Diaphragm Accumulators

Similar documents
Diaphragm Accumulators

Bladder Accumulators High pressure

Diaphragm Accumulators

Bladder Accumulators Standard

Bladder Accumulators Standard model

Hydraulic Accumulators with Back-Up Nitrogen Bottles

Hydraulic dampers 2. APPLICATION 2.1. PULSATION DAMPING TYPE SB...P / SBO...P. without damper

Diaphragm Accumulators

Change-Over Pressure Filter DFDK

HYDAC BLADDER ACCUMULATORS INDEX Page: 1. DESCRIPTION FUNCTION CONSTRUCTION MOUNTING POSITION TYPE OF MOUNTING 3 2. APPLIC

3-Way Safety Block DSV

Accumulators Bladder Accumulators. Hydraulics. Technical Information Series CE + ASME. excellent pressure solutions

Accumulators Bladder Accumulators. Hydraulics. Technical Information Series CE + ASME. excellent pressure solutions

Accumulator Technology. Product Catalogue.

Safety and Shut-off Block SAF/DSV

Universal Charging and Testing Unit FPU-1

Safety and Shut-off Block SAF/DSV

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES

Safety and Shut-off Block SAF/DSV

Safety and Shut-off Block SAF/DSV

Safety and Shut-off Block SAF/DSV

Check valve hydraulically pilot operated

Piloted Non-Return Valves

Pressure Reducing Valve DMV 750 set range: bar

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

Flow control valves Series RFU - RFO 2/

ASB Accumulator Safety Blocks

Monoblock Directional Control Valve RMB 202

HYDRAULIC & LUBE OIL UNIT EQUIPMENTS

Self-operated Pressure Regulators Type Universal Pressure Reducing Valve

HIGH PRESSURE FILTERS DFDK Series Inline Duplex Filters 4568 psi up to 90 gpm

STAUFF Accumulators Accessories

Pressure reducing valve, pilot operated

Pressure Reducing Valve DMV 750

Valves. Diaphragm shut-off valves, kidney-type

DIAPHRAGM GAS SAMPLING PUMPS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

Filter pressure regulator, Series AS3-FRE G 3/8 - G 1/2 filter porosity: 5 µm lockable for padlocks with pressure gauge suitable for ATEX

BLADDER ACCUMULATORS type AS and ASP 3.1 E 04-11

Pressure-Relief Cartridge Valve, Size 4

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

Pressure relief valve DHV 716 set range: 0,5-10,0 bar

UPA All fluids. Full flow All stainless steel

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid

BUTTERFLY VALVES. Toll Free (877) - ICFLUID -2-

Pressure relief valve DHV 725 set range: 0,2-10,0 bar

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

Double Pilot Operated Cartridge Check Valve, Size 8

Technical Data Sheet TI-F52 Locking Unit KFHL Certified by Lloyd s Register

Pressure Reducing Valve DMV 755 set range: 1,0-9,0 bar

FLUID SIDE S SAFETY EQUIPMENTS 9 E 01-12

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series

Serie 06-M6. Swing wafer check valve. made in. Application fields. Check valves E U R O P E WATER CONDITIONING INDUSTRY

Pressure regulators Manually operated Fine setting valves. Brochure

BLADDER ACCUMULATORS type AS and ASP 3.1 E 01-12

Pressure Reducing Valve

Compressed Air Conditioning Catalog Chapter I

Pressure relief valve, direct operated

Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1

SIHI LPH-X - Liquid Ring Compressors

3-Way Pressure-Reducing Cartridge, Size 2 4

Diaphragm accumulator type AC

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

JRGURED Pressure reducing valves

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

UPA All fluids. Full flow All stainless steel

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

Air-service devices, Series MU1

Pressure Reducing Valve DMV 755

T 2523 EN Type 2406 Excess Pressure Valve Self-operated Pressure Regulators ANSI version

UPB All fluids. Full flow All stainless steel

Hydraulic Piston Accumulators

Self-operated Pressure Regulators for special applications

Pressure relief valve, direct operated

Type 4708 Supply Pressure Regulator

Pressure relief valves

Differential pressure gauge For the process industry Model , all-metal media chamber

3/2-way valve, Series CD07 Qn= 1400 l/min pipe connection compressed air connection output: G 1/4 - M14x1,5 suitable for ATEX

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Flow and check valves Non-return valves Series NR02. Brochure

Pressure-limiting valve and pre-load valve type MVG, MVE and MVP

D 042 D 062 In-line mounting Operating pressure up to 100 bar Nominal flow rate up to 90 l/min

Cost effective. Smooth. Reliable. LOG Internal Hole Gripper

KSB Delta Compact Type Series Booklet

Diaphragm Valve, Metal

Proportional Throttle Cartridges, Size 16

R300 HELYON. Brass high pressure regulator, for compressed air, gas and liquids

Ball valve HKSF-W100. Ball valve HKSF-W100. RMA Kehl GmbH & Co. KG Oststrasse 17 D Kehl / Germany

Directional valves Pneumatically operated Series CD07. Brochure

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. AWA Change-over Valve

ARI-DP32 / DP33 / DP34 / DP34T / DP34Tri / DP35 Pneumatic actuator ARI-DP

Precision pressure regulators LRP/LRPS

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X

Pressure reducing valve, pilot operated, Model 3DR

Diaphragm accumulator type AC

Solenoid valves VZWF, force pilot operated

Type BBS-03, BBS-05, BBS-06, BBS-25

Pressure relief valve, direct operated Type DBD

Transcription:

Diaphragm Accumulators. DESCRIPTION.. FNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas is utilised in hydraulic accumulators for storing fluids. HYDAC diaphragm accumulators are based on this principle, using nitrogen as the compressible medium. Diaphragm accumulators consist of a fluid section and a gas section with the diaphragm acting as a gas-tight separation element. The fluid section is connected to the hydraulic circuit so that the diaphragm accumulator draws in fluid when the pressure increases and the gas is compressed. When the pressure drops, the compressed gas expands and forces the stored fluid into the circuit. Set into the base of the diaphragm is a valve poppet. This shuts off the hydraulic outlet when the accumulator is completely empty and thus prevents damage to the diaphragm. Note: HYDAC diaphragm accumulators when fitted with a HYDAC safety and shut-off block comply with the regulations of the European Pressure Equipment Directive (PED) and the German Industrial Safety Regulations (Betr.Sich.V.). See catalogue section: zsafety and Shut-off Block SAF/DSV No. 3.55.2. DESIGN HYDAC diaphragm accumulators are available in two versions..2. Weld type rechargeable pressure vessel diaphragm valve plate valve body sealed gas connection This consists of: zwelded pressure vessel, rechargeable on the gas side or, alternatively, completely sealed. Fluid connection available in various types. zflexible diaphragm to separate the fluid and gas sections. zvalve poppet set into the base of the diaphragm..2.2 Screw type locking screw pressure vessel diaphragm valve plate valve body.2.3 Diaphragm material The diaphragm material must be selected in accordance with the particular operating fluid or operating temperature, see section.5. If discharge conditions are unfavourable (high p 2 /p 0 pressure ratio, rapid discharge speed), the gas may cool to below the permitted temperature. This can cause cold cracking. The gas temperature can be calculated using the HYDAC Accumulator Simulation Program ASP. This consists of: zforged upper section with gas charging connection. zforged lower section with fluid connection. zexchangeable flexible diaphragm to separate the gas and fluid. zvulcanized valve poppet set into the base of the diaphragm. zlock nut to hold the upper and lower sections of the accumulator together..2.4 Corrosion protection For use with chemically aggressive fluids the accumulator can be supplied with corrosion protection, such as plastic coating or a galvanic or chemical surface protection. If this is insufficient, then almost all types can be supplied in stainless steel..3. INSTALLATION POSITION Optional. However, if there is a risk of contamination collecting, a vertical position is preferable (fluid connection at the bottom). E 3.00.27/0.7 63

.4. TYPE OF INSTALLATION Accumulators up to 2 l can be screwed directly inline. Where strong vibrations are expected, the accumulator must be secured to prevent it working loose. For weld type accumulators we recommend HYDAC support clamps. For screw type accumulators with lock nut, a suitable support console can be ordered. For additional male thread on the hydraulic connection for screwing into mounting holes, see table 3.. See catalogue section: zsupports for Hydraulic Accumulators No. 3.502.5. GENERAL.5. Permitted operating pressure see tables 3.. and 3.2. The permitted operating pressure can differ from the nominal pressure for foreign test certificates..5.2 Nominal volume see tables 3.. and 3.2..5.3 Effective gas volume corresponds to the nominal volume of the diaphragm accumulator..5.4 Effective fluid volume Volume of fluid which is available between the operating pressures p 2 and p..5.5 Gas charging All accumulators are supplied with a protective pre-charge. Higher gas pre-charge pressures are available on request (gas charging screw or sealed gas connection). Hydraulic accumulators must only be charged with nitrogen. Never use other gases. Risk of explosion! In principle, the accumulator may only be charged with nitrogen class 4.0, filtered to <3 µm. If other gases are to be used, please contact HYDAC for advice..5.6 Limits for gas pre-charge pressure p 0 0.9 p For diaphragm accumulators with PTFE diaphragms, the following applies: p 0tmax 200 bar for further information, see catalogue section: zhydac Accumulator Technology No. 3.000.5.7 Permitted pressure ratio Ratio of maximum operating pressure p 2 to gas pre-charge pressure p 0..5.8 Max. flow rate of the operating fluid In order to achieve the max. flow rate given in the tables, a residual fluid volume of approx. 0 % of the effective gas volume must remain in the accumulator. The maximum fluid flow rate was determined under specific typical conditions and is not applicable in all operating conditions..5.9 Working temperature and operating fluid The permitted working temperature of a diaphragm accumulator is dependent on the application limits of the metal materials and the diaphragm. Outside this temperature range, special materials must be used. The operating fluid must also be taken into account. The following table displays a selection of elastomer materials with temperature range and a rough overview of resistant and non-resistant fluids, on a case-by-case basis, information must be requested regarding the resistance and the resistance must be tested specifically: Materials NBR Acrylonitrile butadiene rubber Material Temperature range Overview of the fluids 2) code ) Resistant to 2 5-5 C... + 80 C -50 C... + 50 C zmineral oil (HL, HLP) zflame-resistant fluids from the groups HFA, HFB, HFC zsynthetic ester (HEES) zwater zsea water Not resistant to zaromatic hydrocarbons zchlorinated hydrocarbons (HFD-S) zamines and ketones zhydraulic fluids of type HFD-R zfuels ECO Ethylene oxide epichlorohydrin rubber 3-40 C... +20 C zmineral oil (HL, HLP) zflame-resistant fluids from the HFB group zsynthetic ester (HEES) zwater zsea water IIR Butyl rubber 4-50 C... +20 C zhydraulic fluids of type HFD-R zflame-resistant fluids from the group HFC zwater FKM Fluorine rubber 6-0 C... +50 C zmineral oil (HL, HLP) zhydraulic fluids of type HFD, zsynthetic ester (HEES) zfuels zaromatic hydrocarbons zinorganic acids ) see section 2.. Model code, material code, diaphragm 2) others available on request zaromatic hydrocarbons zchlorinated hydrocarbons (HFD-S) zamines and ketones zhydraulic fluids of type HFD-R zflame-resistant fluids from the groups HFA and HFC zfuels zmineral oils and mineral greases zsynthetic ester (HEES) zaliphatic, chlorinated and aromatic hydrocarbons zfuels zamines and ketones zammonia zskydrol and HyJet IV zsteam E 3.00.27/0.7 64

.5.0 Certificate codes Hydraulic accumulators which are installed in countries outside Germany are supplied with the test certificates required in that country. The country of installation must be stated at the time of ordering. HYDAC pressure vessels can be supplied with virtually any test certificate. Please note that the permitted operating pressure can differ from the nominal pressure. The following table contains a few examples of the codes used in the model code for different countries of installation: Country Certificate code (AKZ) E member states Australia F ) Belarus A6 Canada S ) China A9 Hong Kong A9 Iceland Japan P Korea (Republic) A New Zealand T Norway Russia A6 South Africa S2 Switzerland Turkey kraine A0 SA S ) Registration required in the individual territories or provinces. others on request On no account must any welding, soldering or mechanical work be carried out on the accumulator shell. After the hydraulic line has been connected it must be completely vented. Work on systems with hydraulic accumulators (repairs, connecting pressure gauges etc.) must only be carried out once the fluid pressure has been released. The operating instruction must be followed! No. 3.00.BA Note: Application examples, accumulator sizing and extracts from approvals regulations on hydraulic accumulators can be found in the catalogue section: zhydac Accumulator Technology No. 3.000 2. TECHNICAL SPECIFICATIONS 2.. MODEL CODE Not all combinations are possible. Order example. For further information, please contact HYDAC. Series Nominal volume [l] Type Weld type: E = rechargeable M28x.5 E2 = sealed gas connection, with gas pre-charge as requested ) E3 = rechargeable, gas valve M6x.5 / M4x.5 Screw type A6 = rechargeable M28x.5, exchangeable diaphragm A3 = gas valve M6x.5 / M4x.5, exchangeable diaphragm Material code dependent on operating medium standard model = 2 for mineral oils Fluid connection = carbon steel 3 = stainless steel 2) 4 = carbon steel with protective coating 3) 6 = low-temperature steel 7 = other materials Accumulator shell 0 = plastic coating = carbon steel 3) 4) 2 = carbon steel with protective coating 4 = stainless steel 2) 6 = low-temperature steel 7 = other materials Diaphragm 2 = NBR 5) 3 = ECO 4 = IIR 5 = NBR 5) 6 = FKM 7 = other materials (e.g. PTFE, EPDM,...) Certification code = European Pressure Equipment Directive (PED) Permitted operating pressure [bar] Fluid connection form Standard connection = AK or AB e.g. form AK = G 3/4 for SBO20-2 see section 3. SBO20 2 E / 2 20 AK 050 Pre-charge pressure p 0 [bar] at 20 C, must be stated clearly, if required! ) ) only for E or E2 design, when ordered as standard 2) dependent on type and pressure level 3) only for screw-type design 4) only for parts that come into contact with fluid 5) Observe temperature ranges see section.5. E 3.00.27/0.7 65

3. TECHNICAL DATA 3.. WELD TYPE non-exchangeable diaphragms 3.. Drawings Fig. Design Gas side connection Fluid side connection* E E2 E3 AK AB +2 2 3 on request 4 * = alternative fluid connections on request E 3.00.27/0.7 66

3..2 Dimensions Nom. vol. ) Perm. press. ratio E 3.00.27/0.7 Series [l] p 2 : p 0 steel Carbon Certificate code Permitt. oper. pressure [bar] R ØD Weight Q 2) Stainless steel [kg] [l/min] Standard fluid connection Form AK F ISO 228 ØG L B SW Form AB F ISO 228 H DIN 3 0.075 8 : 250 250 9 64 0.7 38 G /2 4 2 30 0.6 8 : 20 20 80 03 74 0.8 38 G /2 4 2 30 300 300 08 78. not available 0.32 8 : 20 20 60 6 93.3 300 300 20 96.8 95 G /2 4 2 30 0.5 8 : 60 60 30 02.3 20 20 33 05.7 95 G /2 4 2 30 G /2 M33x.5 4 37 4 0.6 8 : 330 330 5 5 3.3 4 4 95 G /2 34 4 2 G /2 M33x.5 4 37 350 350 30 2 3.5 50 50 3 0.7 8 : 00 00 5 06.8 95 G /2 34 4 2 4 G /2 M33x.5 4 37 4 0.75 8 : 40 40 42 6.8 4 37 20 20 40 47 2 2.8 2 95 G /2 34 4 4 G /2 M33x.5 4 250 250 52 26 3.6 5 42 330 330 40 26 4 26 3 8 : 200 200 59 36 3.6 2 95 G /2 34 4 4 G /2 M33x.5 4 37 250 250 92 4.4 4 2 4 : 26 330 330 69 4.8 26 5 42 4.4 8 : 40 40 73 45 3.9 4 20 20 78 50 5.4 2 37 95 G /2 34 4 4 G /2 M33x.5 4 250 250 85 53 5.9 5 330 330 72 55 7.6 33 42 3 00 00 00 90 60 4 8 : 20 20 98 67 6.6 28 33 2 50 G 3/4 44 6 46 G 3/4 M45x.5 6 46 4 : 250 250 232 53 7.4 2 8 : 330 330 8 72 9.2 43 42 3 2.8 20 20 250 67 8.2 28 33 2 4 : 250 250 250 70 9.5 50 G 3/4 44 6 46 G 3/4 M45x.5 6 46 237 43 4 330 330 72 42 6 : 23 44 3 3.5 4 : 250 20 306 70.2 28 33 2 50 G 3/4 44 6 46 G 3/4 M45x.5 6 46 330 330 274 72 3.8 44 42 4 4 4 : 50 50 294 58 5 250 80 306 70.2 50 G 3/4 44 6 44 46 G 3/4 M45x.5 6 33 46 2 ) others on request 2) max. flow rate of operating fluid L B2 SW Fig. 67

3.2. SCREW TYPE exchangeable diaphragm 3.2. Drawings Type A6 Type A3 Fluid port AK alternative fluid connections on request Figure 5 3.2.2 Dimensions Nom. vol. ) Perm. press. ratio E 3.00.27/0.7 Series Certificate code Permitt. oper. pressure [bar] [l] p 2 : p 0 steel Carbon Weight A B ØD ØL M N O ØP R Q 2) Standard fluid connection Stainless steel [kg] [l/min] Form AK F ISO 228 0. 0 : 500 500.9 0 30 95 53 35 95 G /2 4 36 0.25 0 : 500 500 3.9 5 56 29 20 92 56 350 4.9 25 60 S 95 G /2 4 750 750 9 36 53 4 57.5 63 M6 40 2 27 0.6 0 : 450 450 250 5.7 70 9 40 5 68 57 95 G /2 4 34 4.3 0 : 400 400.2 22 28 99 60 97 65 M8 80 0 50 G 3/4 6 44 50 2 0 : 250 250 80.4 227 7 20 68 0 64 M8 88 0 50 G 3/4 6 44 50 2.8 0 : 400 400 22 257 30 252 207 06 80 M8 230 0 50 G 3/4 6 44 50 4 0 : 400 400 34 284 30 287 236 27.5 90 M8 265 0 50 G 3/4 6 44 50 ) others on request 2) max. flow rate of operating fluid ØG K SW 36 Figure 5 68

4. SPARE PARTS 4.. WELD TYPE non-exchangeable diaphragms Description Quantity Item Spare parts set for gas side consisting of: Locking screw 20 Protective cap 20 2 Seal ring 20 3 Nominal volume [l] Part no. NBR ECO FKM IIR PTFE Spare parts set for gas side 0.075-4 3262845 - - - - 4.2. SCREW TYPE exchangeable diaphragm Description Quantity Item Spare parts set for gas side consisting of: Locking screw 20 Protective cap 20 2 Seal ring 20 3 Spare parts kit for elastomer diaphragm consisting of: Locking screw Seal ring 3 Elastomer diaphragm 4a Back-up ring 5a Spare parts kit for PTFE diaphragm consisting of: Locking screw Seal ring 3 PTFE diaphragm 4b O-ring 5b Nominal volume [l] Part no. NBR ECO FKM IIR PTFE Spare parts set for gas side 0. - 4 3262845 - - - - Spare parts kit 0. 3042668 382526 - - - 0.25 3042709 304272 304274 304273 3504798 0.6 304270 304275 304277 304276 3550388.3 304268 3042682 3042684-3446897 2 30427 304279 304272 3042720 3464205 2.8 3042700 304270 3042704 3042702-4 3042705 3042706 3042708 3042707 - When replacing seals and/ or diaphragms, please read the Instructions for Assembly and Repair (No. 3.00.M). 4. NOTE The information in this brochure relates to the operating conditions and applications described. For applications or operating conditions not described, please contact the relevant technical department. Subject to technical modifications. HYDAC Technology GmbH Industriegebiet 66280 Sulzbach/Saar, Germany Tel.: +49 (0) 68 97 / 509-0 Fax: +49 (0) 68 97 / 509-464 Internet: www.hydac.com E-Mail: speichertechnik@hydac.com E 3.00.27/0.7 69

E 3.00.27/0.7 70