SystemStak Valves. ISO4401 Size 02

Similar documents
VICKERS. SystemStak Valves. ISO ; NFPA-D03; 315 bar (4500 psi); 60 L/min (15.7 USgpm) GB 2027B

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

Directional Controls

Flow Controls. DG**-06 Series Stacking Valves. Vickers. ISO (D06) Interface Flows to 340 l/min (90 USgpm) Pressure to 210 bar (3000 psi)

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm)

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

Directional Controls

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm)

Leak free Pipe Rupture Valve for Excavators

Cover headline. Cover subheadline. Check Valves

005 Series Modular Valves

PVQ 13 A2 R SE 1 S 20 C-11 D

Pressure control. Direct and pilot operated pressure control valves for applications up to 350 bar (5000 psi) and 300 L/min (80 USgpm)

Pressure reducing valve, direct operated

2-way flow control valve Model 2FRM 6

Leak-Free Load-Control Valve SAE ½ psi flange

Cooler-Bypass Thermostat Valve, Size 16

Pressure reducing valve, pilot operated, Model 3DR

Directional Valves. Hydraulic Operated Directional Valves

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

Lecture 19 PRESSURE-CONTROL VALVES [CONTINUED]

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

Electrically Operated Pressure-Relief Cartridge, Size 10

4/3 Directional valve elements L8_P5 with proportional (ED-IP) control and with or without LS connections L8_P5 (ED-IP)

180 Series Rotary Shear Directional Control Valve

3-Way Pressure-Reducing Cartridge, Size 2 4

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES

Double Pilot Operated Cartridge Check Valve, Size 8

Full Range Pressure Compensating Variable Flow Control

IFP C175-* REMOTE CONTROL RELIEF VALVE

Manapak Sandwich Valves Series CM, CPOM, FM, PRDM, PRM, RM

MODULES. Maximum Flow U.S.GPM. Max. Operating Pressure MPa (PSI) L/min. 005 Series 25 (3630) Modular Valves. 01 Series 31.

Pressure reducing valve, pilot operated

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Motion Controls Valve locator

Monoblock directional control valves ML - Directional control valve

DNS. Monoblock directional control valves DNS - Directional control valve

Flow Control Valves. 1 Description. 2 Symbols. Series MTKA, MTQA, MTCA 2.1 MTKA MTQA flow control valve. 1.1 MTKA flow control valve

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Function. Valve Size. Pilot Oil. p min. Bold: Designates Tier I products and options.

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

F05MSV-N* CONTINENTAL HYDRAULICS FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK F05MSV-N* - FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK

Directional Control Valves Technical Information Model 1500

Leak-Free Load-Control Valve, Size 20

Pressure reducing valve, direct operated

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

Introduction. Part one: Identify the Hydraulic Trainer Components

Pressure reducing valve, direct operated, type DR 5 DP Huade América 1

Pressure reducing/relief valve, pilot operated type UZCP10

Digital directional & flow control valves D-DF(R)G

Pressure-Relief Cartridge Valve, Size 4

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

Min. Metered Flow Capacity L/min. Max. Oper. Pressure Kgf/cm (0.04)* F- FC G N -11 H01. Max. Metered Flow Capacity L/min.

Proportional Throttle Cartridges, Size 16

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

PRESSURE REDUCING (AND CHECK) VALVES RT/RG RCT/RCG. -03/06/10 (3/8, 3/4, 1-1/4) Threaded Connections / Sub-plate Mounting

Sandwich Valves. 1 Change in flow, temperature or fluid (SSU) rating will affect valve

Electro-hydraulic Proportional Flow and Direction Control Valve

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

PRESSURE SEQUENCE VALVE TYPE UZK

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

Pressure reducing valve, direct operated, sandwich plate, type ZDR6D...40B/(New Series)

Size 10 (D05) p max 320 bar (4600 PSI) Technical Features. Technical Data. Port dimensions ZB10A(B) SMT_0019 ZB K -

ENGINEERING DATA. PVB Piston Pumps. w w w. F l u i D y n e F P. c o m Same Day Shipments of Units or Part Orders

Axial piston pumps type PVC

Axial piston pumps type PVC

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Pilot Operated Check Valves

BW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface

Inverse Proportional Pressure-Relief Cartridge, Size 10

shutoff valves 900 Series psig Manual Shutoff Valves

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

Lesson 6: Flow Control Valves

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

E Series Piston Pumps Variable Displacement Series for Mobile Applications Technical Catalog PVE012 PVE19 PVE21

Pilot Operated Check Valves Catalog Quick Reference

Cartridge Valves Technical Information. Pilot operated check valves. Quick reference

RE / Meter out pressure compensator Sandwich plate design Type SCA... /Series 2X. Description of function, Section 1/6. Replaces: 09.

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

Inverse Prop. Pressure-Relief Cart., Size 2 4

Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

PRESSURE COMPENSATORS TECNORD

Proportional Pressure-Relief Cartridge Valve, Size 2...4

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

Precision and Instrument Regulators 1/4" port size

Xpress L90LS Directional Control Valve. Catalog HY /UK December, 2001

Air preparation units

E SERIES. Specification. E Series. Relief and Flow Control Valves O M O M EIC-H Model No. Description

SINGLE VALVE WITH LOW-FLOW BYPASS

MECHANICALLY OPERATED DIRECTIONAL VALVES Rotary Type : DRT/DRG-02 Cam Operated : DCT/DCG-01, 03 Threaded Connection/Sub-plate Mounting

CV08-20 Check Valve DIRECTIONAL VALVES. DESCRIPTION A screw-in, cartridge-style, hydraulic check valve for use as a blocking or load-holding device.

Inverse Proportional Pressure-Relief Cart., Size 2 4

VACUUM REGULATORS CONTENTS

WK /2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32. Size 32 up to 42 MPa 700 dm 3 /min DESCRIPTION OF OPERATION

Float Operated Level Controllers

EXH. Specifications. Descriptions. Min. working pressure MPa

Pump safety block. Type DBA, DBAW, DBAE(E) Features. Contents. RE Edition: Replaces: 11.10

Double throttle/check valve, Type Z2FS Series 30 Huade América 1

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

Transcription:

SystemStak Valves ISO441 Size 2 Reduce System Space Requirements SystemStak valves make compact hydraulic systems in which specific function valves are sandwich mounted between a directional valve and a standard mounting surface. he design of this range of small stacking valves is based on the well proven Eaton DGM**-3, size 3 System Stak valves, and offers opportunities for achieving very small, compact control assemblies, especially when used with multi-point subplates. Reduce Cost SystemStak valves eliminate intervalve piping and leak-prone tube and pipe connections. Installed cost is less than when using conventional valves. Easy to Understand, Easy to Design SystemStak valves have all the internal passages necessary to serve the directional valve mounted on top of them. Mounting surfaces and port patterns are to the international standard: ISO/DIS 441-2-2. Rugged and Reliable Internal working parts are produced from hardened steel and mounted in free machining mild steel bodies. ll seals are Viton.Excellent reliability is ensured. Working parts on most models are accessible without removing valves from an assembled stak. Viton is a registered trademark of E.I. Duont Valve lacement SystemStak valves are divided into two groups: 1. Valves acting in the pressure and/or tank lines ( and/or ) DGMC Relief valve DGMDC Direct check DGMFD Flow divider DGMFN Flow control DGMFG ressure compensated flow control DGMR1 Sequence valve DGMX2 ressure reducing he general rule for this group is that the DGMC relief valve be placed nearest the subplate or manifold. he DGMDC direct check valve should be placed nearest the directional control valve. he DGMR1 sequence valve should be the farthest valve from the directional valve. he DGMR1 must be mounted directly to a subplate or manifold with a drain port, to externally drain the DGMR1 at the mounting face. 2. Valves acting in the service lines ( and/or ) DGMC Relief valve DGMC2 Dual relief valve DGMFD Flow divider DGMDC Direct check DGMC ilot operated check DGMFN Flow control DGMR Counterbalance he general rule for this group is that the DGMC system relief valve be the farthest valve from the directional valve. When using a DGMC with a DDMFN (meter-out), the DGMC should be nearest the directional valve. -2 EON DGM**-2 1 Design E-VVI-SS1-E1 October 215

Easy to Understand, Easy to Design SystemStak circuitry is best shown using slightly different symbols than those for traditional valve configurations. Each SystemStak symbol has the same basic form and size as shown in Figure 1. Figure 1. Figure 4. Figure 2. For ease of understanding, remember the directions of flow for each line, and that all four flow paths pass through each valve (see Figure 2). For clarity, directional valves are drawn vertically in SystemStak circuit diagrams (see Figure 3.) combination of directional valve, SystemStak valve(s) and subplate/manifold block (Figure 5 single station subplate and Figure 6 multi station manifold) completes the assembly. Figure 5. Figure 3. Each station (valve stack) is a combination of functions. When designing and assembling SystemStak valves, care must be taken to ensure that they interact as required by stacking the functions in the correct sequence (see Figure 4). Relief valves should normally be positioned next to the mounting surface (i.e. at the bottom of the stack). When both a flow control and a pilot operated check valve are required, it is recommended that the flow control valve be between the check valve and the actuator to prevent check valve chatter. Figure 6. Figure 7 represents a complete SystemStak system, showing typical use of functions available from this range. he circuit diagram also shows the use of a tapping plate for accessing line pressure readings, and a blanking plate to close off an unused station of a multi-station manifold. Figure 7. EON DGM**-2 1 Design E-VVI-SS1-E1 October 215-3

able of Contents Function asic symbol asic model Features age Relief DGMC Single, dual and crossport 3 models ilot relief DGMC ilot operated relief valve 9 Counterbalance DGMR Control in port 11 Sequence DGMR1 Single port sequence 11 Reducing DGMX iloted from (and reduced 11 pressure in) port, or Direct check DGMDC Single check in any port; dual 15 check in ports and only ilot operated check DGMC Single in port or ; dual 17 in ports and ressure compensated flow control DGMFG Single line, without check valve 2 Flow regulator valves DGMFN Flow restrictor 22 Flow divider valve DGMFD Divides flow equally 25-4 EON DGM**-2 1 Design E-VVI-SS1-E1 October 215

SystemStak Direct Relief Valves DGMC-2-1* series DGMC2-2-1* series General description hese adjustable direct-acting pressure relief valves limit the maximum pressure in the line(s) controlled by the integral relief valve elements. ressure adjustment options are screw/locknut, handknob and micrometer type with keylock. ypical Sectional View Model Code DGM C (2) 2 ** * * ( * * * ) 1* 1 2 3 4 5 6 7 8 9 1 Model Series Manifold or gasket mounted 2 Relief valve C ressure relief (single) C2 Dual relief 3 Interface 2 ISO441-2-2 4 First function Single relief, or first line of dual models ressure adjustment range 2 4 bar (29-58 psi) C 3 1 bar (435-145 psi) F 7 16 bar (1-23 psi) G 12 25 bar (174-36 psi) 1 5 8 ressure Discharge Usage Code limited in into Single Single or dual with Single Single or dual with Single 6 djustment type H Handknob K Micrometer withkeylock W Screw and locknut 7 Second function (Omit for single line models) ressure Discharge Usage Code limited in into Dual with Dual with ressure adjustment range 2 4 bar (29-58 psi) C 3 1 bar (435-145 psi) F 7 16 bar (1-23 psi) G 12 25 bar (174-36 psi) 9 djustment type H Handknob K Micrometer with keylock W Screw and locknut 1 Design Subject to change. Installation dimensions unchanged for design numbers 1 thru 19. EON DGM**-2 1 Design E-VVI-SS1-E1 October 215-5

Functional Symbols DGMC-2--** DGMC-2--** DGMC-2--**--** DGMC-2--**--** Operating Data Maximum flow rate Maximum operating pressure Hydraulic fluids Filtration requirements emperature limits Mass, approximate DGMC DGMC2 Mounting attitude 3 l/min (7.9 USgpm) 25 bar (36 psi) Refer to appendix,78 kg (1.7 lb.) 1,21 kg (2.7 lb.) No restrictions. erformance Data ressure Override ypical performance for models at maximum pressure settings with mineral oil at 21 cst (12 SUS) and at 5ºC (122ºF). psi 3 bar 25 2 DGMC2-- G *-1* ressure 2 15 DGMC2-- F *-1* 1 1 5 DGMC2-- C *-1* DGMC2-- *-1* 5 1 15 2 25 3 l/min For other viscosities refer to appendix. 1 2 3 4 5 6 7 7.9 Flow rate USgpm -6 EON DGM**-2 1 Design E-VVI-SS1-E1 October 215

Installation Dimensions Dimensions shown in mm (inches) DGMC-2--*W-1* DGMC-2--*W-1* DGMC-2--*W-1* 3rd angle projection 4 holes thru 5,5 (.21 dia.) djuster screw 4, (5/32 ) across flats hex. socket 36,8 (1.45) 35, (1.38) 17,5 (.69) 12,7 (.5) 34, (1.34) 25, (.99) 5, (1.97) 132,5 (5.22) max. 58,5 (2.3) Hex locknut 12,7 (1/2 ) 3, (1.18) 15, (.59) 29, (1.14) 3, (.12) 3, (.12 dia.) 15,5 (.61) DGMC-2--*W-1* DGMC-2--*W-1* djuster screw 4, (5/32 ) across flats hex. socket 4 holes thru 5,5 (.21 dia.) 34, (1.34) 12,7 (.5) 17,5 (.69) 35, (1.38) 36,8 (1.45) Hex locknut 12,7 (1/2 ) 58,5 (2.3) 132,5 (5.22) max. 25, (.99) 5, (1.97) 29, (1.14) 15, (.59) 3, (1.18) 15,5 (.61) 3, (.12 dia.) 3, (.12) EON DGM**-2 1 Design E-VVI-SS1-E1 October 215-7

Installation Dimensions Dimensions shown in mm (inches) DGMC2-2--*W--*W-1* DGMC2-2--*W--*W-1* W adjuster (Shown) o adjust valve setting. oosen locknut and turn adjuster screw clockwise to increase pressure, counterclockwise to decrease pressure. Re-tighten locknut after completing adjustment. 4 holes thru 5,5 (.21 dia.) Hex locknut 12,7 (1/2 ) across flats 36,8 (1.45) 17,5 (.69) 35, (1.38) 12,7 (.5) 34, (1.34) 58,5 (2.3) 25, (.99) 5, (1.97) 265, (1.43) max. 58,5 (2.3) djuster screw 4, (5/32 ) across flats hex. socket 3, (1.18) 15, (.59) 29, (1.14) 3, (.12) 3, (.12 dia.) H adjuster o adjust valve setting. oosen locknut and turn knob clockwise to increase pressure, counterclockwise to decrease pressure. Re-tighten locknut after completing adjustment. K adjuster Key must be inserted and turned to allow valve setting to be adjusted. urn knob clockwise to increase pressure, counterclockwise to decrease pressure. When key is removed, adjustment mechanism can be freely turned without changing valve setting. 94,5 (3.72 max.) 25, (.99) square 119, (4.68) 26, (1.2) 2, (.78) -8 EON DGM**-2 1 Design E-VVI-SS1-E1 October 215

SystemStak ilot Operated Relief Valve DGMC-2--CH-1 EN81 General description his adjustable direct-acting pressure relief valve limits the maximum pressure in the line controlled by the integral relief valve element. ressure adjustment is by handknob or by remote pilot pressure. ypical Sectional View Model Code DGM C 2 C H 1 EN81 1 2 3 4 5 6 7 8 1 Model Series Manifold or gasket mounted 2 Relief valve C ressure relief (single) 3 Interface 2 ISO441-2-2 4 Function Single relief ressure Discharge Code limited in into Usage Single 5 ressure adjustment range C 3 1 bar (435-145 psi) 6 djustment type H Handknob 7 Design Subject to change. Installation dimensions unchanged for design numbers 1 thru 19. 8 Special feature EN81 Remote pilot option Functional Symbol EON DGM**-2 1 Design E-VVI-SS1-E1 October 215-9

Operating Data Maximum flow rate Maximum operating pressure Hydraulic fluids Filtration requirements emperature limits Mass, approximate Mounting attitude 3 l/min (7.9 USgpm) 25 bar (36 psi) Refer to appendix,78 kg (1.7 lb.) No restrictions. erformance Data ypical performance with mineral oil at 21 cst (12 SUS) and at 5 C (122 F). For other viscosities refer to appendix. psi bar 25 DGMC2--G *-1* 3 2 ressure 2 1 15 1 5 DGMC2--F *-1* DGMC2--C *-1* DGMC2--*-1* 5 1 15 2 25 3 l/min erformance Characteristic Flow rate versus pressure for number of turns of adjuster from fully closed position. ressure Override Free flow through check valve with throttle closed and open. 1 2 3 4 5 6 7 7.9 USgpm Flow rate Installation Dimensions Single Function DGMC-2--CH-1 EN81 Dimensions shown in mm (inches) 3, (1.18) 81,5 (3.2) 121,8 (4.79) max. H adjuster o adjust valve setting. loosen locknut and turn knob clockwise to decrease flow (increase restriction), counterclockwise to increase flow (reduce restriction). Re-tighten locknut after completing adjustment. -1 EON DGM**-2 1 Design E-VVI-SS1-E1 October 215

SystemStak ressure Control Valves Counterbalance, Sequence and ressure Reducing DGMR(1)-2-1* series DGMX2-2-1* series General description hese single stage valves operate by the application of pressure on the end of the valve spool, acting against a spring which is loaded by means of the manual adjustment mechanism. In the counterbalance and sequence valves, the spool is offset by the spring such that flow cannot pass through the valve. When the force exerted by the pilot pressure on the spool end exceeds the force of the main spring, the spool is moved to allow flow through the valve. In the pressure reducing valve, the flow path is normally open and is closed as the pilot pressure exceeds the manual setting of the valve. Excessive pressure in the reduced pressure line is prevented by a pressure relieving function. ressure adjustment options are screw/locknut, handknob and micrometer type with keylock. ypical Sectional Views DGMX2-2-*-*W-1 DGMR1-2--*W-1 Model Code DGM ** 2 ** * * 1* 1 2 3 4 5 6 7 Model Series Manifold or gasket mounted 2 ype R Counterbalance R1 Sequence X2 ressure reducing 3 Interface 2 ISO441-2-2 Function ports DGMR models only: Counterbalance control function in port, controlled by pressure in port. DGMR1 models only: Sequence control in port, controlled by pressure in port DGMX2 models only: ressure reducing function in line, piloted from ressure reducing function in line, piloted from ressure reducing function in line, piloted from ressure adjustment range 2 16 bar (29-232 psi) 2 4 bar (29-58 psi) C 3 1 bar (435-145 psi) F 7 16 bar (1-23 psi) G 12 25 bar (174-36 psi) 1 4 5 6 djustment type H Handknob K Micrometer with keylock W Screw and locknut 7 Design Subject to change. Installation dimensions unchanged for design numbers 1 thru 19. EON DGM**-2 1 Design E-VVI-SS1-E1 October 215-11

Functional Symbol DGMR-2- DGMR1-2- DGMX2-2- DGMX2-2- DGMX2-2- Operating Data Maximum flow rate Maximum operating pressure Hydraulic fluids Filtration requirements emperature limits Mass, approximate (all models) Mounting attitude 3 l/min (7.9 USgpm) 25 bar (36 psi) Refer to appendix,87 kg (1.9 lb.) No restrictions. -12 EON DGM**-2 1 Design E-VVI-SS1-E1 October 215

erformance Data ypical performance with mineral oil at 21 cst (12 SUS) and at 5 C (122 F). DGMX2-2-* DGMR1-2- ressure psi bar 3 4 25 DGMX2-2-*-G*-1* 3 2 DGMX2-2-*-F*-1* 15 2 1 DGMX2-2-*-C*-1* 1 DGMX2-2-*-*-1* 5 DGMX2-2-*-*-1* 1 5 5 1 15 2 25 3 l/min 3 2 1 1 2 3 4 5 6 7 7.9 USgpm Reverse flow to line Reduced pressure line Flow rate ressure psi 3 2 1 bar DGMR1-2--G*-1* 25 2 DGMR1-2--F*-1* 15 DGMR1-2--C*-1* 1 5 DGMR1-2--*-1* 5 1 15 2 25 3 l/min 1 2 3 4 5 6 7 7.9 USgpm Flow rate Note: Valves will not function at pressure/flow values in shaded area. ypical leakage flow from reduced pressure line into at dead-head condition (i.e. no flow required at reduced pressure outlet). his leakage flow must be provided at the inlet line in order to maintain the reduced outlet pressure. Note that the effective reduced pressure is the sum of the valve adjustment and any back pressure in line. he effect is illustrated below. in 3 /min cm 3 /min 3 15 25 2 1 15 1 5 5 eakage flow rate Inlet pressure 25 bar (36 psi) 5 1 15 2 25 bar ypical installation Crossover plate DGMX2-2- Subplate 1 2 3 36 psi Reduced outlet pressure For other viscosities refer to appendix EON DGM**-2 1 Design E-VVI-SS1-E1 October 215-13

Installation Dimensions Dimensions shown in mm (inches) DGMR--*W-1* DGMR1--*W-1* DGMX2-*-*W-1* W adjuster (Shown) o adjust valve setting. loosen locknut and turn adjuster screw clockwise to increase pressure, counterclockwise to decrease pressure. Re-tighten locknut after completing adjustment. 4 holes thru 5,5 (.21 dia.) djuster screw 4, (5/32 ) across flats hex. socket) 36,8 (1.45) 35, (1.38) 17,5 (.69) 12,7 (.5) 34, (1.34) 25, (.99) 5, (1.97) 74, (2.91) 148, (5.83) max. Hex locknut 12,7 (1/2 ) 3, (1.18) 15, (.59) 29, (1.14) 3, (.12) 3, (.12 dia.) 19,5 (.77) H adjuster o adjust valve setting. loosen locknut and turn knob clockwise to increase pressure setting, counterclockwise to decrease pressure setting. Re-tighten locknut after completing adjustment. K adjuster 11, (4.33 max.) 25, (.99) square Key must be inserted and turned to allow valve setting to be adjusted. urn knob clockwise to increase pressure setting, counterclockwise to decrease pressure setting. When key is removed, adjustment mechanism can be freely turned without changing valve setting. 134,5 (5.29) 26, (1.2) 2, (.78) -14 EON DGM**-2 1 Design E-VVI-SS1-E1 October 215

SystemStak Direct Check Valves DGMDC-2, 1* series General description hese valves allow free flow in one direction in the line in which the check valve element is located, i.e. either line or line. Flow in the opposite direction is not possible. ypical Sectional Views Model Code D GMDC-2-Y-*-1* DGMDC-2- X-*-1* DGM DC 2 * * * 1* 1 2 3 4 5 6 1 Model Series Manifold or gasket mounted 2 ype DC Direct check Functional Symbol 3 Interface 2 ISO441-2-2 4 Direction of flow and check location X- Free flow away from actuator, in line Y- Free flow towards actuator, in line Check valve cracking pressure K 1 bar (14.5 psi) M 2,5 bar (36 psi) 5 6 Design Subject to change. Installation dimensions unchanged for design numbers 1 thru 19. DGMDC-2-Y-* DGMDC-2-X-* EON DGM**-2 1 Design E-VVI-SS1-E1 October 215-15

Operating Data Maximum flow rate Maximum operating pressure Hydraulic fluids Filtration requirements emperature limits Mass, approximate Mounting attitude 3 l/min (7.9 USgpm) 25 bar (36 psi) Refer to appendix,35 kg (.77 lb.) No restrictions erformance Data ypical performance with mineral oil at 21 cst (12 SUS) and at 5 C (122 F). ressure Drop Free flow through check valve psi bar 15 1 ressure drop 8 1 DGMDC-2*-*-*K-1* 6 5 4 DGMDC-2*-*-*M-1* 2 5 1 15 2 25 3 l/min 1 2 3 4 5 6 7 7.9 USgpm Flow rate Internal eakage cross Closed Check Valve ess than,25 cm 3 /min (.15 in 3 /min) at 25 bar (36 psi). For other viscosities refer to appendix Installation Dimensions Dimensions shown in mm (inches) DGMDC-2-Y-*-1* DGMDC-2-X-*-1* 36,8 (1.45) 35, (1.38) 17,5 (.69) 4 holes thru 5,5 (.21 dia.) 25, (.99) 5, (1.97) 3, (1.18) 3, (.12) 3, (.12 dia.) -16 EON DGM**-2 1 Design E-VVI-SS1-E1 October 215

SystemStak ilot Operated Check Valves DGMC-2-1* series General description hese valves provide pilot operated check functions in one or both service lines ( or ), the operating pilot supply coming from the opposite service line. hus with pressure in one service line the check valve in the other service line will be open (subject to system/actuator pressures being correct for the valve area ratios). he area ratio of pilot piston to check valve seat is 3,3:1. ypical Sectional Views DGMC-2 Dual Function DGMC-2 Single Function Model Code DGM C 2 ** * ( ** *) 1* 1 2 3 4 5 6 7 8 1 Model Series Manifold or gasket mounted 2 ype C ilot operated check 3 Interface 2 ISO441-2-2 4 Function Check in line, pilot operated from line Check in line, pilot operated from line (single function model only) 5 Check valve cracking pressure K 1 bar (14.5 psi) M 2,5 bar (36 psi) 6 Second function of dual models Check in line, pilot operated from line Omit for single function models 7 Check valve cracking pressure (Second function of dual models) K 1 bar (14.5 psi) M 2,5 bar (36 psi) 8 Design Subject to change. Installation dimensions unchanged for design numbers 1 thru 19. Functional Symbols DGMC-2-*-*-1* DGMC-2-*-1* DGMC-2-*-1* 1 1 1 1 1 1 EON DGM**-2 1 Design E-VVI-SS1-E1 October 215-17

Operating Data Maximum flow rate Maximum operating pressure Hydraulic fluids Filtration requirements emperature limits Mass, approximate Mounting attitude 3 l/min (7.9 USgpm) 25 bar (36 psi) Refer to appendix,39 kg (.86 lb.) No restrictions. erformance Data ypical performance with mineral oil at 21 cst (12 SUS) and at 5 C (122 F). ressure Drop psi bar 3 16 25 14 DGMC-2-**K (-**K )-1* ressure drop 2 15 1 12 8 DGMC-2-**M(-**M)-1* 5 4 Reverse flow: check valve piloted open 5 1 15 2 25 3 l/min 1 2 3 4 5 6 7 Flow rate For other viscosities refer to appendix 7.9 USgpm ilot ressures rea ratio, pilot piston to check valve = 3,3:1 Formula for calculating pilot pressure required to open valve: p o open valve in line : ressure at 1 = + p C p 1 rea ratio factor p o open valve in line : ressure at 1 = + p C p 1 rea ratio factor +p 1 +p 1 Where p = ressure at p C = Cracking pressure p 1 = ressure at 1 p = ressure at p 1 = ressure at 1 = Service line location; = Refer to functional 1 = symbols. 1 = -18 EON DGM**-2 1 Design E-VVI-SS1-E1 October 215

Installation Dimensions Dual Function Models DGMC-2-*-*-1* Dimensions shown in mm (inches) 4 holes thru 5,5 (.21 dia.) 36,8 (1.45) 35, (1.38) 17,5 (.69) 18,3 (.72 dia.) 6, (.23) 5, (1.97) 6, (.23) 62, (2.44) 3, (1.18) 18, (.71) 3, (.12) 3, (.12 dia.) Single Function Models DGMC-2-*-1* 18,3 (.72 dia.) 6, (.23) 5, (1.97) 62,2 (2.45) 6,2 (.24) Single Function Models DGMC-2-*-1* 6,2 (.24) 5, (1.97) 6, (.23) 62,2 (2.45) EON DGM**-2 1 Design E-VVI-SS1-E1 October 215-19

SystemStak ressure Compensated Flow Control Valve DGMFG-2-Y-H-1 series General description hese valves regulate flow by means of an adjustable orifice. Flow through the valve is pressure compensated. Currently this function is available in a single line version, without check valve. djustment option is only available with handknob. lease contact your Eaton representative for availability of other options. ypical Sectional Views Model Code DGMFG 2 Y H 1 1 2 3 4 5 6 Model Series Directional valve, gasket mounted, pressure compensated flow control 3 Direction of flow control (with respect to machine actuator) Y Meter-out control ocation of control function (single model) ine (single model) 1 4 5 djustment type H Handknob 6 Design number 2 Interface 2 ISO441-2-2 Functional Symbol DGMFG-2-Y-H-1 Operating Data Maximum flow rate Maximum operating pressure Hydraulic fluids Filtration requirements emperature limits Mass, approximate Mounting attitude 3 l/min (7.9 USgpm) 25 bar (36 psi) Refer to appendix,42 kg (.93 lb.) No restrictions -2 EON DGM**-2 1 Design E-VVI-SS1-E1 October 215

erformance Data ypical performance with mineral oil at 21 cst (12 SUS) and at 5 C (122 F). Control characteristics For other viscosities refer to appendix. Flow rate versus pressure Drop ressure drop psi 9 8 7 6 5 4 3 bar 6 5 4 3 2 2 1 1 1 2 3 l/min 2 4 6 8 Flow Rate USgpm Installation Dimensions Dimensions shown in mm (inches) H adjuster (shown) o adjust valve setting. loosen locknut and turn knob clockwise to decrease flow (increase restriction), counterclockwise to increase flow (reduce restriction). Re-tighten locknut after completing adjustment. Single Function DGMG-2-Y-H-1 25, (.99) square 28, (1.9 dia.) 15, (1.9) 3, (1.18) 1,5 (.41) 41, 5, (1.96) (1.61 max.) 11,5 (3.98 max.) 3, (.12) 3, (.12 dia.) EON DGM**-2 1 Design E-VVI-SS1-E1 October 215-21

SystemStak Flow Regulator Valves DGMFN-2-1* series General description hese valves regulate flow by means of an adjustable orifice. Flow through the valve at any setting of the orifice is dependent upon pressure drop. Dual service-line models with integral non-return valves provide for meter-in or meter-out control; single line versions of these are available. dditionally there is a single line model, without check valve, for controlling flow in line. djustment options are screw/locknut, handknob or micrometer with keylock. ypical Sectional Views Model Code DGM FN 2 * * * ( * *) 1* 1 2 3 4 5 6 7 8 9 1 Model Series Manifold or gasket mounted 2 ype FN Flow restrictor Y Meter-out control, applicable to lines and. Z Meter-in control, line only. 6 djustment type H Handknob K Micrometer with keylock W Screw and locknut 8 djustment type (Omit for single models) H Handknob K Micrometer with keylock W Screw and locknut 3 Interface 2 ISO441-2-2 4 Direction of flow control (with respect to machine actuator) X Meter-in control, applicable to lines and. 5 ocation of control function (single model or first line of dual model) ine (single model or first line of dual model) ine (single model only) ine (single model only) 7 Control in second line ine (use for dual models with specified at 5 ) Omit for single function models 9 Design Subject to change. Installation dimensions unchanged for design numbers 1 thru 19. Functional Symbols DGMFN-2-X-*-* DGMFN-2-Y-*-* DGMFN-2-Z-* -22 EON DGM**-2 1 Design E-VVI-SS1-E1 October 215

Operating Data Maximum flow rate Maximum operating pressure Hydraulic fluids Filtration requirements emperature limits Mass, approximate Mounting attitude 3 l/min (7.9 USgpm) 25 bar (36 psi) Refer to appendix,42 kg (.92 lb.) No restrictions erformance Data ypical performance with mineral oil at 21 cst (12 SUS) and at 5 C (122 F). Control characteristics Flow rate versus pressure drop for number of turns of adjuster from fully closed position. ressure Drop Free flow through check valve with throttle closed and open. psi 36 bar 25 1 1 1 / 4 1 1 / 2 1 3 / 4 2 2 1 / 4 2 1 / 2 ressure drop 3 2 1 2 15 1 5 2 3 / 4 3 3 1 / 4 3 1 / 2 3 3 / 4 4 ressure drop psi bar 25 3 2 2 15 1 1 5 l/min With throttle fully closed With throttle fully open 5 1 15 2 25 3 l/min 5 1 15 2 25 3 USgpm 1 2 3 4 5 6 7 7.9 Flow rate USgpm 1 2 3 4 5 6 7 7.9 Flow rate For other viscosities refer to appendix. EON DGM**-2 1 Design E-VVI-SS1-E1 October 215-23

Installation Dimensions Dual Function DGMFN-2-X-*-*-1* DGMFN-2-Y-*-*-1* 36,8 (1.45) Dimensions shown in mm (inches) 17,5 (.69) 35, (1.38) ine adjustment 4 holes thru 5,5 (.21 dia.) Hex locknut 12,7 (1/2 ) across flats djuster screw 4, (5/32 ) across flats hex. socket W adjuster (Shown) o adjust valve setting. loosen locknut and turn adjuster screw clockwise to decrease flow (increase restriction), counterclockwise to increase flow (reduce restriction). Re-tighten locknut after completing adjustment. 3, (1.18) 3, (.12) 25, (.99) 5, (1.97) 18,4 (4.27) max. ine adjustment 3, (.12 dia.) 15, (.59) 12,7 (.5) Single Function Single Function DGMFN-2-X-*-1* DGMFN-2-Y-*-1* DGMFN-2-X-*-1* DGMFN-2-Y-*-1* DGMFN-2-Z-*-1* H adjuster o adjust valve setting. loosen locknut and turn knob clockwise to decrease flow (increase restriction), counterclockwise to increase flow (reduce restriction). Re-tighten locknut after completing adjustment. K adjuster 29,2 (1.15) 79,2 (3.12) 5, (1.97) 41,5 (1.63 max.) 25, (.99) square 5, (1.97) 79,2 (3.12) 29,2 (1.15) Key must be inserted and turned to allow valve setting to be adjusted. urn knob clockwise to decrease flow (increase restriction), counterclockwise to increase flow (reduce restriction). When key is removed, adjustment mechanism can be freely turned without changing valve setting. 69, (2.72) 26, (1.2) 2, (.78) 25, (1. dia.) -24 EON DGM**-2 1 Design E-VVI-SS1-E1 October 215

SystemStak Flow Divider Valve DGMFD-2-1 series General description ypical Sectional View his flow dividing valve divides flow equally between the port and the port with flow generated in port. Note - he flow divider valve should not be applied where cylinder synchronization is important. Model Code DGM FD 2 1 1 2 3 4 5 6 1 Model Series Manifold or gasket mounted 2 ype FD Flow divider Interface 2 ISO441-2-2 4 First function Flow from port Flow division Flow split between ports and 3 5 6 Design Subject to change. Installation dimensions unchanged for design numbers 1 thru 19. Functional Symbols DGMFD-2---1 EON DGM**-2 1 Design E-VVI-SS1-E1 October 215-25

Operating Data Maximum flow rate 3 l/min (7.9 USgpm) Flow variation (between & ports) ± 1% Maximum operating pressure 25 bar (36 psi) Hydraulic fluids Filtration requirements Refer to appendix emperature limits Mass, approximate,58 kg (1.3 lb.) Mounting attitude No restrictions erformance Data ypical performance with mineral oil at 3 cst (14 SUS) and at 5 C (122 F). For other viscosities refer to appendix ressure Drop ressure drop psi 7 6 5 4 3 2 1 bar 5 4 3 2 1 5 1 15 2 25 3 l/min 1 2 3 4 5 6 7 Flow rate 7.9 USgpm Installation Dimensions DGMFD-2-1 series Flow Divider Dimensions shown in mm (inches) DGMFD 35, (1.37) 11, (.43) 5, (1.96) 11, (.43) 72, (2.83) -26 EON DGM**-2 1 Design E-VVI-SS1-E1 October 215

EON DGM**-2 1 Design E-VVI-SS1-E1 October 215-27

Eaton Hydraulics usiness US 14615 one Oak Road Eden rairie, MN 55344 US el: 952-937-98 Fax: 952-294-7722 www.eaton.com/hydraulics Eaton Hydraulics usiness Europe Route de la ongeraie 7 111 Morges Switzerland el: +41 () 21 811 46 Fax: +41 () 21 811 461 Eaton Hydraulics Group sia acific Eaton uilding 4 th Floor, No. 3 ane 28 inhong Rd. Changning District Shanghai 2335 China el: (+86 21) 52 99 Fax: (+86 21) 52 4 215 Eaton ll Rights Reserved rinted in US Document No.: E-VVI-SS1-E1 October 215