FEATURES mbar to 0 bar, to 50 absolute, gage or differential pressure Increased media compatibility Wide operating temperature range SIL and DIP housings RoHS compliant Quality Management System according to ISO 3485:2003 and ISO 900:2008 MEDIA COMPATIBILITY,2 : To be used with gases and liquids which are compatible with the wetted materials (high temperature polyamide, ceramic AL 2 O 3, epoxy, fluorosilicone, glass, silicon). Low pressure port: To be used with non-corrosive, non-ionic working fluids such as clean dry air, dry gases and the like. SPECIFICATIONS Maximum ratings Supply voltage V S... 2 V DC Environmental Temperature ranges Operating -40... +85 C (-40... +25 C) 7 Storage 3-40... +25 C Humidity limits (non-condensing)...95 %RH 8 ( % condensing or direct liquid media on high pressure port ) ELECTRICAL CONNECTION -Vout +Vs 4 +Vout Vibration max. 0 g, 0...2000 Hz, random (EN 068-2-64) 3 Mechanical shock max. 50 g, ms (EN 068-2-27) Lead solder temperature max. 270 C (JESD22-B06D) 2 GND /4
PRESSURE SENSOR CHARACTERISTICS (V S =5.0 V DC, T A =25 C, RH=50 %, pressure applied to high pressure port) Bar pressure ranges Part number HMUM... HMUM350... HMUB00... HMUB2x5... HMUB005... HMUB00... HMUB00A... HMUB004A... HMUB008A... Operating Proof 5 Full-scale span pressure 4 pressure M in. T yp. Max. 0... mbar 2 bar 30 20 0...350 mbar 2 bar 40 0... bar 5 bar 40 0...2.5 bar 0 bar 40 0...5 bar 4 bar 40 0...0 bar 4 bar 40 0... bara 4 bara 30 50 70 0...2 bara 4 bara 40 0...4 bara 8 bara 40 0...8 bara 4 bara 40 Psi pressure ranges Part number HMUM... HMUM350... HMUB00... HMUB2x5... HMUB005... HMUB00... HMUB00A... HMUB008A... Operating Proof 5 Full-scale span pressure 4 pressure M in. T yp. Max. 0... 30 20 4 83 0...5 30 39 98 58 0...5 75 6 03 45 0...35 50 57 96 36 0...70 200 58 96 36 0... 200 4 70 97 0...50 200 6 03 45 0...5 a 58 a 30 5 73 0...30 a 58 a 6 03 45 0... a 200 a 5 86 2 2/4
PERFORMANCE CHARACTERISTICS 2 (V S =5.0 V DC, T A =25 C, RH=50 %, pressure applied to high pressure port) C haracteristics M in. T yp. Max. Z ero pressure offset HMUM... -40 0 40 Temperature effects Offset HMUB00A... -50 0 50 all others -30 0 30 devices -0.44-0.22 0 ( 25...85 C) mbar devices -0.30-0.5 0 Bridge Span impedance 350 mbar/5 devices -0.20-0.07 0 devices -0.5 ± 0.03 0.5 bar/5 absolute devices -0. ± 0.6 0. 2 bar/30 absolute devices -0.30 ± 0.08 0.30 4 bar absolute devices -0.20 0 0.20 all other absolute devices -0.0 ± 0.04 0.0 all others -0.0 ± 0.02 0.0 mbar/ devices -0.23-0.2-0.8 absolute devices -0.23-0.9-0.7 all others -0.2-0.9-0.7 absolute devices 0.25 0.3 0.36 all others 0.24 0.26 0.3 6 Non-linearity mbar/ devices ± 0.50 ±0.90 Bridge resistance absolute devices ± 0.5 ±0.35 all others ± 0.0 ±0.40 absolute devices 2. 8 3. 4 4. 0 all others 2. 8 3. 3 3. 8 Unit %FSS/ C %/ C %FSS kω Specification notes:. All wetted materials are selected to give a high level of media compatibility. Media compatibility refers to media inside the pressure port and lid. Improved media compatibility on high pressure port (backward side of sensor chip) since media has no contact to electronic components. Nevertheless tests with the media used in the specific application are recommended. 2. Sensor is specified in air, changes in sensor behaviour based on physical effects caused by the specific media can occur. Weight of the media and wetting forces can influence the sensor characteristics. 3. Storage temperature of the sensor without package. 4. Proof pressure is the maximum pressure which may be applied without causing durable shifts of the electrical parameters of the sensing element. 5. Full Scale Span (FSS) is the algebraic difference between the output signal for the highest and lowest specified pressure. 6. Non-linearity refers to the Best Straight Line fit, measured for offset pressure, full scale pressure and /2 full scale pressure. 7. Not for all pressure ranges. Please contact First Sensor if operating temperature range -40...+25 C is required. 8. Tested h, up to 85 C. Sensors are electronic components and should be handled only in ESD save environments. 3/4
PHYSICAL DIMENSIONS AND ELECTRICAL CONNECTION HMU...DU...,...AX... (SIL, axial no ports) 2 3 4 High pressure 4/4
HMU...DU7... (SIL, 2 ports axial opposite side, barbed) 2 3 4 5/4
HMU...GX7...,...AX7... (SIL, port axial, barbed) 2 3 4 6/4
HMU...GZ7...,...AZ7... (DIP, port axial, barbed) 5 6 7 4 3 2 8 5 GND 6 GND 7 I / C* 8 I / C* * Internal connection. Do not connect for any reason 7/4
HMU...DU6... (SIL, 2 ports axial opposite side, straight big) 2 3 4 8/4
HMU...GX6...,...AX6... (SIL, port axial, straight big) 2 3 4 9/4
HMU...GZ6...,...AZ6... (DIP, port axial, straight big) 5 6 7 4 3 2 8 5 GND 6 GND 7 I / C* 8 I / C* * Internal connection. Do not connect for any reason 0/4
HMU...DU5... (SIL, 2 ports axial opposite side, needle big) 2 3 4 /4
HMU...GX5...,...AX5... (SIL, port axial, needle big) 2 3 4 2/4
HMU...GZ5...,...AZ5... (DIP, port axial, needle big) 5 6 7 4 3 2 8 5 GND 6 GND 7 I / C* 8 I / C* * Internal connection. Do not connect for any reason 3/4
NOMENCLATURE Differential and Gage devices Options Example: Series HMU M M350 B00 B2x5 B005 B00 HMU B00 Pressure range Pressure mode / Housing Porting Grade mbar / DU Differential, SIL, 2 ports axial * no port P Prime 350 mbar / 5 opposite side 7 Barbed bar / 5 GX G age, SIL, port, axial ( 5) Needle big 2.5 bar / 35 GZ G age, DIP, port axial ( 6) Straight big 5 bar / 70 * not available for Gage 0 bar / / 50 devices, use Differential devices instead ( ) available on request Please contact First Sensor GZ 7 P Absolute devices Options Example: Series HMU B00 B004 B008 HMU B00 Pressure range bar / 2 bar / 5 / 30 AX 4 bar AZ Pressure mode / Housing Porting Grade Absolute, SIL, port axial no port P Prime Absolute, DIP, port axial 7 Barbed 8 bar / ( 5) Needle big ( 6) Straight big ( ) available on request Please contact First Sensor AZ 7 P LABEL INFORMATION Digit 2 3 4 5 6 7 8 9 0 2 3 4 Series Pressure range Pressure unit / pressure mode / calibration Housing Porting Grade/ voltage Char M U - HMU 7 mbar / U bar, U SIL, no port - High, 5 V gage/differential, 2 ports axial J 350 mbar / 5 unidirectional opposite side 7 B arbed + Prime, 5 V A bar / 5 B bar, X SIL, 5 N eedle big / High, 3 V gage/differential, port, axial B 2.5 bar / 35 bidirectional 6 S traight big # Prime, 3 V C 5 bar / 70 A bara, absolute Z DIP, port axial M 0 bar / 50 / 8 bara Production code N 4 bara First Sensor reserves the right to make changes to any products herein. First Sensor does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. 4/4