MEASURING WATER CONTENT IN COMPRESSED BREATHING AIR IN COMPLIANCE WITH EN 12021:2014 ULTRA-PRECISE AND ULTRA-RELIABLE WITH POLYMER TECHNOLOGY

Similar documents
B-DETECTION PLUS THE NEXT GENERATION MOBILE AND STATIONARY GAS MEASUREMENT SYSTEMS

FILTER CARTRIDGES THE GENUINE PRODUCT FOR YOUR PROTECTION AND THEIR SAFETY.

MINI-VERTICUS & VERTICUS THE NEXT GENERATION INDUSTRIAL COMPRESSORS FOR AIR, NITROGEN AND RARE GASES

MINI-VERTICUS & VERTICUS THE NEXT GENERATION INDUSTRIAL COMPRESSORS FOR AIR, NITROGEN AND RARE GASES

BAUER ACCESSORY SYSTEMS THE IDEAL ENHANCEMENT TO YOUR COMPRESSOR

BAUER PURE AIR THE CONCEPT FOR PURE BREATHING AIR

KOMPRESSOREN THE LUNGS OF YOUR COMPRESSOR THE BAUER P-FILTER SYSTEM. No matter whether you count on the purest breathing

Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment)

BAUER PURE AIR THE CONCEPT FOR PURE BREATHING AIR.

the new Ve- / VSE Range

B-NITROX SYSTEMS THE SAFE AND SECURE SOLUTION FOR PRODUCING AND COMPRESSING NITROX

THE NEW SP SERIES MAXIMUM CAPACITY MINIMUM FOOTPRINT

B-NITROX SYSTEMS THE SAFE AND SECURE SOLUTION FOR PRODUCING AND COMPRESSING NITROX

THE NEW SP SERIES MAXIMUM CAPACITY MINIMUM FOOTPRINT

deltaflowc deltaflowc Venturi or Probe

Our scope......your choice. An overview of the BAUER breathing air products

OPERATING INSTRUCTIONS

THE COMPACT LINE. Mobile power packs in convincing BAUER quality l/min 225 / 330 bar TOUGH RELIABLE WELL ESTABLISHED

POSEIDON EDITION COMPRESSORS FOR SPORTS & SAFETY APPLICATIONS

Niltox Breathing Air Purifier Range

OPERATION MANUAL NTF-15

AN INTRODUCTION TO COMPRESSED AIR QUALITY for BREATHABLE PURPOSES

OPERATION MANUAL NTF-60 Plus

STATIONARY UNITS FOR FIREFIGHTING KAP- / VERTICUS - RANGE

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

DSC 204 HP Phoenix. High-Pressure Differential Scanning Calorimetry up to 15 MPa Method, Technique and Applications

Recommendations on Checking Anaesthesia Delivery Systems

Materials Performance November Nitrogen generator inhibits corrosion within fire protection systems

Airtester HP for compressed air according to EN 12021

Instruction Manual. Pressure Vessels

STANDARDS FOR COMPRESSED GAS TESTING

HONG KONG COLLEGE OF ANAESTHESIOLOGISTS TECHNICAL GUIDINES RECOMMENDATIONS ON CHECKING ANAESTHESIA DELIVERY SYSTEMS

CO 2 and O 2 scrubbers

NGN Series nitrogen generator

Breathable Compressed Air

SAFETY TRAINING LEAFLET 06 CARBON DIOXIDE

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

HYPOXIC AIR FIRE PREVENTION SYSTEM TECHNICAL SPECIFICATION

BRITISH STANDARD BS 341-4: Transportable gas container valves. Part 4: Pressure relief devices ICS

Potter Nitrogen Generators

Preliminary filter Precision measurement chamber Flow meter Instruction manual

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

THE WATER-COOLED INDUSTRIAL RANGE


MMS Mercury Monitoring System for Natural Gas

...makes sense! Combined CO 2 /O 2 analyzers. Monitor your process in real-time: OUR CER. BlueSens.com

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

High Pressure Breathing Air Compressors

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

GAS INJECTION TECHNOLOGY GIT

Best Practice Guide, Servomex 2700

Columbus Instruments

Performance Overview calibration Laboratory EP Instruments Messtechnik und Kalibrierung GmbH

deltaflowc deltaflowc Venturi or Probe

Active Fire Prevention by Oxygen Reduction Systems

The affordable consumption counter for compressed air and gases R 3 /4 (DN 20)

DANGER WARNING IMPORTANT

AUK Environmental Sensor. Determining the refractive index of the air. AUK Environmental Sensor

Stationary High Pressure Compressor for Air and Breathing Air Compression. PE 400-VE in open version

HiQ laboratory gas generators.

Moisture levels in compressed breathing air. Prepared by QinetiQ Limited for the Health and Safety Executive 2006 RESEARCH REPORT 427

Working in Gas Hazard Areas

Workshop Compressors CLASSIC Series

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

Flow meter. bellow vaporizer. APL valve. Scavenging system

PERFORM Operating Document

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Product Range. High performance and economic high pressure solutions Made in Germany

Zebron Gas Management

LK-SX VOC. Application. Security Advice Caution. Notes on Disposal. Combined sensor mixed gas. Data sheet

Central System of Medical Gases

Mass Flow Controller (MFC) for Gases

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

Brownie s. Commercial Series NMCS-30 NMCS NW 1st Street, Fort Lauderdale, FL PH Fx

NITRON MG SERIES MEMBRANE NITROGEN GENERATORS

Traysealer T 100. Tray packaging in the smallest space

AMT-Ex Dewpoint Transmitter

Pneumatic high-pressure controller Model CPC7000

Unique solutions for medical oxygen

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

Industrial Compressor

1 Exam Prep NFPA 99 Health Care Facilities Questions and Answers (Plumbing Contractor)

Gas Control Systems. Product overview

EasyLine Continuous Gas Analyzers. So smart, they re simple

Gas mixtures. Individual solutions specifically for your application

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

Gas Control Systems. Product overview

deltaflowc deltaflowc Gas Massflowmeter Venturi- and Probe Type

Operation Manual. Pro 4 Warn Analyzer TM Rev 08.17

KOMPRESSOREN COMPRESSORS KAESER AIR SERVICE Our Services An Overview

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

HIGH-PRESSURE ACCESSORIES CATALOGUE

4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward

200 PSI HIGH-FLOW AIR SOURCE KIT

Transcription:

MEASURING WATER CONTENT IN COMPRESSED BREATHING AIR IN COMPLIANCE WITH EN 12021:2014 ULTRA-PRECISE AND ULTRA-RELIABLE WITH POLYMER TECHNOLOGY SPORTS & SAFETY

BAUER KOMPRESSOREN WHY PRECISE MEASUREMENT OF WATER CONTENT IS A MATTER OF LIFE OR DEATH. Breathing Air Standard EN 12021:2014 Limit values Oxygen (O 2) 21 % ± 1 % Carbon monoxide (CO) Carbon dioxide (CO 2) Oil* H 2O 5 ppm 500 ppm 0.5 mg/m³ 25 mg/m³ Excessive water content in breathing air causes cylinders to corrode from inside, resulting in material damage and reductions in wall thickness which will ultimately cause the cylinder to burst! In addition, excessive water content causes dangerous bacteria to proliferate. High water content is even hazardous on cold water dives. If the water content is not below the threshold specified in the standard, scuba regulators may freeze during dives in cold waters a potentially fatal occurrence. The moisture and the cold generated by the expanding air cause the breathing valve to ice up. The resulting uncontrolled air release may cause the air supply to fail altogether. Highly precise measurement of water content in compressed breathing air is a matter of life or death for firefighters as well as for divers. Because of this, the European Breathing Air Standard EN 12021:2014 exactly defines limits for the absolute water content. The limit value for water in compressed breathing air coming from the compressor is 25 mg/m³. *Limit value for breathing air, the limit value for Nitrox is 0.1 mg / m³

THE CHALLENGE: MEASURING WATER CONTENT IS A COMPLEX TECHNICAL PROCESS. Measuring water content in compressed breathing air presents a huge technical challenge that must take a wide range of parameters into account. The European Breathing Air Standard EN 12021:2014 standard defines the limit value for water content in terms of mg/m³ at atmospheric pressure. The physical measurement principles on which humidity sensors are based express either the dew point (in C) or relative humidity (in %). Conversion of the measure value to the displayed value, expressed as absolute water content (in mg/m³), is pressuredependent and is only defined for low pressure levels. This conversion is not backed by scientific evidence for higher pressures, so that pressures of > 200 bar involve high levels of inaccuracy. In addition, the variable parameters of pressure and temperature at the high-pressure outlet impact negatively on measurement precision. BAUER KOMPRESSOREN therefore chose the atmospheric method for measuring the water content of breathing air, with the aim of achieving measurements of the maximum precision and reliability. BAUER S SOLUTION: DEW POINT SENSORS INCORPORATING POLYMER TECHNOLOGY Polymer sensors have extremely rapid response times. They react within a very short time unlike the aluminium oxide sensors that are prevalent in compressed-air technology, which have response times of several hours from ambient humidity to dry breathing air. Low-price mass-market products in this category are unable to measure the extremely low water content levels defined by the Breathing Air Standard. BAUER uses sophisticated add-on technologies, such as automatic offset calibration of polymer sensors, to deliver ultra-precise measurements of even low levels of water content. Only a few manufacturers have this expertise. BAUER S QUALITY FACTOR NO. 1 Lower-cost aluminium oxide sensors have extremely long response times, and are thus unsuitable for measuring extremely low water content levels. The dew point sensors with polymer technology used by BAUER KOMPRESSOREN respond extremely rapidly. BAUER s polymer sensors enable even low levels of water content to be measured accurately, based on automatic offset calibration.

MEASURING WATER CONTENT THE EXPERT SYSTEM FOR STANDARD- COMPLIANT MEASUREMENT B-DETECTION PLUS ENSURES THE CORRECT MEASUREMENT ACCORDING TO THE EUROPEAN BREATHING AIR STANDARD EN 12021:2014 1 6 7 2 3 4 5 1. High-pressure compressor 2. B-DETECTION AIRBOX 3. Data cable 4. Gas hose 5. High-pressure piping 6. B-DETECTION PLUS s 7. External filling panel Measuring water content in compressed air is a science in itself even with the right sensors. The extremely high partial pressure difference between compressed air and air under atmospheric conditions causes ambient moisture to diffuse into pipelines, and thus also into the measurement cell of the dew point sensor. When the compressor is not in operation, the water molecules are deposited in the pipes, the measurement cell and the dew point sensor. When the compressor is restarted after longer downtimes, the system must first be dried by flushing it with compressed air to ensure compliance with the limits required by the European Breathing Air Standard EN 12021:2014. It is recommended to refrain from filling breathing air cylinders until the air water content has returned to below the limit stated in the European Breathing Air Standard EN 12021:2014. Instead, the moist air can be released to the outside through a purging valve. We recommend our optional automatic purging system. NOTE ON FIRST-TIME INSTALLATION OF A B-DETECTION PLUS SYSTEM During first-time installation, purging times of up to 3 hours may be necessary to remove moisture from the entire piping system. In general, a purging time of 30 minutes must be calculated for first-time installation

BAUER KOMPRESSOREN RECOMMENDATIONS AND INFORMATION To keep this drying period and associated purging of moisture-laden air as brief as possible in practice, we recommend the following actions when installing and operating our B-DETECTION PLUS gas measurement systems: Ensure the system pressure between the filter housing and the gas extraction unit is as high as possible (> 200bar) while the compressor is inoperative. This means that the piping between the filling panel or storage system should not be vented after filling is complete. Use stainless-steel piping to connect the compressor and storage unit or other air extraction devices. Keep screw connections and gaskets to a minimum. The following point must be in addition observed during installation of standalone models: The length of piping between the compressor filter housing and the gas extraction unit (AIRBOX) should be as short as possible (max. 3 metres). When these actions are observed, the following purging times after compressor downtime can be assumed to apply: Downtime Purging time 1 days < 5 min 3 days < 15 min 7 days 30 min Table 1: Purging times for various compressor downtimes Standalone version: B-DETECTION PLUS s RECOMMENDATION REGARDING FILTER CARTRIDGE CHANGES The filter cartridge must be changed if the absolute humidity limit value of 25 mg/m³ or the VOC limit value of 0.5 mg/m³ are exceeded. During the compressor start-up phase, ensure that the water content level falls below the limit value during the purging times given in Table 1. If this does not happen or if the value rises again after the start-up phase, change the filter cartridge. For compressor systems with longer downtimes, we recommend the additional installation of a SECURUS system for direct monitoring of filter cartridge saturation. BAUER S QUALITY FACTOR NO. 2 The dew point sensor of the B-DETECTION PLUS guarantees long-term stability, even for low water content levels. Given this, calibration at 2-year intervals is sufficient to ensure high-precision measurement.

ARE YOU INTERESTED IN OUR PRODUCTS? CONTACT US WE ARE HAPPY TO PROVIDE INFORMATION AND ASSISTANCE. BAUER KOMPRESSOREN GmbH Stäblistr. 8 81477 Munich, Germany Tel. +49 (0) 89 78049-0 Fax +49 (0) 89 78049-167 info@bauer-kompressoren.de bauer-kompressoren.de MEASURING WATER CONTENT EN N43020 12.2017 Technische Änderungen vorbehalten