Sensor FL1000 Instruction manual

Similar documents
Target disk flowmeter Series DP. Instructions manual DP65 DP500. R-MI-DP Rev.: 4 English version

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Integral type Differential pressure flowmeter VNT Series

TD45 Thermodynamic Steam Trap Installation and Maintenance Instructions

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks

SCA Series Inverted Bucket Steam Traps

Installation & Operation Manual Proven Quality since 1892

Telefon (+45) Telefax (+45)

3-PIECE BALL VALVE, 3600 PSI/ PN 248, WITH ISO DIRECT MOUNTING PAD 306M SERIES/ PED Category II

Horizontal Bladder Tanks

Flow controller Type ED/CCB311 Instruction manual

Vertical Bladder Tanks

Serie 06-M6. Swing wafer check valve. made in. Application fields. Check valves E U R O P E WATER CONDITIONING INDUSTRY

Model MTB-ASME Horizontal Bladder Tanks

FPD175 Compact orifice carrier assembly

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Accessories. Flexible Compensators FN & ESA FLEX & INOXESTENS (E5603 rev /03/2015)

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

Magnetic level switch type MR783 Instruction Manual

3/8" Dr. Air Butterfly Impact Wrench

DCV10 Stainless Steel Disc Check Valve for use with Condensate Pumps

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E

vacon nx ac drives hxm120 cooling unit, ss-piping commissioning and maintenance manual

vacon nx ac drives hxl040 cooling unit, ss-piping commissioning and maintenance manual

Flowmeter. Original operating manual DFM

Engineering Data Sheet

Spilt body Flange ball valve. TC-205MFF-PN1640 User Manual English Version. Document No: TC-205MFF-PN1640.Ur-manual. Date: 2007/04/2617. Version: 1.

M A B MAB INFLATABLE GASKET SLIDE VALVES SERIES TSV FOR POWDERED AND GRANULAR SOLID MATERIALS

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

Differential Pressure Transmiter

Serie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

AVS32 Stainless Steel Air Vent for Steam Systems Installation and Maintenance Instructions

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

BGA158 Series CE Approved Class A Shutoff Gas Valve

Operating Instructions. Ball valve fitting according to ZB For pressure transmitter VEGABAR 82. Document ID: 50027

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

TBV OPERATION AND MAINTENANCE MANUAL SERIES 2800: FLANGED BALL VALVE. For technical questions, please contact the following:

CA10S, CA14 and CA14S Air and Gas Traps

WHEATLEY Series 500 Swing Check Valve

BGA158 Series CE Approved Class B Shutoff Gas Valve

HM and HM34 Inverted Bucket Steam Traps Installation and Maintenance Instructions

INSTRUCTION MANUAL Pressure Relief Device LPT

Pressure Reducing Valve DMV 755

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Installation / Operation / Maintenance Manual KLINGER Reflex Level Gauge Type R 25

HYDRAULIC CONTROL VALVES

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

INSTRUCTIONS AND MAINTENANCE MANUAL SERIES: RT

Operating instruction

3" 24" 80A 600A DN80 DN600 Body size The largest size manufactured : 60" (1500A) Disc form Damper type Trim materials Trim treatment

Pressure Reducing Valve DMV 750

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Type Type Differential Pressure Regulators (opening)

SEries 29 Hydrant valves installation, operation & maintenance manual

Electro-Magnetic Flowmeters Electromagnetic Sensor

BSA6T and BSA64T Stainless Steel Bellows Sealed Stop Valves Installation and Maintenance Instructions

Two-port valves, male threaded, PN25

Media-Isolated Mag Plus Probe Low Pressure-ISO Kit

L21S/SR/ST Glass Level Gauges

ROTATING DISK VALVES INSTALLATION AND MAINTENANCE 1. SCOPE 3 2. INFORMATION ON USAGE 3 3. VALVE TYPES 3 4. OPERATORS 5 5. VALVE CONSTRUCTION 6

Pressure Reducing Valve DMV 750 set range: bar

Manual Actuated Boiler Blowdown Valves

Dual Solenoid Gas Valve Installation

Pressure Reducing Valve DMV 755 set range: 1,0-9,0 bar

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

Ref GAS WAFER BUTTERFLY VALVE. Model/Ref:

DelVal Flow Controls Private limited

SV5 Safety Valve Installation and Maintenance Instructions

Centrifugal Gas Separator ZGA. Operating Manual. Dimensions, weights and other technical data are subject to changes.

INSTALLATION, OPERATION & MAINTENANCE MANUAL

Bray/ VAAS O-Ported Series Knife Gate Valve 770/780 Series Operation and Maintenance Manual

BGA158, BGA171 and BGA110 Series Shutoff Gas Valve

DCV1, DCV3 and DCV3LT Disc Check Valves Installation and Maintenance Instructions

New! ProFlow. Sliding Vane Meters DN (½ - 2 ) _ 142. Product Bulletin

Materials : Carbon steel ASTM A216 WCB

ABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter

ITT RICHTER CHEMIE-TECHNIK

FLOW CONDITIONER «EMIS-VEKTA 1200» EMIS-VEKTA 1200.UM.PS v User manual Passport. «EMIS», CJSC Russia, Chelyabinsk

Pressure Reducing Valve

FTGS14 Ball Float Steam Trap DN15 (½") to DN25 (1")

PV4 and PV6 Piston Valves

Spirax SafeBloc TM DBB3 Double Block and Bleed Bellows Sealed Stop Valve. 1. Safety information. 2. General product information. 3.

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron EN GJL 250 body. Reinforced lug for DN200 :

KENNEDY VALVE OPERATION & MAINTENANCE MANUAL

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

Pilot Operated Pressure Reducing Valve

Installation Instructions For Flat Seated Bolted Type RAH Series Disk Holders

Materials : Stainless steel ASTM A351 CF8M

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

PROPORTIONAL SAFETY VALVE zarmak

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914

GM Series Dual-Block Multi-Function Gas Control Valves

ATS430 turbidity sensor Retractable insertion assembly

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas

Transcription:

Apator Powogaz S.A., ul. Klemensa Janickiego 23/25, 60-542 Poznań, Poland tel.: +48 61 84 18 101, fax: +48 61 84 70 192 www.apator.com Sensor FL1000 Instruction manual ISO 9001 PN-N-18001 ISO 14001

INTRODUCTION 3 START UP AND MAINTNANC OF TH INSTRUMNTS 3 SAFTY 4 GNRAL INFORMATION ON TH SNSORS INSTALLATION 4 OVRALL DIMNSIONS 5 SHRWDNSS AND PRCAUTIONS 6 OPRATING TMPRATURS 6 LCTRICAL CONNCTIONS OF SNSOR TO CONVRTR 7 GROUNDING INSTRUCTIONS 8 TORQUS (NM) FOR WAFR SNSOR S BOLTS 9 NOTS FOR PD DIRCTIV FOR SNSOR 10

INTRODUCTION This manual is integral part of the product. Read carefully the instructions contained since it contains important indications for the safety of use and of maintenance. The technical information and the relative products of this manual could be modified without any previous notice. The flow meter must be used for the use it has been built for. The improper use, possible tampering of the instrument or parts of it and substitutions of any components not original, makes the warranty to decay automatically. The manufacturer is considered responsible only if the instrument is used in its original configuration and setting. The flowmeter makes measures of liquids with conductivity greater than 5µS/cm; it consists of a sensor (described in this manual) and a converter, for it see the manual provided. If the sensor is supplied in compact version to the converter, consider the operating s more restrictive, otherwise refer to the respective manuals (page 7).). When transporting, unpacking and handling the flowmeter, be careful and care. In the case of prolonged storage and of transport, use and store in the original container in a dry place, do not place more than 3 packs one above the other. It is possible pallets storage and transport (in case of wooden crates do not place one above the other). For the cleaning of the device use only a damp cloth, and for the maintenance/repairs, contact the customer service. For the disposal of the device and of the packaging make strict reference to the regulations. It is forbidden the reproduction of the present manual and of possible software supplied with the instrument. START UP AND MAINTNANC OF TH INSTRUMNTS Before starting up the instrument, always make a sure connection to ground as suitable to page 8. Verify periodically: the cables integrity, the tightening of the sealing elements (cable glands, covers, etc.), the mechanical fixing of the instrument on the pipe or on the wall stand. 3

SAFTY Before using the instrument, always make a sure connection to the ground Avoid any attempt to repair the instrument. If the instrument is not functioning properly, please call the nearest assistance service Pay maximum attention during the operations ATTNTION!!! DANGR!!! GNRAL INFORMATION ON TH SNSORS INSTALLATION Flow direction Before install the sensor locate the direction of the liquid in the piping. The sign of the flow rate is positive, when the flow direction is from to + as printed on the tag plate. If after the installation, for plant request becomes necessary reverse the sign of the flow, it is enough reverse the sign of the coefficient KA Lifting sensor The sensors with eyebolts must be lifted by the method shown below. The eyebolt are measured to sustain exclusively the weight of the meter Centring cylinders 4

OVRALL DIMNSIONS mm DN (nominal diameter) 25 32 40 50 65 80 100 125 150 200 250 300 350 400 (inches) (1 ) (1¼ ) (1½ ) (2 ) (2½ ) (3 ) (4 ) (5 ) (6 ) (8 ) (10 ) (12 ) (14 ) (16 ) +0 +0 +0 +0 +0 +0 +0 +0 +0 +0 +0 +0 +0 +0 L 5 ( 0,20) 5 ( 0,20) 5 ( 0,20) 5 ( 0,20) 100 (3,94) 100 (3,94) 100 (3,94) 100 (3,94) 150 (5,90) 150 (5,90) 150 (5,90) 180 (7,09) 180 (7,09) 200 (7,87) 250 (9,84) 300 (11,81) 350 (13,78) 400 (15,75) H 147 153 161 177 199 209 235 263 291 362 417 467 527 579 (5,79) (6,02) (6,34) (6,97) (7,83) (8,23) (9,25) (10,35) (11,46) (14,25) (16,42) (18,39) (20,75) (22,80) D 62 67 78 92 108 118 144 172 200 271 326 376 436 488 (2,20) (2,44) (2,76) (3,39) (4,25) (4,65) (5,67) (6,77) (7,87) (10,67) (12,83) (14,80) (17,17) (19,21) G 144 194 244 294 344 (5,67) (7,64) (9,60) (11,57) (13,54) Weight kg (Ibs) 1,2 (2,64) 1,6 (3,52) 1,8 (3,96) 2 (4,4) 3,6 (7,92) 3,8 (8,36) 5 (11) 7,8 (17,16) 8,2 (18) 18,2 (40) 24 (53) 27 (59) 32 (70) 39 (86) Usable PTF-ebonite: PN10, PN16, PN25, PN40, ANSI150, ANSI300 flanges Polypropylene: PN10, PN16, ANSI150 PTF-ebonite: PN10, PN16, ANSI150 5

Shrewdness and precautions NO YS For vertical installations with descending flow direction contact the manufacturer For vertical installations is preferable an ascending flow Long pipe Avoid the installation of the sensor in a long pipe line, without any support of the same Anti vibration joints Long pipe For installation on long pipe line, please use the anti vibration joints Avoid the functioning with the pipe partially empty During the functioning the pipe must be completely full of liquid, or completely empty Avoid the installation near curves or hydraulic accessories Install the sensor away from curves and hydraulic accessories Avoid the approach of the flange and counter flange using the closing force of the nuts Before tightening the nuts approach as more possible the flange of the piping to the flange of the sensor Gasket thickness: +4 mm OPRATING TMPRATURS BONIT LINING POLYPROPYLN LINING (PP) PTF LINING Liquid Ambient Liquid Ambient Liquid Ambient Min. Maks. Min. Maks. Min. Maks. Min. Maks. Min. Maks. Min. Maks. C 0 80 5 60 0 60 0 60 20 130 10 60 F 30 176 23 140 32 140 32 140 4 266 14 140 6

LCTRICAL CONNCTIONS OF SNSOR TO CONVRTR Connections to converter: see proper manual VRSION SUITABL FOR SNSOR S CONNCTION COMPACT ALL SNSOR MODL NO CONNCTIONS SPARAT WITHOUT JUNCTION-BOX STAINLSS STL MODL NO CONNCTIONS RQUIRD (CABL ALRADY CONNCTD AND POTTD) SPARAT WITH JUNCTIONS-BOX (WITH OR WITHOUT PRAMPLIFIR) ALL CARBON STL MODLS NO CONNCTIONS RQUIRD (CABL ALRADY CONNCTD AND POTTD) SPARAT WITH PRAMPLIFIR ALL STAINLSS STL MODL NO CONNCTIONS RQUIRD (CABL ALRADY CONNCTD AND POTTD) 7

GROUNDING INSTRUCTIONS For correct operation of the meter is NCSSARY that the sensor and the liquid are equipotential, so ALWAYS connect the sensor and converter to ground: Grounding with metallic pipe Grounding with insulating pipe Insulating gasket If the sensor has to be mounted on a pipe made of an insulating materials necessary: Install two metallic ring between the sensor flanges and the counter flanges of the pipe line or Use a sensor with the additional grounding electrode Metallic ring Grounding when there is a cathodic protection over the pipe Metallic ring Insulating gasket If the sensor must be install in the piping with a cathodic protection, is necessary: Using insulating bushes to isolate the bolts Grounding metallic rings should be provided to ground the liquid using insulating gasket between the rings IMPORTANT: The ripple of DC power source used for cathodic protection shall be = 0 8

TORQUS [Nm] FOR WAFR SNSOR S BOLTS OPRATIV PRSSUR KPa 1600 4000 psi 260 600 DN bonite Polypropylene (PP) PTF 25 19 25 [32] 32 28 43 [40] 40 36 53 [63] 50 52 68 [35] 65 75 45 [53] 80 41 53 [68] 100 56 83 [94] 125 71 112 [130] 150 106 135 [113] 200 288 (433) 250 408 (455) 300 510 (683) 350 598 (946) 400 821 (911) Tighten uniformly in diagonally opposite sequence The torque listed in tab are applicable to flanges: N1092-1, DIN2501, BS4504, ANSI B16.5, JIS Is recommended the use of gaskets DIN 2690 (***)= FOR SNSORS ON ANSI 150 FLANGS [***]= FOR SNSORS ANSI 300 FLANGS 9

NOTS FOR PD DIRCTIV FOR SNSOR Here below the tables of products subject to Directive 97/23/C. The models are : FL1000/FL2410/FL2500. The tables show which category of PD is applicable according to the water operating (TAB A T <110 C TAB B T> = 110 C), sensor s DN and its nominal pressure. Table A PD DIRCTIV FOR WATR WITH TMPRATUR <110 C ALL LINING: PP, BONIT, PTF DN PN ( nominal pressure) 10 16 25 40 25 32 Use PN 40 40 50 65 80 Use Use 100 PN 16 PN 40 125 150 200 250 I I I I 300 I I I I 350 I I I I 400 I I I I 450 I I I I 500 I I I I 600 I I I I 700 I I I I 800 I I I I 900 I I I I 1000 I I I I 1200 I I I I 1300 I I I I 1400 I I I I 1500 I I I I 1600 I I I I 1700 I I I I 1800 I I I I 2000 I I I I 2400 I I I I DN 25 Table B PD DIRCTIV FOR WATR WITH TMPRATUR >=110 C ONLY PTF LINING PN (nominal pressure) 10 16 25 40 32 Use PN 40 40 II 50 80 Use I Use II 100 PN 16 I PN 40 II I 65 I II 125 I II 150 I II 200 I I II II 250 I II II II 300 I II III III 350 I III III III 400 II III III III 450 II III III III 500 II III III III I II III Legend OUT OF DIRCTIV PD CAT. I PD CAT. II PD CAT. III II 10