Specifications. JIS Symbol 2 port valve 3 port valve (A) 2 (A) 2. Construction. 2 port valve/series VHK2 3 port valve/series VHK3.

Similar documents
Specifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Standard style

Specifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Flame resistant style

Clean Speed Controller with One-touch Fitting

Pilot Check Valve: Metal Body Type

Series AS-FPQ/AS-FPG. Speed Controller with One-touch Fitting for Clean Room. Speed controllers for clean room use

Air Saving Valve reduction in 40% air consumption 40% air consumption Air consumption reduction ratio (%) Flow valve Flow valv

Air Saving Valve. Pressure Valve Flow Valve

Air Saving Valve. Series ASQ. Series ASR. Pressure Valve. Flow valve TMH ASD AS AS-FG AS-FP AS-FM ASP ASN AQ ASV AK VCHC ASS. r r AS-FE KE 10 0.

Hand Valve Series. Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Control Open/Close for Air Supply.

How to Order. Finger material. Carbon steel 1 Stainless steel. Dust cover material Chloroprene rubber (CR) Fluoro rubber (FKM) Silicon rubber (Si)

Coiling Tube with Twist-Proof Fitting

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

Compact Manometer. Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Compact Manometer. Pressure measurements can easily be taken any time, anywhere.

Vacuum Regulator. IRV10/20 Series. Weight reduced by. RoHS ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV

VACUUM REGULATORS CONTENTS

Change Valve. Push-In Fitting Type Three-way Changeover Valve. Changeover Air Direction by 90. Lightweight and Compact Design.

Cautions : 1. Be careful when you release the Stop Fitting with some internal pressure

AS13 1F-M3 AS13 1F-M5 AS23 1F-01 AS23 1F-02

Push-In Fitting Type with Stop Valve

ALF400 to 900, ALT-5/-9

One-touch Fittings Manifold. Porting. One-touch fitting. One-touch fitting. One-touch fitting. One-touch fitting. One-touch fitting.

Push-In Fitting Type Silencer

Direct Operated Precision Regulator Modular Style. Standard Specifications

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

(1) Type (2) Thread size (T) (3) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R)

Ball Valve Series. Push-In Fitting Type Shut-off Valve. Control Open/Close Air Supply. Ensure Effective Area for Variety of Tube Dia.

Push-In Fitting Type Pressure Gauge

Standard Specifications

Smooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV

How to Order. Applicable tube O.D. Thread. 8 ø8. ø10. ø12. ø16. Tube (Rod) Straight union. T Different dia. straight. F Female connector TX Male elbow

Connection Thread M, R(PT), Rc(PT) How to Order. Applicable tube O.D. Thread. 8 ø8. ø10. ø12. ø16. Tube (Rod)

Series 10-IRV10/20. Vacuum Regulator C08 IRV C08 IRV 20 A. How to Order. Standard connections. Single sided connections. Accessory w Nil G ZN ZP ZA ZB

Digital Flow Switch. Series PFM7

Related Products: Auto Drain Valve. Model/Specifications. Model

Speed Controller Anti-spatter Series

Tube Cutter with Measuring tape built-in

Anti-spatter Tube. Spatter-Proof Tube for Pneumatic Piping. Polyamide type Tube Coated with Flame-Retardant Resin(Equivalent to V-0 )

STC. Push-In Fittings & Polyurethane Tubing. Fine Quality. Precision Engineered Advanced Design. Excellent Prices

Compact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ

Smooth Vent Valve XVD. Series

Recommended applicable tubing. Specifications. Operating vacuum pressure. 20 C to 80 C Threads. Principal parts material

Coiling Tube Series. Coiling Tube for General Pneumatic Piping. Coiling Tube for General Pneumatic Piping. Suitable for Air Gun or Air Driver.

Pressure Gauge Series

Tube for General Pneumatic Piping

(1) Name of tube (2) Tube dia. (O.D./I.D.) (3) Tube length. (4) Tube color. Model UD0425. UD1290 O.D. I.D. (mm) UD1075 UD0860 UD

Brass One-touch Fittings

Smooth Vent Valve. XVD Series

Static dissipative Resin (Surface Resistivity : 10 4 ~10 7 Ω).

reduces flow setting time and setting errors!

(1) Type (2) Cylinder dia. (3) Gripper action : Single-acting closing gripper (normally open) (4) Holder type

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6

Cautions : 1. Clogging of the element raises resistance to exhaust, thus lowering the

Power Valve: Precision Regulator. High precision, large capacity relief regulator

(1) Type. (2) Tube dia. (ød) : ø8mm (ø5/16in.) (3) Thread size (T) (4) Specification. Fluid medium. Air, water * 1, * 2, * 3 Max. operating pressure

Multi Core Tube for General Pneumatic Piping

Series ZFC. Air Suction Filter In-line Type with One-touch Fittings

Series variation. Silencer. High damping effect and 2 types of materials. Applicable cylinder bore size (mm) Effective sectional area (mm 2 )

Standard Specifications. Fluid Proof pressure Maximum operating pressure. Regulating pressure range

Polyurethane Tube. Straight Tube for General Pneumatic Piping. Excellent in Flexibility. Suitable for Compact Piping Requiring Small Bending Radius

4-63 T UBE FITTINGS TUBING P OLYURETHANE TUBING SERIES TU P RODUCTS FOR A LIST OF STOCKED PRODUCTS, PLEASE SEE THE CURRENT SMC PRICE LIST S TOCKED

Series KJ. Miniature One-touch Fittings. Applicable Tube

Vacuum Saving Valve Series ZP2V How to Order ZP2V A5 03 Connection thread symbol for the pad Male thread connection Symbol Thread Applicable fixed ori

(1) Type (2) Tube dia. (ød(1)) (3) Thread size (T) (4) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R)

// ADapters GUIDelines

Insert Ring. Protection Ring from Tube Deformation. Protect tubes from deformation. Ultra soft tube is connectable to Fitting.

Cautions : 1. The gauge orientation on the GPU and GPM types can be changed by using

PVC Quick Drain Valve

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Tube for Clean Environment Polyurethane Tube Clean-Room Package

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

Series AMJ. Drain Separator for Vacuum

Ejector for Conveying particles, powder and fibers Vacuum GeneratorVRL

SeriesTRBU. Flame Resistant (Equivalent to UL-94 Standard V-0) FR Double Layer Polyurethane Tubing

Flow control valves Series RFU - RFO 2/

ALF400 to 900, ALT-5/-9

F l o w c o n T R o l v a l v E S

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New

Regulator. Accessory. Description. Symbol. Nil. With bracket. B With round. Port size. (Without limit indicator) With set nut (For panel mount)

(2) Effective sectional area (no code for mini type) (3) Intake-side shape (no code for mini type) : Quick-fitting joint type : Taper pipe thread type

RP series Rotor Pumps

The plastic bowl guard does not corrode. The draining method is selectable between the push type and the auto drain type.

Speed Controller Constant Flow

RD(H)20/25 Pressure-Reducing Regulator User Manual

Model SPCøD-T SPC4-M5 SPC4-M50 * 1 SPC4-M6 SPC4-02 SPC6-M5 SPC6-M6 SPC6-01 SPC6-02 SPC16-03

Die Temperature Control Fitting Series

SEALED CONNECTORS FOR THE LIMIT SWITCHES

Model AWG20 AWG30 AWG40 AWG20K AWG30K AWG40K

How to Order RM0 0 Z. IN/OUT fitting type Metric size Inch size Straight Elbow Straight Elbow Straight Elbow Straight Elbow ø ø ø ø ø ø ø ø ø/ ø/ ø/ ø

Pneumatic valve islands

(1) Union Filter for positive and negative pressure (2) Filter size. (3) Tube dia. (4) Holder option : without Holder : with Holder

Pure-Flo Handwheel Operated Valves (903, 913, 963) Instruction Manual

Pressure-Relief Cartridge Valve, Size 4

Low torque Metal seal type Rotary joint

Hand lever valves VHER

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

PN LINE. Technical remarks PN 11 PN 13 PN 14 PN 15 PN 17 PN 18 PN 20 PN 23 PN 25 PN 26 PN 27 PN 28 PN 29 PN 37 PN 38 PN 39 PN 40 PN 43 PN 10 8_9 10_12

Suitable for Semi-Conductor, Measuring Instrument, Printing and Medical Industries

Transcription:

Finger Valve eriesvhk Large effective area:.0 to 7.5 mm mall knob operating force: 0. to. kgfcm Poppet valve construction with few seal defects The series begins with the min. tube O.D. of. election from four types in accordance with the piping specifications The knob in the HUT position of port valves discharges residual pressure from side A. (There is no exhaust port.) pecifications Valve / port valves Fluid Air Proof pressure Max. operating pressure.5mpa.0mpa Operating vacume pressure 00kPa Ambient and fluid temperature 0 to 0 C Applicable tube material () Nylon, oft nylon, Polyurethane Accessory (Option) Note ) Be careful of maximum operating pressure when soft nylon or polyurethane tube is used. Use VHK ( port valve) for vacuum application. VHK is not suitable for vacuum. JI ymbol port valve port valve (A) (A) Construction (P) (P)(R) port valve/eries VHK port valve/eries VHK The valve direction clearly indicates whether the valve is open or closed. (HUT-OPEN: Counterclockwise) HUT 90 OPEN Classification of knob by colour difference facilitates distinction between port valves and port valves Component Parts Body Knob Cover Cam ring tem pring guide pring Packing, O ring, Valve tandard style Flame resistant style tandard style Flame resistant style Flame resistant (UL tandard V-0)CR For flame resistant cover equipped style only POM POM C0B Electroless nickel plated U0 NBR PBT Flame resistant PBT (UL tandard V-0) PBT Flame resistant PBT (UL tandard V-0)

How to Order tandard Flame resistant VHK 0 0 R L VHK R 0F 0F R L C Valve model port valve port valve Flame resistant 0F 0F 0F 0F F 0 0 0 0 P port size ø ø0 ø R(PT) R(PT) R(PT) R(PT) A port size 0F 0F ø 0F 0F ø0 F ø 0 R(PT) 0 R(PT) 0 R(PT) 0 R(PT) L None With L bracket and screws are attached. Knob colour (tandard) Flame resistant cover Without cover With cover (For C One-touch fitting style only) port valve port valve R port valve (Option) port valve Grey Blue Red tandard (P): One-touch/(A): One-touch (P): Male thread/(a): One-touch (A) Applicable tube O.D. (mm) (A) Applicable tube O.D. (mm) (P) ø ø0 ø (P) ø ø0 ø ø ø0 ø (P): One-touch/(A): Male thread (P): Male thread/(a): Male thread (A) (P) ø ø0 ø (A) (P) Flame resistant style (UL-9 tandard V-0 equivalent) (P): One-touch/(A): One-touch (A) Applicable tube O.D. (mm) (P) ø ø0 ø ø ø0 ø (P): Male thread/(a): Male thread (A) (P)

(P)/(A): One-touch fitting Tube O.D. (mm) 0 0 0 H L L L L L5 L M M Q (mm ) Weight (P)Æ(A) (A)Æ(R) ass'y No. C D E F G J K VHK -0F-0F 7....5.5 5. 5... 5 VHK -0F-0F...7.5.5. 5. 5. 5. VHK -0F-0F.. 7. VHK -0F-0F 50.5 5....5.5.7. 9. VHK -0F-0F..7 7 VHK -0F-0F 5.5 0.5.7.7.5 0.. VHK -0F-0F 0.5 0.. 9 VHK -F-0F.5 0.5.5. 0. 7. VHK -F-F.5. 7.5 (P): Male thread, (A): One-touch fitting port valve Tube O.D. (mm) (mm H L L L L L5 L M Q ) Weight B (P)Æ(A) thread R(PT) (A)Æ(R) C D E F G J K flats) ass'y No. VHK --0F 5.9. 9. 5. 9 9.5.5.0. VHK --0F 5.9. 9.. 50 VHK -0-0F 55... 5.. 5 VHK -0-0F 5.9...5.5. 7.. 5 VHK -0-0F...7 5 7 VHK -0-0F 0.....5.5 5.. 9.7 7.. 5 VHK-BA.5.5 7.5 VHK -0-0F 59 7 0 VHK -0-0F 7. 0.5. 0..5 7..5.... 9 9 VHK-BA 9 7 0 5.5 VHK -0-F 7.5 70 VHK -0-0F.....5.5.. 0.7 7.. 5 7 VHK-BA.5.5 7.5 VHK -0-0F 0 0 0 VHK -0-0F 7. 0.5. 0..5 77..5 5.... 5 9 VHK-BA 9 7 0 5.5 VHK -0-F 7.5 7 0 VHK -0-0F 7. 0.5 7.7 0..5 0..5.7... 7 70 VHK -0-F 7.5 70 7 port valve Reference dimensions after insertion of R(PT) threads.

(P): One-touch fitting, (A): Male thread Tube O.D. (mm) thread R(PT) (mm H L L L L L5 L M Q ) Weight B (P)Æ(A) (A)Æ(R) C D E F G J K flats) ass'y No. VHK -0F- 5.9 9..0 9 9..5.5 5.. VHK -0F-0 55... 5 VHK -0F- 5.9 9..0 50 VHK -0F-0 5.9. 5..5.5.. VHK -0F-0 0.. 7. 5 7 VHK -0F-0.. 5 VHK -0F-0. 5 7 VHK -0F-0 5.. 9.5.5.7. 59 9 VHK -0F-0. 0 0 0 VHK -0F-0 7.. 9 7 0 VHK -0F-0 7. 0.5..5 0... 5 VHK -0F-0 7. 7.7 7 70 9 VHK -F-0 7.. 70 VHK -F-0 77..5 5..5. 7.5. 7 VHK -F-0 0..7 70 7 port valve Reference dimensions after insertion of R(PT) threads. (P)/(A): Male thread thread R(PT) H L L VHK -- 5. 9.9..5.5.0 VHK -0-. 9.0..5.5 VHK -0-0 5... VHK -0-0 7.. 9.0 9.5.5 VHK -0-0 7 9 VHK -0-0 5.0...5.7 VHK -0-0... VHK -0-0 9..7.5 5. VHK -0-0 97..7 7.5 L L L5 L Q (mm ) (P)Æ(A) (A)Æ(R)..... Weight 0 B 5 5 57 7 7 79 across flats) T flats) ass'y No. C D E F G J K 9 7 7 7 5 7 9 7 9 90 9 0 port valve Reference dimensions after insertion of R(PT) threads.

Warning Precautions Design q Contact MC if using fluids other than air. w Do not supply air pressure from (A) port. The air will leak to (P) port. e ince the valve may have slight air leakage, it may not be suitable for holding pressure in a pressure vessel. election Operation method: To stop the knob in a midway position can cause malfunction. witch it to ON or OFF quickly and firmly. Mounting L type bracket mounting: Tightening torque of 0.5 to 0. N should be applied to the bolts when mounting the bracket to the body. Piping Precautions for handling the male threads of the R (PT) pipe fitting with a seal; q Use a wrench to secure the hexagon portion to screw in the fitting. If the size of the wrench is not appropriate it will be stripped. w To screw in the fitting, first hand-tighten; then, use a tool to rotate it to turns. If it is tightened excessively, the amount of sealing agent that protrudes will increase, so make sure to remove the sealing agent that has protruded. e Re-use of fittings: () Ordinarily, the fitting can be reused to times. () Using an air blower, remove the sealing agent that is peeling from the removed pipe fitting before reusing the fitting. If the peeled sealing agent enters the peripheral equipment, it could cause air leakage. () If the sealing effect has been lost, place a seal tape over the sealing agent to reuse the fitting. Do not use any other agent except a seal tape. One-touch fitting () When tubes other than MC s are used, verify that the tube O.D. satisfies the following accuracy; Nylon tube Within ±0.mm oft nylon tube Within ±0.mm Polyurethane tube Within +0.mm, 0.mm If the tube s external accuracy is not satisfied, it might not be possible to connect the tube or after it is connected, it could lead to air leakage or cause the tube to pull out. Flame resistant style (P)/(A): One-touch fitting Tube O.D (mm) H L L L L L5 L L7 Q M M (mm ) (P) (A) (A) (R) VHK R-0F-0F 7....5.5 5. 5. 5... VHK R-0F-0F....5.5 5... 7.. VHK R-0F-0F 5....5.5 5..7.7. 0 0 VHK R-0F-0F 0.5 0.5.5 5 0. 0... VHK R-F-F.5.5.5 7.. 7.5. Tube O.D Weight (mm) VHK R-0F-0F 5 VHK R-0F-0F VHK R-0F-0F 7 0 0 VHK R-0F-0F 9 VHK R-F-F s ass y No. C D E F G J K. ø. ø9. ø. ø5.7 Flame resistant style (P)/(A): Male thread Reference dimensions after insertion of R(PT) thread thread H L L L L L5 L Q B (mm ) Weight R(PT) (P) (A) (A) (R) VHK R-0-0 5....5.5 57.. 0 VHK R-0-0 7 9 9.5.5. 7 VHK R-0-0....5 7.. 7 VHK R-0-0 97..7.7.5 7.5. 0 thread R(PT) VHK R-0-0 VHK R-0-0 7 VHK R-0-0 9 VHK R-0-0 T across across flats) flats) 7 9 ass y No. s C D E F G J K 5