[You may download this article at: https://fluidsys.org/downloads/ ]

Similar documents
Hydraulics. Hydraulic Pressure Control

Lecture 19 PRESSURE-CONTROL VALVES [CONTINUED]

Basic Pneumatics. Module 8: Pressure control valves. Academic Services PREPARED BY. April 2012

Contents. Catalog HY /US Load and Motor Control Valves SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Introduction. Part one: Identify the Hydraulic Trainer Components

Basic Pneumatics. Module 7: Time delay valve and sequence control systems. Academic Services PREPARED BY. January 2013

Basic Pneumatics. Module 9: Time delay valve. Academic Services PREPARED BY. April 2012

Priority (Swing) Motors Data and Specifications

Leak-Free Load-Control Valve SAE ½ psi flange

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES. This work covers part of outcome 2 of the Edexcel standard module:

Basic Hydraulics. Module 4: Flow Control Valves & Pressure Relief Valves. Academic Services PREPARED BY. January 2012

ATM 322 Basic Pneumatics H.W.6 Modules 5 7

ANTI SHOCK RELIEF VALVE

Technical Tip. LoadAdaptive TM Counterbalance Valves. Introduction. Overview. August 2015

Technical Tip. LoadAdaptive TM Counterbalance Valves. Introduction. Overview. November2015

Lesson 6: Flow Control Valves

2015 Fluid Power Innovation & Research Conference (FPIRC 15) Empirical Method for Determining CB Efficiency and Stability

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

INDIAN INSTITUTE OF TECHNOLOGY KHARAGPUR NPTEL ONLINE CERTIFICATION COURSE. On Industrial Automation and Control

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm)

Xpress L90LS Directional Control Valve. Catalog HY /UK December, 2001

Pressure reducing valve, direct operated, type DR 5 DP Huade América 1

Tech Tips. Service Call: Adjustable Hydraulic Valves Flow controls Pressure controls Sequence valves Holding valves

Introduction to Pneumatics

Directional Control valves

Unit 24: Applications of Pneumatics and Hydraulics

(Refer Slide Time: 0:26)

MWEA MAINTENANCE SEMINAR SPECIALTY VALVES POWER GLOBES

Hydraulic Reliability & Preventive Maintenance Report

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

Directional Controls

Leak free Pipe Rupture Valve for Excavators

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm)

Chapter 10: Bidirectional Flow Controls

Bulletin 2537-M2/USA Service Bulletin Series PRM

BACK PRESSURE / SUSTAINING

BRAKE SYSTEM BLEEDING

Explanations hydraulic valves TECHNICAL EXPLANATIONS HYDRAULIC VALVES. Contents. 1. Foreword. 2. Characteristic Values

Full Range Pressure Compensating Variable Flow Control

Leak-Free Load-Control Valve, Size 20

Directional Controls

LINDGREN-PITMAN, INC. LS-3 / LS-4 Line Setter

BACK PRESSURE / SUSTAINING

PRESSURE SEQUENCE VALVE TYPE UZK

P r o d u c t R a n g e Data sheet: P

Time-Delay Electropneumatic Applications

Pressure reducing valve, pilot operated

Pilots Specifications

SystemStak Valves. ISO4401 Size 02

WORKHOLDING APPLICATION BOOKLET

STAND ALONE SPREADER INSTALLATION INSTRUCTIONS AND OPERATOR S MANUAL

Directional Controls

LECTURE 20 FLOW CONTROL VAVLES SELF EVALUATION QUESTIONS AND ANSWERS

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

TRAINING SCHEDULE FLUID POWER TRAINING CUSTOM TRAINING PRODUCT TRAINING

Cover headline. Cover subheadline. Check Valves

MESP-202H INSTALLATION INSTRUCTIONS AND OWNER S MANUAL. HF and HF FEATURES VALVE FUNCTIONS ADJUSTMENTS SCHEMATICS

Bulletin 2533-M3/USA Service Bulletin. Series PR25MA, PR25P, PR25S, PR32P, PR32S. Effective: July 1, Pilot Operated Pressure Reducing Valves

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

Pilot Operated Check Valves Catalog Quick Reference

PTS1120TSJB PTS2120TSTSJB

IFP C175-* REMOTE CONTROL RELIEF VALVE

E SERIES. Specification. E Series. Relief and Flow Control Valves O M O M EIC-H Model No. Description

Hydraulic Punch Drivers

SINGLE VALVE WITH LOW-FLOW BYPASS

Experimental Investigation on Transient Response of Two Stage Pressure Relief Valve

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type

Circuit building blocks

Cartridge Valves Technical Information. Pilot operated check valves. Quick reference

Oil connector 3/8NPT. usable oil Air inlet pressure max. operating Air consumtion. oil capacity capacity min. max.

Controllers DR, DP, FR and DFR

Electrically Operated Pressure-Relief Cartridge, Size 10

Unit 24: Applications of Pneumatics and Hydraulics

TANK MATE INCLUDES: TOOLS REQUIRED: CONRADER VALVES 3/4 WRENCH **TUBING CUTTERS TEE PETCOCK TEE ASSEMBLY 8 FOOT NYLON TUBING

Pressure reducing valve, direct operated, sandwich plate, type ZDR6D...40B/(New Series)

Proportional Valve Group PVG 32 minibooster

The University of Jordan. School of Engineering. Mechatronics Engineering Department

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

MADILL 24.7" 365 TILT SET-UP PROCEDURE WITH REXROTH VALVE ON MACHINE

Inverse Proportional Pressure-Relief Cartridge, Size 10

All information correct as of 25 th September 2013 and subject to change without notice. 6 inch HURRICANE modular dredge equipment operations manual.

HANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to:

FUNDAMENTAL PRINCIPLES OF SELF-OPERATED PRESSURE REDUCING REGULATORS. John R. Anderson Emerson Process Management Fluid Controls Institute

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

Proper Pump Installation Practices

Waterous Relief Valve

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

SPC*01 (2-way) SPC03/06 (2-way) Size NG6 NG10 NG16 NG25 DIN A10 ISO 4401 NFPA D05 CETOP 5 P, A, B:

SPH 4C Unit 4 Hydraulics and Pneumatic Systems

Learning System for Automation and Communications. Hydraulics. Workbook Basic Level

Pressure reducing valve, pilot operated, Model 3DR

Key Features & Advantages of JEHA MK IV (5,000 PSI Hydraulic Test Stands)

Pressure reducing valve, direct operated

LV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE

FLOW CONTROL & AIR PILOT SWITCH VALVES

SC HYDRAULIC ENGINEERING CORPORATION

HANDBOOK. Squeeze Off Unit SOU 250. Please refer any queries to:

SERVICE INSTRUCTIONS P-A OR P-B ELECTRONIC PRESSURE COMPENSATOR, SERIES F1U CONTROLS

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Reset Volume Controller 2 Reversing Relay 3 Air Valve Actuator 4 Lower-of-Two-Pressures Relay 4 Diverting Relay 5 Higher-of-Two-Pressures Relay 5

Transcription:

Fluidsys Training Centre, angalore offers an extensive range of skill-based and industry-relevant courses in the field of Pneumatics and Hydraulics. For more details, please visit the website: https://fluidsys.org [You may download this article at: https://fluidsys.org/downloads/ ] Pressure Control Valves in Hydraulic Systems The article looks at the basics of pressure control valves for educational use and is presented here to refresh your memory. Hope you are able to recall the functions, circuits, and applications of pressure control valves. Pressure control valves are used in hydraulic systems for obtaining pressure-related control functions. The control tasks include reducing the pressure in some part of a hydraulic circuit, unloading of pumps, establishing the sequence movements of actuators, the counterbalancing of overrunning loads, and the braking of hydraulic motors while running on inertia. ccordingly, pressure control valves can be categorized into: (1) pressure reducing valves, (2) unloading valves, (3) sequence valves, (4) counterbalance valves, and (5) brake valves. It may be noted that a pressure relief valve is treated as a pressure regulating valve rather than a pressure control valve as its function in a hydraulic system is to modulate the supply pressure and limit the maximum operating pressure in the system. Symbolic Representation of a asic Pressure Control Valve Outlet Pilot line Inlet (a) Normally-closed valve (b) Normally-open valve Pressure Reducing Valve T The primary role of the pressure reducing valve in a hydraulic system is to limit the pressure in some part of the system to a value lower than that required for the rest of the system. The 1

reduced pressure can be set by using a control spring. The valve consists of an inlet port, an outlet port, a spring-loaded spool, and a pressure adjusting screw. The valve is provided with an internal control passage to evaluate the outlet pressure (at port ). When the outlet pressure remains below the valve setting, the fluid flows freely from the inlet to the outlet (that is, from to ). When the pressure at the outlet exceeds the valve setting, the spool shifts to block the outlet port, thus maintaining a reduced pressure in the regulated line. For example, an excess force (pressure) applied to the clamping operation by the cylinder 2 may damage the workpiece being clamped. In such a situation, a pressure reducing valve can be used to limit only the clamping pressure. You may observe the pressure values in parts of the circuit below. Unloading Valve T T n unloading valve consists of an inlet port, a tank port T, a pilot port, and a springbiased spool. The unloading pressure can be varied by adjusting the spring tension. The pilot 2

port is provided to accept the external pressure signal, which acts on one end of the springbiased valve spool. In the normal position, the valve remains closed by the spring force. When a sufficient signal is applied to the pilot spool, the spool shifts, and the pump delivery is diverted to the reservoir through the tank port (that is, from to T) at a low-pressure. The primary function of the unloading valve is to regulate the pressure by bypassing the fluid to the system reservoir at a low energy level in response to the external pressure signal received from the load section of the system. Unloading valves can be used in accumulator circuits, hydraulic motor circuits, and two-pump hi-lo circuits. s for an example, consider a hydraulic system with a pump, a reservoir, a pressure relief valve, an unloading valve, and a cylinder. In contrast to the maximum pressure limiting control of the pressure relief valve, the unloading valve discharges the pump delivery back to the reservoir at a low-energy level. The use of this valve provides a way for the cost-effective operation of the system as the heat generation in the system is minimized. You may observe the circuit below for the unloading of the pump through the unloading valve, while the pilot signal, received from the load section, acts at the pilot port x. Sequence Valve sequence valve consists of an inlet port an outlet port, a spool and a spring. The valve remains closed by the spring force. The externally adjustable spring is provided to set the pressure to the required value. pilot passage x is provided in the valve to accept signals from the inlet to act on one side of the spool. When sufficient pilot pressure is applied, the spool moves against the spring force and opens the valve, thus allowing the flow through the valve. The valve is kept open until the pilot sensing pressure goes below the spring bias. They are available with built-in check valves each of that permits an unrestricted reverse flow. The spring 3

chamber in the sequence valve is drained externally to the system reservoir to negate the effects of back pressure. Drain Pressure sequence valves can be used to obtain sequential operations of work processes. For example, they can be used in a hydraulic system with a clamping cylinder and a drilling cylinder to get the sequence control of these cylinders. The two critical positions of the circuit are shown in the figure below. The first part of the circuit shows the condition when the 4/3-way valve is shifted to its left-hand side envelope. When the cylinder reaches the end of its forward stroke to clamp a workpiece, the pump pressure at the inlet of the sequence valve SV2 increases and hence the sequence valve (SV2) opens, allowing the drilling cylinder to move forward to control the movement of the drill unit. The second part of the circuit shows the condition when the 4/3-way valve is shifted to its right-hand side envelope. When the cylinder reaches the end of its return stroke, the pump pressure at the inlet of the sequence valve SV1 increases and hence the sequence valve (SV1) opens, allowing the cylinder to return to its home position. Counterbalance Valve The counterbalance valve is a normally-closed valve with an inlet port and an outlet port. It also consists of a spring-loaded spool. The externally adjustable spring is provided to set the 4

pressure. The counterbalance must be set at a little higher pressure than that required to retain the load. pilot passage is provided to accept a signal from the load side of the valve and the signal acts on one side of the spool. The flow path through the valve opens when the pressure at the pilot port increases beyond the pressure setting. When open, the valve discharges the fluid from the inlet port to the outlet port. The valve closes when the pressure drops below the setting of the spring. The main function of the counterbalance valve in a hydraulic circuit with a load-carrying actuator is to maintain the preset backpressure in the return line of the circuit, sufficient to balance the load held by the actuator. Vertically-mounted cylinders connected with heavy loads or hydraulic motors on winch drives are susceptible to the dangers associated with overrunning loads. Consider a hydraulic cylinder with a heavy load attached. The load forces the cylinder to move faster than the average speed of the cylinder when the associated directional control valve shifts its position to lower the load. Therefore, the actuator with the overrunning load needs some method to retard its downward movement to obtain a smooth operation. Using a counterbalance valve is a better way to control the overrunning load, as the valve dynamically counterbalances the potential free-fall of the connected load. It prevents the actuator from running ahead of the pump due to the load induced energy. 5

uthored by JOJI Parambath, Founder/Director, Fluidsys Training Centre, angalore Reference: JOJI PRMTH, Industrial Hydraulic Systems Theory and Practice, Universal Publishers, oca Raton, US, 2016. http://www.universal-publishers.com/book.php?method=isn&book=1627340580 Note: comprehensive account of the topic is given in the textbook on Industrial Hydraulic Systems-Theory and Practice by Joji Parambath. For more useful article and downloads, please visit: https://fluidsys.org/downloads/ Please contact Fluidsys Training Centre, angalore for training in the field of Pneumatics, Electro-pneumatics, Hydraulics, Electro-hydraulics, etc. email: info@fluidsys.in website: https://fluidsys.org 6