Booster Regulator/Air Tank Increase factory air pressure by up to 4 times! Air-only operation requires no power supply, reduces heat generation, and

Similar documents
Booster Regulator/Air Tank

How to Order. Body size. Pressure: 2 MPa. Pressure increase ratio 0 Twice. Symbol. Thread type. Body size

Booster Regulator/Air Tank

Booster Regulator/Air Tank

Series VBA1110 to 4200

Vacuum Saving Valve Series ZP2V How to Order ZP2V A5 03 Connection thread symbol for the pad Male thread connection Symbol Thread Applicable fixed ori

Air Tank for Booster Regulator Compliant with ASME Standards

30% (SMC comparison) Silencer. New. New. The M5 silencer is now added! The resin silencer is now a more compact size! Series AN.

No.IL02-OM00011-A PRODUCT NAME LOCK UP VALVE. MODEL/ Series IL201 IL211

Industrial Filter. FGD series

Air operated valve. VGA342R Series

Related Products: Auto Drain Valve. Model/Specifications. Model

Booster Regulator/Air Tank Increase factory air pressure by up to 4 times! Air-only operation requires no power supply, reduces heat generation, and

Series IRV1000/2000/3000

VBA1110 to 4200 VBA /4 (IN/OUT) 1/4

PRODUCT NAME. Main Line Filter. MODEL / Series / Product Number

Doc. No.SYJ300-OMO0002-A. Air Operated Valve PRODUCT NAME. SYJA300 / SYJ3000 Series MODEL/ Series

Booster Regulator/Air Tank Increase factory air pressure by up to twice as much! Air-only operation requires no power supply, reduces

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Pressure Relief 3 Port Valve New. Sonic Conductance 45% With the indicator window Step1. With locking holes

Membrane Air Dryer. IDG1-C06 Series IDG1-C06-P Series

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

Chinese Pressure Vessel Regulations Compliant Product Air Tank for Booster Regulator

IR1000-A IR1010-A IR1020-A

5 Port Air Operated Valve

reduces flow setting time and setting errors!

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type.

Direct Operated Precision Regulator Modular Style. Standard Specifications

kpa or less 5.0. Compressed Air Preparation Filter. AFF/AM/AMD Series CAT.ES30-17B. 1 μm (Current model: 3 μm) 20% 60% 52% 160 mm.

5.0 MPa Maximum Supply Pressure. New. Stepless control of air pressure proportional to an electrical signal. Series ITVX CAT.

Moisture Control Tube

Series AMJ. Drain Separator for Vacuum

Filter-Regulator-Lubricator

Lightweight and Compact Type Floating Joint

Power Valve: Precision Regulator. High precision, large capacity relief regulator

Process Pump. Self-priming makes priming unnecessary. Air operated type. Air supply port. 5 port solenoid valves. Application Example

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6

Operation Manual Air Saver Unit ASV5000 Series

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order

435 psi (3.0 MPa) Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. Maximum supply pressure. Set pressure range.

Precision Regulator. Series Model Regulating pressure range Port size Page

VACUUM REGULATORS CONTENTS

Series ZFC. Air Suction Filter In-line Type with One-touch Fittings

Pilot Check Valve: Metal Body Type

EXH. Specifications. Descriptions. Min. working pressure MPa

Process Pump. Series PAF3000/Series PAF5000

Doc. No.VFR3000-OMH0005-B. 5 Port Air Operated Valve PRODUCT NAME. VFRA3000, 4000 Series MODEL/ Series

SeriesTRBU. Flame Resistant (Equivalent to UL-94 Standard V-0) FR Double Layer Polyurethane Tubing

Process Pump. PAF3000 Series/PAF5000 Series

Precision Regulator. IR1000/2000/3000 Series ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV IC ITVH ITVX PVQ VY1 AP100.

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

Compact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Filter-Regulator-Lubricator

Precision Regulator IR3120

Series AS-FPQ/AS-FPG. Speed Controller with One-touch Fitting for Clean Room. Speed controllers for clean room use

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

WHEATLEY Series 500 Swing Check Valve

Regulator. Accessory. Description. Symbol. Nil. With bracket. B With round. Port size. (Without limit indicator) With set nut (For panel mount)

Vacuum Pad with Ejector. Series ZHP

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Push-In Fitting Type Silencer

Increase factory air pressure by up to twice as much! No need for an electrical supply!

Modular Type Regulators

Coiling Tube with Twist-Proof Fitting

ALF400 to 900, ALT-5/-9

PVC Quick Drain Valve

How to Order. Rc NPT 1/8 1/4 3/8 1/2

Series variation. Silencer. High damping effect and 2 types of materials. Applicable cylinder bore size (mm) Effective sectional area (mm 2 )

Change Valve. Push-In Fitting Type Three-way Changeover Valve. Changeover Air Direction by 90. Lightweight and Compact Design.

Technical Data Sheet TI-F50 Locking Units series KFH

Air Saving Valve. Pressure Valve Flow Valve

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

Unit 24: Applications of Pneumatics and Hydraulics

Hand Valve Series. Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Control Open/Close for Air Supply.

5 Port Solenoid Valve

OWNER S TECHNICAL MANUAL

ALF400 to 900, ALT-5/-9

Parallel Seal Type Slit Valve

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

Manual Actuated Boiler Blowdown Valves

Low Friction Cylinders

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

Float Operated Level Controllers

Air preparation units

Low torque Metal seal type Rotary joint

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

Process Pump PB1000A

Pressure booster combination DPA-CRVZS. Operating instructions a [ ]

F.R.L. Units Precautions 1 Be sure to read this before handling.

Relays/Valves. Lock-Up Valve. Series IL201/211/220 EMC.IL A-UK

AMG. Model Note) Rated flow (l/min (ANR)) Port size Mass (kg) 1 8, , 3 8. Specifications Fluid. Element life

Air preparation filter

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Air Amplifiers & SYSTEMS

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order. Option. Symbol.

Type 4708 Supply Pressure Regulator

Transcription:

Booster Regulator/Air Tank Increase factory air pressure by up to 4 times! Air-only operation requires no power supply, reduces heat generation, and Boost pressure allows easy installation. NEW Renewed model with pressure increase ratio 2 to 4 times (VBAA) Factory line 0.3 MPa Booster Regulator + Air Tank 0.6 MPa New Heavy RoHS 0.3 MPa 0.3 MPa Light ompressor 0.3 MPa Light No power supply or wiring needed There is no need to install dedicated electrical wiring. Easy installation Simply insert the unit in the air line. Requires far less space than installing the compressor. Low heat generation Very little heat is generated because no electricity is used, and there is no impact on cylinders, solenoid valves, etc. Air-only operation Operation is safe because no electricity is used. Booster Regulator/Series VBA Series VBA/VBAT Air Tank/Series VBAT AT.ES-96D

Booster Regulator Series VBA Improved service life Doubled that of the conventional model Floating piston structure (PAT. PEND) Grease retaining groove Except VBA0A, A Grease retaining groove Reduced noise Reduced by 3 db (A) compared with the conventional model Metal noise reduced by a bumper on the impact part of the switch valve Exhaust noise reduced by a highnoise reduction silencer Switching valve Floating structure Bumper Improved reliability Anti-condensation Built-in mesh filter at Prevents operation failure due to foreign matter. Mesh filter Integrated air-feeding tube with the main tube Mitigates condensation caused by cooling during exhaust expansion. ylinder tube Tie-rod guide Air-feeding tube VBA20A NEW Elbow silencer added (Option) Space saving when installed has been realized. Except VBA2A, 4A Elbow silencer /8" gauge ports VBA40A Allows use of standard fittings for remote pressure monitoring, etc. Gauge ports changed from /6" to /8" (VBAA, 2A) VBA0A Gauge port Air-operated type Max. operating pressure.6 MPa Fourfold pressure increase type NEW VBA22A VBA43A VBAA Features VBA42A

P. Pressure increase ratio Twice 2 to 4 times Body size Operation Set pressure range 0.2 to.0 MPa Handle-operated type (Direct operation) 0.2 to.6 MPa (2.0 MPa) Air-operated type (Remote operation) 0.2 to.0 MPa Handle-operated type (Direct operation) 0.2 to 2.0 MPa VBA0A-02 (0.2 to 2.0 MPa) VBAA-02 /4" VBA20A-03 VBA22A-03 3/8" VBA40A-04 VBA43A-04 (0.2 to.6 MPa) VBA42A-04 /2" Air Tank Series VBAT P. 2 Perfect fit with a booster regulator This is an air tank to which a booster regulator can be connected compactly. It can be used alone as a tank. The pressure vessel law is different from country to country, so as an air tank suitable to a country needs to be confirmed. Extensive product lineup To meet a variety of usage environment and pressure specifications, models are available in two materials, stainless steel 304 and carbon steel (SS400), and in four sizes ranging from 5 liters to 38 liters. Model Tank capacity (L) Max. operating pressure (MPa) Material VBAT05A VBAT0A VBAT20A VBAT38A 5 0 20 38 2.0.0 arbon steel Model VBAT05S VBAT0S VBAT20S VBAT38S Tank capacity (L) Max. operating pressure (MPa) Material 5 0 20 2.0 Stainless steel 38 aution When used as a single unit (not connected with a booster regulator) and pressurized at over MPa at normal temperatures, the air tank falls under the scope of the High Pressure Gas Safety Act in Japan. Features 2

Booster Regulator Series VBA How to Order RoHS Made to Order (For details, refer to page.) 0A 20A 40A 22A 42A 43A A /4", Handle-operated type 3/8", Handle-operated type /2", Handle-operated type 3/8", Air-operated type /2", Air-operated type /2", Max. operating pressure.6 MPa /4", Handle-operated type Symbol VBA0A-02 VBAA-02 VBA 40A 04 Body size Pressure increase ratio: Twice Pressure increase ratio: 2 to 4 times Thread type Note) Symbol Thread type Nil Rc F G N NPT T NPTF Note) Thread types apply to the IN,, and EXH ports of the VBAA and to the IN,, EXH, and gauge ports of the VBA2A and VBA4A. The gauge ports of the VBAA are Rc thread type regardless of the thread type indication. Symbol 02 03 04 Port size /4 3/8 /2 Port size Applicable series VBAA VBA2A VBA4A Semi-standard Symbol Semi-standard Nil Standard product Pressure unit on the product name Z Note) label and pressure gauge: psi Note) Thread type: NPT, NPTF Under the new measurement law, the pressure unit of psi on the pressure gauges cannot be used in Japan. Option Symbol Option Nil None G Pressure gauge N Silencer S High-noise reduction silencer Note) GN Pressure gauge, Silencer GS Pressure gauge, High-noise reduction silencer Note) LN Elbow silencer Note) LS Elbow high-noise reduction silencer Note) GLN Pressure gauge, Elbow silencer Note) GLS Pressure gauge, Elbow high-noise reduction silencer Note) Note) Refer to ombination of Thread Type and Options. Pressure gauge Pressure gauge Silencer Elbow silencer VBA20A-03 VBA22A-03 ombination of Thread Type and Options Body size 0A A 20A 22A 40A 42A 43A Thread type Nil F N T Nil F N T Nil F N T Nil G N S Option GN GS LN LS GLN Semi-standard GLS Nil -Z VBA42A-04 VBA40A-04 VBA43A-04 Air Tank ompatibility hart Booster regulator Air tank VBAA VBA2A VBAT05A VBAT05S VBAT0A VBAT0S VBAT20A VBAT20S VBAT38A VBAT38S VBA4A

Booster Regulator Series VBA Standard Specifications Model Fluid Pressure increase ratio Pressure adjustment mechanism Max. flow rate Note 2) (L/min (ANR)) Set pressure range (MPa) Supply pressure range (MPa) Proof pressure (MPa) Port size (Rc) (IN//EXH: 3 locations) Pressure gauge port size (Rc) (IN/: 2 locations) /8 Ambient and fluid temperature ( ) 2 to (No freezing) Installation Horizontal Lubrication Grease (Non-lube) Weight (kg) 0.84 3.9 8.6 3.9 8.6 8.6 0.89 Note ) If the pressure is higher than the set pressure by the handle, excess pressure is exhausted from the back of the handle. Note 2) Flow rate at IN= = 0.5 MPa. The pressure varies depending on the operating conditions. Refer to Flow-rate haracteristics on pages 3 and 4. Options/Part No. Related Products/Part No. Model Description Mist separator Exhaust cleaner For VBA0A-02 For VBAA-02 AM2-02 AM30-03 For VBA20A-03 For VBA22A-03 AM4-04, 06 AM-06 For VBA40A-04 For VBA42A-04 For VBA43A-04 AM5-06, 0 AM-0 Note) Refer to page 2 for air tanks, Best Pneumatics No. 5 for mist separators and Best Pneumatics No. 6 for exhaust cleaners. Refer to the separate operation manual for the connection method. VBA0A-02 VBA20A-03 VBA40A-04 VBA22A-03 VBA42A-04 VBA43A-04 VBAA-02 ompressed air Twice 2 to 4 times Handle-operated with relief mechanism Note ) Air-operated 230 0.2 to 2.0 Pressure Gauge, Silencer (When thread type is Rc or G.) Model VBA0A-02 VBA20A-03 VBA40A-04 VBA0A-F02 VBA20A-F03 VBA40A-F04 Description Pressure gauge Silencer High-noise reduction silencer Elbow for silencer G N S L 3 /4 G27-20-0 AN200-02 ANA-02 KT-VBA0A-8 000 900 000 900 0 70 0.2 to.0 0.2 to.0 0.2 to.6 0.2 to 2.0 0. to.0.5 2.4 3 3/8 AN300-03 ANA-03 G36-0-0 /2 AN400-04 ANA-04 VBA22A-03 VBA22A-F03 KT-VBA22A-7 AN300-03 ANA-03 aution 3/8 /2 VBA42A-04 VBA42A-F04 G36-0-0 AN400-04 ANA-04 Note ) In the case of options GN, two pressure gauges and one silencer are included in the same container as accessories. Note 2) KT-VBA22A-7 is a pressure gauge with fitting. (Please order two units when using with IN and.) Pressure Gauge, Silencer (When thread type is NPT or NPTF.) Model VBA0A-N02 VBA20A-N03 VBA40A-N04 VBA0A-T02 VBA20A-T03 VBA40A-T04 : when -Z : when -Z : when -Z Description Pressure gauge : when Nil G Pressure gauge : when -Z Note 4) Silencer N High-noise reduction silencer S Elbow for silencer L G27-20-0 G27-P20-0 AN200-N02 KT-VBA0A-8N VBA22A-N03 VBA22A-T03 : when -Z VBA42A-N04 VBA42A-T04 : when -Z Note ) In the case of options GN, two pressure gauges and one silencer are included in the same container as accessories. Note 2) KT-VBA22A-7N, KT-VBA22A-8N are pressure gauges with fittings. (Please order two units when using with IN and.) Note 3) Under the new measurement law, the pressure unit of psi on the pressure gauges cannot be used in Japan. Note 4) Pressure unit on the pressure gauge: psi Mist Separator, Exhaust leaner AN300-N03 ANA-N03 G36-0-N0 G36-P0-N0 AN400-N04 ANA-N04 KT-VBA22A-7N KT-VBA22A-8N AN300-N03 ANA-N03 G36-0-N0 G36-P0-N0 AN400-N04 ANA-N04 Design Handle-operated with relief mechanism Note ) VBA43A-04 VBA43A-F04 G27-20-0 AN400-04 ANA-04 VBA43A-N04 VBA43A-T04 : when -Z G27-20-N0 G27-P20-N0 AN400-N04 ANA-N04. System configuration The of the booster regulator has metallic mesh to prevent dust from entering the booster regulator. However, it cannot remove dust continuously or separate drainage. Make sure to install a mist separator (AM series) on the inlet side of the booster regulator. The booster regulator has a sliding part inside, and it generates dust. Also, install an air purification device such as an air filter or a mist separator on the outlet side as necessary. onnect a lubricator to the outlet side, because the accumulated oil in the booster regulator may result in a malfunction. 2. Exhaust air measures Provide a dedicated pipe to release the exhaust air from each booster regulator. If exhaust air is converged into a pipe, the back pressure that is created could cause improper operation. Depending on the necessity, install a silencer or an exhaust cleaner on the exhaust port of the booster regulator to reduce the exhaust noise. 3. Maintenance space Allow the sufficient space for maintenance and inspection. 2 /4 VBAA-02 VBAA-F02 G27-20-0 AN200-02 ANA-02 KT-VBA0A-8 VBAA-N02 VBAA-T02 : when -Z G27-20-0 G27-P20-0 AN200-N02 KT-VBA0A-8N

Series VBA VBA0A Flow-rate haracteristics 2 VBA20A, 22A Flow-rate haracteristics.0 VBA40A, 42A Flow-rate haracteristics.0 Outlet pressure (MPa).5 0.5 P =.0 MPa P = 0.75 MPa P = 0.5 MPa P = 0.4 MPa P = 0.3 MPa P = P2 Outlet pressure (MPa) 0.8 0.6 0.4 0.2 P = 0.3 MPa P = 0.5 MPa P = 0.4 MPa Outlet pressure (MPa) 0.8 0.6 0.4 0.2 P = 0.5 MPa P = 0.4 MPa P = 0.3 MPa. 0 00 200 300 400 Outlet air flow rate (L/min (ANR)) Pressure haracteristics Inlet pressure: 0.7 MPa Outlet pressure:.0 MPa Flow rate: 20 L/min (ANR) (Representative value).04 0 200 400 0 800 000 200 Outlet air flow rate (L/min (ANR)) Pressure haracteristics Inlet pressure: 0.7 MPa Outlet pressure:.0 MPa Flow rate: 20 L/min (ANR) (Representative value).04 0 0 000 0 2000 Outlet air flow rate (L/min (ANR)) Pressure haracteristics Inlet pressure: 0.7 MPa Outlet pressure:.0 MPa Flow rate: 20 L/min (ANR) (Representative value).05 Set point.02 Set point.02 Set point Outlet pressure (MPa).0 0.95 0.9 0.85 Outlet pressure (MPa).0 0.98 0.96 Outlet pressure (MPa).0 0.98 0.96 0.8 0.94 0.94 0 0.4 0.5 0.6 0.7 0.8 0.9 Inlet pressure (MPa) 0 0.4 0.5 0.6 0.7 0.8 0.9 Inlet pressure (MPa) 0 0.4 0.5 0.6 0.7 0.8 0.9 Inlet pressure (MPa) harge haracteristics harge time per 0 L t (s) 40 30 20 0 0.0.2.4.6.8 2.0 Pressure increase ratio P2/P harge haracteristics harge time per 0 L t (s) 2 0 9 8 7 6 5 4 3 2 0.0..2.3.4.5.6.7.8.9 2.0 Pressure increase ratio P2/P VBA0A VBA20A, 22A The time required to charge pressure in the The time required to charge pressure in the tank from 0.7 MPa to 0.95 MPa at 0.5 MPa tank from 0.8 MPa to.0 MPa at 0.5 MPa supply pressure: supply pressure: P2 0.7 P2 0.95 P2 0.8 P2.0 = =.4 = =.9 = =.6 = P 0.5 P 0.5 P 0.5 P 0.5 = 2.0 With the pressure increase ratio from.4 to.9, the charge time of 23 6 = 7 sec. (t) is given by the graph. Then, the charge time (T) for a 0 L tank: V 0 T = t x = 7 x = 7 (s). 0 0 With the pressure increase ratio from.6 to 2.0, the charge time of.5 3.8 = 7.7 sec. (t) is given by the graph. Then, the charge time (T) for a 00 L tank: V 00 T = t x = 7.7 x = 77 (s). 0 0 harge haracteristics harge time per 0 L t (s) 5 4 3 2 0.0..2.3.4.5.6.7.8.9 2.0 Pressure increase ratio P2/P VBA40A, 42A The time required to charge pressure in the tank from 0.8 MPa to.0 MPa at 0.5 MPa supply pressure: P2 0.8 P2.0 = =.6 = = 2.0 P 0.5 P 0.5 With the pressure increase ratio from.6 to 2.0, the charge time of 3.5. = 2.4 sec. (t) is given by the graph. Then, the charge time (T) for a 00 L tank: V 00 T = t x = 2.4 x = 24 (s). 0 0 3

Booster Regulator Series VBA VBA43A Flow-rate haracteristics Outlet pressure (MPa) Outlet pressure (MPa) harge time per 0 L t (s).6.4.2 0.8 0.6 0.4 0.2.08.06.04.02.0 0.98 0.96 0.94 5 4 3 2 0 0 000 0 2000 20 3000 Outlet air flow rate (L/min (ANR)) Pressure haracteristics 0 0.4 0.5 0.6 0.7 0.8 0.9 Inlet pressure (MPa) harge haracteristics VBA43A P = 0.8 MPa P = 0.7 MPa P = 0.6 MPa P = 0.5 MPa P = P2 Inlet pressure: 0.7 MPa Outlet pressure:.0 MPa Flow rate: 20 L/min (ANR) Set point (Representative value) 0.0..2.3.4.5.6.7.8.9 2.0 Pressure increase ratio P2/P The time required to charge pressure in the tank from 0.8 MPa to.0 MPa at 0.5 MPa supply pressure: P2 0.8 P2.0 = =.6 = = 2.0 P 0.5 P 0.5 With the pressure increase ratio from.6 to 2.0, the charge time of 4.5.3 = 3.2 sec. (t) is given by the graph. Then, the charge time (T) for a 00 L tank: V 00 T = t x = 3.2 x = (s). 0 0 VBAA Flow-rate haracteristics Outlet pressure (MPa) Outlet pressure (MPa) harge time per 0 L t (s) 2 2. 2.05 2.0.95.9.85.8 400 300 200 00 P = 0.3 MPa P = 0.4 MPa 0 00 Outlet air flow rate (L/min (ANR)) Pressure haracteristics P = 0.5 MPa Set point P = 0.75 MPa Inlet pressure: 0.6 MPa Outlet pressure: 2.0 MPa Flow rate: 0 L/min (ANR) 0 0.4 0.5 0.6 0.7 0.8 0.9 Inlet pressure (MPa) harge haracteristics P =.0 MPa P = P2 (Representative value) 0.0 2.0 3.0 4.0 Pressure increase ratio P2/P VBAA The time required to charge pressure in the tank from.0 MPa to.5 MPa at 0.5 MPa supply pressure: P2.0 P2.5 = = 2.0 = = 3.0 P 0.5 P 0.5 With the pressure increase ratio from 2.0 to 3.0, the charge time of 47 58 = 89 sec. (t) is given by the graph. Then, the charge time (T) for a 0 L tank: V 0 T = t x = 89 x = 89 (s). 0 0 Pulsation/Pulsation is decreased with a tank. If the outlet capacity is undersized, pulsation may occur. VBAT05A Max. pulsation range (MPa) Max. pulsation range (MPa) 0. 0.08 0.06 0.04 0.02 0. 0.08 0.06 0.04 0.02 0 2 3 4 5 apacity (L) VBAA 0 0 20 30 38 40 apacity (L) VBA2A VBA4A VBAT VBAT0A, 20A, 38A VBAT0A onditions: Inlet pressure: 0.5 MPa Outlet set pressure: MPa Flow rate: Between 0 and max. flow rate VBAT05A VBAT20A VBAT38A VBAT Performance of air tank Alleviates the pulsation generated on the outlet side. When air consumption exceeds air supply during intermittent operation, required air will be accumulated in the tank for use. This does not apply for continuous operation. 4

Series VBA Sizing can be achieved with the SM Pneumatic System Energy Saving Program Ver. 3. Sizing ( which can be downloaded from the SM website: http://www.smcworld.com/ ) Tc Ts START Provide requisite conditions for selection. alculate required air flow rate Q. Select booster regulator size from flow-rate characteristics table. P P3 P2 Necessary conditions: D [mm]: ylinder bore size L [mm]: ylinder stroke W [mm/s]: ylinder operating speed [pc.]: Number of cylinders Tc [s]: ylinder operating time Ts [s]: ylinder stop time P [MPa]: Inlet pressure P2 [MPa] Note ) : Necessary supply pressure to cylinder ød Example 00 00 200 0.5 30 0.5 0.8 L Pressure Stroke Upper limit of pressure inside the tank P3 Necessary supply pressure to cylinder P2 Lower limit of pressure inside the tank P2 Inlet pressure P Time Other conditions: Q [L/min (ANR)]: Required air flow rate Qb [L/min (ANR)]: Outlet air flow rate of booster regulator Tc [s]: ylinder operating time K: ylinder double-acting: 2, single-acting: P3 [MPa] Note 2) : Tank charge pressure T [s]: Time to charge (Time to charge to P2) T2 [s]: Time to charge (Time to charge to P3) T [s]: Time to charge (Time to charge from P2 to P3) Z: Number of booster regulators Note ) P2 is the necessary supply pressure to a cylinder, and set the pressure below the lower limit of pressure inside the tank with a regulator. Adjust the pressure taking the maximum operating pressure of equipment in use into consideration. Note 2) P3 is the output pressure of the booster regulator, which is also the upper limit of charge pressure to the tank. Q [L/min (ANR)] = π x D2 x W x (P2 + 0.0) x x 4 x 0 6 0.0 Q = π x 002 x 200 (0.8 + 0.0) x x x = 84 [L/min (ANR)] 4 x 0 6 0.0 VBA2A: Qb = 0 [L/min (ANR)] VBA4A: Qb = 0 [L/min (ANR)] Refer to Flow-rate haracteristics on pages 3 and 4. aution Use the VBAA (pressure increase ratio 4) with pressure increase ratio 2 to 4. Usage of pressure increase ratio below 2 is preferred for the VBA0A (pressure increase ratio 2). A stable operation and increased life expectancy will result. Inlet supply pressure volume is {approximately twice (pressure increase ratio 2), approx. 4 times (pressure increase ratio 4)} the volume of the outlet side. requires the inlet side volume which is the sum of the flow volume running into the outlet side and the volume exhausted from E port (for driving), because air is the power source. Judgement of flow rate NO: Need no tank The VBA4A can supply necessary pressure. Avoid pulsation. (Max. 0.05 MPa) NO YES The VBA2A cannot obtain necessary pressure. YES Obtain the tank capacity V. Select the tank capacity over V. (Q Qb/2) x (Tc x K/) V [L] = (P3 P2) x 9.9 (84 0/2) x (0.5 x 2/) V = = 4.6 [L] (.0 0.8) x 9.9 Select the VBAT0, which can be directly connected to the VBA2A. Tank model VBAT05 VBAT0 VBAT20 VBAT38 Internal capacity 5 L 0 L 20 L 38 L Select the tank from table below. Applicable combination model VBAA VBAA VBA2A VBA2A VBA2A VBA4A VBA4A alculate time T from charge characteristics table. Refer to harge haracteristics on pages 3 and 4. T [s] = ( V )x 0 T2 T Z 4.6.5 3.8 T = ( ) x = 3.5 [s] 0 Judgement of charge time T Ts NO Extend stop time Ts up to charge time T or more. NO Increase number of booster regulators (Z) to decrease T. YES YES YES 5 END When running continuously for longer periods of time, confirm the life expectancy. When the life expectancy is shorter than required, select a larger sized booster regulator.

Booster Regulator Series VBA Working Principle The IN air passes through the check valve to booster chambers A and B. Meanwhile, air is supplied to drive chamber B via the governor and the switching valve. Then, the air pressure fromdrive chamber B and booster chamber A are applied to the piston, boosting the air in booster chamber B. As the piston travels, the boosted air is pushed via the check valve to the side. When the piston reaches to the end, the piston causes the switching valve to switch, so that drive chamber B is in the exhaust state and drive chamber A is in the supply state respectively. Then, the piston reverses its movement, this time, the pressures from booster chamber B and drive chamber A boosts the air in booster chamber A and sends it to the side. The process described above is repeated to continuously supply highly pressurized air from the IN to the side. The governor establishes the outlet pressure by handle operation and pressure adjustment in the drive chamber by feeding back the outlet pressure. Air-operated type VBA0A, 20A, 40A, 43A Pilot pressure VBAA Drive Governor chamber A Booster chamber A IN (Inlet) Drive chamber B Piston rod Piston VBA22A, 42A Piston rod Booster chamber A Piston IN (Inlet) Governor Drive chamber A Drive chamber B heck valve Switching valve E (Outlet) ircuit Example Booster chamber B Booster heck valve chamber B (Outlet) E Switching valve When only some of the machines in the plant require high-pressure air, booster regulators can be installed for only the equipment that requires it. This allows the overall system to use low-pressure air while accommodating machines requiring high-pressure air. General line (low pressure) Locations requiring high pressure VBA When the actuator output is insufficient but space limitations prohibit switching to a larger cylinder diameter, a booster regulator can be used to increase the pressure. This makes it possible to boost the output without replacing the actuator. When a certain level of output is required but the cylinder size must be kept small so that the driver remains compact. Plant line (source pressure) VBA VBA (Two-stage pressure boost) VBA When charging a tank or the like from a source at atmospheric pressure, a circuit with a check valve can be used to reduce the charge time by allowing air to pass through the check valve up to the inlet pressure. 0.5 MPa ø00 Operating pressure: 0.5 MPa Bore size: ø00 Output 38 N Equivalent output 0.8 MPa IN 0.5 MPa ø80 E Operating pressure: 0.8 MPa Bore size: ø80 Output 4000 N When only one side of the cylinder is used for work, booster regulators can be installed only on the lines that require them to reduce the overall air consumption volume. P P2 Initially, inlet pressure (P) passes through the check valve, fills P2, and results in P = P2. Outlet pressure (MPa) P2 P Shortening time Without check valve by-pass 0 Time t (S) 6

Series VBA Warning Design. Warning concerning abnormal outlet pressure If there is a likelihood of causing an outlet pressure drop due to unforeseen circumstances such as equipment malfunction, thus leading to a major problem, take safety measures on the system side. Because the outlet pressure could exceed its set range if there is a large fluctuation in the inlet pressure, leading to unexpected accidents, take safety measures against abnormal pressures. Operate the equipment within its maximum operating pressure and set pressure range. 2. Residual pressure measures onnect a 3-port valve to the side of the booster regulator if the residual pressure must be released quickly from the outlet pressure side for maintenance, etc. (Refer to the diagram below.) The residual outlet pressure side cannot be released even if the 3-port valve is connected to the IN side because the check valve in the booster regulator will activate. After operation is finished, release the supply pressure at the inlet. This stops the booster regulator from moving needlessly and prevents operating malfunctions. aution Mounting. Transporting When transporting this product, hold it lengthwise with both hands. Never hold it by the black handle that protrudes from the center because the handle could become detached from the body, causing the body to fall and leading to injury. 2. Installation Install this product so that the silver-colored tie-rods and cover are placed horizontally. If mounted vertically, it may result in a malfunction. Because the piston cycle vibration is transferred, use the following mounting bolts (VBA: M5; VBA2, 4: M0) and tighten them with the specified torque (VBA: 3 N m; VBA2, 4: 24 N m). If the transmission of vibration is not preferred, insert an isolating rubber material before installation. Mount the pressure gauge with a torque of 7 to 9 N m. aution Piping. Flushing Use an air blower to flush the piping to thoroughly remove any cutting chips, cutting oil, or debris from the piping inside, before connecting them. If they enter the inside of the booster regulator, they could cause the booster regulator to malfunction or its durability could be affected. 2. Piping size To bring the booster regulator s ability into full play, make sure to match the piping size to the port size. aution Selection. heck the specifications. onsider the operating conditions and operate this product within the specification range that is described in this catalog. 2. Selection Based on the conditions (such as pressure, flow rate, takt time) required for the outlet side of the booster regulator, select the size of the booster regulator in accordance with the selection procedures described in this catalog or model selection program. Use the VBAA (pressure increase ratio 4) with pressure increase ratio 2 to 4. Usage of pressure increase ratio below 2 is preferred for the VBA0A (pressure increase ratio 2). A stable operation and increased life expectancy will result. Inlet supply pressure volume is {approximately twice (pressure increase ratio 2), approx. 4 times (pressure increase ratio 4)} the volume of the outlet side. Booster regulator requires the inlet side volume which is the sum of the flow volume running into the outlet side and the volume exhausted from E port (for driving), because air is the power source. When running continuously for longer periods of time, confirm the life expectancy. The life expectancy of a booster regulator is dependent upon the operational cycle. Thus, when used for driving cylinders, etc. in the outlet side, life expectancy will be reduced. Make sure the outlet pressure is set 0. MPa or higher than the inlet pressure. A pressure difference below 0. MPa makes the operation unstable and may result in a malfunction. 7 aution Air Supply. Quality of air source onnect a mist separator to the inlet side near the booster regulator. If the quality of the compressed air is not thoroughly controlled, the booster regulator could malfunction (without being able to boost) or its durability could be affected. If dry air (atmospheric pressure dew point: 7 or less) is used, the life expectancy may be shortened because dry air will accelerate evaporation of grease inside. aution Operating Environment. Installation location Do not install this product in an area that is exposed to rainwater or direct sunlight. Do not install in locations influenced by vibrations. If it must be used in such an area due to unavoidable circumstances, please contact SM beforehand.

Booster Regulator Series VBA aution. Setting the pressure on the handle-operated type If air is supplied to the product in the shipped state, the air will be released. Set the pressure by quickly pulling up on the governor handle, releasing the lock, and rotating the handle in the direction of the arrow (+). There is an upper and lower limit for the handle rotation. If over-rotating the handle even after reaching to the limit, the internal parts may be damaged. If the handle suddenly feels heavy while being turned, stop turning the handle. Once the setting is completed, push the handle down and lock it. To decrease the outlet pressure, after the pressure has been set, rotate the handle in the direction of the arrow ( ). The residual air will be released from the area of the handle, due to the relief construction of the governor. To reset the pressure, first reduce the pressure so that it is lower than the desired pressure; then, set it to the desired pressure. Low SM High 2. Setting the pressure on the air-operated type (VBA22A, 42A) onnect the outlet pipe of the pilot regulator for the remote control to the pilot port (P). (Refer to the diagram below.) Refer to the graph below for the relationship between the pilot pressure and outlet pressure. The AR20 and AW20 are recommended for the pilot regulator. Pilot regulator Handling 3. Draining If this product is used with a large amount of drainage accumulated in the filter, mist separator or tank, the drainage could flow out, leading to equipment malfunction. Therefore, drain the system once a day. If it is equipped with an auto drain, check its operation once a day. 4. Exhaust Exhausting time from E port may be longer for a booster regulator which is set to switch in longer hour intervals. This is not an abnormal phenomenon. 5. Maintenance Life expectancy varies depending on the quality of air and the operating conditions. Signs that the unit is reaching the end of its service life include the following: onstant bleed from under the handle. Air exhaust noise can be heard from the booster regulator at 0 to 20 second intervals even when there is no air consumption on the outlet side. onduct maintenance earlier than scheduled in such cases. When maintenance is required, confirm the model and serial number of the booster regulator, and please contact SM for maintenance kit. onduct maintenance according to the specified maintenance procedure by individuals possessing enough knowledge and experiences in maintaining pneumatic equipment. The list of replacement parts and kit number are shown on page 9, and the figure shows the position of the parts. The outlet pressure is twice the pilot pressure. When the inlet pressure is 0.4 MPa: Pilot pressure 0.2 MPa to 0.4 MPa 0.9 Outlet pressure 0.8 0.4 MPa to 0.8 MPa 0.7 Outlet pressure MPa (Q = 0) 0.6 0.5 0.4 0.3 0.2 0. 0 0. 0.2 0.3 0.4 0.5 Pilot pressure MPa 8

Series VBA onstruction/replacement Parts VBA0A VBAA q r e w t u r e w t q VBA20A, 22A, VBA40A, 42A, 43A Air-operated type q t q y r w e VBA22A, 42A Replacement Parts/Kit No. Place an order with the following applicable kit number. Model VBA0A VBA20A VBA40A VBA22A VBA42A VBA43A VBAA Kit no. KT-VBA0A- KT-VBA20A- KT-VBA40A- KT-VBA22A- KT-VBA42A- KT-VBA43A- KT-VBAA-20 The kit includes the parts from q to u and a grease pack. No. Model VBA0A VBA20A VBA40A VBA22A VBA42A VBA43A Description Quantity Piston seal 2 2 large small 2 2 Governor assembly 3 heck valve 4 4 5 6 Gasket Rod seal Mounting screw 8 2 2 8 2 7 over assembly Grease pack 2 2 The grease pack has 0 g of grease. Make sure to refer to the procedure for maintenance. 9 VBAA each large and small 2

Booster Regulator Series VBA Dimensions VBA0A-02 IN side gauge port Rc /8 Pressure gauge (Option) side gauge port Rc /8 3 23 27 port 7 28 Silencer (Option) 22 With elbow silencer (Option) 3 23 27 port Elbow silencer (Option) 7 28 22 VBAA-02 IN side gauge port Rc /8 40 33 30 8.5 Pressure gauge (Option) side gauge port Rc /8 3 23 27 4 x ø5.5 70 EXH port (When silencer installed: 25) (When high-noise reduction silencer installed: 26) port 7 28 Silencer (Option) 22 4 x ø5.5 70 (97) EXH port With elbow silencer (Option) 3 23 27 port Elbow silencer (Option) 7 28 22 VBA20A-03 40 8.5 300 39 Pressure gauge (Option) 4 x ø5.5 EXH port 70 (When silencer installed: 25) (When high-noise reduction silencer installed: 26) 28 4 x ø5.5 70 (97) EXH port IN side gauge port Rc /8 side gauge port Rc /8 76 43 46 port 2 5 Silencer (Option) 24 VBA40A-04 IN side gauge port Rc /8 53 73 404 40 3.2 Pressure gauge (Option) side gauge port Rc /8 4 x ø2 98 EXH port 8 (When silencer installed: 79) (When high-noise reduction silencer installed: 79) 43 25 62.8 62 port 22 8 Silencer (Option) 96 6 3.2 4 x ø2 30 EXH port (When silencer installed: 224) (When high-noise reduction silencer installed: 230) 0

Series VBA Dimensions VBA22A-03 IN side gauge port Rc /8 300 39 Pressure gauge (Option) side gauge port Rc /8 28 39 43 46 port 2 5 Silencer (Option) 24 VBA42A-04 IN side gauge port Rc /8 53 73 3.2 404 40 Pressure gauge (Option) side gauge port Rc /8 4 x ø2 98 8 EXH port (When silencer installed: 79) (When high-noise reduction silencer installed: 79) 43 72 62 62.8 port 22 8 Silencer (Option) VBA43A-04 IN side gauge port Rc /8 96 6 404 40 3.2 Pressure gauge (Option) side gauge port Rc /8 4 x ø2 30 EXH port (When silencer installed: 224) (When high-noise reduction silencer installed: 230) 43 22 62 62.8 port 22 8 Silencer (Option) 96 6 3.2 4 x ø2 30 EXH port (When silencer installed: 224) (When high-noise reduction silencer installed: 230) Made to Order For detailed dimensions, specifications and lead times, please contact SM. opper-free/fluorine-free 2 E explosion-proof directive (ATEX) compliant 3 Ozone resistant The inner or outer copper parts material has been changed to stainless steel or aluminum. The fluorine resin parts has been changed to general resin. 20 Made to Order opper-free/fluorine-free 56 For booster regulator with pressure gauge, please consult SM. This option cannot be selected for air tank with safety valve. Standard model no. Standard model no. Made to Order E explosion-proof directive (ATEX): ategory 3GD Ozone resistance is strengthened through the use of fluororubber (diaphragm) and hydrogenated NBR (valve, rod seal) for the rubber parts of the seal material. 80 Standard model no. Made to Order Ozone resistant Weather resistant NBR (diaphragm) and hydrogenated NBR (valve) are used for the rubber parts of the standard model.

Air Tank Series VBAT How to Order RoHS Made to Order (For details, refer to page.) ompact connections are possible with booster regulators. It can be used alone as a tank. Also partially compatible with overseas standards VBAT05A VBAT20S VBAT0S VBAT38A aution When used as a single unit (not connected with a booster regulator) and pressurized at over MPa at normal temperatures, the air tank falls under the scope of the High Pressure Gas Safety Act in Japan. Standard Product (For Japanese Market) VBAT 0 A Tank internal capacity Symbol Internal capacity 05 5 L 0 0 L 20 20 L 38 38 L Material Symbol Material A arbon steel (SS400) S Stainless steel 304 E ertified Product VBAT 0 Tank internal capacity Symbol Internal capacity 05 5 L 0 0 L 20 20 L 38 38 L A Material Symbol Material A arbon steel (SS400) F Product Not Applicable to the ASME Standard Tank internal capacity Symbol Internal capacity 05 5 L 0 0 L Material Symbol Material A arbon steel (SS400) Thread type Symbol Thread type Nil Rc N NPT Note) S Note) The thread type for each port is Rc. Option Symbol Nil V Option None Drain valve Option Symbol Option Applicable model Nil None Note) All models R Safety valve VBAT05A, VBAT0A (Set pressure: MPa) VBAT20A, VBAT38A S Safety valve VBAT05A (Set pressure: 2 MPa) VBAT0A Note) A safety valve port is provided only when option R or S is selected. SV Q E certified product (Self-declaration document attached) Accessories Symbol Accessories Safety valve (Set pressure: MPa) RV Drain valve Safety valve (Set pressure: 2 MPa) SV Drain valve Thread type Symbol Nil F VBAT 05 A N Thread type Rc G SV Note) Pressure unit of NPT products: psi. This product is for overseas use only according to the new Measurement Law. (The SI unit type is provided for use in Japan.) X Applicable model VBAT20A VBAT38A VBAT05A VBAT0A Product not applicable to the ASME standard Option Symbol Option Nil None Note ) V Drain valve Note ) S Safety valve (Set pressure: 2 MPa) Note ) Safety valve (Set pressure: 2 MPa) Note 2) SV Drain valve Note ) ustomers are responsible for preparing a safety valve. Note 2) Safety valve does not meet ASME specifications. 2

Series VBAT Specifications Standard Product (For Japanese Market) Model VBAT05 VBAT0 VBAT20 VBAT38 Fluid Tank capacity (L) Max. operating pressure (MPa) VBATA VBATS size port size 3/8 3/8 3/8 /2 /2 /2 /2 3/4 Ambient and fluid temperature ( ) 0 to 75 Weight (kg) Material Paint VBATA VBATA VBATA 6.6 arbon steel (SS400) Outside: Silver paint, Inside: Rustproof paint 0 4 2 VBATS VBATS VBATS 3.2 Stainless steel 304 None 4.9 2 9 Note) The accessories and options are included in the same container. E ertified Product Model 5 VBAT05A -SV-Q ompressed air 0 20 2.0.0 2.0 VBAT0A -SV-Q VBAT20A -RV-Q 38 VBAT38A -SV-Q Fluid ompressed air Tank capacity (L) 5 0 20 38 Max. operating pressure (MPa) 2.0.0 size port size 3/8 3/8 /2 /2 3/4 /2 3/4 3/4 Ambient and fluid temperature ( ) 0 to 75 Weight (kg) 6.6 0 4 2 Material Paint arbon steel (SS400) Outside: Silver paint, Inside: Rustproof paint Note) The accessories and options are included in the same container. Product Not Applicable to the ASME Standard Model VBAT05A--X VBAT0A--X Fluid ompressed air Tank capacity (L) 5 0 Max. operating pressure (MPa) 2.0 size port size 3/8 3/8 3/8 /2 Ambient and fluid temperature ( ) 0 to 75 Weight (kg) 6.6 Material Paint arbon steel (SS400) Outside: Silver paint, Inside: Rustproof paint Note) The accessories and options are included in the same container. 3 Warning. Operating pressure Operate this product below the maximum operating pressure. If it is necessary, take appropriate safety measures to ensure that the maximum operating pressure is not exceeded. When the tank alone is used Use a pressure switch or a safety valve to ensure that the maximum operating pressure is not exceeded. 2. onnection onnect a filter or a mist separator to the side of the tank. Because the inner surface of the tank is untreated, there is a possibility of dust flowing out to the outlet side. A VBA booster regulator can be connected directly with the tank accessories as indicated combinations below. Air tank VBAT05A VBAT05S VBAT0A VBAT0S VBAT20A VBAT20S VBAT38A VBAT38S aution Design VBAA Selection VBA2A VBA4A onsider the operating conditions and operate this product within the specification range. When using the air tank with a booster regulator, refer to Sizing on page 5 or SM Pneumatic System Energy Saving Program. Mounting aution. Accessories Refer to the operation manual (VBAT-M, M2, M3, M4) regarding combining booster regulators with older model air tanks. The accessories are secured by bands to the feet of the air tank. Once removed, make sure not to lose them. 2. Installation Install the tank away from people. It is dangerous if the accumulated air inside the tank were to seep out. Do not mount the air tank on a moving part or a place with vibration. When connecting a booster regulator with the tank, refer to the operation manual first, which is provided with the air tank before assembling. Refer to the operation manual regarding mounting methods when using long bolts. To mount the air tank on a floor surface, use the four holes to secure the tank with bolts or anchor bolts. Maintenance Warning. Inspection The use of pressure vessels could lead to an unexpected accident due to external damage or internal corrosion caused by drainage. Therefore, make sure to check periodically for external damage, or the extent of internal corrosion through the port hole. An ultrasonic thickness indicator may also be used to check for any reduction in material thickness. 2. Draining If this product is used with a large amount of drainage, the drainage could flow out, leading to equipment malfunction or corrosion inside the tank. Therefore, drain the system once a day.

Air Tank Series VBAT List of Air Tank for Overseas ountry/region Singapore, Malaysia Thailand, Taiwan Factory Act Law No applicable standard Exportable models Material: arbon steel Material: Stainless steel VBAT05A-SV-X02 VBAT0A-SV-X02 VBAT20A-RV-X02 VBAT38A-RV-X02 Standard product Details Product complies with ASME specifications JBA (Japan Boiler Association) certification attached Options/Accessories/Part No. <Standard Product> For VBATA (arbon Steel) Model VBAT05A- VBAT0A- VBAT20A- VBAT38A- Accessory kit Safety valve (When selecting an option) Note ) 2) Drain valve (When selecting an option) For VBATS (Stainless Steel) Model VBAT05S- VBAT0S- VBAT20S- VBAT38S- Accessory kit VBAT5S-Y-4 VBAT0S-Y-4 VBAT20A-Y-4 Drain valve (When selecting an option) VBAT-V <E ertified Product> Model VBAT05A-SV-Q VBAT0A-SV-Q VBAT20A-RV-Q VBAT38A-RV-Q Accessory kit Safety valve Drain valve VBAT5A-Y-3 VBAT0A-Y-3 VBAT-R (Set pressure: MPa), VBAT-S (Set pressure: 2 MPa) VBAT-V VBAT5A-Y-2 VBAT0A-Y-2 VBAT-S (Set pressure: 2 MPa) <Product Not Applicable to the ASME Standard> Model VBAT05A --X VBAT0A --X Accessory kit VBAT5A-Y-3 VBAT0A-Y-3 Safety valve (When selecting an option) VBAT-S (Set pressure: 2 MPa) Drain valve VBAT-V Note) : Nil when Rc thread is selected, N when NPT thread is selected. VBAT-V VBAT20A-Y-3 VBAT-R (Set pressure: MPa) Note ) The set pressure of the safety valve cannot be changed. Note 2) The safety valve is a safety measure that protects the tank from excess pressure. The valve opens automatically when the specified pressure is reached, releasing excess pressure inside the tank. The valve closes again when the pressure drops below a designated value. Select a pressure valve appropriate for the maximum operating pressure specification of the tank. VBAT20A-Y-2 VBAT-R (Set pressure: MPa) Safety valve Drain valve VBAT-V IN PORT /4 Safety valve VBAT-R, VBAT-S ø8.5 Drain valve 58 (LOSE) to 63 (OPEN) ø30 9 20 PORT /8 52 3/8 9 65 Made to Order For detailed dimensions, specifications and lead times, please contact SM. opper-free/fluorine-free Made to Order opper-free/ Fluorine-free Symbol 05 0 20 38 20 VBAT 0 A Tank internal capacity Internal capacity 5 L 0 L 20 L 38 L V With drain valve Material Symbol Material A arbon steel (SS400) S Stainless steel 304 Note ) The thread type for each port is Rc. Note 2) A stainless steel fitting and a drain valve are included in the same container as accessories. (For detailed dimensions, please contact SM.) A safety valve cannot be selected. Note 3) Since neither copper nor fluorine parts are used for the tank, a standard model can be used when options (safety valve and drain valve) are not necessary. 4

Series VBAT Dimensions: Standard Product (For Japanese Market) VBAT05A Material: arbon steel onnected to VBA0A, A Tank port Tank Spare port 63 257 (370) (307) ø56 EXH: 4 x ø 200 338 349 00 The length may be longer than the specification ifthe plugs mounted on the tank are not fit to the end. VBAT0A Material: arbon steel onnected to VBA0A, A Tank Spare port EXH: Tank port 70 278 (39) (8) ø80 4 x ø 32 4 47 20 80 The length may be longer than the specification ifthe plugs mounted on the tank are not fit to the end. onnected to VBA20A Tank Spare port onnected to VBA22A Tank port 70 278 (454) (367) ø80 EXH: 4 x ø (47) (367) ø80 EXH: 4 x ø 442 VBAT20A Tank port 305 80 32 4 47 Material: arbon steel onnected to VBA20A, 40A Tank Spare port (A) (B) ø206 20 80 EXH: 4 x ø3 20 80 The length may be longer than the specification ifthe plugs mounted on the tank are not fit to the end. onnected to VBA22A, 42A (A) (B) ø206 EXH: 4 x ø3 D 5 400 674 685 The length may be longer than the specification if the plugs mounted on the tank are not fit to the end. 00 200 00 200 (mm) model A B D Note) VBA20A 48 394 VBA40A 520 429.8 VBA22A 444 394 469 VBA42A 477 429.8 493 Note) When option G (pressure gauge) is selected

Air Tank Series VBAT Dimensions: Standard Product (For Japanese Market) VBAT38A 355 205 Material: arbon steel onnected to VBA20A, 40A Tank port Rc 3/4 0 824 835 Tank Spare port (A) (B) The length may be longer than the specification if the plugs mounted on the tank are not fit to the end. ø256 2 EXH: 4 x ø3 (A) (B) model VBA20A VBA40A VBA22A VBA42A onnected to VBA22A, 42A ø256 A 53 570 494 527 2 B 444 479.8 444 479.8 EXH: 4 x ø3 Note) When option G (pressure gauge) is selected D (mm) D Note) 59 543 VBAT05S Material: Stainless steel 304 onnected to VBA0A, A Tank port Tank 63 257 (370) (307) ø EXH: 4 x ø 200 300 00 VBAT0S Material: Stainless steel 304 onnected to VBA0A, A Tank EXH: Tank port 70 278 (39) (8) ø80 4 x ø 32 4 20 80 onnected to VBA20A Tank onnected to VBA22A Tank port 70 278 (454) (367) ø80 EXH: 4 x ø (47) (367) ø80 EXH: 4 x ø 442 32 20 80 20 80 6

Series VBAT Dimensions: Standard Product (For Japanese Market) VBAT20S Material: Stainless steel 304 onnected to VBA20A, 40A onnected to VBA22A, 42A, 43A Tank port Tank EXH: EXH: 305 80 (A) (B) ø206 4 x ø3 (A) (B) ø206 4 x ø3 D 400 674 00 200 model VBA20A VBA40A VBA22A VBA42A VBA43A 00 200 A 48 520 444 477 526 B 394 429.8 394 429.8 Note) When option G (pressure gauge) is selected (mm) D Note) 469 493 VBAT38S Material: Stainless steel 304 onnected to VBA20A, 40A onnected to VBA22A, 42A, 43A Tank EXH: EXH: Tank port Rc 3/4 (A) (B) (A) (B) D 355 205 ø256 4 x ø3 ø256 4 x ø3 0 824 2 model VBA20A VBA40A VBA22A VBA42A VBA43A 2 A 53 570 494 527 576 B 444 479.8 444 479.8 Note) When option G (pressure gauge) is selected (mm) D Note) 59 543 05 R VBAT A- S VBAT A- 0 With safety valve 20 R 38 S With safety valve Safety valve port A Tank model VBAT05 VBAT0 (mm) A 30 2 Safety valve port 7

Air Tank Series VBAT Dimensions: E ertified Product VBAT05A-Q Material: arbon steel onnected to VBA0A, A Safety valve port Tank Spare port 2 x EXH: Tank port 63 257 (370) (307) ø56 4 x ø 200 338 3 00 The length may be longer than the specification if the plugs mounted on the tank are not fit to the end. The length of G thread type is about 6 mm longer due to plug type differences. VBAT0A-Q onnected to VBA0A, A Material: arbon steel Safety valve port Tank Spare port 2 x EXH: Tank port 30 70 278 (39) (8) ø80 4 x ø 32 4 482 20 80 The length may be longer than the specification if the plugs mounted on the tank are not fit to the end. The length of G thread type is about 6 mm longer due to plug type differences. onnected to VBA20A onnected to VBA22A Safety valve port Tank Spare port 2 x EXH: EXH: Tank port 30 70 278 (454) (367) ø80 4 x ø (47) (367) ø80 4 x ø 442 32 4 482 20 80 20 80 When option G (pressure gauge) is selected The length may be longer than the specification if the plugs mounted on the tank are not fit to the end. The length of G thread type is about 6 mm longer due to plug type differences. 8

Series VBAT Dimensions: E ertified Product VBAT20A-Q Material: arbon steel onnected to VBA20A, 40A Tank Rc 3/4 Safety valve port onnected to VBA22A, 42A 305 80 Tank port 2 400 674 696 Spare port 2 x The length may be longer than the specification if the plugs mounted on the tank are not fit to the end. The length of G thread type is about 6 mm longer due to plug type differences. (A) (B) ø206 00 200 EXH: 4 x ø3 (A) (B) model VBA20A VBA40A VBA22A VBA42A ø206 A 48 520 444 477 00 200 B 394 429.8 394 429.8 EXH: Note) When option G (pressure gauge) is selected D 4 x ø3 (mm) D Note) 469 493 VBAT38A-Q onnected to VBA20A, 40A Material: arbon steel onnected to VBA22A, 42A Tank Rc 3/4 Safety valve port 2 Spare port 2 x (A) (B) EXH: (A) (B) EXH: D 355 205 Tank port Rc 3/4 0 824 846 The length may be longer than the specification if the plugs mounted on the tank are not fit to the end. The length of G thread type is about 6 mm longer due to plug type differences. ø256 2 4 x ø3 model VBA20A VBA40A VBA22A VBA42A ø256 A 53 570 494 527 2 B 444 479.8 444 479.8 Note) When option G (pressure gauge) is selected 4 x ø3 (mm) D Note) 59 543 9

Air Tank Series VBAT Dimensions: Product Not Applicable to the ASME Standard VBAT05A-X Material: arbon steel onnected to VBA0A, A Tank port Safety valve port Tank Spare port 63 257 (370) (307) ø56 EXH: 4 x ø 200 338 349 00 The length may be longer than the specification if the plugs mounted on the tank are not fit to the end. VBAT0A-X Material: arbon steel onnected to VBA0A, A Safety valve port 90 Tank Tank port 63 Spare port 25 (364) (30) ø56 EXH: 4 x ø 32 625 636 20 80 The length may be longer than the specification if the plugs mounted on the tank are not fit to the end. onnected to VBA20A onnected to VBA22A Safety valve port Tank Spare port Tank port 90 63 25 (427) (340) ø56 EXH: EXH: (390) (340) ø56 4 x ø 4 x ø 32 625 636 20 20 80 80 The length may be longer than the specification if the plugs mounted on the tank are not fit to the end. 20

Safety Instructions aution: Warning: Danger : aution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of aution, Warning or Danger. They are all important notes for safety and must be followed in addition to International Standards (ISO/IE) ), and other safety regulations. ) ISO 444: Pneumatic fluid power General rules relating to systems. ISO 443: Hydraulic fluid power General rules relating to systems. IE 204-: Safety of machinery Electrical equipment of machines. (Part : General requirements) ISO 028-: Manipulating industrial robots - Safety. etc. Warning. The compatibility of the product is the responsibility of the person who designs the equipment or decides its specifications. Since the product specified here is used under various operating conditions, its compatibility with specific equipment must be decided by the person who designs the equipment or decides its specifications based on necessary analysis and test results. The expected performance and safety assurance of the equipment will be the responsibility of the person who has determined its compatibility with the product. This person should also continuously review all specifications of the product referring to its latest catalog information, with a view to giving due consideration to any possibility of equipment failure when configuring the equipment. 2. Only personnel with appropriate training should operate machinery and equipment. The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced. 3. Do not service or attempt to remove product and machinery/equipment until safety is confirmed.. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed. 2. When the product is to be removed, confirm that the safety measures as mentioned above are implemented and the power from any appropriate source is cut, and read and understand the specific product precautions of all relevant products carefully. 3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction. 4. ontact SM beforehand and take special consideration of safety measures if the product is to be used in any of the following conditions.. onditions and environments outside of the given specifications, or use outdoors or in a place exposed to direct sunlight. 2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or other applications unsuitable for the standard specifications described in the product catalog. 3. An application which could have negative effects on people, property, or animals requiring special safety analysis. 4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation. ompliance Requirements aution. The product is provided for use in manufacturing industries. The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SM beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch. Limited warranty and Disclaimer/ ompliance Requirements The product used is subject to the following Limited warranty and Disclaimer and ompliance Requirements. Read and accept them before using the product. Limited warranty and Disclaimer. The warranty period of the product is year in service or.5 years after the product is delivered. 2) Also, the product may have specified durability, running distance or replacement parts. Please consult your nearest sales branch. 2. For any failure or damage reported within the warranty period which is clearly our responsibility, a replacement product or necessary parts will be provided. This limited warranty applies only to our product independently, and not to any other damage incurred due to the failure of the product. 3. Prior to using SM products, please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products. 2) Vacuum pads are excluded from this year warranty. A vacuum pad is a consumable part, so it is warranted for a year after it is delivered. Also, even within the warranty period, the wear of a product due to the use of the vacuum pad or failure due to the deterioration of rubber material are not covered by the limited warranty.. The use of SM products with production equipment for the manufacture of weapons of mass destruction (WMD) or any other weapon is strictly prohibited. 2. The exports of SM products or technology from one country to another are governed by the relevant security laws and regulations of the countries involved in the transaction. Prior to the shipment of a SM product to another country, assure that all local rules governing that export are known and followed. Revision history Edition B Edition Addition of booster regulators/air-operated type, VBA22A/42A Addition of booster regulator with max. operating pressure of.6 MPa, VBA43A Number of pages increased from 24 to 28 Addition of booster regulator, VBA0A Deletion of booster regulator, VBA0 hange of accessories/part no. of air tank, VBAT series hange of dimensions of air tank, VBAT series Number of pages decreased from 28 to 20 MY NY Edition D Addition of booster regulator, VBAA Deletion of booster regulator, VBA Addition of air tanks, E certified Addition of air tanks, not applicable to the ASME standard Addition of an elbow silencer to options Number of pages increased from 20 to 24 OW Safety Instructions Be sure to read Handling Precautions for SM Products (M-E03-3) before using. Akihabara UDX 5F, 4-4-, Sotokanda, hiyoda-ku, Tokyo 0-002, JAPAN Phone: 03-5207-8249 Fax: 03-5298-5362 URL http://www.smcworld.com 200 SM orporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. D-DN st printing MP printing OW 7SZ Printed in Japan.