e m att Sistemas i s Sistemas t e m att t

Similar documents
CALEFFI. Ball zone valves. series /03 GB

Installation and commissioning instructions 255 series and 256 series

2-port and 3-port valves PN 16

Overview of types. Technical data. Safety notes

Solar Technology. Advantages. Everything from a single source Compact and modern design Customized models on request

HERZ-Motorised flow controler

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS

Function. brass EN CW617N brass EN CW617N brass EN CW614N. brass EN CW614N brass EN CW617N EPDM

Technical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3

Cim 787 Variable orifice balancing valve

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

V5001P. Kombi-Auto Differential Pressure Control Valve. Product specification sheet

Overview of types. Technical data

2-Port and 3-Port Seat Valves with Female Thread, PN16

2-port and 3-port seat valves, PN16

2-port seat valves PN25 with externally threaded connections

3-port seat valves with externally threaded connection, PN 16

553 Series.

Pressure independent control valve (PICV) FLOWMATIC

ACCREDITED. Technical specifications series

Two-port valves, male threaded, PN25

CLARK 200 Series Vortex Flow Transmitter Frequency Output, 1/4 to 1.0 Pipe Sizes, Rugged Molded PPA Construction

B2KL: 6-way ball valve with male thread, PN 16

CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES

Type overview. R B2 en-gb subject to changes 1

Products no longer available

Flamco Airfix D-E. Installation and operating instructions. 1999, Flamco eps

Technote. Frese PV-SIGMA Compact Dynamic Pressure and Flow Regulation. Description. Application. Operation. Features. Benefits.

Automatic balancing valves

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

ELADOS EDP L Diaphragm Metering Pump Type

Differential Pressure Control Valve. Passim

Measurement of Low GAS & Liquid Flows

TA-FUSION-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics

4/2 way Pneumatic Solenoid Valve

Pneumatic spool valve islands

Rp [ ] Sv min. [ ] C215QP-B 15 1/ C215QP-D 15 1/ C220QP-F 20 3/ [ ]

SPIROVENT VACUUM DEGASSERS

Pneumatic valve islands

differential pressure regulating valve - threaded

TA-Modulator. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve for modulating control

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

Experiment Instructions. Circulating Pumps Training Panel

INSTALLATION GUIDE MODEL NUMBER X. UniMaxx-Plus-SC-500-AC-V3 UNIMAXX SOLAR PUMP STATION

130400A 1/2 NPT Female A 3/4 NPT Female A 1 NPT Female A 1 1/4 NPT Female A 1 1/2 NPT Female A 2 NPT Female

STAD. Balancing valves DN (MD60, MD61, MD62)

Products for Cryogenic Applications

6-way characterised control valves DN15 / DN 20 / DN 25

2-Port Seat Valves with Flange, PN 16

System Pressure Manager Standard & System Pressure Manager Plus

TA-COMPACT-P. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve (PIBCV)

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz

Leak-Free Load-Control Valve SAE ½ psi flange

STAD. Balancing valves DN 15-50

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X

SonoMeter 30 Energy Meters

Automatic balancing valves ASV

SOLAR AUTOMATIC AIR VENTS AND DEAERATORS FOR SOLAR INSTALLATIONS NEW: AUTOCLOSE DOMESTIC COMMERCIAL SPIRO EXCEPTIONAL GUARANTEE

AVP-F. p setting range (bar) Code No. 003H6200

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

WE SAY: REFILL PLEASE!

Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification ATEX, IECEx, EAC

2-Port Seat Valves with Flange, PN 16

Remeha Quinta Cascade guide

Dynamic Valve Type RA-DV Pressure Independent Radiator Valve

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

50Hz. water solutions. O SerieS DGO DRO

TECHNICAL DATA. Trimpac 244a. September 16, 2013

JRGURED Pressure reducing valves

6-way characterised control valves DN15 and DN 20

Electronic Turbine Meter TERZ 94

High-performance submersible pressure transmitter For level measurement Model LH-10

Installation, operating and maintenance Instructions for Seemag bypass level indicator

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

PROPORTIONAL PRECISION PRESSURE REGULATOR REGTRONIC SERIES

CALEFFI. Flow rate metering device. 683 series 01040/10 GB. Function

[Instruments for vacuum measurement, checking and adjustment] 3

STAD-C. Balancing valves DN 15-50

GRUNDFOS alldos product information. Vaccuperm 111 / 113. Vacuum gas dosing systems for chlorine gas, ammonia, sulphur dioxide and carbon dioxide

AVPQ/AVPQ-F, PN 16. Application

Ball valve HKSF-W100. Ball valve HKSF-W100. RMA Kehl GmbH & Co. KG Oststrasse 17 D Kehl / Germany

VALVES HIDROMATIC VALVE.

ATM/GR. Electronic pressure switches CUSTOMER BENEFITS

Type 4708 Supply Pressure Regulator

Versions. Benefits. Balancing DN15-32 DN40 DN50 DN15, DN20, DN25, DN32, DN40, DN50. Dimensions

High-performance submersible pressure transmitter For level measurement Model LH-10

matrix installation guide

Self-operated Pressure Regulators for special applications

List of Contents VMA. System description 2. Individual Units Pre-Filters 3. Combinations 6. Accessories and Main spare parts 6

55.109/1. BUT: Three-way unit valve, PN 16. Sauter Components

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

Function. Code Automatic filling units with pressure gauge connection Size 1/2 Code Automatic filling units with pressure gauge Size 1/2

BOSS PULISCI PROVA IMPIANTI MEDIA

Automatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

VIESMANN. Service instructions VITOSOL 200-T, 300-T. for contractors. Vitosol 200-T, 300-T. For applicability, see the last page

Design Features. General Description

Connecting hoses. Type FS. Connecting hoses for the water-side connection of air- water systems and decentralised ventilation units PD FS 1

Pressure independent balancing and control valve AB-QM DN

Transcription:

e m att Sistemas i s Sistemas t e m att t

EFFIIENT ND SFE USE OF REGENERTIVE ENERGIES Safety and efficiency are the key criteria when installing and operating solar thermal energy systems. EFFIIENT OPERTION OF THE SOLR THERML SYSTEM When used in conjunction with conventional heating systems, regenerative energy systems secure the thermal energy requirements of buildings. Special requirements apply when integrating solar thermal systems. In addition to intrinsically safe operation, the efficient transfer of solar heat from the collector to the thermal storage station is an important criterion. The efficient operation of the solar thermal system largely depends on the system being correctly ventilated and the performance-specific adjustment of volume flow. INTRINSI SFETY OF SOLR THERML SYSTEMS Solar stations link the collector circuit to the solar storage tank. The most important functions are pumping, regulating and ventilating in order to ensure safe and efficient operation of the system under all operating conditions. Thus, the function of a solar station is not just to circulate the solar fluid, but also: Demand-driven volume flow regulation to protect against circulatory malfunctions to protect the components from overpressure to monitor the temperature to separate the air In addition, the solar station makes it easier to perform maintenance tasks when filling and emptying the various circuits by means of the integral multifunctional valves. PROTETION GINST STEM ND VITTION One of the design features of the TacoSol irc solar station is the connection for the solar expansion vessel on the intake side in front of the pump. This prevents a negative operating pressure (underpressure) from building up in front of the pump, thus ensuring that the expansion vessel and circulating pump are protected from cavitation. UTOMTI IR SEPRTION It is necessary to ventilate the solar circuit after it is first filled and during ongoing operation. ir pockets impair the operation of the system, reduce solar yield and also cause the solar fluid to age prematurely. The TacoSol irc solar station has an integrated ventilating flask with built-in manometer, the innovative design of which ensures automatic air separation both when filling the system and during ongoing operation. This makes it possible to ventilate and check the pressure of the solar circuit directly at the station. This saves time when commissioning and maintaining the solar station. VLVE ND PUMP GROUP FOR THE INTRINSILLY SFE OPERTION OF SOLR STTIONS s a compact, preassembled valve group, the TacoSol irc solar station brings together the most important regulating and safety components, such as circulating pump, safety valve, non-return valve, flow rate control, ventilating flask, manometer and thermometer. THE SUN EVEN POWERS THE PUMP When connected to a photovoltaic panel, the TacoSol irc PV EU2 also uses the solar energy to power the circulating pump. The intensity of the incident sunlight regulates the rotational speed directly by means of the solar-generated pump current, thereby also controlling the performance of the pump. This makes it possible to operate the solar thermal energy system completely independently, so that there is no need for a mains power connection. In addition, the optional D-ontrol pump controller can be used to increase the efficiency of the system. 64 taconova.com

SFE USE OF SOLR ENERGY The pre-assembled, pre-configured components in the solar stations make it easier to plan, install and efficiently operate the solar thermal energy system. ENEFITS T THE PLNNING STGE ertainty during planning and dimensioning thanks to pre-assembled main components Efficient planning thanks to hydraulic pre-dimensioning and station configuration osts can be kept under control during planning thanks to preconfigured stations and clear component specification The compact design makes planning easier Enables the planner to position himself as an innovator ENEFITS T THE INSTLLTION STGE Less time required to install, commission and maintain the system Increased sales Service and guarantee from a single source Reliable operation thanks to high quality components ompact design means that less space is required for installation Easy to provide evidence of energy yield Satisfied customers Enables the fitter to position himself as an innovator TacoSol irc Solar stations onnection-ready, fully assembled pump groups for direct installation in the solar circuit of solar power systems. Der Hydraulic balancing and flow measurement and control can be carried out directly on the solar station in all versions Permanent, automatic air separation in the integrated ventilating flask (mounted on intake side upstream of the pump on the expansion vessel connection) Product photo Station / Type Version irculating pump type omments TacoSol irc ER Single-line High-efficiency pump vailable with and without safety subassembly TacoSol irc ZR Two-line High-efficiency pump vailable with cover plate or support for controller TacoSol irc ZR PV EU2 Two-line 24 V high-efficiency pump Solar station can be operated and controlled with an autonomous power supply thanks to a PV panel taconova.com 65

TOSOL IR ER HE SINGLE LINE SOLR STTION Pump assembly with high-efficiency pumps, balancing valve and optional safety subassembly for solar heating energy systems. DVNTGES ompact Equipped with all the necessary valves and components Simple Hydraulic balancing and functional checking of the system with TacoSetter Inline 30 Pump can be changed with ease as it is lockable on the intake and output sides Simple filling, draining and servicing of the system owing to multifunctional ball valve Efficient Highly efficient system operation owing to permanent air separation with use of HE pumps Flexible Flexibility thanks to the option of integrating control systems DESRIPTION Hydraulic balancing and flow measurement can be carried out directly on the station in the case of the TacoSol irc ER HE solar station. The integrated TacoSetter Inline 30 allows the volume flow in the primary circuit to be precisely and conveniently adjusted and checked. Systems that are correctly balanced hydraulically ensure optimal energy transfer from the collector panel to the heat storage unit and therefore allow economical operation of the solar system. Using scales that are pre-calibrated for inhibitors, specialists locally can adjust and check the flow values. Training and costly measuring devices are no longer needed. INSTLLTION POSITION The solar station must be installed vertically. The installation can be carried out by a single installer. OPERTION In combination with a solar controller, the solar station transports the solar liquid heated in the collector to the hot water/drinking water storage tank via a heat exchanger. The integrated TacoSetter Inline 30 balancing valve enables the volume flow to be adjusted to the performance of the collector or heat exchanger and checked. The flow measurement of this balancing valve is based on the principle of a float. The regulating screw on the flow meter is used to adjust the flow. The reading position is the lower edge of the float element. SYSTEM/SI DIGRM UILDING TEGORIES partments, apartment blocks Single family homes, housing estates Multiple dwelling units T T 66 taconova.com

TOSOL IR ER HE SINGLE LINE DESIGN WITH SFETY SUSSEMLY SPEIFITION TEXT See www.taconova.com TEHNIL DT General Max. operating temp. T O max : Max. operating pressure P O max : 8 bar ctuating pressure of the integrated safety valve: 6 bar value and measurement range according to Type overview table Thread according to DIN 2999/ISO 7 and ISO 228 Measuring accuracy ± % of the final value For pump performance, see data sheet Grundfos PM2 5-5/30 Material Valve housing: rass Internal parts: Stainless steel, brass, plastic; borosilicate (sight glass) O-ring seals: EPDM Flat seals: FM34 Insulation: EPP Electric connection data Grundfos PM2 5-5/30 Mains voltage: 230 V ± % Mains frequency: 50...60 Hz Power consumption: Speed P [W] min. 3.8 // max. 70 I/ [] min 0.05 max. 70 0.58 Protection class: IPX4D EEI 0.23 Fluids Water mixtures with typical additives used against corrosion and freezing (display scale for medium viscosity υ = 2,3 mm²/s) Heating water (VDI 2035; SI Directive 384/; ÖNORM H 595-) old water TYPE OVERVIEW TacoSol irc ER HE Single line design with safety subassembly with high-efficiency circulating pump Order no. ) Measuring range 2) High-efficiency circulating pump 270.8006.345.5,5 6,0 l/min Grundfos PM2 5-5/30 270.806.345 3.3 4,0 6,0 l/min Grundfos PM2 5-5/30 270.8028.345 3.5 8,0 28,0 l/min Grundfos PM2 5-5/30 ¹ ) [m³/h] at υ = mm²/s ² ) Reading scale for water-glycol mix with υ = 2,3 mm²/s DIMENSIONL DRWING 2 3 onnection of collector return (G ISO 228, G " flat sealing and cutting ring] 2 onnection of storage return (G ISO 228, G " flat sealing and cutting ring) 3 onnection of expansion vessel (G ISO 228, G ¾" flat sealing and cutting ring) 4 onnection of safety valve drainage line (IG DIN 2999 / ISO 7, Rp ¾") 4 taconova.com 67

TOSOL IR ER HE SINGLE LINE DESIGN SPEIFITION TEXT See www.taconova.com TEHNIL DT General Max. operating temp. T O max : Max. operating pressure P O max : 8 bar value and measurement range according to Type overview table Thread according to ISO 228 Measuring accuracy ± % of the final value Material Valve housing: rass Internal parts: stainless steel, brass, plastic; boric silicate (sight glass) O-ring seals: EPDM Flat seals: FM34 Insulation: EPP Electric connection data Grundfos PM2 5-5/30 Mains voltage: 230 V ± % Mains frequency: 50...60 Hz Power consumption: Speed P [W] min. 3.8 // max. 70 I/ [] min 0.05 max. 70 0.58 Protection class: IPX4D EEI 0.23 Fluids Water mixtures with typical additives used against corrosion and freezing (display scale for medium viscosity υ = 2,3 mm²/s) Heating water (VDI 2035; SI Directive 384/; ÖNORM H 595-) old water TYPE OVERVIEW TacoSol irc ER HE Single line design with high-efficiency circulating pump Order no. ) Measuring range 2) High-efficiency circulating pump 270.8006.000,5,5 6,0 l/min Grundfos PM2 5-5/30 270.806.000 3,3 4,0 6,0 l/min Grundfos PM2 5-5/30 270.8028.000 3,5 8,0 28,0 l/min Grundfos PM2 5-5/30 ¹ ) [m³/h] at υ = mm²/s ² ) Reading scale for water-glycol mix with υ = 2,3 mm²/s DIMENSIONL DRWING p [kpa] 0 H [m] 2 3 onnection of collector return (G ISO 228, G " flat sealing and cutting ring] 2 onnection of storage return (G ISO 228, G " flat sealing and cutting ring) 3 onnection of expansion vessel (G ISO 228, G ¾" flat sealing and cutting ring) PUMPENKENNLINIE HRTERISTI 80 60 40 20 0 8 6 4 2 0 0.0 0.2 0.4 0.6 0.8.0.2.4.6.8 2.0 2.2 2.4 2.6 Q [m³/h] P [W] 70 60 50 40 30 20 0 0.0 0. 0.2 0.3 0.4 0.5 0.6 0.7 Q [l/s] 0.0 0.2 0.4 0.6 0.8.0.2.4.6.8 2.0 2.2 2.4 2.6 Q [m³/h] 68 taconova.com

TOSOL IR ER HE SINGLE-LINE SOLR STTION PRESSURE LOSS DIGRMS 270.X006.XXX (DN 20 ",5...6 l/min) 00 270.X06.XXX (DN 20 " 4...6 l/min) 00 270.X028.XXX (DN 20 " 8...28 l/min) 00 0 D 0 D 0 0,,5 6 =,5 = 3,3 = 3,5 4 6 0 8 28 0 Flow (l/min) Flow (l/min) Flow (l/min) D Return characteristics of valve position for TacoSetter Inline 30 ESSORIES SOLDER JOINT PRESSURE FITTING Flat sealing connector joint, consisting of a soldered connecting nipple, lock nut and flat seal suitable for solar technology Order no. G x mm Version for 2.533.09 " x 8 mm opper pipe 8 mm 2.5332.09 " x 22 mm opper pipe 22 mm FILL ND DRIN OK 3WY ONNETOR For connection to the expansion vessel connector piece, consisting of a T- joint with fill and drain cock, lock nut with G ¾" internal thread with flat seal suitable for solar technology, G ¾" outer thread connector. Order no. DN G 296.700.354 20 ¾" EXPNSION VESSEL MOUNTING RKET WITH QUIK TION OUPLING For mounting the expansion vessel on the wall with quick-action shut-off coupling x internal thread, x external thread G ¾". Order no. DN G 296.7002.000 20 ¾" STINLESS STEEL TUE For connecting the expansion vessel, incl. ¾" lock nut and flat seals suitable for solar technology. Order no. DN G Length 296.7003.000 20 ¾" 0,5 m SOLR ONTROLLER SOREL Order no. Type Info 296.703.000 TD 3 omplex solar systems and high efficiency pumps taconova.com 69

TOSOL IR ZR HE TWO-LINE SOLR STTION Two-line pump assembly with high-efficiency pumps, balancing valve, ventilation unit and safety subassembly for solar heating energy systems DVNTGES ompact: Equipped with all the necessary valves and components Secure: Intrinsic safety of the system thanks to an integrated safety subassembly Simple: Hydraulic balancing and functional checking of the system with Tacosetter Inline 30. Pump can be changed with ease as it lockable on the intake and output sides Efficient: Highly efficient system operation owing to permanent air separation and use of highefficiency pumps Flexible: Flexibility thanks to the option of integrating control systems DESRIPTION Hydraulic balancing, flow measurement and ventilation can be carried out directly on the station in the case of the TacoSol irc ZR HE solar station. The integrated TacoSetter Inline 30 allows the volume flow in the primary circuit to be precisely and conveniently adjusted and checked. Permanent air separation in the integrated ventilating flask allows energy-efficient operation of the system. Systems that are correctly balanced hydraulically and air-free guarantee optimal energy extraction and are thus more cost-effective in the sense of the energy-saving directives laid down by law. SYSTEM/SI DIGRM Using scales that are pre-calibrated for inhibitors, specialists locally can adjust and check the flow values. Training and costly measuring devices are no longer needed. INSTLLTION POSITION The solar station must be installed vertically to ensure that the ventilation unit functions correctly. Installation and ventilation can be performed by a single installer. OPERTION In combination with a solar controller, the solar liquid heated in the collector is transported to the hot water/drinking water storage tank via a heat exchanger with the help of the solar station. The integrated TacoSetter Inline 30 balancing valve enables the volume flow to be adjusted to the performance of the collector or heat exchanger and checked. The flow measurement of this balancing valve is based on the principle of a float. The regulating screw on the flow meter is used to adjust the flow. The reading position is the lower edge of the float element. The integrated ventilating flask with innovative flow technology design ensures permanent air separation and thereby increases the efficiency of the system. UILDING TEGORIES partments, apartment blocks Single family homes, housing estates Multiple dwelling units T T 70 taconova.com

TOSOL IR ZR HE TWO-LINE SOLR STTION SPEIFITION TEXT See www.taconova.com TEHNIL DT General Maximal operating temperatures: Flow line (ventilator side) T O max : 60 Return line (pump side) T O max : Max. operating pressure P O max : 8 bar ctuating pressure of the integrated safety valve: 6 bar value and measurement range according to Type overview table Thread according to DIN 2999/ISO 7 and ISO 228 Measuring accuracy ± % of the final value Material Vent pipe: Painted steel Valve housing parts: rass Internal parts: Stainless steel, brass and plastic, borosilicate (sight glass) O-ring seals: EPDM Flat seals: FM34 Insulation: EPP Electric connection data Grundfos PM2 5-5/30 Mains voltage: 230 V ± % Mains frequency: 50...60 Hz Power consumption: Speed P [W] min. 3.8 // max. 70 I/ [] min 0.05 max. 70 0.58 Protection class: IPX4D EEI 0.23 Fluids Water mixtures with typical additives used against corrosion and freezing (display scale for medium viscosity υ = 2,3 mm²/s) Heating water (VDI 2035; SI Directive 384/; ÖNORM H 595-) old water TYPE OVERVIEW TacoSol irc ZR HE Two-line design with high-efficiency pump Version with carrier for controller Order no. ) 2) Measuring range 3) irculating pump 270.8506.356,5 6,0,5 6,0 l/min WILO ST 20/6-3 270.856.356 3,3 6,0 4,0 6,0 l/min WILO ST 20/6-3 270.8528.356 3,5 6,0 8,0 28,0 l/min WILO ST 20/6-3 TacoSol irc ZR HE Two-line design with high-efficiency pump Version with cover plate Order no. ) 2) Measuring range 3) High-efficiency pump 270.8506.000,5 6,0,5 6,0 l/min Grundfos PM2 5-5/30 270.856.000 3,3 6,0 4,0 6,0 l/min Grundfos PM2 5-5/30 270.8528.000 3,5 6,0 8,0 28,0 l/min Grundfos PM2 5-5/30 ) [m³/h] at υ = mm²/s in the return line (pump side) 2) [m³/h] at υ = mm²/s in the flow line (ventilator side) 3) Reading scale for water-glycol mix with υ = 2,3 mm²/s DIMENSIONL DRWING 6 2 3 4 5 onnection of collector flow (G ISO 228, G " flat sealing and cutting ring) 2 onnection of collector return (G ISO 228, G " flat sealing and cutting ring) 3 onnection of storage flow (G ISO 228, G " flat sealing and cutting ring) 4 onnection of storage return (G ISO 228, G " flat sealing and cutting ring) 5 onnection of expansion vessel (G ISO 228, G ¾" flat sealing and cutting ring) 6 onnection of safety valve drainage line (IG DIN 2999 / ISO 7, Rp ¾") PUMPENDIGRMM p [kpa] 0 80 60 40 20 0 H [m] 8 6 4 2 0 0.0 0.2 0.4 0.6 0.8.0.2.4.6.8 2.0 2.2 2.4 2.6 Q [m³/h] 0.0 P 0. 0.2 0.3 0.4 0.5 0.6 0.7 Q [l/s] [W] 70 60 50 40 30 20 0 0.0 0.2 0.4 0.6 0.8.0.2.4.6.8 2.0 2.2 2.4 2.6 Q [m³/h] taconova.com 7

TOSOL IR ZR HE TWO-LINE SOLR STTION PRESSURE LOSS DIGRMS 270.X506.XXX (DN 20 ",5...6 l/min) 00 270.X56.XXX (DN 20 " 4...6 l/min) 00 270.X528.XXX (DN 20 " 8...28 l/min) 00 0 D =,5 = 6,0 0 D = 3,3 = 6,0 0 = 3,5 = 6,0 D V V V 0,,5 6 4 6 0 8 28 0 Flow (l/min) Flow (l/min) Flow (l/min) D Return characteristics of valve position for TacoSetter Inline 30 V Flow characteristic (vent line] OMPONENTS 3 Manometer Display range 0- bar 9 Thermometer Display range 0-60 6 4 Thermometer Display range 0-60 Dipping sensors installed in the safety pipe 2 7 Dipping sensors installed in the safety pipe Expansion vessel connection G ¾" 3 8 4 9 5 5 Wall mounting 6 Shutoff ball valve with integrated backflow preventer as well as filling and draining valve Multifunctional valve for filling, draining and shutting off the collector circuit Hose connection outer thread G ¾" Insulation and mounting accessories 2 hexagon wood screws 8 x 50 mm 2 washers 2 mounting pins x 50 mm Installation instructions Operating and safety instructions Shutoff ball valve with safety valve and integrated backflow preventer Integrated backflow preventer and Option of lead sealing to protect against incorrect operation by the handle 7 irculation pump solar version Grundfos PM 2 5-5/30 check valve Option of lead sealing to protect against incorrect operation by the handle Safety valve function in each ball valve position guaranteed in accordance with safety standards 8 TacoSetter Inline 30 balancing valve Sight glass with scale for medium viscosity of = 2.3 mm2/s Setting ranges in accordance with design.5-6 l/min 4-6 l/min 8-28 l/min 2 Ventilating flask with ventilating valve Permanent air separation ir collection volume 2.5 dl Integrated manual air vent for ventilating and checking the leak tightness Integrated shut-off function Hydraulic balancing of pump group without correction curves and measuring devices Functional checking of system at sight glass 72 taconova.com

TOSOL IR ZR HE TWO-LINE SOLR STTION ESSORIES SOLDER JOINT PRESSURE FITTING Flat sealing connector joint, consisting of a soldered connecting nipple, lock nut and flat seal suitable for solar technology. Order no. G x mm Version for 2.533.09 " x 8 mm opper pipe 8 mm 2.5332.09 " x 22 mm opper pipe 22 mm FILL ND DRIN OK 3 WY ONNETOR For connection to the expansion vessel connector piece, consisting of a T-joint with fill and drain cock, lock nut with G ¾" inner thread with flat seal suitable for solar technology and G ¾" outer thread connector. Order no. DN G 296.700.354 20 ¾" EXPNSION VESSEL MOUNTING RKET WITH QUIK TION OUPLING For mounting the expansion vessel on the wall with quick-action shut-off coupling. x inner thread, x outer thread G ¾". Order no. DN G 296.7002.000 20 ¾" STINLESS STEEL TUE For connecting the expansion vessel, incl. ¾" lock nut and flat seals suitable for solar technology. Order no. DN G Length 296.7003.000 20 ¾" 0,5 m SOLR ONTROLLER SOREL Order no. Type pplication 296.706.000 TD 4 Version with high-efficiency pumps RRIER FOR ONTROLLER Order no. pplication 296.7020.000 TacoSol irc ZR HE OVER PLTE Order no. pplication 296.702.000 TacoSol irc ZR HE taconova.com 73

TOSOL IR ZR PV EU2 TWO-LINE SOLR STTION WITH HIGH-EFFIIENY D PUMP DVNTGES ompact: Equipped with all the necessary valves and components Secure: Intrinsic safety of the system thanks to an integrated safety subassembly Simple: Hydraulic balancing and functional checking of the system with Tacosetter Inline 30 Pump can be changed with ease as it lockable on the intake and output sides Efficient: Highly efficient system operation owing to permanent air separation and use of HE pumps Flexible: Flexibility thanks to the option of integrating control systems Two-line solar station with 24V HE D pump, balancing valve, ventilation unit and safety subassembly for independent operation in solar heating energy systems DESRIPTION The TacoSol irc ZR PV EU2 is a solar station with a high-efficiency D pump, which can be powered and controlled directly by the current of a photovoltaic panel. This eliminates the otherwise customary mains connection and enables independent operation of the solar system. Hydraulic balancing, flow measurement and ventilation can be carried out directly on the station. The integrated TacoSetter Inline 30 allows the volume flow in the primary circuit to be precisely and conveniently adjusted and checked. Permanent air separation in the ventilating flask SYSTEM/SI DIGRM allows energy-efficient operation of the system. Systems that are correctly balanced hydraulically and air-free guarantee optimal energy extraction and are thus more cost-effective in the sense of the energy-saving directives laid down by law. Using scales that are pre-calibrated for inhibitors, specialists locally can adjust and check the flow values. Training and costly measuring devices are no longer needed. T T INSTLLTION POSITION The solar station must be installed vertically to ensure that the ventilation unit functions correctly. Installation and ventilation can be performed by a single installer. OPERTION The solar liquid heated in the collector is transported to the hot water/ drinking water storage tank via a heat exchanger in the two-line TacoSol irc ZR PV EU2 solar station. The output of the integrated highefficiency D pump is regulated independently in combination with a photovoltaic panel based on the intensity of the global radiation and the voltage generated in the photovoltaic module. D controller can be installed between the photovoltaic module and the pump to monitor the temperature differential. The integrated TacoSetter Inline 30 balancing valve enables the volume flow to be adjusted to the performance of the collector or heat exchanger and checked. The integrated ventilating flask with innovative flow technology design ensures permanent air separation and thereby increases the efficiency of the system. 74 taconova.com

TOSOL IR ZR PV EU2 TWO-LINE SOLR STTION WITH HIGH-EFFIIENY D PUMP SPEIFITION TEXT See www.taconova.com TEHNIL DT General Max. operating temperatures: Flow line (ventilator side): T O max : 60 Return line (pump side): TYPE OVERVIEW TacoSol irc ZR PV EU2 Two-line solar station Order no. ) 2) Measuring range 3) irculating pump 270.7506.000,5 6,,5 6,0 l/min Laing D5 Solar 270.756.000 3,3 6,0 4,0 6,0 l/min Laing D5 Solar ) [m³/h] at υ = mm²/s in the return line (pump side) 2) [m³/h] at υ = mm²/s in the flow line (ventilator side) 3) Reading scale for water-glycol mix with υ = 2,3 mm²/s T O max : 95 Max. operating pressure: DIMENSIONL DRWING P O max : 8 bar ctuating pressure of the integrated 85 74 85 safety valve: 6 bar value and measurement range according to Type overview table Thread according to DIN 2999/ISO 7 30 6 2 30 and ISO 228 Measuring accuracy ± % of the final value Material Vent pipe: Painted steel Valve housing: rass Internal parts: Stainless steel, brass, plastic; borosilicate (sight glass) O-ring seals: EPDM Flat seals: FM34 Insulation: EPP Electric connection data Rated voltage 8-24 Volt (operation via a 2 V panel; with a 24 V panel only with maximum voltage limit of 24 V) Power consumption*: ø2,5 30 = = 3 4 = = 40 5 78 300 445 3 30 30 5 384 32 ø2,5 Minimal start-up power less than Watt (at 2 Volt) Maximum power input approx. 22 W; current consumption 0.25 -.46 (* power input and start-up may vary from system to system) Insulation class IP 42 / lass F Fluids Water mixtures with typical additives used against corrosion and freezing (display scale for medium viscosity υ = 2,3 mm²/s) Heating water (VDI 2035; SI Directive 384/; ÖNORM H 595-) old water Note Safe power-off of the pump at approx. 95 87 25 78 290 onnection of collector flow (G ISO 228, G " flat sealing and cutting ring) 2 onnection of collector return (G ISO 228, G " flat sealing and cutting ring) 3 onnection of storage flow (G ISO 228, G " flat sealing and cutting ring) 4 onnection of storage return (G ISO 228, G " flat sealing and cutting ring) 5 onnection of expansion vessel (G ISO 228, G ¾" flat sealing and cutting ring) 6 onnection of safety valve drainage line (IG DIN 2999 / ISO 7, Rp ¾") 35 50 87 taconova.com 75

TOSOL IR ZR PV EU2 TWO-LINE SOLR STTION WITH HIGH-EFFIIENY D PUMP PRESSURE LOSS DIGRMS 270.7506.000 (DN 20 ",5...6 l/min) 270.756.000 (DN 20 " 4...6 l/min) 00 00 0 D =,5 = 6, 0 D F 0,,5 6 Flow (l/min) D Return characteristics of valve position for TacoSetter Inline 30 V Flow characteristic (vent line] = 3,3 4 6 0 Flow (l/min) OMPONENTS 3 Manometer Display range 0 - bar 9 onnection terminals Wago Electrical connection to the photo- 6 4 Thermometer Display range 0-60 Dipping sensors installed in the voltaic panel Thermometer Display range 0-60 3 4 2 5 7 8 Shutoff ball valve with safety valve and integrated backflow preventer Integrated backflow preventer 9 safety pipe 5 Wall mounting 6 Shutoff ball valve with integrated backflow preventer as well as filling and draining valve (KFE) Multifunctional valve for filling, draining and shutting off the collector circuit Hose connection outer thread G ¾" Option of lead sealing to protect against incorrect operation by the handle 7 irculation pump Laing D5 D 8-24 V Dipping sensors installed in the safety pipe Expansion vessel connection G ¾" Insulation and mounting accessories 2 hexagon wood screws 8 x 50 mm 2 washers 2 mounting pins x 50 mm Installation instructions Operating and safety instructions and check valve Option of lead sealing to protect against incorrect operation by the handle Safety valve function in each ball valve position guaranteed in accordance with safety standards. 2 Ventilating flask with ventilating valve Permanent air separation Impeller mounted on ultra-hard ceramic ball Delivery pressure 2.8 m 8 TacoSetter Inline 30 balancing valve Sight glass with scale for medium viscosity of = 2,3 mm²/s Setting ranges in accordance with design.5-6 l/min I 4-6l/min I 8-28 l/min Integrated shut-off function ir collection volume 2.5 dl Integrated manual air vent for ventilating and checking the leak tightness Hydraulic balancing of pump group without correction curves and measuring devices Functional checking of system at sight glass 76 taconova.com

TOSOL IR ZR PV EU2 TWO-LINE SOLR STTION WITH HIGH-EFFIIENY D PUMP ESSORIES SOLDER JOINT PRESSURE FITTING Flat sealing connector joint, consisting of a soldered connecting nipple, lock nut and flat seal suitable for solar technology Order no. G x mm Version for 2.533.09 " x 8 mm opper pipe 8 mm 2.5332.09 " x 22 mm opper pipe 22 mm FILL ND DRIN OK 3 WY ONNETOR For connection to the expansion vessel connector piece, consisting of a T-joint with fill and drain cock, lock nut with G ¾" inner thread with flat seal suitable for solar technology and G ¾" outer thread connector. Order no. DN G 296.700.354 20 ¾" EXPNSION VESSEL MOUNTING RKET WITH QUIK TION OUPLING For mounting the expansion vessel on the wall with quick-action shut-off coupling. x inner thread, x outer thread G ¾". Order no. DN G 296.7002.000 20 ¾" STINLESS STEEL TUE For connecting the expansion vessel, incl. ¾" lock nut and flat seals suitable for solar technology. Order no. DN G Length 296.7003.000 20 ¾" 0,5 m PV PNEL Including mounting material Order no. Output voltage Size 298.5030.000 6 W (peak) 2 x 55 mm D ONTROL Including two temperature sensors (PT00) and a potential equalization cable Order no. Operating power Size 296.704.362 5-24 V D 56 x 33 mm taconova.com 77