Eaton Filtration, LLC

Similar documents
Eaton Filtration, LLC

TITAN FLOW CONTROL, INC.

APCO ARV CLEAN WATER AIR RELEASE VALVES. Model 50A

TITAN FLOW CONTROL, INC.

FloWash. Industrial Filter Cart

Engineering Data Sheet

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

DUPLEX TECHNICAL INFORMATION FABRICATED DUPLEX STRAINERS

BS Series Basket Strainer

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914

1805 Series Relief Valves

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

HIGH RATE BASKET STRAINER

INSTALLATION & MAINTENANCE INSTRUCTION

Installation, operation & maintenance manual - original version

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

GREIG FILTERS, INC. OPERATION MANUAL

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

HAYWARD FLOW CONTROL FLV SERIES, PVC/CPVC FILTER VESSEL INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

D05 Pressure Regulating Valves

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

TD45 Thermodynamic Steam Trap Installation and Maintenance Instructions

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7

4 IN. BALL LAUNCHER Engine Mounted / PTO Driven

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

Installation, Operation, and Maintenance Manual

MEGR-1912 Instruction Manual

APCO ARV CLEAN WATER AIR RELEASE VALVES. Model 50A

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

Anderson Greenwood Series 93 Positive Pressure POSRV Installation and Maintenance Instructions

WHEATLEY Series 500 Swing Check Valve

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

WW-730. Pressure Sustaining/Relief Control Valve

TROUBLESHOOTING GUIDELINES

Bermad Pressure Reducing. Model: 42T

Bray/ VAAS O-Ported Series Knife Gate Valve 770/780 Series Operation and Maintenance Manual

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

Product Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction

Spilt body Flange ball valve. TC-205MFF-PN1640 User Manual English Version. Document No: TC-205MFF-PN1640.Ur-manual. Date: 2007/04/2617. Version: 1.

Atmospheric relief valve type 1100 Installation and maintenance instructions

SALCO PRODUCTS, INC. PRESSURE RELIEF VALVE STORAGE, INSTALLATION, OPERATING, MAINTENANCE/TESTING, AND INSPECTION INSTRUCTIONS

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

MEGR-1627 Instruction Manual

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Model PIV UL/FM Post Indicator Valve. Maintenance and Operation Manual UL/FM Post Indicator Valve Configuration AWWA C515

MUELLER GAS. No-Blo Operations Using D-5. Drilling Machine. Reliable Connections. General Information 2

Armored Gauge O S & Y Bolted Bonnet Valves Series BB-100

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection

SCA Series Inverted Bucket Steam Traps

Model: 43T. Bermad Pressure Relief Valve

Cast iron swing check valve. BS EN 12334:2001 PN16

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

Manual Actuated Boiler Blowdown Valves

64 Series Pressure Reducing Regulators

756 Safety Relief Valves

Installation, Operation, and Maintenance Manual

CA10S, CA14 and CA14S Air and Gas Traps

North American Simplex Basket Strainers for Gas and Oil

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING

BCV31 DN20 - Blowdown Control Valve

Temperature Controllers

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

Anti-flood device Model B-1

INSTALLATION / OPERATION / MAINTENANCE INSTRUCTION

DelVal Flow Controls Private limited

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

1301 Series High-Pressure Regulators

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

Installation Instructions, Pressure Regulator Series

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Float Operated Level Controllers

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators Installation and Maintenance Instructions

TITAN FLOW CONTROL, INC.

Apollo Standard Port, Full Port & One Piece Flanged Ball Valves Installation, Operation, & Maintenance Manual

Pure-Flo Handwheel Operated Valves (903, 913, 963) Instruction Manual

Pure-Flo Handwheel Operated Valves (970) Instruction Manual

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP

Fisher DVI Desuperheater Venturi Inline

INSTALLATION, OPERATION & MAINTENANCE MANUAL

FRYSAFE COOKING OIL FILTRATION I&O MANUAL

Installation, Operation and Maintenance Instructions for Pacific PA Non-Storage Heat Exchanger

Dri-Line Mk3 Monnier Compressed Air Drain Trap

IFTGS14 Ball Float Steam Trap ½" and ¾" with Integral Spiratec Sensor

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

Telefon (+45) Telefax (+45)

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

TECHNICAL DATA. Q = C v P S

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

Transcription:

Eaton Filtration, LLC 900 Fairmount Avenue, Elizabeth, NJ 07207 Phone: 908-787-1000 Fax: 908-351-7893 E-Mail: filtration@eaton.com Web: www.filtration.eaton.com Installation, Operation & Service Manual Model 50 Duplex Basket Strainer 3/4 to 8 Sizes Read all instructions before installation or operation of equipment. Failure to comply with these instructions could result in bodily injury or property damage. Table of Contents Page No. Introduction. 1 Receiving, Handling & Inspection 1 Installation 2 Operation. 3 Start Up 3 Basket Removal/Replacement 4 Basket Cleaning. 4 Recommended Spare Parts... 4 Exploded Parts Drawing.. 5 Introduction A duplex strainer is a device installed in a pipeline to remove dirt and other unwanted debris from fluids. Straining is accomplished by directing the fluid through sized openings in a basket. Duplex strainers are installed where fluid flow cannot be interrupted while the basket is removed for cleaning. Duplex strainers are designed for pressure and suction installations. For additional information regarding Duplex Basket Strainers visit out website at: www.filtration.eaton.com Receiving, Handling and Inspection Inspect strainer after unpacking for damage incurred during transit. Report any damage to the carrier immediately. If the strainer is not to be installed immediately, store indoors in a clean, dry environment. Remove preservative with solvent dampened cloths. Exercise care when using solvent. Check to be sure the rated pressure and temperature on the strainer name plate is not less than the maximum pressure and temperature of the installation. The rated pressure shown on the name plate is the maximum pressure, including shock pressure, at which the strainer may be operated. 1 IOM 50 3/4-8 01/06

Installation Position the strainer in the line so that the fluid enters the connection marked inlet. Be sure sufficient headroom is provided for easy removal of cover and baskets. CAUTION: Lift strainers with slings under the inlet and outlet connections. DO NOT lift the strainer by the jack bonnet located on top of the plug. Support the strainer in the line as follows: 3 Size or Under Use pipe supports under the process piping near inlet and outlet connections. Use care to prevent bending and expansion forces from action on the nozzles. 4 Size or Larger Support on concrete or steel pads. Connect the strainer to the line. Use same type flange faces. For example, DO NOT bolt raised face flanges to iron flat face flanges. Iron flanges must be flat face with full face gaskets. Cast strainers are subject to face to face variations due to shrinkage and machining tolerances. Prefabricated piping systems must allow adjustment at the strainer connections. Installation, Continued Be sure flange gaskets are in place and fasteners are tight. It is recommended that the drain plugs be removed and drain valves be installed at the bottom of each basket chamber as shown in Figure 1. A pressure equalizer, as shown in Figure 2, should be installed when the operating pressure exceeds 50 psi. This pressure equalizer greatly reduces the force required to transfer the position of the strainer valve plug. To insure proper valve plug seating, the clean-out plug at the bottom of the valve plug chamber should be periodically removed and the accumulated solids and debris washed out. CAUTION: A vent is required when fluids other than water and with temperatures in excess of 120 F are to be handled by the strainer. The vent must be piped to a safe discharge point to protect the operator (see Figure 3). Wear protective clothing which includes gloves, vests, and goggles when handling dangerous fluids. Pressure gauges near the strainer inlet and outlet are recommended. Cleaning frequency can be determined by the pressure drop across the strainer. For threaded strainers, use standard pipe practice when making connections. 2

Operation The chamber in operation can be determined by observing the position of the valve handle. The handle is on the same side of the center line as the chamber in operation (see Figure 4). Start up, Continued NOTE: The strainer valve plug is intended to divert flow. It is not designed to provide absolute tight shut off. Product design criteria requires valve plug seepage to be low enough to provide time for basket cleaning only. Shut Down Tightly close pipeline valve on inlet and outlet connections of the strainer. Open vents, (see figure 3), to relieve liquid pressure in the strainer. CAUTION: DO NOT loosen body covers while there is liquid or air flow from the vent. Start up Open both chamber vents, if strainer is so equipped (see figure 3), to expel air from the strainer. Position valve handle in the center to allow both chambers to fill and close the equalizer valve, if strainer is so equipped (see figure 2). Slowly allow fluid to enter strainer by opening OUTLET valve first, then followed by opening the INLET valve. CAUTION: Start system GRADUALLY. This eliminates sudden shock to strainer and other equipment in the line. Close vents when air is expelled and fluid begins to leak out vent. Move valve handle to extreme travel position over one clean basket. DO NOT leave valve handle in the center position as both baskets will become dirty. This would require interrupting flow to clean them. Seat valve plug lightly by turning valve yoke clockwise. To avoid excessive stresses, stuck valve plugs etc. when operating at temperatures above 120 F use only minimum hand pressure on the valve yoke to position the valve plug against the seat. The valve plug should be firmly seated during basket cleaning to prevent excessive leakage into the opened chamber. Switching Flow Without Equalizer Turn lifting handle counterclockwise to lift valve plug and position turning handle (to extreme travel position) over clean basket. Seat valve plug slightly by turning lifting handle clockwise. With Equalizer Open pressure equalizer valve and turn lifting handle counterclockwise to lift valve plug. Position turning handle (to extreme travel position) over clean basket and seat valve plug tightly by turning lifting handle clockwise. Close equalizer valves. Basket Removal (Yoke Cover) Transfer flow from dirty to clean chamber (see Switching Flow) and open vents, and/or drain valve to relieve liquid pressure in dirty chamber. When pressure is relieved, loosen, but do not remove, T-bolt. Then drain fluid away through the chamber drain connection to a level below the basket seat. This prevents by-pass of dirty fluids. Swing yoke away from body yoke stud and clear of body cover. Remove cover. Remove dirty basket. 3

Basket Replacement (Yoke Cover) Place new or clean basket squarely on basket seat and be sure the basket handle is sufficiently high to be compressed by the strainer body cover. Inspect body cover O-ring and seal surface. Clean seat and replace body cover O-ring as necessary. Always keep spare O-ring gaskets in storage. Replace body cover, making sure body cover is centered in body opening. If strainer is on suction service, fill basket chamber from outside source before installing body cover. Swing yoke into position over body cover and onto yoke stud, making sure yoke is level with body. If not, adjust both studs to level the yoke. Hand tighten yoke studs and tighten the center T- bolt. Make sure vent is open, if strainer is so equipped, (see Fig 3); close drain valve and refill basket chamber with fluid as follows: Lift valve plug and rotate valve plug handle approximately 20 towards center position until all air is vented from the basket chamber. Close vents and return valve plug handle to extreme position and reseat tightly. With Equalizer Open pressure equalizing valve. Close vent when air is expelled. Close pressure equalizing valves. Basket Cleaning When to Clean Clean baskets when there is a 5 PSI increase in the pressure loss across the strainer When to Clean, Continued During shutdown for a temporary period, drain fluid and clean baskets. How to Clean Invert basket and wash out debris by directing a stream of air or water against the basket exterior. Follow manufacturer s instructions when using a solvent to clean the baskets. NOTE: Do not allow basket contents to dry as this will make cleaning most difficult. Inspect baskets at each cleaning for holes or tears, replace as required. Always keep spare baskets in stock. Shutdown Periods During shutdown periods: Remove valve plug from strainer. Apply a heavy coat of grease to both the valve plug and the plug cavity in the strainer body. Replace valve plug and its cover. Do not seat valve plug until strainer is again placed into service. Recommended Spare Parts 1 Eaton Replacement Basket 1 Eaton Replacement Gasket When ordering spare parts specify all nameplate data as well as the description and quantity of parts. Always use genuine Eaton replacement parts for guaranteed fit and performance. Visit our web site, www.filtration.eaton.com for information about the different types of Eaton Duplex Basket Strainers. CAUTION: To prevent damage to the baskets, DO NOT permit strainer pressure differential between inlet and outlet connections to exceed 20 PSI. 4

EXPLODED VIEW 5

More From Eaton Filtration Pipeline Strainers Eaton provides the most complete range of standard cast pipeline strainers for coarse filtration available from any manufacturer. These include Simplex, Duplex and Y Type Strainers, in Iron, Bronze, Carbon and Stainless Steel. For ultra-pure applications, strainers of all plastic construction are available. Cast Pipeline Strainers range in size from 1/2 to 36 and larger. When a cast strainer won t meet the applications requirements because of size, weight or design Eaton offers standard fabricated strainers to meet exact customer requirements. without any trade-offs. When a standard design fabricated strainer will not meet an application s requirements Eaton s design team can work with customers to create a unique one that will. Eaton also offers Automatic Self- Cleaning strainers. These are motorized strainers designed for the continuous removal of entrained solids from liquids in pipeline systems. The strainer operates un-attended and the system flow never has to be shut down for strainer element cleaning. These strainers are available in both cast and fabricated types. Find out more on the web at: www.filtration.eaton.com Gas/Liquid Separators Eaton s Gas/Liquid Separators have been the Industry Standard for over 100 years. Nobody knows more about gas/liquid separation than us. Eaton Gas/Liquid Separators are used to remove 99% of damage causing moisture and particulate matter from air, gas and steam pipelines. They protect valuable system components like air compressors and turbines from damage. Eaton has a wide selection with hundreds of different Gas/Liquid Separators. When a standard model isn t right for an application, Eaton Engineers can work with customers to create a custom fabricated model that fits the application requirements exactly. Find out more on the web at: www.filtration.eaton.com Filtration Systems With Eaton Filter Housings you have your choice of high grade investment cast construction or engineered fabricated construction in stainless steel or carbon steel. Or, for extremely corrosive or ultra-pure services, you can choose all-plastic construction. You can be sure Eaton Filter Housings will meet specifications because they are all made to ISO 9001:2000 Standards. Eaton has representatives in over 40 countries, experienced professionals to provide the filtration help you need, when and where you need it. Choosing the correct filter bag is critical to the success of you application. Don t trust anything less than a filter bag from Eaton. They re made under ISO 9001:2000 Standards to ensure the consistent, reliable performance that you demand. Eaton Filter Bags fit all Eaton Filter Housings and the housings of most other manufacturers as well. Find out more on the web at: www.filtration.eaton.com Eaton Filtration warranties its products against defective material and workmanship only. Eaton assumes no responsibility for damage or injury resulting from improper installation, abuse, or misapplication of any product. Eaton assumes no responsibility for damage or injury resulting from chemical incompatibility between its products and the process fluids to which they are subjected. The end user should always test to determine application suitability. Contact your Eaton Representative for complete warranty information. Eaton Filtration, LLC 900 Fairmount Avenue, Elizabeth, NJ 07207 Tel: 908-787-1000 Fax: 908 351 7893 E-Mail: filtration@eaton.com Web: www.filtration.eaton.com Copyright 2005 Eaton Filtration, All rights reserved. 6