Similar documents
Space Pressurization: Concept and Practice ASHRAE Distinguished Lecture Series

This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer Committee

Results of Field Measurements and CONTAM Simulation. Building Science

COMPARISON OF DIFFERENTIAL PRESSURE SENSING TECHNOLOGIES IN HOSPITAL ISOLATION ROOMS AND OTHER CRITICAL ENVIRONMENT APPLICATIONS

Emerging Technologies in Room (Suite) Pressure Control, Performance Modeling and Design Practices

Sizing of extraction ventilation system and air leakage calculations for SR99 tunnel fire scenarios

2005 CERTIFICATE OF ACCEPTANCE (Part 1 of 3) MECH-1-A

HVAC Air Duct Leakage. Tech University 2013 Presented By: Mark Terzigni Project Manager Technical Services SMACNA

INTERPRETATION IC OF ANSI/ASHRAE STANDARD VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY

CTG Certification Protocol -- Version 3.0 SUMMARY

CX Mission Critical Facilities for Safety and Resiliency Select Agent BSL-3 Lab. Dave Guberud QCxP, CxA Rachel Rueckert P.E., QCxP, CxA, LEED AP

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

LOW PRESSURE EFFUSION OF GASES adapted by Luke Hanley and Mike Trenary

VAV SYSTEM INDOOR AIR QUALITY CONSIDERATIONS FOR OFFICE SPACES

Technical vs. Process Commissioning Final Exam: Functional Performance Testing

TESTING OF BELIMO PRESSURE INDEPENDENT CHARACTERIZED CONTROL VALVES

Transient Analyses In Relief Systems

HAP e-help. Obtaining Consistent Results Using HAP and the ASHRAE 62MZ Ventilation Rate Procedure Spreadsheet. Introduction

Outside Air Nonresidential HVAC Stakeholder Meeting #2 California Statewide Utility Codes and Standards Program

The Advancement of Pressure Independent Technology

This portion of the piping tutorial covers control valve sizing, control valves, and the use of nodes.

Facility management and equipment. Institut Pasteur du Maroc

Hydronic Systems Balance

How to Ensure AMCA-Certified Products Get Installed. An AMCA International White Paper. September, 2015

The Stack Effect. Mat Ansari PE

Practical Guide. By Steven T. Taylor, P.E., Member ASHRAE

Regulatory Basics for Facility Design (WHO GMP): Current GMP Requirements

IC Sentinel Applications Guide for Healthcare Environmental Air Quality Monitoring

Kansas State University Fume Hood Operation

Integrating Aeration Blowers with Most-Open-Valve

SECTION TESTING ADJUSTING AND BALANCING FOR HVAC

1. A tendency to roll or heel when turning (a known and typically constant disturbance) 2. Motion induced by surface waves of certain frequencies.

Lab 1c Isentropic Blow-down Process and Discharge Coefficient

ASSESSMENT OF BIOAEROSOL REDUCTION METHODS IN STEM CELL TRANSPLANT UNITS AT A UNIVERSITY HOSPITAL

Modeling a Pressure Safety Valve

VENTILATION EFFICIENCIES OF A DESK-EDGE-MOUNTED TASK VENTILATION SYSTEM

GOOD MANUFACTURING PRACTICES FOR HEATING, VENTILATION AND AIR-CONDITIONING SYSTEMS FOR NON-STERILE PHARMACEUTICAL DOSAGE FORMS: PART 2

APPLICATION OF AIRTIGHTNESS TO HEALTHCARE BUILDINGS

B. Diagnostic Equipment Information 01 Number of Manometers Used to Measure Home Pressurization Manometer Make. Manometer Serial Number

Balancing HVAC Hydronic Systems Part 3: Flow Measurement Valves

MEASURING AIR FLOW. Ventilation (Outside Air) Calculations. Derive % of OA as part of total air flow using air temperatures:

485 Annubar Primary Flow Element Installation Effects

Measuring range Δp (span = 100%) Pa

Statesville, NC. Results of AM ASHRAE 110 Laboratory Fume Hood Performance Evaluations Venturi Hood

4 Testing Agency Guide. 4.1 U.S. Army Corps of Engineers (USACE) Standard for Air Leakage

Control of Nuclear Gloveboxes and Enclosures Using the No- Moving-Part Vortex Amplifier (VXA)

Validation of a Neutral Pressure Isolation Room

B. Diagnostic Equipment Information 01 Number of Manometers Used to Measure Home Pressurization Manometer Make. Manometer Serial Number

ASTATT10 Carry out air tightness testing on large and complex, high rise and phased hand over zonal buildings

Zonal Pressurization Diagnostics (ZPD)

MANAGEMENT PROCEDURE FOR LABORATORY VENTILATION

The routine maintenance and inspection of local exhaust ventilation (LEV)

Pressure Independent Control Series

Vortex flowmeters. Product family introduction Principle of operation Product review Applications Key product features

Single- or Two-Stage Compression

CROSS CONTAMINATION OF IN-SUITE MURB VENTILATION SYSTEMS

TWO PHASE FLOW METER UTILIZING A SLOTTED PLATE. Acadiana Flow Measurement Society

For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY

CSC-2000 SERIES. Reset Volume Controllers MADE IN U.S.A. DESCRIPTION MODELS SPECIFICATIONS ORDERING

AUTOMATIC FLOW CARTRIDGES. Competition Analysis Not All Automatics Are Created Equal

Process Simulator Evaluates Blower and Valve Control Strategies for WWTP Aeration

Facility design for containment. Gordon Farquharson, July 2016

MANUAL DIRECT PURGE OPTION. UNION Instruments GmbH CWD2005 PLUS. General information, safety standards and regulations for direct purge option

Pumping Systems for Landscaping Pumps, Controls and Accessories. Mark Snyder, PE

Applied Fluid Mechanics

CORESTA RECOMMENDED METHOD N 6

ACCURACY, PERFORMANCE, AND HANDLING OF OIL-FILLED DIGIQUARTZ PRESSURE INSTRUMENTATION

STANDARD FOR CONTROL VALVE SEAT LEAKAGE

Gerald D. Anderson. Education Technical Specialist

1.0 PURPOSE 2.0 SCOPE 3.0 DEFINITIONS. ANSI: American National Standards Institute. CCC: Chemical Control Centre

Gas Check. Short testing time, with automatic start-up if no leakage was detected from previous operation.

Characterizers for control loops

EDUCATION DEPARTMENT ACCU-TEST

ARCA Guidance Note. Guidance on Air Management in Asbestos Enclosures

NUMERICAL INVESTIGATION OF THE FLOW BEHAVIOUR IN A MODERN TRAFFIC TUNNEL IN CASE OF FIRE INCIDENT

CHEMICAL ENGINEERING LABORATORY CHEG 239W. Control of a Steam-Heated Mixing Tank with a Pneumatic Process Controller

JetVent SAFE, AUTOMATIC PRESSURIZED CONTAINMENT.

HVAC Considerations for Gaseous Decontamination of Laboratory Spaces using Hydrogen Peroxide Vapor

REQUIREMENTS AND HAND-OVER DOCUMENTATION FOR ENERGY-OPTIMAL DEMAND-CONTROLLED VENTILATION

Quick Reference Technical Data

Getting the Most From Your Diagnostic Equipment

Two-port valves, male threaded, PN25

Airtightness Testing in Large Buildings: NESEA 2016

CENTER PIVOT EVALUATION AND DESIGN

CSC-2000 SERIES. Reset Volume Controllers MADE IN U.S.A. DESCRIPTION MODELS SPECIFICATIONS ORDERING

Constant Pressure Inlet (CCN) Operator Manual

PLEA th Conference, Opportunities, Limits & Needs Towards an environmentally responsible architecture Lima, Perú 7-9 November 2012

Using SolidWorks & CFD to Create The Next Generation Airlocks

International Journal of Technical Research and Applications e-issn: , Volume 4, Issue 3 (May-June, 2016), PP.

Application of Double Vs Tandem Dry gas seal Advantages.

The process of measuring air

IH Report: SUFMO 08/09-CC21 1/27/2009 Stanford University Gas Cabinet Installation and Performance Criteria

Field Evaluation of ASTM E in Relation to Control Room Habitability Testing and Boundary Maintenance in Nuclear Power Plants.

Annex 8. Guidelines on heating, ventilation and air-conditioning systems for non-sterile pharmaceutical products. Background. Summary of main changes

SECTION TESTING, ADJUSTING, AND BALANCING CONTRACT NO SECTION TESTING, ADJUSTING, AND BALANCING

Draft. Equipment/Instrument

Lab # 03: Visualization of Shock Waves by using Schlieren Technique

MINIMUM SAFETY REGULATIONS

FILTER BYPASS CONTROL

COMPUTATIONAL FLOW MODEL OF WESTFALL'S LEADING TAB FLOW CONDITIONER AGM-09-R-08 Rev. B. By Kimbal A. Hall, PE

Transcription:

ASHRAE WILL ILL GIVE Y OU THE W ORLD This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer Committee Complete the Distinguished Lecturer Event Summary Critique CTTC needs your feedback to continue to improve the DL Program Distribute the DL Evaluation Form to all attendees Collect at the end of the meeting Compile the attendee rating on the Event Summary Critique Send the completed Event Summary Critique to your CTTC RVC and ASHRAE Headquarters Forms are available at: Forms are available at: www.ashrae.org/distinguishedlecturers Handout 1

B ECOME A FUTURE L EADER IN C HAPTER I N Y OUR C AREER YOU ARE NEEDED FOR: Membership Promotion Research Promotion Student Activities Chapter Technology Transfer Technical Committees IN ASHRAE WRITE RITE THE N EXT ASHRAE Members who attend their monthly chapter meetings become leaders and bring information and technology back to their job. Find your Place in ASHRAE! Visit www.ashrae.org Space Pressurization: Concept and Practice ASHRAE Distinguished Lecture Series Jim Coogan Siemens Building Technologies ASHRAE, Madison Chapter October 13, 2014 Handout 2

Agenda Introduction (concept, purpose, uses, scope) Physics: Infiltration and Containment Pressurization Methods Design Considerations Contaminant Control Perspective Summary Page 5 Room Pressurization A ventilation technology that controls migration of air contaminants by inducing drafts between spaces. Page 6 Handout 3

Room Pressurization Exhaust system removes air Supply system delivers less Room pressure is negative Infiltration makes up the difference Inward air flow contains pollutants Page 7 Introduction: Who uses it? Why? Biological and Chemical Laboratories prevent spread of airborne hazards Hospital Isolation Rooms protect patients and staff from germs Hospital Pharmacies facilitate sterile compounding Clean Manufacturing maintain product quality Page 8 Handout 4

Introduction: Who else uses it? Office towers control smoke in a fire; maintain exit path Any Building separate rest rooms from other spaces Restaurants keep kitchen smells out of the dining room Any Building keep unconditioned OA out of occupied spaces These uses are out of today s scope Page 9 How is success defined? Success is control of contaminants, not flows and pressure values Page 10 Handout 5

Infiltration and Containment Infiltration: mechanical process Velocity, Area, Pressure Infiltration Curves Importance of the Envelope Select Pressurization Level Page 11 Infiltration Process: Pressure, Velocity, Area, Flow Infiltration is a physical process Pressurization is an engineered result ASHRAE Handbook and Ventilation Manual from ACGIH model the process Page 12 Handout 6

Pressure vs. Velocity Simple approach is to model the velocity with a discharge coefficient ACGIH Industrial Ventilation: 7-3 v 0.6(4000) P ASHRAE Fundamentals Handbook presents more complex model, but the result is nearly the same Page 13 Infiltration Model for Pressurization Air velocity through gaps in envelope controls contaminants Velocity related to pressure by orifice flow What velocity do we need? Page 14 Handout 7

Reality of Room Air Motion Photograph of flow field (2D) in cross section of a room Particle Image Velocimetry Zhao L., ASHRAE Transactions, DA-07-044 Page 15 Velocity and Leakage Area Flow is velocity times area 2011 ASHRAE Handbook HVAC Applications, puts it together: 53-9 Q 2610A P Q = infiltration flow, cfm A = leakage area, sqft P = pressure across envelope, inwc Page 16 Handout 8

Infiltration Curve Pressure Difference vs. Flow 0.05 0.045 0.04 0.035 Pressure Difference 0.03 0.025 0.02 0.015 0.01 0.005 0 0 50 100 150 200 250 300 350 400 450 500 Infiltrating Air Flow Page 17 Infiltration Curves for Several Values of Leakage Area 0.05 0.045 0.04 0.035 Pressure Difference 0.03 0.025 0.02 0.015 0.01 0.005 Page 18 0 0 50 100 150 200 250 300 350 400 450 500 Infiltrating Air Flow Handout 9

Importance of the Envelope Leakage area is the main mechanical parameter in the pressurization system Like knowing the hx characteristics to apply a heating coil Like knowing the pipe diameter in a hydronic system Page 19 Select Pressurization Level Choose the flow offset Let it determine the pressure 0.035 0.03 Pressure Difference 0.025 0.02 0.015 0.01 0.005 0 0 50 100 150 200 250 Infiltrating Air Flow Page 20 Handout 10

Select Pressurization Level Choose the pressure Let it determine the flow offset 0.035 0.03 Pressure Difference 0.025 0.02 0.015 0.01 0.005 0 0 50 100 150 200 250 Infiltrating Air Flow Page 21 Select Pressurization Level Different ways to express the level of pressurization in terms of the pressure difference in terms of the infiltration flow Specify either the pressure or the flow offset, not both. Unless you are trying to specify the envelope Page 22 Handout 11

Pressurization and Migration Positive room pressure drives air and contaminants out Negative room pressure draws air and contaminants in Neutral room pressure exchanges air and contaminants both directions Page 23 Pressurization via HVAC Control Methods Explained and Compared Differential Flow Control Pressure Feedback Cascade Control Selecting a Pressurization Control Method Tightness of the Envelope Required Pressure Relationships Page 24 Handout 12

Control Methods Compared Three widely published methods Space pressure feedback Differential flow control Cascade control References: 2011 ASHRAE Handbook, HVAC Applications. Chapter 16 Laboratory Systems Siemens Building Technologies: Doc #125-2412. Room Pressurization Control Page 25 Control Methods Compared Some other ways Adaptive leakage model Trim valve References: W Sun, ASHRAE Transactions, NA-04-7-2. Quantitative Multistage Pressurizations in Controlled and Critical Environments L. Gartner and C. Kiley, Anthology of Biosafety 2005. Animal Room Design Issues in High Containment Page 26 Handout 13

Pressure Feedback Page 27 Pressure Feedback Measure pressure difference across room boundary Compare to selected setpoint Adjust supply flow or exhaust to maintain pressure difference Page 28 Handout 14

Differential Flow Control Page 29 Differential Flow Control Carefully control air supply to room Carefully control all exhaust from room Enforce a difference between them Select the size of difference to reliably contain pollutants Page 30 Handout 15

Cascade Control Page 31 Cascade Control Has other names: adaptive offset DP reset Measure pressure difference across room boundary Compare to selected setpoint Control supply and exhaust flow Enforce a difference between them Dynamically adjust flow difference to maintain the pressure setpoint Page 32 Handout 16

Selecting a Control Method Factors affecting selection Tightness of envelope Number of pressure levels needed Speed of disturbances and response Duct conditions for flow measurement Reference: 2011 ASHRAE Handbook HVAC Applications, Chapter 16 - Laboratory Systems, page 16.12 Page 33 Tightness of Envelope x 0.05 0.045 0.04 Pressure Difference 0.035 0.03 0.025 0.02 0.015 0.01 0.005 x o x o x 0 0 50 100 150 200 250 300 350 400 450 500 Infiltrating Air Flow Page 34 Handout 17

Number of Pressure Levels Relatively simple requirement 2-levels, OK for Differential Flow Tracking Page 35 Design Considerations: Effect of Air Flow Errors, In and Out Numerical illustration Nominal value Error Exhaust flow 1000 +/- 100 Supply flow 850 +/- 85 Transfer flow 150 +/- 185 Base flow control accuracy on desired infiltration ANSI Z9.5, Laboratory Ventilation Page 36 Handout 18

Select Pressurization Level 0.035 Based on leakage area Example: 150 cfm for ½ square foot 0.03 Pressure Difference 0.025 0.02 0.015 0.01 O 0.005 Page 37 0 0 50 100 150 200 250 Infiltrating Air Flow Select Accuracy Target 0.035 Based on need to control contaminants Not product spec s 0.03 Pressure Difference 0.025 0.02 0.015 0.01 0.005 x O x Page 38 0 0 50 100 150 200 250 Infiltrating Air Flow Handout 19

Derive Flow Control Accuracy Base flow control accuracy on desired infiltration Select allowable error on supply and exhaust for resulting transfer accuracy Nominal value Error Exhaust flow 1000 +/- 30 Supply flow 850 +/- 30 Transfer flow 150 +/- 45 Combine errors with square root of sum of squares Page 39 Derive Flow Control Accuracy For VAV: Consider accuracy across range of flow values Pressurization specs easier to meet at low flow Exhaust flow 1000 200 Supply flow 850 50 Nominal value Error +/- 30 +/- 30 +/- 30 +/- 30 Transfer flow 150 +/- 45 Page 40 Handout 20

Design Considerations: Which Terminal Does Pressurization Exhaust tracks supply Supply tracks exhaust Page 41 Agenda Introduction (concept, purpose, uses) Physics: Infiltration and Containment Pressurization Methods Design Considerations Contaminant Control Perspective Summary Page 42 Handout 21

Pressurization and Contaminant Control Success is control of contaminants, not flows and pressure values Theory: net inward flow blocks contaminants Research relates pressurization to contaminant control ASHRAE research relates pressure to clean room contamination: RP 1344 and RP 1431. W. Sun Bio lab experiments: Bennet, Applied Biosafety, 2005 Isolation room experiments: C. Hayden, et al., AOEH, 1998 Water model of isolation room: Tang, et al., PlosOne, 2013 Fact: contaminants cross boundaries for many reasons Page 43 Recent Research Projects Projects study movement of contaminants with: Open doors Moving doors Moving people ASHRAE RP 1344 and 1431 measured with particle source and counter Wei Sun, ASHRAE Research Report, RP 1344, Clean Room Pressurization Strategy Update Page 44 Handout 22

Recent Research Projects Projects study movement of contaminants with: Open doors Moving doors Moving people Hospital study used water tank model Tang JW, Nicolle A, Pantelic J, Klettner CA, Su R, et al. (2013) Different Types of Door-Opening Motions as Contributing Factors to Containment Failures in Hospital Isolation Rooms. PLoS ONE 8(6): e66663. doi:10.1371/journal.pone.0066663 Page 45 Pressurization and Contaminant Control Contaminant control can be very important or only slightly important Biosafety standards recognize range of hazards and range of responses Engineering and commissioning should match effort and solutions to needs Page 46 Handout 23

Levels of Contaminant Control Pressurization is one tool Physical barrier is also BSL 1 Laboratories should have doors BSL 2 Doors should be self-closing BSL 3 Series of two self-closing doors BSL 4 Airlock with air tight doors Page 47 Summary Space pressurization: tool for contamination control, not a magic shield Envelope leakage is main mechanical parameter Several HVAC control methods Differential flow control is used most often Choice usually driven by envelope Derive air flow accuracy spec from pressurization Align engineering effort with the hazard Page 48 Handout 24

Thank you! Questions? Jim Coogan, PE Jim.Coogan@Siemens.com Page 49 Handout 25