Bonding Reliability Testing for Wafer Level Packaged MEMS Devices

Similar documents
Inadequacy of traditional test methods for detection of non-hermetic energetic components

A Practical Guide to TM 1014 (Seal)

DEFENSE LOGISTICS AGENCY LAND AND MARITIME P.O. BOX 3990 COLUMBUS, OHIO

MIL-STD-883K w/change 2 METHOD SEAL

Implication of Multiple Leak Tests and Impact of Rest Time on Avionic Hybrids

Eliminating Gross Leakers by Seal Processing for Lowest Leak Rates per MIL-STD-883 TM 1014 Seal

Advantages of Carrier Gas Leak Detection using Novel Helium or Hydrogen Leak Detectors with Specific Sensor Types

Commercial Practice Test Method Internal Vapor Analysis of Hermetic Devices

Chapter 6 Leak detection

Gas and Moisture Transport through Non-Hermetic Glass-to-Metal Bridge- Wire Initiator Seals

The Helium Leak Detector

The latest automotive systems require innovative leak test methods and fixturing.

Variable Leak Rate Phenomena in Glass to Metal Seals

MIL-STD-202G METHOD 112E SEAL

Seal Processing for Lowest Leak Rates and the New MIL-STD-883 TM 1014 Seal

DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD 112, SEAL

Canadian Light Source Inc. Vacuum Component Leak Test Technical Procedure

BEST KNOWN METHODS. Transpector XPR3 Gas Analysis System. 1 of 6 DESCRIPTION XPR3 APPLICATIONS PHYSICAL INSTALLATION

Hermetic Cover Seal Process Technology MIL-STD-883 TM 1014 Seal

Supporting Information for Micro-Collection of. Gases in a Capillary Tube: Preservation of Spatial

CO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype

VIC offers a variety of Calibrated Gas Leaks

Are Detonator Qualification and Lot Acceptance Test Requirements Rational?

This educational seminar discusses creating, measuring, and troubleshooting Rough Vacuum.

Measuring mass flows in hermetically sealed MEMs & MOEMs to ensure device reliability

Instrumentation & Data Acquisition Systems

Revision 2013 Vacuum Technology 1-3 day Good Vacuum Practice 1 Day Course Outline

Vacuum. Dry Turbo Pumping Stations. Roughing Pumps for 1 K Helium Pots and Lambda Refrigerators. Hermetically Sealed Pumps for He3 Recirculation

Background Statement for SEMI Yellow Ballot 4446 NEW STANDARD: GUIDE TO EVALUATING HERMETICITY OF MEMS PACKAGES

Report on OSU Opto-Pack Prototypes

~ goss7-- OSTI RECEIVED LEAKAGE TESTING OF PACKAGINGS WITH THREE-O-RING CLOSURE SEALS. c=t) SUMMARY INTRODUCTION

Succeeding with Production Air Leak Testing Methods. Paul Chamberlain President, CEO

Leak Checking Large Vacuum Chambers

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

Glass Frit Wafer Bonding Sealed Cavity Pressure in Relation to Bonding Process Parameters. Roy Knechtel, Sophia Dempwolf, Holger Klingner

HOW WISE TECHNOLOGY WORKS INFICON Protec P3000 sensor powered by Wise Technology, consists of an evacuated gas cell covered by a quartz membrane.

SAES Packaging service. making innovation happen, together

Current Trends in Leak Testing Technology. A. P. Fonseca, H. P. Marques, A. M. C. Moutinho and O. M. N. D. Teodoro

Innovative gas and outgassing analysis and monitoring

Vibration isolated tables. Individually tailored to your requirements.

Pressure Measurement

A Reliable and Tracer Gas Independent Leak Detector for Food Packages

A Journal of Practical and Useful Vacuum Technology. By Phil Danielson

Applications of a Magnetic Sector Process Mass Spectrometer to the Analysis of Variable Vacuum Samples

Best Practices for Ultrasonic Compressed Air Leak Detection

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

Major Design Features

EVOLUTION OF RUPTURE DISC MANUFACTURING TECHNOLOGY AND PERFORMANCE

Protec P3000 (XL) Helium Sniffer Leak Detector

Chamber Test Testing Theory

Regulatory Concerns for Leakage Testing of Packagings with Three 0-Ring Closure Seals

Development of Helium Leak Testing System and Procedure for testing Welds of Steam Generator

3200 Dwight Road Suite #100 Elk Grove, CA Ph: Fax: GNB Corporation

International Journal of Modern Trends in Engineering and Research e-issn No.: , Date: April, 2016

Leak, Flow and Package Testing 101

USA (Bartlett, IL) Division

GPP model GPPT model GPC model CLP model

LOW OUTGASSING ACCELEROMETERS AND CABLES FOR THERMAL VACUUM AND VIBRATION TEST ENVIRONMENTS

OPERATION MANUAL NTF-15

Helium Mass Spectrometric Leak Detection In Large Size Process Plants

Introduction of Vacuum Science & Technology. Diffusion pumps used on the Calutron mass spectrometers during the Manhattan Project.

h2000 plus HyDROGEN LEAk DETECTOR

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

D R A F T. Operating Procedures for the NPDGamma Liquid Hydrogen Target at the BL 13. Version 1.00

OPERATION MANUAL NTF-60 Plus

OBJECTIVE 6: FIELD RADIOLOGICAL MONITORING - AMBIENT RADIATION MONITORING

Standard Operating Manual

The Unsettled World of Leak Rate Physics: 1 Atm Large - Volume Considerations Do Not Apply to MEMS Packages, A Practitioner's Perspective

Safety devices for overpressure protection. Rupture discs: applications, sizing, and types

Basic & Controlled Atmosphere Glove Boxes

CHEMICAL ENGINEERING SENIOR LABORATORY CHEG Initiated Chemical Vapor Deposition

easycomposites SETUP & DAILY USE INSTRUCTIONS NEVER SWITCH OFF YOUR PUMP WITHOUT FIRST CLOSING THE VALVE TO THE CHAMBER

Chapter 8: Cryo-sorption pumps

user leaflet GAUGING TRANSDUCERS

Chemistry Chapter 11 Test Review

OMNISTAR / THERMOSTAR. The efficient solution for gas analysis. Intelligent software. Wide range of applications.

DESIGN VERIFICATION AND QUALIFICATION OF NEW POPPET AND BUSHING ON GMA FLIGHT SOLENOID VALVES

Understanding How the Appearance of Optical Fiber Splices Relates to Splice Quality

Level MEASUREMENT 1/2016

A NOVEL SENSOR USING REMOTE PLASMA EMISSION SPECTROSCOPY FOR MONITORING AND CONTROL OF VACUUM WEB COATING PROCESSES

Helium Leak Detection by Detector Probe Technique : Is it a Leak Detection or Concentration Detection Method?

Int r oduct ion t o Int egr it y Tes t ing Theor y

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS General Certificate of Education Ordinary Level

Thin Film Slot Coating in a Rarefied Low Viscosity Gas

Vacuum Science Techniques and Applications Dan Dessau Adv. Lab 2007

DRAFT. Operating Procedures for the NPDGamma Liquid Hydrogen Target in TA-53, Building MPF-35

ONEIDA RESEARCH SERVICES, Inc.

The Principles of Vacuum Technology

Applied Compression s nitrogen generator packages offer users a cost-effective alternative to costly bottled nitrogen.

Paper Session II-C - Verification of International Space Station Component Leak Rates by Helium Accumulation Method

Oxygen Contamination

9 rue Alfred Kastler - BP Nantes Cedex 3 - France Phone : +33 (0) website :

Specification for the Vacuum Chamber of the Liquid Hydrogen Target for the NPDGamma Experiment

HiQ laboratory gas generators.

Leak Detection. Kirsten Zapfe, DESY CAS Vacuum in Accelerators Platja D Aro, May 21, Special thanks to S. Holm, N. Mildner and A.

R I T. Title: STS ASE Semiconductor & Microsystems Fabrication Laboratory Revision: Original Rev Date: 01/21/ SCOPE 2 REFERENCE DOCUMENTS

Oxygen & Binary Gas Measurement and Analysis

Pressure Measurement. Introduction. Engr325 Instrumentation. Dr Curtis Nelson 3/12/18

Design. Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing. Working Principle

Instrumentation & Data Acquisition Systems

Transcription:

Bonding Reliability Testing for Wafer Level Packaged MEMS Devices Michael Shillinger Vice President of Operations Innovative Micro Technology Santa Barbara, CA, USA mjs@imtmems.com October 20, 2011

Innovative Micro Technology Established in 2000, IMT is a privatelyheld, profitable company Acknowledged leader in complex MEMS foundry/contract manufacturing Offering flexible turn-key services: Cooperative design for manufacturability Process development Prototyping Volume manufacturing Testing Metrology/analytical services IMT s Mission: To enable the shortest time to market and greatest overall value while leading our customers into volume production 2

MEMS perform best as fabricated in the clean room Airborne contamination generally causes device failure Lead to development of wafer level packaging (WLP) WLP forced the need for bond quality testing Hermeticity testing Fine and gross leak verification Gross leaks > 1 x 10-5 > Fine Leaks 3

Gross Leak Testing Set up (Mil-Std-883G Method 1014) Preconditioning Chamber 1 Test Chamber With FC-40 V V V 1,2,3 VP N2 P 2,3 5,6 FC-84 Fluid 4 1) Parts are placed in the preconditioning chamber 2) A vacuum is pulled on the chamber to 5.0 in Hg 3) The Vacuum is maintained for the prescribed time 4) Fluorocarbon FC-84 is pumped into the chamber covering the parts 5) Chamber pressurized to 90 PSIA with N2 6) Pressure is maintained for the prescribed time 7) Pressure vented, fluid drained 1) Parts are placed into the test chamber 2) Temperature is elevated to 125 C 3) Operator views the parts through an illuminated port for 60 sec looking for bubbles 4

Gross Leak Testing Set up (Mil-Std-883G Method 1014) Pros: Historical Military Specification procedure with abundant data Commercial equipment exists for performing this test Cons: Not enough resolution for the small cavity volume of MEMS devices Can be destructive for certain types of MEMS devices Not wafer level 5

Fine Leak Testing Set Up (Mil-Std-883G Method 1014) Vacuum Pump Vent to ATM v Steps: 2 & 4 Helium leak detector Step: 6 Steps:1 & 5 v Vacuum Chamber Device v v Step 1: Evacuate chamber Step 2: Vent Chamber to atmosphere Step 3: Pressurize chamber with helium Step 4: Vent chamber to atmosphere Step 5: Evacuate chamber Compressor Step: 3 Helium Source Step 6: Residual gas analysis to detect helium 6

Fine Leak Testing Set Up (Mil-Std-883G Method 1014) Pros: Historical Military Specification procedure with abundant data Commercial equipment exists for performing this test Cons: Not enough resolution for the small cavity volume of MEMS devices Can be destructive for certain types of MEMS devices Not wafer level 7

Not adequate for MEMS with small device cavities Insufficient resolution New testing techniques have been developed specifically for MEMS devices Applicable for other device technologies also 8

Six new testing techniques with more than adequate resolution for MEMS Name of Technique Basic Principles Pros Cons Wafer or Die Level Fine or Gross Leak Membrane deflection Measurement of membrane deflection to determine hermeticity Quick, economical, and precise Requires capital equipment (Wyko Interferometer) Wafer level Both Radio isotope Measurement of radio active particles within a cavity Very precise Licensing required, requires handling of radioactive material Die level Both Cumulative Helium Leak Detection (CHLD) Detection of helium, in a cumulative fashion, using a mass spectrometer Sensitive, Mil Spec approved Requires capital equipment (Inficon s Pernkica 700 Series System) Die level Both 9

Six new testing techniques with more than adequate resolution for MEMS Name of Technique Basic Principles Pros Cons Wafer or Die Level Fine or Gross Leak Change in resistance measurement Resistance measurement of an in package thermistors Allows for 100% testing Requires in package thermistors, requires electrical auto probe system Wafer level Both Q measurement Looking at the quality factor of a resonant structure as it it affected by gas damping Quick, economical, and precise Only works for devices that resonate (i.e. accelerometer) Wafer level Both Pressurized steam Inspection of a delidded device looking for in package moisture Definitive Destructive, requires autoclave Die level N/A 10

Membrane Deflection Testing Membrane is formed during fabrication of lid or capping wafers that is ~30 microns in thickness Membrane deflection for packages in vacuum or pressurized is optically measured with an interferometer Concave membranes = vacuum Convex membranes = pressure Angstrom resolution Automated wafer level non destructive test In use at IMT for production screening Wyko interferometer image of a deflected lid membrane indicating hermeticity 11

Membrane Deflection Testing Measures both gross and fine leaks NorCom Systems Optical hermeticity tester Interferometer with an integrated holographic camera Enables recorded images to be superimposed on to live images for comparison LT-550 optical leak test system Courtesy of NorCom Systems 12

Membrane Deflection Testing Pros: Precise Fast Low cost Wafer level Non destructive Automated Will measure vacuum and pressure Cons: Requires capital equipment Wyko interferometer or LT-550 optical leak test system manufactured by NorCom Systems Device must have a cavity in the lid ~30 microns in thickness and it needs to be opaque 13

Radioisotope Testing Measures both gross and fine leaks Similar to helium leak testing Packages are subject to pressurized radioactive gas Measures alpha radiation from krypton 85 N2 gas Uses a scintillator Presence of gamma radiation indicates non-hermetic packaging Die level testing higher cost Atomic energy license required 14

Radioisotope Testing Pros: Extremely precise Delectability10 11 KR-85 molecules Cons: Requires handling radioactive material Requires an Atomic Energy license Expensive test set up 15

Cumulative Helium Leak Detection (CHLD) Only hermetic device testing method currently approved by the military (Mil-Std-750 Method 1071) with sufficient resolution for MEMS Die level, sufficient for both gross and fine leak testing Can detect leaks < 1x10-14 ATM-cc/sec Detects krypton, fluorocarbons, argon, and helium Inficon s Pernkica 700 Series System 16

Cumulative Helium Leak Detection (CHLD) Pros: Sensitive Meets military specification Mil-STD-750 Method 1071 Cons: Die level Requires purchase of capital equipment Inficon s Pernkica 700 Series System 17

Resistance-Hot vs. Resistance-Cold (R-Hot vs. R-Cold) Comparison of resistance of MEMS device or an on board thermistor to baseline resistance Screening for low resistance indicates that high vacuum is not present Automated probe station 18

Resistance-Hot vs. Resistance-Cold (R-Hot vs. R-Cold) 100% and performed at wafer level Wafer maps generated to indicate pass-fail Ideal for production 19

Resistance-Hot vs. Resistance-Cold (R-Hot vs. R-Cold) Pros: Allows for 100% testing Automated Wafer level Cons: Requires in package thermistors Requires electrical probe system 20

Q Measurement of MEMS Resonators Quality (Q) factor Low pressure = low viscous drag on resonating structure High Q factor Wafer level test (laser doppler vibrometry or integrated piezo-resistive device) Vibration induced electrostatically Good for both gross and fine leak testing 21

Q Measurement of MEMS Resonators Pros: Quick Economical Precise Wafer level Cons: Devices applicability Accelerometer Microbolometer 22

Pressurized Steam Testing Devices placed in autoclave chamber Chamber filled with high temperature pressurized steam 130 C at 2.7 ATM and 100% RH for a prescribed time Pressurized steam will penetrate into device cavity if the bond is not hermetic Devices are de-lidded and optically inspected for moisture Destructive Test would be performed in development only 23

Pressurized Steam Testing Pros: Conclusive Equipment is commonly available Cons: Destructive Die level Not a production test Not economical 24

Summary Fine and gross leak testing has been around for many years Due to small cavity size of MEMS devices current tests do not exhibit sufficient resolution Battery of 2 nd generation tests have been developed which work with MEMS and other devices Membrane deflection R-hot vs. R-cold CHLD Q measurement testing Pressurized steam IMT currently uses both membrane lid deflection and thermistor measurement screening (R-Hot vs. R-Cold) in production testing of MEMS devices 25

Thank you for your attention. Questions?? 26