USER'S GUIDE. Digital Barometers with Serial Output PTB210 Series M210669EN-D

Similar documents
USER'S GUIDE. Digital Barometers with Analog Output PTB210 Series M210670EN-B

PTB210 Series Digital Barometers with Analog Output USER'S GUIDE

PTB210 Series Digital Barometers with Serial Output USER S GUIDE

USER'S GUIDE. Vaisala CARBOCAP Carbon Dioxide Calibrator for the GMP220 series probes GM K220 U421EN-1.1

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

GasSense NDIR User Manual

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

In Vivo Scientific, LLC INSTRUCTION MANUAL

Installation and Operation Manual

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

AMS 2710 PCB pressure sensor module with V output

Precision pressure sensor Basic version Model CPT6020

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

Hand-held Carbon Dioxide Meter GM70 USER'S GUIDE. M010139en-A August 2001

FTC130 Transmitter. Operating Manual

NOVALYNX CORPORATION MODEL BAROMETRIC PRESSURE SENSOR PCB MODEL BAROMETRIC PRESSURE SENSOR IN NEMA ENCLOSURE INSTRUCTION MANUAL

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

RAM 4021 Operation Manual

User s Guide. Pressure Controller for liquid delivery systems

O3 3E 1 F Gas Sensor Module

DPC-30 DPC-100. Reference Manual

RAM 4021-DPX Operation Manual

Additel 761 Automated Pressure Calibrators Selection Guide

Pressure transmitter PASCAL Ci4

Additel 761 Automated Pressure Calibrators Selection Guide

Additel 761 Automated Pressure Calibrators

Hand-held pressure calibrator with integrated pump Model CPH6600

Additel 761 Automated Pressure Calibrators

ASDX Series Silicon Pressure Sensors

METEOR LSR36500 LIGHTING UNDERWATER POOL LIGHT. Operating Instructions

LM6 LEATHER MOISTURE METER

Pneumatic high-pressure controller Model CPC7000

Model SM/PL Series. Calibration Guide. Precision Loads. Anritsu Company 490 Jarvis Drive Morgan Hill, CA USA

RAM Operation Manual

CSA Sample Draw Aspirator Adapter Operator s Manual

Transmitter CS 21 Operation Manual

AMS 6915 Board mount pressure sensor with digital output (I²C)

! Warning, refer to accompanying documents.

Additel 761 Automated Pressure Calibrators

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

YOU MUST READ THIS MANUAL BEFORE USE

DEEPSEA. LED Micro SeaCam POWER & LIGHT. Operator s Manual. Original Instruction Ruffin Road San Diego, CA USA

Additel 780 Series Pressure Controller

Model 4140/4143 General Purpose Thermal Mass Flowmeter

AMS 6916 Board mount pressure sensor with ratiometric analog output

Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor

Ultrasonic Wind Sensor

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

86BSD Backside Digital Output

RK-IR Sample Draw Aspirator Adapter Operator s Manual

High-speed pressure sensor Model CPT6140

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Model FS5001B VA.1. MEMS Mass Flow Sensors ISO 9001 ISO OHSAS 18001

INSTALLATION & MAINTENANCE INSTRUCTIONS

Installation and Operation Manual

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

MODEL 100 NITROGEN INFLATION CART

Model 4040/4043/4045 General Purpose Thermal Mass Flowmeter

210 Series Transmitter with External Electrochemical Sensor

E X R A D I N Spherical Ion Chambers A3. A4 REF DOC #

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

Pneumatic high-pressure controller Model CPC7000

The Univentor 1250 Anaesthesia Unit

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

User s Guide Temperature Sensor Converter TSC-599

Instruction Manual. PLT Series. 1. General Specification. 2. Installation. 3. Wiring. 4. Function. 5. Setting & Calibration

PRESSURE SENSOR - ABSOLUTE (0 TO 700 kpa)

Ultrasonic Wind Sensor

Installation, Operation and Maintenance Manual. TSV Temperature Shut-off Valve SPD Rev. 6 10/07

HLM-2000-TX Gas Transmitter User Manual

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

UNIVERSAL MASK TEST SYSTEM

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

For a similar sensor with o-ring mounting, refer to the 85BSD digital output pressure sensor.

Precision digital pressure gauge Model CPG1000

Modular skylight warranty

BI-680 Online Dissolved Oxygen Controller Instruction Manual

T i m i n g S y s t e m s. RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA (408)

Operation Manual. Pro CO. Carbon Monoxide Analyzer. Rev

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

PT-500 Modbus Series User Manual APG

RK LEL Sample Draw Aspirator Adapter Operator s Manual

ROPV R40 E Series User Manual

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

M104 Series: Digital Manometer: 0.1 % of Full Scale

Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272)

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

Operation Manual. Pro He Alarm TM. Helium Analyzer. Rev 08.17

PLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions

Owner s Manual Humiport 10/20

Technical Data Sheet MF010-O-LC

Digital Vacuum Regulator

SonoMeter 30 Energy Meters

Digital Vacuum Regulator

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

Transcription:

USER'S GUIDE Digital Barometers with Serial Output PTB210 Series M210669EN-D

PUBLISHED BY Vaisala Oyj Phone (int.): +358 9 8949 1 P.O. Box 26 Fax: +358 9 8949 2227 FI-00421 Helsinki Finland Visit our Internet pages at http://www.vaisala.com/ Vaisala 2009 No part of this manual may be reproduced in any form or by any means, electronic or mechanical (including photocopying), nor may its contents be communicated to a third party without prior written permission of the copyright holder. The contents are subject to change without prior notice. Please observe that this manual does not create any legally binding obligations for Vaisala towards the customer or end user. All legally binding commitments and agreements are included exclusively in the applicable supply contract or Conditions of Sale.

Table of Contents CHAPTER 1 GENERAL INFORMATION... 3 Safety... 3 Feedback... 3 Recycling... 4 Trademarks... 4 License Agreement... 4 Warranty... 5 CHAPTER 2 PRODUCT DESCRIPTION... 7 CHAPTER 3 INSTALLATION... 9 Mounting... 9 Static Pressure Head... 10 Connections... 11 RS232C... 11 RS485... 11 RS232C/TTL... 12 CHAPTER 4 OPERATING... 13 General... 13 Settings... 14.BAUD Setting the Baud Rate... 14 Setting the Serial Communication Parameters... 14.ID Setting a Identification Code... 15 Setting Pressure Limits... 15.MPM Measurements per Minute... 16.AVRG Defining the Averaging... 16.PD Setting the Instrument to Power Down State... 16 Operating Commands... 17.P Outputting One Single Message... 17.BP Continuous Outputting... 17.UNIT Selecting a Pressure Unit... 17 Output with or without the Unit... 18.RESET Resetting the Instrument... 18 Setting the Pressure Corrections On/Off... 18.CALD Setting the Calibration Date... 19 Setting the RS485 Terminating Resistor On/Off... 19 Self-Testing... 20.? Basic Information of the Barometer Settings... 20 VAISALA 1

User's Guide CHAPTER 5 CALIBRATION AND ADJUSTMENT...21 Wizard Software...22 Operation...22 CHAPTER 6 TECHNICAL DATA...25 Technical Specification...25 Operating Range...25 Accuracy...25 General...26 Electromagnetic Compatibility...27 List of Figures Dimensions in mm (inches)...28 Figure 1 PTB210 and the Standard Accessories...7 Figure 2 The BAROCAP Pressure Sensor...8 Figure 3 Different Mounting Options of the PTB210...9 Figure 4 Recommended Cable Position...10 List of Tables Table 1 Table 2 Table 3 Connections of the PTB210 Barometer with RS232C Interface...11 Connections of the PTB210 Barometer with RS485/RS232C Interface...11 Connections of the PTB210 Barometer with RS232C/TTL Interface...12 2 M210669EN-D

Chapter 1 General Information CHAPTER 1 GENERAL INFORMATION Safety Throughout the manual, important safety considerations are highlighted as follows: WARNING Warning alerts you to a serious hazard. If you do not read and follow instructions very carefully at this point, there is a risk of injury or even death. CAUTION Caution warns you of a potential hazard. If you do not read and follow instructions carefully at this point, the product could be damaged or important data could be lost. Note highlights important information on using the product. Feedback Vaisala Customer Documentation Team welcomes your comments and suggestions on the quality and usefulness of this publication. If you find errors or have other suggestions for improvement, please indicate the chapter, section, and page number. You can send comments to us by e-mail: manuals@vaisala.com VAISALA 3

User's Guide Recycling Recycle all applicable material. Dispose of batteries and the unit according to statutory regulations. Do not dispose of with regular household refuse. Trademarks BAROCAP is a registered trademark of Vaisala. License Agreement All rights to any software are held by Vaisala or third parties. The customer is allowed to use the software only to the extent that is provided by the applicable supply contract or Software License Agreement. 4 M210669EN-D

Chapter 1 General Information Warranty Vaisala hereby represents and warrants all Products manufactured by Vaisala and sold hereunder to be free from defects in workmanship or material during a period of twelve (12) months from the date of delivery save for products for which a special warranty is given. If any Product proves however to be defective in workmanship or material within the period herein provided Vaisala undertakes to the exclusion of any other remedy to repair or at its own option replace the defective Product or part thereof free of charge and otherwise on the same conditions as for the original Product or part without extension to original warranty time. Defective parts replaced in accordance with this clause shall be placed at the disposal of Vaisala. Vaisala also warrants the quality of all repair and service works performed by its employees to products sold by it. In case the repair or service works should appear inadequate or faulty and should this cause malfunction or nonfunction of the product to which the service was performed Vaisala shall at its free option either repair or have repaired or replace the product in question. The working hours used by employees of Vaisala for such repair or replacement shall be free of charge to the client. This service warranty shall be valid for a period of six (6) months from the date the service measures were completed. This warranty is however subject to following conditions: a) A substantiated written claim as to any alleged defects shall have been received by Vaisala within thirty (30) days after the defect or fault became known or occurred, and b) The allegedly defective Product or part shall, should Vaisala so require, be sent to the works of Vaisala or to such other place as Vaisala may indicate in writing, freight and insurance prepaid and properly packed and labelled, unless Vaisala agrees to inspect and repair the Product or replace it on site. This warranty does not however apply when the defect has been caused through a) normal wear and tear or accident; b) misuse or other unsuitable or unauthorized use of the Product or negligence or error in storing, maintaining or in handling the Product or any equipment thereof; c) wrong installation or assembly or failure to service the Product or otherwise follow Vaisala's service instructions including any repairs or installation or assembly or service made by unauthorized personnel not approved by Vaisala or replacements with parts not manufactured or supplied by Vaisala; d) modifications or changes of the Product as well as any adding to it without Vaisala's prior authorization; e) other factors depending on the Customer or a third party. Notwithstanding the aforesaid Vaisala's liability under this clause shall not apply to any defects arising out of materials, designs or instructions provided by the Customer. This warranty is expressly in lieu of and excludes all other conditions, warranties and liabilities, express or implied, whether under law, statute or otherwise, including without limitation any implied warranties of merchantability or fitness for a particular purpose and all other obligations and liabilities of Vaisala or its representatives with respect to any defect or deficiency applicable to or resulting directly or indirectly from the Products supplied hereunder, which obligations and liabilities are hereby expressly cancelled and waived. Vaisala's liability shall under no circumstances exceed the invoice price of any Product for which a warranty claim is made, nor shall Vaisala in any circumstances be liable for lost profits or other consequential loss whether direct or indirect or for special damages. VAISALA 5

User's Guide This page intentionally left blank. 6 M210669EN-D

Chapter 2 Product description CHAPTER 2 PRODUCT DESCRIPTION The PTB210 series digital barometers are designed for various pressure ranges. The barometers with serial output are available with two basic configurations: serial output for 500... 1100 hpa and 50... 1100 hpa. The PTB210 barometers are also available with an analog output with different scalings. The PTB210 series barometers offer an excellent solution for outdoor installations. They operate in a wide temperature range. The housing of the barometer electronics provides an IP65 standardized protection against sprayed water. The rugged corrosion-resistant housing in combination with the small size facilitates easy installation and a long lifetime for the barometer. All the barometers are digitally adjusted and calibrated by using electronic working standards. For the pressure range 500... 1100 hpa also a higher accuracy barometer is available. This manual gives the instructions for the use of PTB210 barometers with the digital output. Fixing screw (2 pcs) PTB210 barometer Rail fastening clip Pressure fitting Attachment plate Figure 1 PTB210 and the Standard Accessories VAISALA 7

User's Guide The PTB210 barometers incorporate the BAROCAP silicon capacitive absolute pressure sensor developed by Vaisala. The sensor features excellent hysteresis and repeatability characteristics and has an outstanding temperature and long-term stability. Thin film metallization Silicon diaphragm Silicon Glass Vacuum gap Silicon Figure 2 The BAROCAP Pressure Sensor The BAROCAP pressure sensor consists of two layers of single crystal silicon having a layer of glass between them. The thinner silicon layer creates an integrated vacuum reference chamber, and forms a pressure-sensitive silicon diaphragm. The thicker silicon layer is the rigid base plate of the sensor, and it is clad with a glass dielectric. Thin film metallization has been deposited to form a capacitor electrode inside the vacuum reference chamber. The other electrode is the pressure-sensitive silicon diaphragm. The coefficients of thermal expansion of silicon and glass materials used in the BAROCAP pressure sensor are carefully matched together to minimize the temperature dependence, and to maximize the long-term stability. The BAROCAP pressure sensor is designed to achieve zero temperature dependence at 1000 hpa, and its long-term stability has been maximized by thermal ageing at an elevated temperature. 8 M210669EN-D

Chapter 3 Installation CHAPTER 3 INSTALLATION Mounting Due to the compact design of the PTB210, all you need to do is to mount the instrument, and to connect the wires. Use one of the following three mounting options. - Remove the pressure fitting, and place the barometer on a desired structure. Then, fix it with the slot headed screws the O-ring sealing the attachment (A). - Fix the supplied attachment plate to a desired place. Then, attach the barometer on the plate with the screws supplied (B). - The PTB210 can also be placed to a standard rail (DIN 35) by using the attachment plate and clip (B). Fasten the clip and barometer to the plate with the screws supplied. Finally, attach the clip to the rail. A B Figure 3 Different Mounting Options of the PTB210 Always place the barometer so that the pressure fitting is downwards. VAISALA 9

User's Guide Check that the cable is not taken upwards from the barometer. This is to prevent water flowing along the cable, and gathering close to the feed-through. Figure 4 Recommended Cable Position The IP65-classified housing enables the barometer to be mounted outdoors without any additional protection. However, please take care that rainwater cannot plug the open pressure fitting. In such conditions, it is recommended to connect a piece of a tube with inner diameter of 4 mm or more to the fitting. It is also possible to use a static pressure head, SPH10/20, which protects the pressure channel from rain, and minimizes the effect of wind. Static Pressure Head Please note that the pressure fitting supplied with the transmitter is not a static pressure head, and that the transmitter cannot be used successfully as such in turbulent or high-speed static wind conditions. In demanding wind conditions, it is recommended to use Vaisala's static pressure head, SPH10/20, to which the PTB210 digital barometers can be directly integrated. This combination provides for accurate measurement in all wind conditions. 10 M210669EN-D

Chapter 3 Installation Connections There are three different serial output interfaces available with the PTB210 digital barometers: RS232C, RS485/232C, and RS232C/TTL. The connections depend on the output protocol in use. In following tables there are presented the connections of these output interfaces. RS232C Table 1 Wire color Grey Green Blue Pink Brown White Yellow Connections of the PTB210 Barometer with RS232C Interface. Signal RX TX Ground Supply voltage (5... 28 VDC) not connected not connected External power control (TTL level: 1 = 5 V= off, 0 = 0 V= on) It is recommended to isolate the free wire ends. RS485 Table 2 Connections of the PTB210 Barometer with RS485/RS232C Interface Wire color Signal Grey RX (with RS232C) Green TX (with RS232C) Blue Ground Pink Supply voltage (8... 18 VDC) Brown RS485 - White RS485 + Yellow External power control (TTL level: 1 = off, 0 = on) See also chapter "Setting the RS485 Terminating Resistor On/Off "on page 19. The two output protocols cannot be used simultaneously. Connect either RX/TX or RS485 wires. It is recommended to isolate the free wire ends. VAISALA 11

User's Guide RS232C/TTL Table 3 Wire color Grey Green Blue Pink Brown White Yellow Connections of the PTB210 Barometer with RS232C/TTL Interface Signal RX (with RS232C) TX (with RS232C) Ground Supply voltage (5... 28 VDC) RXD (TTL level) TXD (TTL level) External power control (TTL level: 1 = off, 0 = on) The two output protocols cannot be used simultaneously. Connect either RX/TX or RXD/TXD wires. It is recommended to isolate the free wire ends. 12 M210669EN-D

Chapter 4 Operating CHAPTER 4 OPERATING General The PTB210 series barometers can be operated through a serial line by using suitable terminal software like Windows Hyper Terminal, and the commands given in following pages. The format of the commands is:.zzz.xxx<cr>, where ZZZ defines an event and xxx is the given value of a parameter. When there are several barometers on same line, it is necessary to use an instrument-specific identification code in front of the command e.g. 123.BAUD.9600<cr>, where 123 is the ID-code (see page 15). The code directs the command to that specific instrument. This prevents any inconsistency between the barometers and the host system. A barometer reacts only to a command with its ID, or the one that is given without the code. Common setting commands can be given without the ID code i.e. settings are given to all barometers simultaneously. The barometer does not echo the given commands nor confirm the new settings by echoing them. However, the settings can be checked with the command?<cr>. VAISALA 13

User's Guide Settings.BAUD Setting the Baud Rate.BAUD.xxxx<cr> xxxx = baud rate (1200... 19200) Example:.BAUD.9600<cr>.RESET<cr> (commands invisible) To activate the new settings, please remember to reset the barometer with the command.reset<cr> Setting the Serial Communication Parameters The following parameter combinations are available with the PTB210 digital barometers. The factory setting for the parameters is E71. or or.e71<cr>.o71<cr>.n81<cr> The command sets the serial communication parameters of either a single barometer or all the barometers in. To activate the new settings, please remember to reset the barometer with the command.reset<cr> 14 M210669EN-D

Chapter 4 Operating.ID Setting a Identification Code.ID.xxx<cr> xxx = identification code (max. 15 characters) If there are several barometers on same line, it is necessary to use the ID -code in order to direct the command for a specific instrument. As default, the ID code is 0. When several barometers will be used on same line, the codes have to be set before hand separately for each instrument. The barometer handles the ID-code as characters i.e. 0001, 01 and 1 are different codes Setting Pressure Limits If desired a lower and a higher pressure limits can be given to the barometer. The limits can be used to define e.g. the calibrated pressure range to a host system..pmin.xxxx<cr> xxxx = lower pressure limit (0... 15000 hpa) If current pressure is under the limit, the barometer outputs ****.** in stead of the pressure reading..pmax.xxxx<cr> xxxx = higher pressure limit If current pressure is over the limit, the barometer outputs ****.** in stead of the pressure reading To activate the new settings, please remember to reset the barometer with the command.reset<cr> VAISALA 15

User's Guide.MPM Measurements per Minute.MPM.xxx<cr> xxx = number of measurements per minute (6... 4200) The command sets the number of measurements performed in one minute. As default, the MPM is 60. 60 min -1 = 1 s -1 = 1 measurement per second To activate the new setting, please remember to reset the barometer with the command.reset<cr>.avrg Defining the Averaging.AVRG.xxx<cr> xxx = the number of measurements of which the average is calculated (0... 255). As default, the AVRG is 0. The command sets the number of measurement points that are used for the calculating an average pressure reading. However, this is not a moving average. An example: if the number of measurements per minute is set to 30, and the averaging to 5, the pressure reading is updated every 10 seconds. To activate the new setting, please remember to reset the barometer with the command.reset<cr>.pd Setting the Instrument to Power Down State.PD<cr> The command sets the barometer to power down state in which it does not measure the pressure. The instrument is re-activated by pressing the enter-key. After this, the barometer settles in a half of a second. Then any command can be given to the barometer. 16 M210669EN-D

Chapter 4 Operating Operating Commands.P Outputting One Single Message.P<cr> The command outputs the latest multi-point corrected pressure reading with two decimals..p<cr> 1012.99 (command invisible).bp Continuous Outputting.BP<cr> The command outputs the MPC corrected pressure reading continuously. The output interval depends on the measurement rate and the averaging. The outputting is stopped by pressing enter key (<cr>)..p<cr> 997.99 998.01 998.01... 998.02 <cr> (command invisible) (command invisible).unit Selecting a Pressure Unit.UNIT.x<cr> x = 0 (hpa) 6 (kpa) 1 (mbar) 7 (Pa) 2 (inhg) 8 (mmh 2 O) 3 (psia) 9 (inh 2 O) 4 (torr) 10 (bar) 5 (mmhg As default, the unit is 0. To activate the new setting, please remember to reset the barometer with the command.reset<cr> VAISALA 17

User's Guide Output with or without the Unit.FORM.0<cr> The command cancels the outputting of the unit after pressure reading. This is also the factory setting for the output format. 1017.61.FORM.1<cr> The command adds the unit to the outputting. The standard output field is for 6 characters. The first character is always a space. 1017.61 hpa To activate the new setting, please remember to reset the barometer with the command.reset<cr>.reset Resetting the Instrument.RESET<cr> The command resets the barometer and activates the setting changes. Setting the Pressure Corrections On/Off These commands are used to set multi-point corrections either on or off. See also the chapter Calibration and Adjustment on page 21..MPCON<cr> The command activates the multi-point corrections..mpcoff<cr> The command deactivates the multi-point corrections. To activate the new setting, please remember to reset the barometer with the command.reset<cr> 18 M210669EN-D

Chapter 4 Operating.CALD Setting the Calibration Date With this command, the last calibration date can be stored in the memory of the barometer..cald.xxx xxx = calibration date; max. 15 characters Example:.CALD.991015<cr> Setting the RS485 Terminating Resistor On/Off The PTB210 series barometers have a built-in RS485 terminating resistor, which is set, as default, OFF. The resistor can be set either ON or OFF with the.roff/.roff commands. If the barometer is in the end of the serial line, the resistor should be set ON, especially, when long cables are used. In case several barometers are connected to same line, only the resistor of the last one is set ON, with the others it should be OFF. This prevents formation of excessive load on the line. The maximum amount of barometers on same line is 32. At the end of the serial bus there must be a PTB210 barometer, a dynamic line adapter or a line master (see figure below). HOST COMPUTER RX/TX HI LO HI LO HI LO RX/TX RX/TX PTB210... HI LO RX/TX... DYNAMIC LINE TERMINATION REQUIRED IF NO DEVICE AT THE END OF THE BUS 120R 33nF VAISALA 19

User's Guide.RON<cr> The.RON command sets the terminating resistor on..roff<cr> The.ROFF command sets the terminating resistor off. Self-Testing.? Basic Information of the Barometer Settings.?<cr> The command lists the basic information of the barometer settings. The following example shows also the factory settings for 50 1100 hpa model..?<cr> (command not visible) PTB210 Ver 1.0 CAL DATE :1999-06-10 ID CODE :10 SERIAL NUMBER :T00100004 MULTIPOINT CORR:ON MEAS PER MINUTE: 60 AVERAGING : 0 PRESSURE UNIT : hpa Pressure Min...Max: 500 1100 (50 1100 for model 50 1100) LOW CURRENT MODE RS485 RESISTOR OFF 20 M210669EN-D

Chapter 5 Calibration and Adjustment CHAPTER 5 CALIBRATION AND ADJUSTMENT The PTB210 series digital barometers can be fine adjusted and calibrated against pressure standards that have high accuracy and stability as well as known traceability to international standards. For the Class A barometers, standards with uncertainty of 70 ppm ( 2 standard deviation value) or better should be used. For the Class B barometers, electronic working standards with uncertainty of 150 ppm are recommended. Calibration is considered not to involve any adjustments. The pressure readjustment of a PTB210 series digital barometer is performed by deactivating first the multi-point corrections using MPCOFF command. All fine adjustments are then deactivated. By comparing the output to a reference, the user can define the corrections required for readjustment. It is advisable to write down the previous multi-point corrections so that they will not be lost by mistake. The corrections are given by using the Wizard software; available for download at http://www.vaisala.com/ptb210wizard/. When the new multi-point corrections have been entered to the barometer, the corrections are activated either with the Wizard or with the MPCON command. Finally, the barometer is calibrated to verify its real accuracy. VAISALA 21

User's Guide Wizard Software The user-friendly Wizard software is designed to work in WIN3.X, WIN95, and NT environment. The multi-point pressure corrections for the PTB210 barometers are given through the serial line by using this program. Moreover, a few settings of the instrument can be changed using the Wizard. Operation First, check that the terminal software in use is closed before operating the Wizard. The Wizard uses either RS232 or RS485 interface. If the TTL level interface is used, disconnect the RXD/TXD wires and then connect the RX/TX wires (see page 12). To start the Wizard program in NT: 1. Double-click the My Computer icon. 2. Double-click the drive that contains the file. 3. To start the program, double-click the WIZARD.EXE-file. OR To start a program by using the Run command in NT 1. Click Start, and then click Run. 2. In the Open box, type the location and name of the program you want to start. Alternatively, browse the location, and choose the name of the program (WIZARD.EXE). Then, click OK. 22 M210669EN-D

Chapter 5 Calibration and Adjustment 1. Choose the COM port in use from the file menu. 2. To open the connection click the Read PTB210-button. 3. Give reference pressure values and the corresponding corrections. Calculate the corrections according to the following equation. The settings on left-hand side can also be changed. corr P reference P measured (1) VAISALA 23

User's Guide The values are given in hpa: the reference value as whole number, and the correction with two decimals. 4. To save the new corrections, click the Write PTB210-button. 5. The program then asks a password. As default, no password exists. Just click OK. The password can be used to prevent saving of any new corrections without entering it. To give a password, click the Change-button. 6. Enter a new password and confirm by re-entering it. Remember to set the MPC corrections on after given them. 24 M210669EN-D

Chapter 6 Technical Data CHAPTER 6 TECHNICAL DATA Technical Specification Operating Range Pressure range Operating temperature range Humidity range Accuracy 500... 1100 hpa 50... 1100 hpa -40... +60 C non condensing 500 1100 hpa Class A ClassB Non linearity* 0.10 hpa 0.15 hpa Hysteresis* 0.05 hpa 0.05 hpa Repeatability* 0.05 hpa 0.05 hpa Calibration uncertainty** ± 0.07 hpa ± 0.15 hpa Total accuracy (20 C)*** 0.15 hpa 0.20 hpa Temperature dependence (-40... +60 C)**** ± 0.20 hpa ± 0.20 hpa Total accuracy*** (-40... +60 C) 0.25 hpa 0.30 hpa Long term stability 0.10 hpa/year 0.10 hpa/year 50 1100 hpa Non linearity* 0.20 hpa Hysteresis* 0.10 hpa Repeatability* 0.10 hpa Calibration uncertainty** ± 0.20 hpa Total accuracy (20 C)*** 0.35 hpa Temperature dependence (-40... +60 C)**** ± 0.40 hpa Total accuracy*** (-40... +60 C) 0.50 hpa Long term stability ± 0.20 hpa/year VAISALA 25

User's Guide * Defined as the ±2 standard deviation limits of end-point non-linearity, hysteresis error or repeatability error. ** Defined as ±2 standard deviation limits of inaccuracy of the working standard including traceability to NIST. *** Defined as the root sum of the squares (RSS) of end-point non-linearity, hysteresis error, repeatability error and calibration uncertainty at room temperature. **** Defined as ±2 standard deviation limits of temperature dependence over the operating temperature range. General Supply voltage with RS485 with RS232C with RS232C/TTL 8... 18 VDC 5... 28 VDC 5... 28 VDC reverse polarity protected Current consumption normal mode < 15 ma (factory setting) power down mode < 0.8 ma shutdown mode 0.2 ma Shutdown ON/OFF Settling time at power up 2 s Serial I/O (factory setting *) RS232C RS232C /TTL (optional) RS485, non isolated (optional) parity none, even*, odd data bits 7*, 8 stop bits 1*, 2 Baud rate 1200, 2400, 4800, 9600*, 19200 Response time 1 s* Resolution Max. pressure Pressure connector Pressure fitting Housing electronics sensor Housing material Pressure connector Pressure fitting Supply/output cable length Weight Instrument Cable 0.01 hpa (1 measurement/s) 0.05 hpa (20 measurements/s) 5 000 hpa abs. M5 (10-32) internal thread barbed fitting for 1/8" I.D. tubing IP65 IP53 PC plastic M5 (10-32) internal thread barbed fitting for 1/8" I.D. tubing 1, 2, 3, 5, or 10 m 110 g 28 g/m 26 M210669EN-D

Chapter 6 Technical Data Electromagnetic Compatibility Electromagnetic compatability EN61326-1:1997+ Am1:1998 + Am2:2001 Generic environment [CISPR16/22 class B, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6] VAISALA 27

User's Guide Dimensions in mm (inches) 32 (1.26) 16 (0.63) 120 (4.72) 122.5 (4.82) 50 (1.97) 28 M210669EN-D

10 (0.39) Chapter 6 Technical Data 50.40 (1.98) 40 (1.57) 2 (0.08) 30 (1.81) 5x45 (0.2x45 ) M3 14.20 (0.56) 19 (0.75) 4.50 (0.18) 37 (1.46) 60 (2.36) M3 14x45 (0.55x45 ) ø15 (0.59) 21 (0.83) 50 (1.97) M3 VAISALA 29

www.vaisala.com *M210669EN*