Automatic Control Unit. Controlmatic E.2. Type Series Booklet

Similar documents
Automatic Control Unit. Controlmatic E. Type Series Booklet

Automatic Control Unit. Cervomatic EDP.2. Type Series Booklet

KSB Delta Compact Type Series Booklet

KSB Delta Compact Type Series Booklet

Tightness controls TC 1 3 and TC 4

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz

Pressure switches for air and water CS

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

Governor with solenoid valve VAD Air/gas ratio control with solenoid valve VAG

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves single-stage atmospheric operating mode GB-(LEP) 057 D01

Old documentation - Only for your information! Product is not available any more!

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

Pressure independent control valve (PICV) FLOWMATIC

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

Pressure regulator with solenoid valve VAD Air/gas ratio control with solenoid valve VAG

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

SPIROVENT VACUUM DEGASSERS

KIT. Small Automatic Water Boosters KIT MODELS

USER S MANUAL BASIC HORIZONTAL OIL-LUBRICATED MICROCOMPRESSOR Reference: RCMPBH

Pressure Measurement Single-range transmitters for general applications

3-Way Safety Block DSV

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 055 D01

Old documentation - Only for your information! Product is not available any more!

Tightness control TC. Product brochure GB 3 Edition AGA

Compact pressure switches for gas and air

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

Rigel 601 CHECKBOX. Instruction Manual. 348A551 Issue 2.0. April Seaward Electronic Ltd. Issue 2.0

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Integrated gas-air system GB-GD 057 D01

MECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET

Etanorm V Type Series Booklet

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH

Flamco Flexcon M-P Pump automat

KMW3000C. User Manual. Water Chiller for Xcalibur and Gemini systems. Version 1.6, September 2010

Self-operated Pressure Regulators for special applications

Air Purge Unit. Series: LSP-compact Type: EJG 2-2. (Controlled with DigiFlow 515) Installation & Operation Manual 11/2014

Valve Proving System VDK 200 A S06*

Valve Proving System VDK 200 A S02

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

Pressure transmitters EMP 2

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

2-port and 3-port seat valves, PN16

Electromechanical pressure switches

Differential Pressure Control Types MP 54, MP 55 and MP 55A

VERTICAL AIR COMPRESSORS

2-Port and 3-Port Seat Valves with Female Thread, PN16

Hydro Dome GRUNDFOS INSTRUCTIONS

MOYNO FLUID DETECTION CONTROL SERVICE MANUAL. Section: ACCESSORIES. Page: 1 of 8 Date: May 1, 1998 GENERAL

Automatic Valve Proving Control

Differential pressure switch MP 54, MP 55 and MP 55A

Instruction Manual Contact Pressure Vacuum Gauge

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners

CALEFFI. Ball zone valves. series /03 GB

Safety. Operating instructions Solenoid valve for gas VG 10/15 VG 65 DANGER. Contents WARNING CAUTION. Changes to edition 11.14

Gas density monitor With integrated transmitter Model GDM-100-TI

Columbus Instruments

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

Vaporizer Technique. FAS Flüssiggas-Anlagen GmbH

2-Port Seat Valves with Flange, PN 16

Evaporating Pressure Regulating Valve Type KVQ REFRIGERATION AND AIR CONDITIONING. Technical leaflet

3-port seat valves with externally threaded connection, PN 16

Airfix. Flamco. Flamco. Pressure expansion vessels for sanitary appliances and potable water systems AIRFIX A AIRFIX D AIRFIX D-E

KERN EG/EW Version /02

FLOW. State of the Art ELECTRONIC PUMPS CONTROLLERS. * Electronic starters. * Inverters. * Protection devices YOURWATER UNDER CONTROL

Two-port seat valves

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

2-port and 3-port valves PN 16

VR46.5V(A)/VR86.5V(A) SERIES

Selection of ICF made easy Save even more time with ICF

Solenoid valves VZWF, force pilot operated

Installation, Operation & Maintenance Instructions

EXH. Specifications. Descriptions. Min. working pressure MPa

Old documentation - Only for your information! Product is not available anymore!

Pressure regulator with solenoid valve VAD Air/gas ratio control with solenoid valve VAG Variable air/gas ratio control with solenoid valve VAV

2-Port Seat Valves with Flange, PN 16

JUMO dtrans p30 Pressure Transmitter

VRF. Technical Data Book. DVM S ECO for Europe (R410A, 50Hz, HP) Model : AM***KXMDGH/EU

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

AutoChanger Installation & User Guide Issue 2

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

Electro-Pneumatic Converter YT-940 SERIES

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type

Flamco Flamco-Fill STA Flamco-Fill STM

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

WhirlWind Multifunctional gas control Fully integrated gas-air system with control and safety function GB-WND 055 D01

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

2-step solenoid valve Type ICLX

2-step solenoid valve Type ICLX

VERTICAL AIR COMPRESSORS

Control units. Installation and operating instructions Series: DP-Control

OPTIBAR P 1010 C Technical Datasheet

Safety and Shut-off Block SAF/DSV

Transcription:

Automatic Control Unit Controlmatic E.2 Type Series Booklet

Legal information/copyright Type Series Booklet Controlmatic E.2 All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed for any other purpose, nor otherwise transmitted, published or made available to a third party without the manufacturer's express written consent. Subject to technical modification without prior notice. KSB Aktiengesellschaft, Frankenthal 08.10.2013

Building Services: Water Supply Building Services: Water Supply Controlmatic E.2 Designation Example: Controlmatic E.2 Key to the designation Code Description Controlmatic Type series E Single-phase AC.2 Product version Configuration and function Main applications Pressure-controlled starting, stopping and monitoring of small pumps in water supply systems Can be used with the following pumps ( Page 6) Type series Size Connection Multi Eco 33 E, 34 E, 35 E, G 1 36 E, 65 E Ixo 45 E, 55 E, 65 E, G 1 1 / 4 48 E, 58 E S 100D 1/7, 1/9, 1/12, 1/14, G 1 1 / 4 1/16, 2/7, 2/11, 2/15, 2/18, 4/4, 4/6, 4/9, 4/12, 7/5, 7/7, 7/9 UPA 100C 2/6, 2/8, 2/13, 2/17, 3/6, 3/9, 3/12, 3/15, 4/4, 4/7, 4/9, 4/14 G 1 1 / 4 Fluids handled Drinking water Service water Stormwater Fire-fighting water Cooling water Operating data Operating properties Characteristic Value Flow rate Q Up to 10 m 3 /h (2.77 l/s) Minimum flow rate Q min 0.1 m 3 /h Start-up pressure (nonadjustable) p 1.5 bar Design of Controlmatic E.2 1 Housing 5 Green signal lamp - Energised 2 Pressure gauge 6 Amber signal lamp - Pump running 3 Plug socket to IEC 60884-1 for connecting the pump 4 Power cable with shockproof plug Function 7 Red signal lamp - Fault or lack of water The pump can be connected via the plug socket (3) of the automatic control unit. Once the power cable with shockproof plug (4) has been connected to the power supply, the automatic control unit is ready for operation. The green signal lamp (5) is lit. When a shut-off valve in the piping is opened, the system pressure decreases and the pump is started up. The system pressure is indicated at the pressure gauge (2). The pump starts to deliver fluid and the amber signal lamp (6) is lit. When the tap has been closed and the flow rate is zero, the pump is stopped after 10 seconds. Protective functions The pump is protected against dry-running by simultaneous monitoring of pressure and flow rate. If there is a lack of water, the automatic control unit stops the pump and the red signal lamp (7) is lit. Controlmatic E.2 3

Building Services: Water Supply Materials Overview of materials used Component Material Housing Polyamide Membrane Elastomer Product benefits Easily connected to power supply by shockproof plug The pump is started and stopped automatically by simultaneous monitoring of pressure and flow rate. Dry-running protection by stopping the motor User-friendly due to integrated pressure indication Certifications Designation Valid in: Note ACS France French drinking water approval Selection information System pressures 10 bar may damage the automatic control unit and must be avoided by all means. The start-up pressure of the automatic control unit must always be lower than the maximum pressure at zero flow. Minimum flow rate: 0.1 m³/h The start-up pressure has been set to 1.5 bar. Maximum pressure capability: Pressure suction side + pressure max. pump (at zero flow) 10 bar If in doubt about the suction side pressure: either add a safety margin of 3 bar to the nominal pressure (Pressure suction side + 3 bar) + [Pressure max. pump (at zero flow)] 10 bar or fit a pressure reducer (stabiliser) between the pump and the automatic control unit or on the pump's suction side, to prevent excessive pressure. If pressure surges are to be expected in the system as a result of quick-closing valves (e.g. solenoid valves) please contact KSB to check the unit's suitability for the specific application. H 1 2 3 H 5 6 7 0 4 Q 0 Q H/Q diagrams 1 Minimum flow rate 5 Curve to be selected 2 Minimum start-up pressure 6 Curve to be avoided 3 Pump start-up point 7 Maximum operating point 4 Pump stop point 4 Controlmatic E.2

Building Services: Water Supply Pressure curve Unlike domestic water supply systems with accumulators, pumps operated with automatic control units maintain a characteristically constant pressure at any flow rate. Pressure curves Technical data Selection table Description Value Maximum operating pressure 10 bar 1) Start-up pressure 1.5 bar Flow rate 10 m 3 /h (2.77 l/s) Enclosure IP 65 Maximum ambient temperature 0 to 60 C Maximum fluid temperature 0 to 60 C Mains voltage 1 ~ 230 V, 50/60 Hz Maximum pump current 10 A Protection against lack of water Yes Restart after detected lack of water Manual Weight 1.3 kg Mat. No. 39300031 1) The automatic control unit must be protected against any pressures exceeding the maximum operating pressure. Otherwise, the automatic control unit might be damaged! Controlmatic E.2 5

Building Services: Water Supply Dimensions Dimensions [mm] A Pump connection: cable H07RN-F 0.5 m, with standard plug socket to IEC 60884-1 B Mains connection: cable H07RN-F 1.5 m, with plug, 16 A, 250 V, twin earth terminals (to CEE 7/VII) Notes on installation 1~ 220 V / 240 V 1~ 220 V / 240 V Typical installation positions NOTE! The automatic control unit is not suitable for outdoor installation and must be protected from weather. Accessories Connnection parts Connnection parts Description Connection Mat. No. [kg] Connection part made of brass for Controlmatic for Multi Eco type series (1 piece) Rp 1 / G 1 39019415 0.2 for Ixo, S 100D type series (1 piece) Rp 1¼ / G 1 39019530 0.2 6 Controlmatic E.2

KSB Aktiengesellschaft 67225 Frankenthal Johann-Klein-Str. 9 67227 Frankenthal (Germany) Tel. +49 6233 86-0 Fax +49 6233 86-3401 www.ksb.com 5125.52/04-EN 08.10.2013