booster Regulator Specific Product Precautions Piping. Flushing Use an air blower to flush the piping to thoroughly remove any cutting chips, cutting oil, or debris from the piping inside, before connecting them. If they enter the inside of the booster regulator, they could cause the booster regulator to malfunction or its durability could be affected.. Piping size To bring the booster regulator s ability into full play, make sure to match the piping size to the port size. Air Supply. Quality of air source Connect a mist separator to the inlet side near the booster regulator. If the quality of the compressed air is not thoroughly controlled, the booster regulator could malfunction (without being able to boost) or its durability could be affected. If dry air (atmospheric pressure dew point: 7 C or less) is used, the life expectancy may be shortened because dry air will accelerate evaporation of grease inside. Operating Environment. Installation location Do not install this product in an area that is exposed to rainwater or direct sunlight. Do not install in locations influenced by vibrations. If it must be used in such an area due to unavoidable circumstances, please contact SMC beforehand.. Setting the pressure on the handle-operated type If air is supplied to the product in the shipped state, the air will be released. Set the pressure by quickly pulling up on the governor handle, and rotating it in the direction of the arrow (+). There is an upper and lower limit for the handle rotation. If over-rotating the handle even after reaching to the limit, the internal parts may be damaged. If the handle suddenly feels heavy while being turned, stop turning the handle. Once the setting is completed, push the handle down. To decrease the outlet pressure, after the pressure has been set, rotate the handle in the direction of the arrow ( ). The residual air will be released from the area of the handle, due to the relief construction of the governor. To reset the pressure, first reduce the pressure so that it is lower than the desired pressure; then, set it to the desired pressure. Low Handling High. Draining If this product is used with a large amount of drainage accumulated in the filter, mist separator, or the tank, the drainage could flow out, leading to equipment malfunction. Therefore, drain the system once a day. If it is equipped with an autodrain, check its operation once a day. 3. Exhaust Exhausting time from E port may be longer for a booster regulator which is set to switch in longer hour intervals. This is not an abnormal phenomenon. 4. Maintenance Life expectancy varies depending on the quality of air and the operating conditions. As a symptom of the end of life expectancy, it can be found by breathing all the time beneath the handle, or hearing the exhausting sound from booster regulator in 0 to 0 second intervals despite no air consumption in the outlet side. Conduct maintenance earlier than scheduled in such cases. When maintenance is required, confirm the model and serial number of the booster regulator, and please contact SMC for maintenance kit. Maintenance should be carried out according to the specified maintenance procedure by individuals possessing enough knowledge and experiences in maintaining pneumatic equipment. The list of spare parts and kit part number are shown on page 6, and the figure shows the position of the parts.