JORDAIR/BAUER Service Manual

Similar documents
Service Manual. Maintenance. BAUER Breathing Air Compressor Units

INSTRUCTION AND OPERATION MANUAL FOR JORDAIR COMPRESSORS

PC1131 Electric Air Compressor

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

INSTRUCTION AND OPERATION MANUAL FOR JORDAIR COMPRESSORS

THE COMPACT LINE. Mobile power packs in convincing BAUER quality l/min 225 / 330 bar TOUGH RELIABLE WELL ESTABLISHED

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

Breathing Air Compressor Bid Specification

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL

accidents which arise due to non-observance of these instructions and the safety information herein.

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Part IV: Troubleshooting

Code AWC20HP Air Compressor

Brownie s. Commercial Series NMCS-30 NMCS NW 1st Street, Fort Lauderdale, FL PH Fx

EGL-12 OIL-LESS COMPRESSOR

COMPRESSOR MANUAL. (888)

Calera Fire Department Breathing Air System Technical Specifications

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

SERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL

SERVICE MANUAL MODEL BA200AMST-S1 BREATHING AIR PANEL

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

200 PSI FAST-FILL AIR SOURCE KIT

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

High Pressure Breathing Air Compressors

Budget Range Operators Handbook

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

TECHNICAL DATA. Q = C v P S

INSTRUCTION MANUAL MST AFTERCOOLER SYSTEM MODEL

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

SF SERIES CNG COMPRESSOR MODEL HF-4MH. 4 Nm3/Hour Displacement OPERATION MANUAL

200 PSI HIGH-FLOW AIR SOURCE KIT

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

310 SERIES TILT-TO-LOAD ROTATOR. The Specialist In Drum Handling Equipment

Right-Angle Tube Roller Model

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

4 ANGLE GRINDER MODEL NO: CAT 52 PART

TECHNICAL DATA. Q = C v P S

Related Products: Auto Drain Valve. Model/Specifications. Model

User Instruction Manual

Instructions for: COMPRESSORS 270ltr belt drive 5.5 / 7.5 hp

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

NGP-250/500 Nitrogen Generator Quick Start Guide

TECHNICAL DATA. Q= Cv S

hydro-pac, inc. Low-Pressure Gas Compressors 1500 to 6000 PSI

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

Operating Instructions Model and Hydrostatic Test Pump

Portable Oil Lube Air Compressors

Model PSI Compressor with 3-Gallon Air Tank 12VDC

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons

TECHNICAL DATA. Q = C v P S

Linde Cryogenics. Helium Recovery Systems.

Marschalk Model # 94000

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Air Compressor Electric Handheld

OPERATION MANUAL NTF-15

Types 749B and R130 Changeover Manifolds

CUT OFF TOOL MODEL: CAT113

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

OPERATION MANUAL NTF-60 Plus

Instruction Manual ATLANTIC 100

OPERATION AND MAINTENANCE INSTRUCTION MANUAL

Product Range. High performance and economic high pressure solutions Made in Germany

Water Mist Systems Inspection, Testing, and Maintenance of Water Mist Systems

Operating Manual. Model BAC-30RT30/BAC-30DC

RG3100 and RG3100Ice Regulator System

200 PSI COMPRESSORS - MODEL NUMBERS

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

TECHNICAL DATA OBSOLETE

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank

IMPORTANT SAFETY INSTRUCTIONS

100C Air Compressor Kit

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor

444C DUAL PERFORMANCE VALUE PACK

Mobile Breathing Air Systems

8-gallon Air Compressor. Owner s Manual

2 HP / 4 GALLON AIR COMPRESSOR OPERATING MANUAL

Mitigation Starts With Design! Continues with Safe Operation, Mechanical Integrity and Training!

the new Ve- / VSE Range

compressors belt drive 100ltr/3.0hp 150ltr/3.0hp, 200ltr/3.0hp direct drive

R E D I C O N T R O L S

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Piped Air SCBA Refilling System Standard

3/8" Dr. Air Butterfly Impact Wrench

AA-75CF Portable Air Compressor NSN:

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

1 HP / 1.6 GALLON AIR COMPRESSOR OPERATING MANUAL

TECHNICAL INFORMATION

Oxygen Usage Best Practice Guide

!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7

CO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype

Nitrogen Advantage. Better Tire Pressure Retention. Improved Fuel Economy. Extended Tread Life. Elimination of Oxidation. Reduction in Tire Failures

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

Guideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society

Transcription:

JORDAIR/BAUER Service Manual Breathing Air Compressor Maintenance Log Doc. ServiceManual Page - 1

SAFETY RELEASE-2016 The following document is prepared to ensure safety of operators and service technicians. The information applies to all types of high pressure breathing air compressors. All compressors should have a cycle counter for the drain system to provide accurate tracking for actual pressure cycles of the inter-stage and final oil and water separator. All separators have cycle life limits and failure to abide by this safety issue can result in a catastrophic failure of the separator. Under normal operation the cycle counter reading will be between 5 to 7 times the operating hours. If the cycle counter shows more cycles then this indicates either a leaking or failed check valve or short operation cycles. Contact the factory for the recommended cycle life limit and replacement schedule for these parts. Correct maintenance of breathing air systems ensures operator safety. A compressor should always have an operation cycle of 20 minutes or longer to avoid short compressor and auto-drain cycles. The compressor fill station should be sized to fill enough cylinders that the required air for filling the SCBA cylinders is equal to or more than the compressor capacity in 15 minutes of operation. Never operate a high pressure compressor in an unheated building where temperatures can reach 0C or lower. A water saturated filter cartridge can freeze and expand up to 10% of its diameter and cause the chamber to be over stressed and fail. Always ensure daily compressor checks when a remote operation switch is located at the filling position of SCBA or other breathing air cylinders. All breathing air compressors are to be checked operated and confirmed safe for operation each day for 15 minutes to ensure correct operation and compressor system lubrication. High pressure tubing downstream of the compressor is to be sized to ensure unrestricted air flow and avoid short operational cycles. Short cycles can occur from long distance and undersized tube runs. All compressor operators and service personnel are to be factory trained and maintain a current certificate of competence as stated in the CSA breathing air standard. Following these safety recommendations will keep the compressor operators and service technicians safe and secure. Doc. ServiceManual Page - 2

FILTER SAFETY AND INSPECTION METHODS The safe use and maintenance of high pressure systems is an important factor to ensure both operator and service personnel safety. Of prime importance is the compressor filter system that consists of the final oil/water coalescing filter and the purification chambers. As part of this system are the check valve after the final oil/water separator, the pressure holding valve and auto-drain system. All filters and separators that have a pressure change or cycle have to be checked for any sign of deterioration. The other important factor is ensuring the compressor avoids short operational cycles and shortens the service life of the components. The hour meter and the filter system cycle counter monitor this. Typically the cycle counter value should be about 4 to 4.5 times the number of operating hours. Filter systems are not designed for environments where chlorides or other contaminants may be in the ambient air. Some alloys used in the filter systems are more susceptible to stress cracking and corrosion. Preventative maintenance is critical to ensure operator safety. INSPECTION AND MAINTENANCE: 1. Ensure the filter service and cartridge changes are done every 6 months or when the filter cartridge life is reached. Service is required according to whichever comes first. The CSA standard calls for service every 6 months. 2. Service the check valve to make sure it is operating correctly and no short compressor operator cycles are occurring. 3. Verify the cycle counter number against the hour meter for the correct ratio of cycles per hours of operation. 4. Do a very careful cleaning of the final separator and filter chambers in advance of an inspection. 5. Inspect the separator relief valve threads for wear, do not install a separator cap using the relief valve. Annual testing and resetting of all relief valves on the final separator and fill stations is recommended. 6. Use a light and do a careful inspection of the oil/water separator and the filter chambers to look for any sign of surface cracking or corrosion. 7. If any sign of surface cracking or corrosion is evident the chamber must be removed from service and a new CRN certified chamber installed in its place. 8. Both the upper and lower caps must be removed in order to do a full and complete inspection of the chamber. 9. If anything unusual is found, send a photo to the factory for guidance prior to putting the item back in service. 10. All filter systems and the components within have a rated life and pressure cycle limit. This information is available from the specific manufacturer. Doc. ServiceManual Page - 3

Within the industry all pressure components are designed to a standard, in North America this is to the ASME code. Designs are normally done to normal and standard conditions. Subjecting pressure components to environmental chemicals in the air or temperatures below freezing can have a life reducing effect. This also applies to excessive pressure cycles. The larger the pressure change the shorter the component cycle life. It is recommended that filter component selection should have a design pressure rating above the system operating pressure. This improves the pressure component safety factor as well as increasing cycle life potential. Under the ASME code and CRN registration in Canada the aluminum alloy 6016-T6 is accepted for registration in all provinces and territories. Most pressure components have an operational life cycle which depends on the manufactures design, material and testing. Jordair rates all ASME grade CRN certified components for a life of 25 years or 75,000 pressure cycles. This is based on the final pressure equal to the operating pressure of the component. When the operating pressure is less than design or the pressure cycle is less than 50% of the operating pressure the cycle life will increase. Proper inspection, service and maintenance will help to keep these systems safe to operate and provide safety to the operational personnel. At Jordair our goal is to produce high quality products with the lowest cost of ownership and the highest level of operator and service personnel safety. PLEASE READ THIS SERVICE MANUAL AS IT CONTAINS INFORMATION TO KEEP YOUR BREATHING AIR COMPRESSOR SYSTEM OPERATING CORRECTLY AND SAFELY Additional information is found in the compressor and other system component operating manuals, please include this information for guidance in operating and service of your breathing air system. Doc. ServiceManual Page - 4

Model Serial no. Jordair Job no. Year of mfg. Date of commissioning Warranty period Phone # service hotline STAMP (Dealer) Date Sticker dealer data Doc. ServiceManual Page - 5

JORDAIR COMPRESSORS INC. TECHNICAL SPECIFICATION AND TEST REPORT SOLD TO: SHIPPED TO: SAMPLE Date Prepared: Sales Order No: Shipping: Air Application: JORDAIR SALESPERSON: Test Date: Crate: Ground Prepaid Collect Standard Export MECHANICAL SECTION BASE DATA TEST DATA BASE DATA TEST DATA Compressor Model: Compressor Serial No: Compressor: RPM Compressor Chrg - SCFM Suction: PSIG Inlet Filter Element No: 1st Stage: PSIG Separator Element No: 2nd Stage: PSIG 1st Filter Cartridge No: 3rd Stage: PSIG 2nd Filter Cartridge No: 4th Stage: PSIG 3rd Filter Cartridge No. 5th Stage: PSIG CO Monitor No: Oil: PSIG Moisture Monitor No: Low Oil PSIG Shutdown: Auto Drain No: High Temp.Shutdown - F Drain Solenoid No: Final Shutdown: PSIG Hour Meter No: Motor Pulley No: Max. Working: PSIG Motor Bushing No: Final Relief Valve Model Drive Belt Size: Final Relief Valve Compressor Oil - LITRES Set Pressure: PSIG Compressor Oil (Type): PMV Setting: PSIG Compressor Oil Level: System Leak Test At Operating PSIG: Compressor Oil Filter Autodrain Cycle Counter ELECTRICAL SECTION BASE DATA TEST DATA BASE DATA TEST DATA Motor Manufacturer: Control Volts Model: Control Current - AMPS Motor Base Type: PLC Model# H.P.: PLC Chip # Volts: Full Load Current - AMPS L1: L2: L3: Motor Phase: Hertz Serial No: Speed - RPM S.F. Doc. ServiceManual Page - 6

Filter labels, please note that all filters must be changed as a set. Separator First Filter Second Filter Third Filter Cart No. 1. 2. 3. 4. Cart Life Hrs. 1. 2. 3. 4. O-Ring No. 1. 2. 3. 4. Back-Up Ring No. 1. 2. 3. 4. Design Pressure PSI 1. 2. 3. 4. Test Pressure PSI 1. 2. 3. 4. COMMENTS: COMPRESSOR ASSEMBLED BY: COMPRESSOR INSPECTED BY: COMPRESSOR TESTED BY: DATE: DATE: DATE: DATE REQUESTED: SCHEDULED TO SHIP: Doc. ServiceManual Page - 7

Introduction form for the Operator By adding themselves to this list, the person that signs it confirms having been given a yearly introduction/instruction about the function and operation of the compressor unit. Furthermore they have been informed about the relevant safety rules and regulations (CSA) This form is to be kept safely with the other company documents (acceptance documentation, instruction manual) and is to be produced if requested by supervisory authorities (CSA/Worksafe, OH&S) Seqno. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Surname Name Place Date Signature Instructor s name/company Doc. ServiceManual Page - 8

Table of Contents 1. Check oil level, run up machine, confirm proper operation & shutdown pressure (Weekly, prior to operation) 5 2. Cartridge change every 6 Months as required 9 3. Every 500 Operating hours/ 6 months / actual operating hours: 13 4. Every 1000 Operating hours/ every 2 years / actual operating hours: 13 5. Every 1500 Operating hours/ every 3 years / actual operating hours: 13 6. Every 2000 Operating hours/ every 4 years / actual operating hours: 14 7. Every 2500 Operating hours/ every 5 years / actual operating hours: 14 8. Every 3000 Operating hours/ every 6 years / actual operating hours: 14 9. Every 3500 Operating hours/ every 7 years / actual operating hours: 15 10. Every 4000 Operating hours/ every 8 years / actual operating hours: 15 11. Every 4500 Operating hours/ every 9 years / actual operating hours: 15 12. Every 5000 Operating hours/ every 10 years / actual operating hours: 16 13. Filling hoses 16 14. Every 5 years (Pressure vessels) 17 15. Every 10 years (Pressure vessels) 17 16. Load cycles (Pressure vessels) 17 17. Maintenance schedule breathing air compressor units 18 18. Modifications 20 19. Replaced Parts 21 Doc. ServiceManual Page - 9

1. Check oil level, run up machine, confirm proper operation & shutdown pressure (Weekly, prior to operation) Name of person in charge Compressor operating hours* Refilled oil quantity Date * According to Hour Meter or other source Doc. ServiceManual Page - 10

Check oil level, run up machine, confirm proper operation & shutdown pressure (cont d) Name of person in charge Compressor operating hours* Refilled oil quantity Date * According to Hour Meter or other source Doc. ServiceManual Page - 11

Check oil level, run up machine, confirm proper operation & shutdown pressure (cont d) Name of person in charge Compressor operating hours* Refilled oil quantity Date * According to Hour Meter or other source Doc. ServiceManual Page - 12

Check oil level, run up machine, confirm proper operation & shutdown pressure (cont d) Name of person in charge Compressor operating hours* Refilled oil quantity Date * According to Hour Meter or other source Doc. ServiceManual Page - 13

2. Cartridge & Oil change (Every 6 months or as required) Name of person in charge Compressor operating hours* Air Test Date * According to Hour Meter or other source Doc. ServiceManual Page - 14

Cartridge change (cont d) Name of person in charge Compressor operating hours* Air Test Date * According to Hour Meter or other source Doc. ServiceManual Page - 15

Cartridge change (cont d) Name of person in charge Compressor operating hours* Air Test Date * According to Hour Meter or other source Doc. ServiceManual Page - 16

Cartridge change (cont d) Name of person in charge Compressor operating hours* Air Test Date * According to Hour Meter or other source Doc. ServiceManual Page - 17

3. Every 500 Operating hours / 6 months / actual operating hours: Maintenance work Done Date / Signature Compressor maintenance acc.to schedule chapter 16 Oil type change: Installation of maintenance kit..-a Breathing air test Miscellaneous 4. Every 1000 Operating hours / every 2 years / actual operating hours: Maintenance work Done Date / Signature Compressor maintenance acc.to schedule chapter 17 Oil type change: Installation of maintenance kit..-ab Breathing air test Auto-drain service & service/replace check valve 5. Every 1500 Operating hours / every 3 years / actual operating hours: Maintenance work Done Date / Signature Compressor maintenance acc.to schedule chapter 17 Oil type change: Installation of maintenance kit..-a Breathing air test Miscellaneous Doc. ServiceManual Page - 18

6. Every 2000 Operating hours / every 4 years / actual operating hours: Maintenance work Done Date / Signature Compressor maintenance acc.to schedule chapter 16 Oil type change: Installation of maintenance kit..-abc Breathing air test Auto-drain service & service/replace check valve 7. Every 2500 Operating hours / every 5 years / actual operating hours: Maintenance work Done Date / Signature Compressor maintenance acc.to schedule chapter 17 Oil type change: Installation of maintenance kit..-a Breathing air test Miscellaneous 8. Every 3000 Operating hours / every 6 years / actual operating hours: Maintenance work Done Date / Signature Compressor maintenance acc.to schedule chapter 17 Oil type change: Installation of maintenance kit..-ab Breathing air test Auto-drain service & service/replace check valve Doc. ServiceManual Page - 19

9. Every 3500 Operating hours / every 7 years / actual operating hours: Maintenance work Done Date / Signature Compressor maintenance acc.to schedule chapter 16 Oil type change: Installation of maintenance kit..-a Breathing air test Miscellaneous 10. Every 4000 Operating hours / every 8 years / actual operating hours: Maintenance work Done Date / Signature Compressor maintenance acc.to schedule chapter 17 Oil type change: Installation of maintenance kit..-abc Breathing air test Auto-drain service & service/replace check valve 11. Every 4500 Operating hours / every 9 years / actual operating hours: Maintenance work Done Date / Signature Compressor maintenance acc.to schedule chapter 17 Oil type change: Installation of maintenance kit..-a Breathing air test Miscellaneous Doc. ServiceManual Page - 20

12. Every 5000 Operating hours / every 10 years / actual operating hours: Maintenance work Done Date / Signature Compressor maintenance acc.to schedule chapter 16 Oil type change: Installation of maintenance kit..-ab Breathing air test Auto-drain service & service/replace check valve 13. Filling hoses Half-year Maintenance Work Date / Signature 1 Hose test according to TRG 402/8.2 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Doc. ServiceManual Page - 21

14. Every 5 years (Pressure vessels) Year Maintenance Work Date / Signature 5 Internal inspection of pressure vessels 10 15 20 15. Every 10 years (Pressure vessels) Year Maintenance Work Date / Signature 10 Water pressure test of pressure vessels 20 16. Load Cycles (Pressure vessels) Date Operating hours Load Cycles* Total Load Cycles * Load cycles are all dynamic pressure load changes in the pressure vessel; refer to operating manual Doc. ServiceManual Page - 22

17. Maintenance schedule breathing air compressor units Service and inspection acc. to calendar: Service and inspection acc. to operating hours: Change filter cartridge Change gaskets, o--rings included in maintenance kit additional gaskets, o--rings (not included in maintenance kit) Change intake and pressure valves at the latest Change intake filter cartridge Change piston liner Change sintered metal filters Change v--belt(s) Check automatic condensate drain adjustment, pressure loss Check cylinders, piston rings, change if required Check function of automatic condensate drain Check function of monitoring devices (if fitted) Check intake and pressure valves Check intermediate pressures and oil pressure Check oil level, oil change, oil filter change Check pistons Check piston liner Check pressure switch, pressure maintaining valve Check pressure vessels, record no. of load cycles Check temperature sensors, replace if required (if fitted) Check tightness of safety valves Check v--belt(s) and fan wheel Clean separator, empty condensate collecting tank Functional test, final inspection, test run Leak test Make test report, apply test stickers Service automatic condensate drain, check function, replace worn of defective parts Visual check of coolers The service interval starts from the beginning after the last maintenance work in this list Doc. ServiceManual Page - 23

1 Year 2 Years 3 Years 4 Years 5 Years 6 Years 7 Years 8 Years 500 1000 1500 2000 2500 3000 3500 4000 X X X X X X X As required As required X X X X X X X As required X X X X X X X X X X X X X X Doc. ServiceManual Page - 24

18. Modifications Designation / Description Part Numbers Date / Signature 19. Replaced Parts Doc. ServiceManual Page - 25

Designation Part Number Manufacturer s Part Number Old New Date / Signature Doc. ServiceManual Page - 26

Designation Part Number Manufacturer s Part Number Old New Date / Signature Doc. ServiceManual Page - 27

Dear Customer, We are happy to give you advice on any questions regarding your JORDAIR/BAUER compressor and help as soon as possible with any arising problems. JORDAIR COMPRESSORS INC. Toll Free: 1-800-940-8101 Phone: 1-604-940-8101 NAME DEPARTMENT EXT EMAIL Jeremy Rowand Managing Director 306 jrowand@uniserve.com Suki Gill Production Manager/Sales 307 suki@jordair.ca Jeff Forbes Technical Support/Training 315 jeff@jordair.ca NOTES: Doc. ServiceManual Page - 28