Service Manual DX70 Diaphragm Pump

Similar documents
DX200 Stainless Steel Diaphragm Pump

Service Manual. DX70 Pump Packages

DX :1. Stainless Steel Diaphragm Pump

Service Manual EN DX70. Pump Packages. Patent US R1.6 1/16

Service Manual DX70 Pump Packages

Binks MACH 1 PCX HVLP SPRAY GUN

MODELS & (OBS) REMOTE FLUID PRESSURE REGULATORS (30 OZ./MIN. & 100 OZ./MIN.)

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP

BINKS SG-2 PLUS TM ROTARY 2 QT. PRESSURE CUP

AIRLESS 75M SPRAY GUN 7500 PSI

Binks SV100 Conventional Suction Feed Spray Gun

BINKS SG-2 PLUS TM 2 QT. PRESSURE CUPS

BINKS SV100 HVLP PRESSURE FEED SPRAY GUN

Binks Model 21 (Brass Body) Automatic Spray Gun General Arrangement Diagram and Hook-Up. Side Port Control. Fluid. Cylinder Air Fluid.

Operation Manual Advanced-Conventional Pressure Feed Spraygun

MX412 12:1 Pump Systems for Air Assist & Airless Finishing

43P Airless Gun MODEL: DESCRIPTION

Instruction Manual. Standard Surge Eliminator. Standard X. Flushable X - X

BINKS WREN AIR BRUSHES MODELS A **, B, AND C ** OPERATING INSTRUCTIONS

BINKS SV100 HVLP GRAVITY FEED SPRAY GUN

EN MX432 32:1 Pump Systems for Air Assist & Airless Finishing Patent Pending

OWNER S TECHNICAL MANUAL

DK ton, Double-acting, Die-type Crimping Tool

Instruction Manual. Active Surge Eliminator X X

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

Back Pressure Regulator

Binks MACH 1PC HVLP SPRAY GUN FOR PLURAL COMPONENT CATALYST INJECTION

DIAPHRAGM PUMP MODEL PDM 1-175

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

SB-E ISS.01. Operation Manual: KB-522 & KB-522-SS Pressure Feed Cup E P ITW Finishing Systems and Products

MX :1 Pump Systems for Air Assist & Airless Finishing

MX412 12:1 PUMP SYSTEMS FOR AIR ASSIST & AIRLESS FINISHING

SB-E ISS.07. Operation Manual AGN-502 Automatic gun

7500 PSI Airless Spray Gun

Binks PNEUMATIC DIAPHRAGM PUMP DVP-GEMINI (RATIO 1:1)

3500 PSI Airless Spray Gun

Corrosion Control Equipment and Supplies

750 Cable Cutter INSTRUCTION MANUAL

Operation Manual HVLP & Trans-Tech Suction Feed Spraygun

INTENDED USE TECHNICAL SPECIFICATIONS

Fire-Ball 300 and 425 Grease Pumps

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

OPERATION / 3Z9305G 1:1 RATIO TRITON / Spray Packages / / / List of Models, page 2 / / / 100 psi (7 bar, 0.7 MPa) Maximum Working Pressure

183G (GALVANIZED) AND 183S (STAINLESS STEEL) 2-GALLON ASME TANKS CAPACITY UP TO 2.8 GALLONS

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

B84G - Excelon Plus Modular System General purpose filter/regulator

Installation, Operation, and Maintenance Manual

Tentec. Instruction Document. Mini Air Driven Pump Unit Model: HTT.627X Series. Part Identifier

Operating instructions Diaphragm pump MP-520. Article No Original operating instructions. T-Dok-397-EN-Rev.0web

BACK PRESSURE VALVE. Instructions Parts List J

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Pressure Dump Valve Service Kit for Series 2300 Units

RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

CS150 CAP STAPLER OWNER S MANUAL

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

AIR STAPLER. MODEL: CSG3KC Part No OPERATING & MAINTENANCE INSTRUCTIONS

HYDRAULIC PUNCH DRIVER 38456, 38520, 7306 / 7306SB, 7310 / 7310SB, 7506, 7606SB, 7610SB, 7625 / 7625Pg / 7625PgSB, 7646 / 7646Pg / 7646PgSB

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING

Dual Solenoid Gas Valve Installation

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

Pressure Relief Valve Instruction Manual

Operation Manual: MODEL BBR PRESSURE/SIPHON FEED HAND GUN Important:

Airmate TS1.5/6 Oil-less Air Compressor

HYDRAULIC INTENSIFIER Max. Pressure: See Intensifier Data Plate Weight: 16 Lbs. (7.26 kg)

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

GE Oil & Gas Model. Masoneilan* Air Lock-up Valve Instruction Manual. GE Data Classification : Public

Hydraulic Punch Drivers

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

INSTRUCTIONS-PARTS LIST

Operating instructions Diaphragm pump MP-400. Dok-236-GB-6bar.doc Rev. 0 Article No: keep for further use-

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

Instructions Parts List

Tire Inflation Cage Kit For servicing only single piece automotive, and most light truck tire/wheel assemblies

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

OPERATOR S MANUAL

INSTRUCTIONS PARTS LIST

HPB25 Hydraulic Paving Breaker

G7S Hand Pump Owner s Manual

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Solid Indicator (Non-mixer) Model CP-30SI

GATOR Battery-powered Pistol Grip Cable Cutters

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

AIR HAMMERS MODEL NO: CAT138/CAT139 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: / GC064

INSTRUCTIONS-PARTS LIST

Binks Model 7 SPRAY GUN (6100-XXXX-X)

3:1 High Ratio Oil Pump W. Extn. Kit

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Models: C62/63/64-A/D

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

book : t95575.fm Seite 1 Mittwoch, September 20, :10 AM. Avensys. Exposed Single Lever Mixer

System Pressure Manager Standard & System Pressure Manager Plus

3/8" Dr. Air Butterfly Impact Wrench

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN Original manual

GM-7000 Series CE Approved Gas Control Valve

BINKS MODEL 7 SPRAY GUN (6100-XXXX-X)

Type /2-Way Globe Valve 3/2-Wege-Geradsitzventil Vanne à siège droit 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Transcription:

Service Manual EN DX70 Diaphragm Pump 77-3200-R1.2 1/16

Product Description This Product is designed for use with: Diaphragm Pumps - DX70 Bare pump and packages Solvent and Water based Materials EN Suitable for use in hazardous area: Zone 1 & 2 Protection Level: II 2 G X IIB T4 (NB 0891) Manufacturer: Binks, Ringwood Road, Bournemouth, BH11 9LH. UK EU Declaration of Conformity We: Binks declare that the above product conforms with the Provisions of: Machinery Directive 2006/42/EC ATEX Directive 94/9/EC by complying with the following statutory documents and harmonized standards: EN ISO 12100: Safety of Machinery - General Principles for Design EN ISO 4413: Hydraulic Fluid Power - General Rules and safety requirements EN ISO 4414: Pneumatic Fluid Power - General Rules and safety requirements EN 12621: Machinery for the supply and circulation of coating materials under pressure - Safety requirements EN1127-1: Explosive atmospheres - Explosion prevention - Basic concepts EN 13463-1: Non electrical equipment for use in potentially explosive atmospheres - Basic methods and requirements EN 13463-5: Non electrical equipment for use in potentially explosive atmospheres - Protection by constructional safety Providing all conditions of safe use stated within the product manuals have been complied with and that the final equipment into which this product is installed has been re-assessed as required, in accordance with essential health and safety requirements of the above standards, directives and statutory instruments and also installed in accordance with any applicable local codes of practice. D Smith 1/4/13 (General Manager) 77-3200-R1.2 2/16

In this part sheet, the words WARNING, CAUTION and NOTE are used to emphasize important safety information as follows: EN WARNING Hazards or unsafe practices which could result in severe personal injury, death or substantial property damage. CAUTION Hazards or unsafe practices which could result in minor personal injury, product or property damage NOTE Important installation, operation or maintenance information. WARNING Read the following warnings before using this equipment. READ THE MANUAL. Before operating finishing equipmrnt, read and understand all safety, operation and maintenance information provided in the operation manual. AUTOMATIC EQUIPMENT. Automatic equipment may start suddenly without warning. WEAR SAFETY GLASSES. Failure to wear safety glasses with side shields could result in serious eye injury or blindness. DE-ENERGIZE, DE-PRESSURISE, DISCONNECT ANS LOCK OUT ALL POWER SOURCES DURING MAINTENANCE. Failure to de-energize, disconnect and lock out all power supplies before performing equipment maintenance could cause serious injury or death. PROJECTILE HAZARD. You may be injured by venting liquids or gased that are released under pressure, or flying debris. KNOW WHERE AND HOW TO SHUT OFF THE EQUIPMENT IN CASE OF AN EMERGENCY. NOISE LEVELS. The A-weighted sound level of pumping and spray equipment may exceed 85 db(a) depending on equipment settings. Actual noise levels are available on request. It is recommended that ear protection is worn at all times while equipment is in use. PRESSURE RELIEF PROCEDURE. Always follow the pressure relief procedure in the equipment instruction manual. INSPECT THE EQUIPMENT DAILY. Inspect the equipment for worn or broken parts on a daily basis. Do not operate the equipment if you are uncertain about its condition. EQUIPMENT MISUSE HAZARD. Equipment misuse can cause the equipment to rupture, malfunction or start unexpectedly and result in serious injury. HIGH PRESSURE CONSIDERATION. High pressure can cause serious injury. Relieve all pressure before servicing. Spray from the gun, hose leaks or ruptured components can inject fluid into your body and cause extremely serious injury. STATIC CHARGE. Fluid may develop a static charge that must be dissipated through proper grounding of the equipment, objects to be sprayed and alll other electrically conductive objects in the dispensing area. Improper grounding or sparks can cause a hazardous condition and result in fire, explosion or elecrtic shock and other serious injury. OPERATOR TRANING. All personnel must be trained before operating finishing equipment. PACEMAKER WARNING. You are in the presence of magnetic fields which may interfere with the operation of certain pacemakers. KEEP EQUIPMENT GUARDS IN PLACE. Do not operate the equipment if the safety devices have been removed. NEVER MODIFY THE EQUIPMENT. Do not modify the equipment unless the manufacturer provides written approval. PROP 65 WARNING. WARNING:This product contains chemicals known to the state of California to cause cancer and birth defects or other reproductive harm. PINCH POINT HAZARD. Moving parts can crush and cut. Pinch points are any areas where ther are moving parts. IT IS THE RESPONSIBILITY OF THE EMPLOYER TO PROVIDE THIS INFORMATION TO THE OPERATOR OF THE EQUIPMENT. 77-3200-R1.2 3/16

Specification EN Ratio: Maximum air inlet pressure: Maximum fluid pressure: Displacement per cycle: Output @ 60 cycles / min: Maximum Recommended Continuous Cycle Rate (cycles / min): 1:1 7 Bar [100 PSI] 7 Bar [100 PSI] 0.07 Litres [0.018 US Gall] 4.2 Litres/min [1.1 US Gall/min] 10 Maximum Recommended Intermittent Cycle Rate (cycles / min): 30 A Fluid inlet connection: 3/8 Universal (BSPP/NPSM) Male or Female B Fluid outlet connection: 3/8 Universal (BSPP/NPSM) Male or Female C Air inlet connection: 1/4 Universal (BSPP/ NPSM) Female D Fluid regulator pilot connection: Ø4mm [Ø5/32"] Maximum dry/wet Lift: 6.6m [21.8 feet] Air volume / cycle @ 6.9 Bar/100psi: 0.77L [0.027 SCFM] Air flow @ 10 cycles / min 6.9 bar / 100psi: 7.7L/min [0.27 SCFM/min] E Air flow @ 30 cycles / min 6.9 bar / 100psi: Recommended air quality ISO 8573.1 Class 3.3.2 #: Noise Level @ 10 cycles/min & 7 bar [100 psi]: Earth connection resistance: Weight: Temperature range 23.2L/min [0.82 SCFM/min] Dirt: 5 µm Water: -20ºC@7bar (940ppm) Oil: 0.1mg/m³ Non Lubricated 68 db LAeq <1Ω 2.2 Kg [4.9 lbs] 0-40 C [32-104 F] 77-3200-R1.2 4/16

Installation EN 77-3200-R1.2 5/16

Prior To Use Re-torque end cap nuts to 8 Nm prior to use. Check periodically during use This product should be flushed with a suitable compatible solvent prior to use. Mount the pump securely and position the pump at a convenient height to allow for maintenance. Attach flexible hoses to all connections. Connect a regulated air supply to the air connection. Set the pump speed to a slow cycle rate and prime the pump to remove any air before increasing pressure. Fluid Regulator Air Pilot Set the air regulator pressure to give the desired fluid flow. The pump inlet pressure should nominally be 1 bar (15 PSI) higher. Pump Earthing The pump must be earthed at all times. A resistance <1Ω when measuring with an ohm-meter at the earth point Earth connection, Binks Part No. 0114-011798 77-3200-R1.2 6/16

Paint section materials of construction Item Pump body End cap Inlet & outlet connectors Diaphragms Seals Valve ball & spring End cap plugs Conductive acetal Conductive acetal Stainless steel PTFE FKM/PE Stainless steel Stainless steel Material 77-3200-R1.2 7/16

Spare parts Item Part No. Description 1 DXK-1 Check valve seal kit x4 2 DXK-2 Check valve kit x4 3 DXK-3 Diaphragm kit x2 4 DXK-4 Shaft & seal kit 5 DXK-5 End cap seal kit x2 6 DXK-6 Caps & screwsx2 7 DXK-7 End cap nuts x10 8 DXK-8 End cap 77-3200-R1.2 8/16

Spare Parts 77-3200-R1.2 9/16

Spare Parts Item Part No. Description 9 DXK-9 Inlet, outlet & plug connector seal kit 10 DXK-10 Male inlet connector kit 11 DXK-11 Female inlet connector kit 12 DXK-12 Male outlet connector kit 13 DXK-13 Female outlet connector kit 14 DXK-14 Air valve kit 15 DXK-15 Fluid regulator kit 16 DXK-16 Regulator cap & screws 17 DXK-17 Inlet (x2) & outlet (x2) clips 18 DXK-18 Cover, seal & screws 19 DXK-19 Female inlet / outlet thread seal x4 20 DXK-20 O-ring x5 21 DXK-21 O-ring x5 22 DXK-22 O-ring x5 23 DXK-23 O-ring x5 24 DXK-24 O-ring x5 25 DXK-25 Gasket x4 26 DXK-26 Blanking plate & screws 27 DXK-27 Blanking gasket x 4 28 DXK-28 Insert 29 0114-011798 Grounding cable 4m = parts for non-fluid regulator model 77-3200-R1.2 10/16

Spare parts 77-3200-R1.2 11/16

Maintenance Key - Maintenance symbols = Order for dis-assembly (reverse for assembly) = Grease (AGMD-010) = refer to figure = Spanner or socket size = Torque required 77-3200-R1.2 12/16

Maintenance Figure 1 Figure 2 Note #1 - Shaft fitting tool included in spares kit DXK-4 This must be used when re-fitting centre shaft 77-3200-R1.2 13/16

Maintenance schedule EN Typical period Monthly Recommended operation - Check for fluid or air leaks - Inspect Pump for Correct operation - Check for any excessive mechanical noise - Check for excessive fluid pressure pulsation 6 Months - Perform a pump stop test to ensure correct operation, by ensuring pump stops when the spraygun trigger is closed and there is no fluid flow. If pump does not stop inspect ball check valves, replace as required. - Check fluid regulator adjusts fluid pressure correctly. Replace if faulty 12 Months - Replace Diaphragms - Replace fluid regulator seat and diaphragm - Replace centre shaft and seals - Replace Check valves - Inspect and replace if required:- Air Valve module Fault finding Symptom Possible Cause Remedy Pump will not Prime a. Air getting into the suction hose/manifold b. Check valve ball/seal damaged a. Check hose connections b. Inspect, clean/replace balls/seats Pump will not run a. No Air or Fluid supply b. Air valve worn or defective a. Check air and fluid supply ball valves and supply hoses. b. Replace valve module. Pump runs but has excessive pulsation a. Air getting into fluid line, air supply restricted. b. Fluid check valves damaged c. Worn centre shaft/seals d. Worn air valve a. Check seals and hose connections. Check air supply b. Remove, clean, and inspect seat, ball, and ball cage. Replace if suspect or worn. c. Replace shaft and seals. d. Replace air valve module 77-3200-R1.2 14/16

Bare pump selection DX70 R - M F - 3 Fluid regulator R Regulator - N No regulator 1 2 3 Air regulators No regulator 1 Regulator 2 Regulators 3 Regulators For use with - DX70N DX70N DX70R Inlet type Outlet type M Male M Male F Female F Female Air regulators DXA-AC1 1 Regulator - Pump DXA-AC2 2 Regulators - Pump - Spraygun DXA-AC3 3 Regulators - Pump - Spraygun - Fluid regulator Item Part No. 1 GA-382-P Gauge 2 S-1817 Ø4mm Hose 3 ZZ-2417 QD stem 1\4" female Description 77-3200-R1.2 15/16

WARRANTY POLICY EN Binks products are covered by Finishing Brands one year materials and workmanship limited warranty. The use of any parts or accessories, from a source other than Finishing Brands, will void all warranties. For specific warranty information please contact the closest Finishing Brands location listed below. Finishing Brands reserves the right to modify equipment specifications without prior notice. DeVilbiss, Ransburg, BGK, and Binks are registered trademarks of Finishing Brands. 2013 Finishing Brands. All rights reserved. Binks is part of Finishing Brands, a global leader in innovative spray finishing technologies. For technical assistance or to locate an authorized distributer, contact one of our international sales and customer support locations below. USA/Canada www.binks.com info@finishingbrands.com Toll Free Tel: 1-800-992-4657 Toll Free Fax: 1-888-246-5732 Mexico www.finishingbrands.com.mx sales@finishingbrands.com.mx Tel: 011 52 55 5321 2300 Fax: 011 52 55 5310 4790 Brazil www.devilbiss.com.br sales@devilbiss.com.br Tel: +55 11 5641 2776 Fax: +55 11 5641 1256 United Kingdom www.finishingbrands.eu info@finishingbrands.eu Tel: +44 (0)1202 571 111 Fax: +44 (0)1202 573 488 France www.finishingbrands.eu info@finishingbrands.eu Tel: +33(0)475 75 27 00 Fax: +33(0)475 75 27 59 Germany www.finishingbrands.eu info@finishingbrands.eu Tel: +49 (0) 6074 403 1 Fax: +49 (0) 6074 403 281 China www.finishingbrands.com.cn mkt@finishingbrands.com.cn Tel: +8621-3373 0108 Fax: +8621-3373 0308 Japan www.ransburg.co.jp binks-devilbiss@ransburg.co.jp Tel: 081 45 785 6421 Fax: 081 45 785 6517 Australia www.finishingbrands.com.au sales@finishingbrands.com.au Tel: +61 (0) 2 8525 7555 Fax: +61 (0) 2 8525 7575 77-3200-R1.2 16/16