Nugget 0 V Series /2 & /3 Valves Solenoid and Pilot Operated G 1 4 High flow compact valves Sub-base and low profile manifolds Light weight, long life corrosion resistant materials Multipole and Fieldbus compatible Flexible single step expansion Technical Data Medium: Compressed air, filtered to 40µm, lubricated or non-lubricated Operation: Spool valve, indirectly actuated. Cylinder ports in valve or base Mounting: On sub-base or manifold Port Size: Operating Pressure: Maximum bar. For details see overleaf Flow Characteristics: Size Function C b A l/min Cv Kv /2 4,92 0,23 17,31 112 1,17 1,02 /3 3,22 0,44,7 77 0,79 0,6 Ambient Temperature: -20 C to +0 C Pilot models -20 C to +0 C Solenoid models *Consult our Technical Service for use below +2 C Materials Aluminium alloy body. Glass filled PA (nylon) or glass filled PPS (polyphenylene sulphide) end caps. Glass filled PBT (polybutylene terephthalate) solenoid adapters Aluminium alloy pistons and spool with HNBR (hydrogenated nitrile) seals. Aluminium alloy Sub-bases and Manifolds with NBR (nitrile butadiene) gaskets. Ordering Information To order, quote model number and voltage code from tables overleaf, e.g. VB17A-B3A for a Solenoid Pilot Actuated, Spring Return model fitted with a 24 V d.c. coil and screwdriver operated manual override. /2 /2 Twin Supply /3 All ports blocked mid position /3 Centre open exhaust mid position /3 Centre open pressure mid position For further technical data on Multipole Systems and complete Valve Islands see Section.4.16 4 1 2 3 7/9 N /UK.4.1.01
Nugget 0, V Series General Information /2 Solenoid Actuated Valves, supplied with gaskets as indicated Symbol Model Manual Pilot Supply Operator Return Operating Pilot Weight Spares kit Mounting Override (Gasket Type) Pressure (bar) Pressure (bar) (kg) Option VB17A-B*A VB17A-B31*A Internal (W) Solenoid Spring 1,2 - - 0,1 V316-K30 All Bases VBA-B*A VBA-B31*A External (X) Solenoid Spring -0,9-1,2-0,1 V316-K30 Sub-bases 1 3 VBF7A-B*A VBF7A-B31*A Internal Twin Supply (Z) Solenoid Spring -0,9-1,2-0,1 V316-K30 Single Sub-base and Manifold VBE7A-B*A VBE7A-B31*A Independent External (Y) Solenoid Spring -0,9-1,2-0,16 V316-K30 Single Sub-base and Manifold VB11A-B*A VB11A-B31*A Internal (W) Solenoid Solenoid 1,2 - - 0, V316-K30 All Bases / VB22A-B*A VB22A-B31*A External (X) Solenoid Solenoid -0,9-1,2-0, V316-K30 Sub-bases 1 3 VBFFA-B*A VBFFA-B31*A Internal Twin Supply (Z) Solenoid Solenoid -0,9-1,2-0, V316-K30 Single Sub-base and Manifold VBEEA-B*A VBEEA-B31*A Independent External (Y) Solenoid Solenoid -0,9-1,2-0,23 V316-K30 Single Sub-base and Manifold /3 Solenoid Actuated Valves, supplied with gaskets as indicated Symbol Model Manual Pilot Supply Operator Mid- Return Operating Pilot Weight Spares kit Mounting Override (Gasket Type) Position Pressure (bar) Pressure (bar) (kg) Option VB611A-B*A VB611A-B31*A Internal (W) Solenoid APB Solenoid 1,2 - - 0,22 V317-K30 All Bases / VB622A-B*A VB622A-B31*A External (X) Solenoid APB Solenoid -0,9-1,2-0,22 V317-K30 Sub-base 4 2 VB6FFA-B*A VB6FFA-B31*A Internal Twin Supply (Z) Solenoid APB Solenoid -0,9-1,2-0,22 V317-K30 Single Sub-base and Manifold 4 2 VB711A-B*A VB711A-B31*A Internal (W) Solenoid COE Solenoid 1,2 - - 0,22 V31-K30 All Bases / VB722A-B*A VB722A-B31*A External (X) Solenoid COE Solenoid -0,9-1,2-0,22 V31-K30 Sub-bases VB11A-B*A VB11A-B31*A Internal (W) Solenoid COP Solenoid 1,2 - - 0,22 V3-K30 All Bases / VB2A-B*A VB2A-B31*A External (X) Solenoid COP Solenoid -0,9-1,2-0,22 V3-K30 Sub-base * Insert Voltage Code from table opposite. Pressure to port must not be less than 1,2 bar. Gasket type supplied with the valve, for details see page.4.1.0. Type Y gaskets are supplied with the Fixed Length Manifold and the Single Station Sub-base. APB = All Ports Blocked, COE = Centre Open Exhaust, COP = Centre Open Pressure. N /UK.4.1.02
Nugget 0, V Series Pilot Actuated Valves, supplied with Sub-base gaskets Symbol Model Gasket Operator Mid- Return Operating Pilot Weight Spares kit Mounting Type Position Pressure (bar) Pressure (bar) (kg) Option VBD7A-X0090 X Pilot - Spring -0,9-1,2-0,0 V316-K30 All Bases VBDDA-X0020 X Pilot - Pilot -0,9-1,2-0,0 V316-K30 All Bases VB9DA-X0060 X Pilot Priority - Pilot -0,9-1,2-0,0 V316-K30 All Bases VB6DDA-X0020 X Pilot APB Pilot -0,9-1,2-0,0 V317-K30 All Bases VB7DDA-X0020 X Pilot COE Pilot -0,9-1,2-0,0 V31-K30 All Bases VBDDA-X0020 X Pilot COP Pilot -0,9-1,2-0,0 V3-K30 All Bases Gasket type supplied with the valve, for details see page.4.1.0. APB = All Ports Blocked, COE = Centre Open Exhaust, COP = Centre Open Pressure *Voltage Codes Voltage Codes Power Inrush/Hold 6V d.c. 1 1, W V d.c. 2 1,7 W 24V d.c. 3 1,7 W V 0/60Hz 1 4,1/2,9 VA 24V 0/60Hz 4 4,1/2,9 VA 4V 0/60Hz 6 4,1/2,9 VA 1V 0/60Hz 3,/2, VA 240V 0/60Hz 9 3,/2, VA Electrical Details for Solenoid Operators Voltage Tolerances: ±% Rating: 0% E.D. Inlet Orifice: 0, mm Electrical Connection: DIN 43 60 table C Manual Override: VB--A B*A Push button, spring return with locking facility VB--A B31*A Push button, spring return Protection Class: IP 6 (DIN 40 00) For details of connector plugs and light emitting seals see page 7.7.001. Bases and Accessories Single Station Sub-base Single Station Sub-base Sub-base Assemblies - Side Ported Sub-base Assemblies - Bottom Ported Fixed Length Manifold Side Ported Bottom Ported VCAX**-XXXXX Single Pressure VCCX**-XXXXX Single Pressure V02-G** V1-G01 G 1 4 V2-G01 G 1 4 VCAX**-**XXX Dual Pressure VCCX**-**XXX Dual Pressure 01, 02, 04, 06, 0,, Stations Intermediate Supply/ Exhaust Plate Blanking Plate for unused station Pressure Indicator DIN-rail Mounting Kit DIN-rail VB17A-Q240G VB17A-Q00 VB17A-Q200 V3-K30 V009-C00 1 Metre Modular Sub-base End Plate Kit Tie Rod Kit Blanking Gasket Set Blanking Plug VB17R-Q0G Side Ported VB17R-Q00G Side Ported VB17A-Q04** Modular Sub-base V040-K96 Modular Sub-base V320-K01 Manifold G 3 VB17R-Q020G Bottom Ported VB17R-Q01G Bottom Ported V320-K02 Manifold G 1 4 ** = 02 to 16 stations.(01, 02, 04, 06, 0,, stations for Fixed Length Manifold) **-** = 01 to 1 to indicate position of Dual Pressure Blanking Plate. See page 6 7/9 N /UK.4.1.03
Nugget 0, V Series VB*7A Models /2 Single Solenoid Valves VB**A Models /2 Double Solenoid Valves 0 17 Manual Override A/F Manual Override 1, 1, 1 9 VBE7A Models /2 Single Solenoid Valves With Independent External Pilot Supply VBEEA Models /2 Double Solenoid Valves With Independent External Pilot Supply Independant External Pilot Supply Independant External Pilot Supply '' '' '' 1 20 Manual Override A/F Manual Override 3, M 39,2 1 1, 7,7 M 41,2 4 63,7 1, VB***A Models /3 Double Solenoid Valves 3 Manual Override 1, 4.4.1.04 N /UK.4.1.04
Nugget 0, V Series VBD7A-X0090 /2 Single Pilot Valve VB**A Models /2 Double Pilot Valves '' '' '' 2 2 1, M Pilot 4,2 2 A/F 1, 3 M 4,2 Pilots 2 4, 1, VB*DDA Models /3 Double Pilot Valves Surface Mounting Details 32 '' 117 '' M3 1,2 M Pilots 3 4, 1, 4,2 67 Functional Valve Gaskets For Modular Sub-base mounting, gaskets supplied with the valve must be used. For Single Station Sub-base and Fixed Length Manifold mounting, gaskets supplied with the base must be used except for Twin Supply Valves where gaskets supplied with the valve must be used. For Modular Sub-base V041-C9 - Internal Pilot Supply Gasket Gasket Type: W supplied with all internal pilot supply valves '' '' '' Black For Fixed Length Manifold and Single Station Sub-bases '' '' V23-C01 - Internal Pilot Supply Gasket Gasket Type: Y Supplied with Fixed Length Manifolds and Single Station Sub-bases V041-C96 - External Pilot Supply Gasket Gasket Type: X supplied with all external pilot supply valves and pilot operated valves '' '' '' '' Red '' V239-C01 - Twin Supply Gasket Gasket Type: Z Supplied with Twin Supply Valves '' '' '' '' '' '' '' '' '' '' Grey Yellow 7/9 N /UK.4.1.0
Nugget 0, V Series Pressure Options - Fixed Length Manifold Systems Single Pressure Dual Pressure Three Pressure Blanking Plug Blanking Plugs '' '' '' P 3 Pressure Options - Sub-base Systems Single Pressure Dual Pressure Gasket blanking gallery number 1 3 1 3 1 Three Pressure Gasket blanking galleries 1, 3 and Four Pressure Gasket blanking gallery number 1 Gasket blanking galleries 1, 3 and 3 1 P 3 3 1 P 3 Intermediate Supply Plate P 4 Five Pressure 2 x Twin Supply Gaskets blanking galleries 1, 3 and Gasket blanking galleries 3 and P P 4 3 1 P 3 3 1 P 3 Intermediate Supply Plate P 4 For further pressure configurations contact our Technical Service.4.1.06 N /UK.4.1.06
Nugget 0, V Series Modular Sub-bases for DIN rail or surface mounting 76, 70, 66,6 Modular Sub-base - Side Ported (A) VB17R-Q0G Single Station Modular Sub-base 0,13 Kg 41 1,4 6 Modular Sub-base - Bottom Ported (B) VB17R-Q020G Single Station Modular Sub-base 0,137 Kg E '' 3,7 End Plate Kit - Side Ported (C) VB17R-Q00G 0, Kg Side ported end caps, 1 left hand and 1right hand. Side Ported Sub-base Modules 11, '/' '/' 1,4 24, 3,7 41,7 1,6 1,6 20, C 13,, End Plate Kit - Bottom Ported (D) VB17R-Q01G 0, Kg Bottom ported end caps, 1 left hand and 1right hand. Tie Rod Kits (E) V1B17A-Q04** Weight: (N x 0,003) + 0,004 Kg For assembly of modular sub-base and end plate kit. 2 required. G 1 /4 A 2 4 F C G 130 44 26,6 Right Hand Side Left Hand Side 3 20,4 13, 3,4 (N X 20) + 6.6, Blanking Gasket Set V040-K96 0,006 Kg Set of 3 sub-base to sub-base gaskets for blanking port 1, ports 3 & or ports 1,3 &. Intermediate Supply/Exhaust Plate (F) VB17A-Q240G For additional supply and exhaust. DIN-rail Mounting Kit (G) V3-K30 For mounting on DIN-rail ** = Number of stations - 02 to 16. 0,041 Kg 0,00 Kg 29 B Bottom Ported Sub-base Modules D 23,7 '' '/' '/' G 1 /4,2 7 G 3 / 6 Bottom View 41 11,2 N = Number of stations 6,6 70, 7/9 N /UK.4.1.07
Nugget 0, V Series Modular Sub-base assemblies for DIN rail or surface mounting '' 76, 70, 66,6 41 1,4 6 Modular Sub-base Assemblies Modular Sub-base assemblies for 2 to 16 valves. VCAX**-XXXXX Weight: (N x 0,13) + 0, Kg Side ported VCCX**-XXXXX Weight: (N x 0,0) + 0, Kg Bottom ported ** = 02 to 16 '/' G 3 / '/' 1,4 24, 3,7 41,7 Dual Pressure Modular Sub-base Assemblies Modular Sub-base assemblies for 2 to 16 valves. Allows the supply of two different inlet pressures simultaneously. VCAX**-**XXX Weight: (N x 0,13) + 0, Kg Side ported G 1 /4 2 2 Right Hand Side 4 4 Side Ported Sub-base Assembly Left Hand Side A 11, 1,6 1,6 20, 44 26,6 13, 3,0,4 3 13,, (N X 20) + 6,6, VCCX**-**XXX Weight: (N x 0,0) + 0, Kg Bottom Ported ** = 01 to 1 to indicate position of Dual Pressure Blanking Plate, e.g VBAX03-07XX indicates a station base divided into groups of 3 and 7. DIN-rail Mounting Kit (A) V3-K30 For mounting on DIN-rail 0,00 Kg 29 Bottom Ported Sub-base Assembly 23,7 '' '/' '/' G 1 /4,2 7 Bottom View G 3 / 41 6,6 70, 6 11,2 N = Number of stations N /UK.4.1.0
Nugget 0, V Series Single Station Sub-base - Side Ported 40 46 67 6, 16 Single Station Sub-base V1-G01 0,23 Kg G 1 /4 side ported with pilot ports Ports 1, 2, 3, 4,, and on side Supplied with Internal Pilot Supply Gasket - V23-C01 For Twin Supply Valves, gasket No. V239-C01 supplied with the valves should be used. 3 23 2, 2 6 '' '' 16 2 M 0 Single Station Sub-base - Bottom Ported 67 6, 32 Single Station Sub-base V2-G01 0,23 Kg G 1 4 Bottom ported with pilot ports Ports 1, 2, 3, 4,, and on bottom Supplied with Internal Pilot Supply Gasket - V23-C01 For Twin Supply Valves, gasket No. V239-C01 supplied with the valves should be used. 0 4 46 40 '' '' '' 33 42 M 23 2, 7/9 N /UK.4.1.09
Nugget 0, V Series Fixed Length Manifold 73. 22, 2, 6,6 1,9 A B (2 - Stations) 20 1 30 G 1 /4,2 G 3 / 36,7 63.2 Type No. of stations A B Weight (Kg) V02-G01 1 4-0,1 V02-G02 2 70 60 0,2 V02-G04 4 1 0 0,39 V02-G06 6 0 0,44 V02-G0 0 0,693 V02-G 230 220 0,4 V02-G 0 260 0,997 Supplied with Internal Pilot Supply Gaskets V23-C01. For Twin Supply Valves, gasket No. V239-C01 supplied with the valves should be used. Blanking Plugs For dual pressure supply on Fixed Length Manifold V320-K01 For ports 3 & on Fixed Length Manifold V320-K02 For port 1 on Fixed Length Manifold 0,00 Kg 0,00 Kg Blanking Plate VB17A-Q00 0,0 Kg Blanking Plate for blocking off unwanted station. Supplied with gaskets for Sub-base and Manifold mounting. 1, Intermediate Supply/Exhaust Module VB17-Q240G 0,03 Kg G 1 4. Provides additional porting on Modular Sub-base or Fixed Length Manifold systems. Occupies one valve station. Supplied with gaskets for Sub-base and Manifold mounting.,1.6 '' 37 62 16 Can be used to: Improve supply flow Increase exhaust capacity Pneumatically separate valves on Valve Island for fail safe in emergency Supply and exhaust Twin Supply Valves N /UK.4.1.
Nugget 0, V Series 1 2,4 A DIN Rail Mounting Kits V3 K30 0,00 Kg Kit for mounting side ported modular sub-bases on DIN 467-3, BS and CENELEC EN 0. 022 mounting rail 43 1 DIN-rail V009-C00 1 Metre 0,3 Kg A B C Blanking Gasket Set V040-K96 0,006 Kg For dual or Multi-pressure Supply on Modular Sub-base. Set of 3 sub-base to sub-base gaskets for blanking port 1, ports 3 & or ports 1,3 &. (A) Gasket for blanking ports 1, 3 and. (B) Gasket for blanking port 1 (C) Gasket for blanking ports 3 and. Pressure Indicator VB17A-Q200 0,003 Kg G 1 4 port plug with integral pressure indicator. Replaces standard port plugs. Minimum 3 bar operating pressure. Accessories For Connecting Plugs and Light Emitting Seals see page 7.7.001 Warning These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under Technical Data. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult Norgren. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. 7/9 N /UK.4.1.11