SFC1480FX SFC2480FX series

Similar documents
Pamphlet. 1480G 2480G series. Hitachi Metals, Ltd.

PS100 Series. Pressure-Based PI Mass Flow Controller. Catalog

Catalog. Series. Pressure Insensitive (PI) Mass Flow Controller. Series. Digital Mass Flow Controller (non-pi), Mass Flow Meter

TKF Mass Flow Controller. FCS Thermal Series. Digital interface 준비장비 (RS-485)

Aera PI-980 Series Pressure- Insensitive MFCs

Catalog. Aera. FC-PIR98x. Series Pressure- Insensitive MFCs. Next-generation PI technology for tomorrow s manufacturing demands

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

Aera Industrial MFC Product Guide. Innovative Control at Work

Mass Flow Controllers

Mass Flow Controller (MFC) for Gases

TH-1800-T TRX-700-CNG Converter

Mass Flow Controller (MFC) for Gases

Mass Flow Meter (MFM) for gases

Mass Flow Controller (MFC) for Gases

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

Model 601CV. Mass Flow Controller. Product Features:

High Performance Mass Flow Controller

Bypass Mass Flow Controller (MFC) for gases

MACH ONE MASS FLOW CONTROLLER. MACH ONE SERIES flow control. MASS FLOW CONTROLLERS at the speed of sound.

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

Mass Flow Controller (MFC) for Gases

Quick Installation Guide Doc nr.: C Date:

Mass Flow Controller (MFC) for gases. Inline MFC for nominal flow rates from 25 I N. /min to I N

INSTALLATION & MAINTENANCE INSTRUCTIONS

Mass Flow Controller (MFC) for Gases

TELEDYNE HASTINGS INSTRUMENTS PRELIMINARY BULLETIN. Models HFM-D-301 & 305, HFC-D-303 & 307

Mass Flow Meter (MFM) for Gases

GasSense NDIR User Manual

Technical Data Sheet High Performance Digital Gas Mass Flow Meters and Controllers Features Description

CORI-FLOW PRECISION MASS FLOW METER / CONTROLLER FOR LIQUIDS AND GASES

GAS FUEL VALVE FORM AGV5 OM 8-03

Mass Flow Controller (MFC) for Gases

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

T EK-SUB 4800C 19 mm Submersible Level Transmitter

Digital Mass Flow Meters and Controllers for Gases

UNDERSTANDING, ACCELERATED

The Ins and Outs of I/P Transducers

Design Features. General Description

GP1 & GP2. Electropneumatic Regulators FOR PRESSURE CONTROL TO 1,000 PSI

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

75 Allen Street Lexington, MA Minute Model & Pricing Overview Guide

How to specify a product. Process Sensors and Mechanical Instruments

SCOPE OF THIS GUIDE STARTING-UP. 1 Check mini CORI-FLOW functional properties

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

EPR High Precision 3000 psi Electronic Pressure Controller Accurate to 0.25% of full scale

AMS 2710 PCB pressure sensor module with V output

Model PDT Dewpoint Transmitter

Installation, operating and maintenance Instructions for Seemag bypass level indicator

IN-FLOW CTA Industrial Mass Flow Meters and Controllers for Gases

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

800 Series Mass Flow Meters and Controllers. High Performance Mass Flow Meters and Controllers

86BSD Backside Digital Output

Hitachi Differential Pressure/Pressure Transmitter

780S Ultra High Purity Series

Features. Description

For a similar sensor with o-ring mounting, refer to the 85BSD digital output pressure sensor.

Flow Meters and Flow Controllers

Digital Flow Switch. Series PFM7

DF-550E PROCESS ANALYSERS APPLICATIONS FEATURES

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司

GAS Piezo Actuator Type Mass Flow Controllers

ALL-IN-ONE MINI THERMAL MASS FLOWMETER

Products Guidance. Combined catalog GAS LIQUID VACUUM ANALYSIS. Vacuum Measurement. Technology. Flow Control Technology. Liquid Source Vaporization

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

Variable Area Flow Meters

2/ Port G1/4

TR Electronic Pressure Regulator. User s Manual

HumiSys HF High Flow RH Generator

BUBBLER CONTROL SYSTEM

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

DF-310E PROCESS ANALYSERS APPLICATIONS FEATURES

Model 130M Pneumatic Controller

Alphasense 4-20 ma transmitters offer convenience and easy maintenance for toxic sensors:

COMPARISON OF DIFFERENTIAL PRESSURE SENSING TECHNOLOGIES IN HOSPITAL ISOLATION ROOMS AND OTHER CRITICAL ENVIRONMENT APPLICATIONS

REASONS FOR THE DEVELOPMENT

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

EPP4 Pressure Regulator Basic G 1/4"

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2

GAS Solenoid Actuator Type Mass Flow Controllers

DPS-400 SERIES DPH-100 SERIES

T EK-COR 1100A Coriolis Mass Flowmeter

Differential Pressure Transmiter

BUBBLER CONTROL SYSTEM

DPC-30 DPC-100. Reference Manual

Model FS5001B VA.1. MEMS Mass Flow Sensors ISO 9001 ISO OHSAS 18001

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

Digital electro-pneumatic regulators Series ER100

SmartTrak 100HP. Ultra-High Pressure Digital Gas Mass Flow Meters & Controllers. FEATURES DESCRIPTION

MASFLO-OVAL Ⅱ THERMAL MASS FLOWMETER/CONTROL VALVE for GAS MEASUREMENT MODEL: FHC, FHD series

Air Bubbler Depth Gauge DG2200 Installation and Reference Manual

TEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL

FTC130 Transmitter. Operating Manual

3.0 Pressure Transmitter Selection

RCD - Ultra-Rugged Differential Pressure Flowmeter

Porter Analytical & Industrial Products

Integral type Differential pressure flowmeter VNT Series

MCQ Gas Blender 100 Series 3 Channels Gas Mixer

MANUAL KPS Pressure Control Valve

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

Transcription:

Pamphlet SFC80FX SFC80FX series itachi Metals, Ltd.

Passing along the tradition from F to FX, a SFC80FX SFC80FX series From F to FX: Passing along the tradition Since the first of our SFC80 series, SAM brand highperformance mass flow controllers have been carrying forward a tradition. We use a waveform diaphragm made of a Ni-Co alloy (YET 0), developed by itachi Metals, which also proves that we are a manufacturer of high class metal materials. By employing this excellent diaphragm in the flow rate control valve, the key component in a mass flow controller, we incorporate a simple valve design that does not use any sliding sections and reduces the occurrence of particulate contamination. With a high corrosion resistance and stable control performance, we leave the competition behind and our customers satisfied. Diaphragm valve Our flow rate sensor, another key component in mass flow controllers, employs a coil type thermal sensor based on technology we have been accumulating for half a century, and it is extremely reliable. In the SFC80F series, thanks to the latest digital control technology, we have developed a dual-range mass flow controller, and a hybrid mass flow controller in which digital control technology reaches its peak. Our reputation is solid because our customers feel we offer an incomparable product. Gas inlet Q Coil By inheriting the full tradition of the SAM brand, the SFC80FX/SFC80FX series are our most advanced models. qs Bypass qs Coil Sensor tube Basic design of the sensor Gas outlet Circuit Less overshoot igh speed response: 0 to 00%;.0 sec. max. 0 to 0%;. sec. max. Guaranteed precision when actually measuring gas Valve actuator Uses a layered-piezoelectric element Sensor Larger diameter that doesn't clog easily Ni-free sensor (standard) Ni sensor for CIF, F Metal diaphragm Waveform Ni-Co alloy diaphragm (A proprietary development of itachi Metal) Extremely corrosion-proof with stable control No sliding surfaces and less creation of particles ousing material SUS6L (standard) Valve orifice Simple flow route Surface finish Our unique, special electro-polishing

bold advancement to the next generation. A bold advancement into the next generation, from G to FX Conceptual diagram of the MG/MR (multi-gas/multi-range) mass flow controller MFC MFC MFC MFC MFC MFC Ar O C SF6 Si N MFC MFC MFC MFC MFC MFC CF P CF6 NF SiF CO While inheriting the tradition of our earlier mass flow controllers, the SFC80FX/SFC80FX series is a bold advance into the next generation. The major element of innovation in this new series is the combination of many new technologies derived from the development of the G series all-in-one mass flow controller, in a new, next generation mass flow controller. One core technology that has been fed back from this development is the MG/MR (multi-gas/multi-range) function. In conventional mass flow controllers, one controller could only handle one type of gas and one full scale flow rate range. This means that customers needed to have another mass flow controller for each different system, and for each different process recipe. Since the FX series flow rate controller is equipped with the MG/MR function, and by preparing up to recipes (full scale ranges of SCCM to 0 SLM) to match the intended flow range, you can change the gas type and flow rate to match the actual gas you want to handle. When connected to a personal computer, the metering conditions can be changed instantly (See page 6). itachi Metals actual gas flow rate accuracy guarantee system backs up this MG/MR function. A conventional mass flow controller only guarantees the flow rate precision with N gas. To get the flow rate conditions for your actual gas using a conventional MFC, a conversion factor must be used as a coefficient to convert the flow rate. Abbreviation MG/MR FR-0 FR-0 FR-0 FR-0 FR-0 FR-06 FR-07 FR-08 FR-09 FR-0 FR- FR- FR- FR- Standard full-scale flow rate range (N equivalent) Flow range SCCM 6 SCCM 7 SCCM 88 SCCM 97 SCCM 70 SCCM 09 SCCM 979 SCCM 807 SCCM 707 SCCM 0800 SCCM 0000 SCCM 000000 SCCM 0000000 SCCM The reference values for these coefficients have been based of a variety of values, including calculated values, actually measured values, and empirical values. And, these were merely guidelines or reference values with some gas types. Although the MG/MR function is included, if the gas data deviates from the characteristics of the actual gas, the mass flow controller cannot perform as its designed level With the FX series mass flow controller, in addition to the flow rate reference for N gas (that ensures conformance with the national standard using the conventional gravimetric method), we installed full scale actual gas metering and exhaust gas processing facilities at our factory. Using these facilities, measurement is made for each type of gas at each full-scale range, and record the data. This is then used as actual gas data. The advancements in the FX series are not limited to the features above. The PI (Pressure Insensitive) function improves the controller's ability to tolerate variations in the primary pressure. This function improves durability and is currently highly desired in mass flow controllers. The G series was developed from the G series as a mass flow controller containing a PI pressure sensor. The FX series inherited the PI technology of the G series. Although the FX series models do not have a pressure sensor, they employ a sensor method and housing that can be used with the new PI technology. So, even though the FX series is not as advanced as the G series with its full scale PI function, they have greater PI performance by design, when compared with the existing F series. N gas reference flow rate Actual gas flow rate measurement facility

SFC80FX / SFC80FX series For both the." and."igs MG/MR Mass Flow Controllers Dimensions FLOW Zero calibration Alarm LED FLOW Alarm LED Zero calibration Digital interface connector RJ- x 7. D-subminiature 9-pin 9 70.8.6 Digital interface connector RJ- x D-subminiature 9-pin 6.9 00.6 8..6... 7.7 0.8 80 70 8 7 8 7 8 7 W-seal 7 7 67 79.8. 0 80FX-UG-L 0 9 -φ.6 xm, mm deep 80 70 8 7 8 7 8 7 W-seal 9 -φ. 7 7 67 0.6 0 0 80FX-SUG-L.8 8.6 xm, mm deep Operation pressure * Temperature Accuracy Standard full scale flow rate (N equivalent) Function Valve operation Flow rate control range Proof pressure Operation Accuracy guaranteed eating temperature when not powered umidity Installation position N gas Linearity Actual gas Repeatability 0% Flow rate sensor guaranteed zero point deviation range Zero point Temperature dependence Span 0% 000% Response Time 0% 0% External leakage standard Flow rate setting signal Flow rate output signal Material of gas wetted surface Item Specifications * Inlet pressure Outlet pressure N gas Actual gas Required power 0% 0% ousing, flange, valve seat Diaphragm Flow sensor Seal * Surface finish of components that contact the gas Fitting * SFC80FX SFC80FX SCCM,00SCCM SFC8FX SFC8FX SFC8FX SFC8FX SFC8FX SFC8FX SLM 0SLM 0SLM Multi-gas/multi-range Normally closed / normally open 00% F.S. 0.00. MPaG 0.0. MPaG 0.0. MPaG 7.. PSIG.. PSIG 9.0. PSIG Vacuum to ambient pressure.0 MPaG) PSIG) 0 6 maximum 80%R (non condensing) orizontal, Vertical orizontal, Vertical (option) ± 0.% S.P. + 0.% F.S. ±0.% F.S. ±.% S.P. + 0.% F.S.) ±0.% F.S. ±0.% F.S. ±.0% F.S. ±0.% S.P. + 0.0% F.S.) ±0.06% F.S. ±0.% F.S. / year, max. ±0.0% F.S. / ±0.0% S.P. / Max..0 sec. to reach ±% S.P of the set value. Max.. sec. to reach ±0.% S.P of the set value. Max. x0 - Pam /s (e) 0. to VDCabsolute rating: Max. ± VDC 0 to VDC (maximum output: ± VDC) + VDC ±%, 0 ma max - VDC ±%, 0 ma max SUS6L YET0 (Ni-Co alloy) SUS6L Ni SUS6L Specially electro-polished (standard) W seal, C seal, G seal, / MJ (UJR) male *: The specifications above are guaranteed values when the MFC was measured by itself in standard conditions. The MFC may not meet the specifications above, depending on the measurement conditions. *: The SFC7*FX/SFC7*FX are also available for use with minute pressure differences. Please inquire separately for the specifications of our minute pressure difference models. *: A model using a rubber seal is also available. Please inquire separately about the rubber seal specifications. *: An G seal is only available on the SFC**FX series

SFC80FX-D / SFC80FX-D series DeviceNet TM communication type For both the." and."igs MG/MR Mass Flow Controllers Dimensions FLOW Zero calibration Zero calibration FLOW Service connector (RJ-) (RS-C) 6.7 9 6 DeviceNet TM Connector Male Micro Connector Service connector (RJ-) (RS-C) DeviceNet TM Connector Male Micro Connector 7. 6 8.. 7 (6) 6. 00.6 80 70 8 7 8 7 8 7 W-seal 7 7 67. 79.8 -φ.6 0 80FX-UG-D 0 9 xm, mm deep 80 70 8 7 8 7 8 7 W-seal 7 7 67 9 -φ. 0.8 8.6 0.6 0 xm, mm deep 80FX-SUG-D Item Standard full scale flow rate (N equivalent) Function Valve operation Flow rate control range Operation pressure Inlet pressure * Outlet pressure Proof pressure Operation Temperature Accuracy guaranteed eating temperature when not powered umidity Installation position N gas 0% Accuracy Actual gas 0% N gas Linearity Actual gas Repeatability 0% Flow rate sensor guaranteed zero point deviation range Zero point Temperature dependence Span 0% 000% Response Time 0% 0% External leakage standard Flow rate setting signal Flow rate output signal Required power ousing, flange, valve seat Material of gas Diaphragm wetted surface Flow sensor Seal * Surface finish of components that contact the gas Fitting * SFC80FX-D SFC80FX-D SCCM,00SCCM SFC8FX-D SFC8FX-D Specifications * SFC8FX-D SFC8FX-D SFC8FX-D SFC8FX-D SLM 0SLM 0SLM Multi-gas/multi-range Normally closed / normally open 00% F.S. 0.00. MPa G 0.0. MPa G 0.0. MPa G 7.. PSI G.. PSI G 9.0. PSI G Vacuum to ambient pressure.0 MPaG PSIG 0 6 maximum 80%R (non condensing) orizontal, Vertical orizontal, Vertical (option) ±0.% S.P. + 0.% F.S. ±0.% F.S. ±.% S.P. + 0.% F.S. ±0.% F.S. ±0.% F.S. ±.0% F.S. ± 0.% S.P. + 0.0% F.S. ±0.06% F.S. ±0.% F.S. / year, max. ±0.0% F.S. / ±0.0% S.P. / Max..0 sec. to reach ±% S.P of the set value. Max.. sec. to reach ±0.% S.P of the set value. Max. x0 - Pam /s (e) DeviceNet TM communication * + VDC, 0. A max SUS6L YET0 (Ni-Co alloy) SUS6L Ni SUS6L Specially electro-polished (standard) W seal, C seal, G seal, / MJ (UJR) male *: The specifications above are guaranteed values when the MFC was measured by itself in standard conditions. The MFC may not meet the specifications above, depending on the measurement conditions. *: The SFC7*FX/SFC7*FX are also available for use with minute pressure differences. Please inquire separately for the specifications of our minute pressure difference models. *: For information about DeviceNet TM communication, see page 6. *: A model using a rubber seal is also available. Please inquire separately about the rubber seal specifications. *: An G seal is only available on the SFC**FX series

ow to use the MG/MR conversion program Gas type and flow rate can be converting using an MG/MR conversion program. Connect the mass flow controller to a personal computer using a digital communication cable, and use our proprietary program. One can convert the data easily with a simple GUI interface program. Following the program instructions, first select the gas type, and then flow rate units. A flow rate range will appear, and it can be changed. Enter a flow rate value and the setting is complete. Users can change the gas type and flow rate. <MG/MR conversion program> Select the correction amount data according to the gas type and flow rate you want to control RSC RS8 Before conversion Simple operation to set the gas type and flow rate. Select a gas type OST PC N 00SCCM After conversion The flow rate range is displayed (user settable). Enter a flow rate SF6 00SCCM O 00SCCM Br 00SCCM * For details about the operation, see the instruction manual A screen that shows the program is converting. Models compatible with the DeviceNet TM communication system About DeviceNet TM This is a field network recognized world wide, and it is approved as a standard sensor bus by the SEMI. Field devices can be connected using serial communication in place of an I/O connection, allowing transfer of a large volume of data effectively. The DeviceNet TM specifications are administrated by the ODVA (Open DeviceNet Vendor Association, Inc.) a non-profit body established to promote the spread of this system world-wide. What are the advantages of employing DeviceNet TM ) By using serial communication from an I/O connection, one does not need an AD / DA / O board which can decrease configuration and set up costs. ) Only network cables are needed and this reduces cabling costs, which decreses required man-hours, shortening engineering periods, and avoids problems from incorrect wiring. ) DeviceNet TM employs a CAN (Controller Area Network) as a communication controller, and you can use a variety of CAN error detection functions. ) The DeviceNet TM specifications are administrated by the ODVA, and have been normalized as international standards by IEC and SEMI. With this normalization, they are completely open, and lots of control devices are available from multiple venders. You can choose the optimum device for your application. ) The power for DeviceNet TM is only + VDC. You do not need to supply ± VDC for the mass flow controller. PLC Master PLC bus line DeviceNet TM cable +VDC POWER Distribution box

Communication connector pin assignment Analog interface connector (D-Sub 9-pin) Connector used : D-Subminiature, 9-pin connector (M screw) Compatible plug : 7JE-090-0 (D8B) (made by DDK) or equivalent ) Connector model : L type Pin number 6 7 8 9 Function Valve open/close input (+ VDC = Fully open; - VDC = Fully closed) Output (0 to VDC) + VDC COM (± VDC) - VDC Input (0. to VDC) COM (output) COM (Input) Valve valtage (0 to VDC) Digital interface connector Connector used : 8-66 (made by Molex) (RJ- x connectors) Pin number 6 Note : Rxd, Txd: RSC Input and output Note : RS-, RS+: RS80 Input and output Pin number RSC Rxd Txd Signal name COM (Siginal) No Connection N.C. N.C. RS8 RS- RS+ ) Connector model: Q type Function Valve Full open (operate by connecting to COM) Out put (0 to VDC) + VDC COM (± VDC) - VDC Input (0. to VDC) COM (output) COM (Input) Valve Full-close (operate by connecting to COM) 6 DeviceNet TM connector Connector used : DeviceNet TM Male Micro Connector (CM0-8DRP(D) made by DDK, or equivalent) Signal name Drain V+ V- CAN_ CAN_L Pin number 6 7 8 9 CAN_ V- CAN_L Drain V+ Additional functions Function name Description Setting and reading methods Alarm function Flow sensor zero reset function Lamp response function Flow control valve voltage monitor output function Flow control valve fully open / close function See the item for the alarm function Reset the flow sensor zero Reset the flow rate using a specified time for the step flow rate setting. Set the flow control valve opening (0 to VDC) Open and close the flow control valve completely By command By command or when the switch on the top is pressed By command By command or analog voltage output (only L type) By command, ± VDC, or contact point connection Alarm function Alarm cause Alarm LED display Alarm output condition Normal operation Flow rate setting does not the match flow rate output Abnormal ± VDC power supply EEPROM access error Digital communication error Change in flow rate control status (Change from the preset status) Flow rate setting changed Flow rate output changed Flow control valve open level changed Abnormal zero point correction value for the flow sensor Green LED blinks at z Red LED lights Turns off Red LED lights Red LED goes on Red LED blinks at z No alarm The mis-match between the flow rate setting and the flow rate output is 0% or more of the full scale and has continued for 0 seconds or longer The ± VDC power supply is outside the range of ± VDC to ±7 VDC, and has been for 0. seconds or longer. Abnormal value in the EEPROM data. Did not receive a normal digital command The change in the preset value was 0% or more of the full scale and continued for 0 seconds or longer. Or, the cumulative value of the zero point correction amount for the flow sensor is more than ±0% of full scale

Precautions to ensure safe use In order to use our products safely, make sure to read the relevant instruction manuals before use. SFC80FX/SFC80FX series ordering information Controller or meter SFC SFC FMT Size Temperature Pressure Flow range Series Optional code Fitting Connector Gas-contact Communication Protocol Flow sensor surface finish method material UG L B L N V * / MJ (UJR) male UG. W AG. C G **." G seal (itachi IGS seal) SUG ***." W seal SAG ***." C seal L Q T *** D Blank Special electro-polished K Machine processed finish Blank RSC or DeviceNet TM B RS8 Blank L Blank Note: * Can measure a mm gap between the faces of a / MJ (UJR) male. N ** Only the SFC80FX series can be used with a G fitting *** Only the SFC80FX series can be used with SUG, SAG fittings and a T connector Seal Operation 8 FX M C Mass flow controller Mass flow meter." size." size 6 Normal temperature type igh temperature type (80 ) Ultra-high temperature type (0 ) 8 Normal pressure type 7 Low inlet pressure type 0,00 SCCM (FR-0) SLM (FR-) 0 SLM (FR-) 0 SLM (FR-) FX Multi gas, multi range, digital M R D-sub 9-pin (top mount), valve fully open / fully closed signal, ±VDC type D-sub9 (top mount), valve fully open / fully closed signal, COM connection type D-sub 9-pin (upstream side), digital output type DeviceNet TM SAM protocol or DeviceNet TM protocol Ni free Ni sensor Metal seal Rubber seal Blank C O Mass flow meter Normally closed Normally open Sales agent: itachi Metals, Ltd. http://www.hitachi-metals.co.jp Fine flow Business Unit piping components Division : 97-8 Ishikawa-cho, achioji-shi, Tokyo 9-00 Japan TEL: +8--6-87 FAX: +8--660-00 SAM FANTAS YET 0 The contents of this pamphlet are correct as of August 0. The specification, appearance, etc. of products listed in this pamphlet may be changed without prior notice. Due to printing reasons, the product colors in this pamphlet may be different from the actual product colors. This pamphlet is copyright 0 by itachi Metals Ltd., all rights reserved. Duplication of any part of the contents without prior written approval is strictly prohibited. If you have questions about anything described in this pamphlet, please contact the address shown on the left. DeviceNet TM is a registered trademark of ODVA. We are not liable for and do not accept responsibility for any loss, direct or indirect, caused by incorrect use, careless handling, force majeure, war, terrorism, fire, pollution, use in unapproved environments, salt damage, or any natural disasters (such as wind or flood damage, earthquakes or lightning), or for any consequential damage. The address and contact details in this pamphlet are correct as of August 0. Since these details may change in the future, and if you cannot contact us by telephone or fax, please contact us as follows. itachi Metals Ltd., Communication Bureau: Tel. 8-76-076, Fax. 8-76-8 Email: hmcc@hitachi-metals.co.jp Pamphlet number: L-K-B Created August, 0 (T-FT)