Aseptic Techniques. Techniques for Sterile Compounding. Pharmacy Technician Training Systems Passassured, LLC

Similar documents
TEV-TROPIN [somatropin (rdna origin) for injection] 5 mg & 10 mg

RECOMBINATE. [Antihemophilic Factor (Recombinant)] (For intravenous use only)

RECONSTITUTION AND ADMINISTRATION INSTRUCTIONS FOR HEALTHCARE PROFESSIONALS

RECONSTITUTION AND ADMINISTRATION INSTRUCTIONS FOR HEALTHCARE PROFESSIONALS. Hereditary Angioedema

PREPARATION AND SELF-ADMINISTRATION INSTRUCTIONS FOR PATIENTS

Aseptic processing. the starting material to the finished product, should be controlled by Validation Control of the aseptic process

Mixing Methacholine Dilutions for Bronchoprovocation Challenge Testing

Patients Guide for Self Administering Intravenous Antibiotics General points

PREPARATION AND SELF-ADMINISTRATION INSTRUCTIONS FOR PATIENTS

1.0 PURPOSE The purpose of this procedure is to describe the use of basic aseptic technique.

Dilution Sequence Protocol

STANDARD OPERATING PROCEDURE ADVANCED INTRAVENOUS TRAINING ARM (S )

Dilution Sequence Protocol

Aseptic Vial and Syringe Filling Narlin B. Beaty, Ph.D. Adelaide Nye

Dilution Sequence Protocol

Before you start sampling, be sure to read

STANDARD OPERATING PROCEDURE

COLLECTION OF BLOOD. Types of patients

Specimen Collection. Lead Screen Filter Paper Testing Dried Blood Spots (DBS) Laboratory Services February 2017

Air-Mate High Efficiency Powered Air Purifying Respirator (PAPR) Staff Training Module

PERFORMANCE OF A FINGERSTICK

<788> PARTICULATE MATTER IN INJECTIONS

Venepuncture. Clinical Skills. Venepuncture. Dr Brian Jenkins (Clinical Skills Lead) Sian Williams (Clinical Skills Manager)

CTG Certification Protocol -- Version 3.0 SUMMARY

3. This solution retains potency for 2 8 hours at room temperature after reconstitution.

CHAPTER 10 Reconstitution of Powdered Drugs

PARTICLE SPACING PART 1

COMPOUNDING WITH HAZARDOUS DRUGS

Making Life Easier Easypump II

C O L O G Y. New. g u O N. l o t a C a. The high security connection

Vertebrate Animal Biosafety Level 1 Criteria

Skills & Scenarios 81

PREPARING GAS SAMPLES IN LARGE PLASTIC SYRINGES

CENTRAL IOWA HEALTHCARE Marshalltown, Iowa

IVIG Educational Presentation

Varithena Delivery System Instructions for Use

Webinar Expert Module 1: Garment Logistics and Gowning. Dupont September GOP-Innovations

Veterinary Science Handling and Restraining Practicum. Restraint of the Cat for Cephalic IV Catheter Placement

PIMA MEDICAL INSTITUTE RADIOGRAPHY PROGRAM ARRT GENERAL PATIENT CARE COMPETENCIES CPR

Procedure 85 Attaching The Humidifier To The Oxygen Flow Meter Or Regulator. Procedure 86 Administering Oxygen Through A Nasal Cannula

Decontamination after Inadvertent Release

Port - Body in a Box User s Manual

The NAMIC Dream Kit. Single Operator Control. Reduce Contrast Waste. Less Force to Inject. Compensator * Manifold. How the Compensator Manifold Works:

Varithena Delivery System Instructions for Use INSTRUCTIONS FOR USE Please read the Product Monograph before using the product.

Assisting with Insertion. Care of Intraspinal Catheters

Monosed ESR Non-Vacuum Tube USER S MANUAL

Skills & Scenarios 81

HEALTH SERVICES CODE A.6 CATEGORY: RN - SNP

Experiment 18 Properties of Gases

Basic Flows in a Microfluidic Device

Biological materials manipulated in the laboratory: Bacteria Virus Protozoan

TECHNICAL BULLETIN. TriControls. Control Materials for Liquid QC and Calibration Verification

Summary of BCCA Pharmacy Practice Standards for Hazardous Drugs

Title of Manual: Specimen Collection Document Number: GPA To provide the proper collection protocol for Candida Vaginitis testing.

25/04/56. LTC Carmen A. Bell Chief, Laboratory Operations USAMC-AFRIMS

Tex-414-A, Air Content of Freshly Mixed Concrete by the Volumetric Method

PEDIATRIC INJECTABLE TRAINING ARM SIMULATOR LF00958U INSTRUCTION MANUAL

INJECTING GUIDE By Pat Magee

HemoCue Hb Procedure Template

BIOSAFETY SELF AUDIT PRINCIPAL INVESTIGATOR/PERMIT HOLDER: CONTAINMENT LEVEL: 1 2 (Shaded) RISK GROUP: 1 2 AUDIT TO BE COMPLETED BY (DATE):

limbsandthings.com Advanced Venepuncture Arm User Guide For more skills training products visit Limbs & Things Ltd.

CCM Approval: IACUC Approval:

PREPARATION AND PROPERTIES OF ATMOSPHERIC GASES I: Carbon Dioxide and Oxygen

Parts identification:

TJF-Q180V Cleaning and Disinfection Checklist

FIELD TIP SHEET. Mark the bag with black permanent marker before filling it with water.

Safety Huber Needles

The Butterfly. Steep Trendelenburg Gel Bean Bag Positioner USE & CARE GUIDELINES DAVID SCOTT COMPANY

New. The high security connection

TJF-Q180V Cleaning and Disinfection Checklist

A designated area will have been assigned for all blood specimens to be taken. All blood should then be taken in that area only.

Lightweight II S.E. Improved Design & Acoustics. Stethoscope

DIAGNOSTIC CARDIOLOGY

STANDARD OPERATING PROCEDURE

Standard. Bag & Stand Advanced Venepuncture Arm. Light. Part No: Brown. Part No: Black. Part No: 00442

ARTERIAL MONITORING. Final Approval: VP Operations, Chief Nursing Officer Distribution: ICU, PACU POLICY:

Shukla Medical. TITLE: Manual Surgical Orthopedic Instruments Recommendations for Care, Cleaning, Maintenance and Sterilization

LABORATORY TECHNIQUES. Pouring Liquids

FMEA What s the Worst That Could Happen?

SALX. Interpretation Guide. Salmonella Express System

Presented by ARAMSCO

Clinician Guide. Baxter Elastomeric Devices. Promoting patient-centric care

5-Way Test Kit. To test for: Chlorine Bromine ph Alkalinity Acid Demand. Regular Testing Helps Maintain a Clean, Clear Sparkling Pool.

Personal Protective Equipment (PPE) Hazard Assessment Certificate Instructions

3M Liqui-Cel EXF-4x13 and 4x28 Series Membrane Contactors

Blood Pressure Monitoring: Arterial Line

Transfer Procedures. By the end of this chapter, you will be able to: The Transfer Process. Chapter 12

USP <797> LABELING ESTABLISHING BEYOND-USE DATES AND IN-USE TIMES

Part II. Under Construction Station Instructions. Lab Station A - Blue Print: There is O 2 Here!

BASIC KNOWLEDGE OF LABORATORY FIRST AID

Chapter 40. Fluid, Electrolyte, and Acid Base Balance. Procedures Checklist INTRAVENOUS THERAPY. Procedure 40.1: Starting an Intravenous Infusion

ETT Olfactometer: Getting started guide 2013a. ETT Olfactometer quick start

Articulating Legs with Intraosseous Infusion Simulator LF03840U Instruction Manual

Standard. Standard. Venepuncture Arm. Light. Part No: Brown. Part No: Black. Part No: 00332

Transfusion equipment for medical use. Part 4: Transfusion sets for single use, gravity feed

ANALYTICAL SERVICES MAHANGA HOLDINGS LTD

HemoCue Training and Education Program. Capillary Sampling. Hemoglobin. USPRO1 Rev 1 3/03. Training and Education Program 2003 HemoCue, Inc.

Bag It, Move It, Leave It or Report it?

Module 14: Blood Collection and Handling DBS

INSTRUCTIONS FOR USE (US)

Transcription:

Aseptic Techniques Techniques for Sterile Compounding Pharmacy Technician Training Systems Passassured, LLC

Aseptic Techniques, Tech for Sterile Compounding PassAssured's Pharmacy Technician Training Program Aseptic Technique Techniques for Sterile Compounding Click Here for Glossary Index! Click Here to Print Topic Help File,.pdf (Internet Access is Required for this Feature) Prior to Compounding Remove rings, watches, and bracelets (ideal for bacteria) Wash hands and forearms to the elbows with appropriate germicidal agent. This must be done for 30 seconds. Working in a Laminar Air Flow Hood It is recommended by most policies and procedures that the laminar flow hood should be running for at least 30 minutes prior to use. Disinfection Disinfection should be done at least at the beginning and end of each shift, hourly during operation, and after spills or known contamination. Use parallel sweeping motions from the back of the hood to the front, not circular motions Placement of Items to Prepare Avoid working over open containers or preparations to prevent contaminates falling into the preparation area. Non-Essential Items Do not introduce items that are not essential for the preparation process into the hood (i.e., p2

paper, pencils, etc.). Work Area Utilized Work at least six inches within the hood for maximum benefit Avoid working close to the outer edge of the hood as the product may be contaminated. Waste Disposal Hazardous waste buckets should be accessible. Needles used in IV preparation should be disposed in a Sharps Container. Prevent Shadowing Make sure you block areas of preparation that must remain sterile from the air flow, so that there is no contamination. One must be careful not to place hands, equipment, vials, etc., in front of critical areas of preparation products. "Dead spaces" are created behind objects in the airflow: Areas on products that must remain sterile should never be placed in dead spaces. Location of Sterile Room Sterile product preparation room should be free of dust, especially cardboard as a source of particles. Should be kept away from common routes of personnel traffic. Personnel Precautions While laminar air flow hoods prevent airborne contamination, they do not guarantee a sterile product. Use precautions to minimize contamination in the product preparation area. p3

Use strict aseptic technique to avoid introduction of contaminants into the hood. Withdrawing Liquid from a Vial Remove the cover of the vial and wipe rubber surface with an alcohol swab. Withdraw the same volume of air into the syringe as the volume of drug intended to be withdrawn. Uncap the needle, and insert it with the bevel side up at a 45 degree angle. NOTE: Once the rubber surface has been penetrated, the syringe may then go into the rest of the vial straight on, prevent coring (cutting out part of the rubber stopper). Inject the Sterile Air in the Syringe into the Vial This creates pressure inside of the vial forcing the liquid out. Keeping the needle in the vial, invert the vial and hold it with one hand to control the syringe. Pull back the plunger of the syringe to withdraw the liquid. Needle should penetrate the rubber closure, but not go much further into the vial so that all medication can be withdrawn. Once the medication has been withdrawn, tap the syringe to make all of the bubbles go to the top of the syringe. Pull down on the plunger to remove the bubbles and then push the plunger back up to the desired volume. Remove the bubbles for accurate measurement. Remove needle from vial and recap the syringe with a Luer-tip cap. (Check with your institution and JCAHO requirements for the handling and disposal of needles.) Withdrawing Liquid from an Ampule p4

Ampules are containers made entirely of glass. They are broken at the neck, which is usually pre-weakened. Hold the ampule upright and tap the top to remove any liquid trapped in this area. Wipe the neck of the ampule with an alcohol swab to reduce contamination. Wrap the gauze pad around the neck when breaking it open to reduce the chance of cutting fingers and preventing glass fragments. Grasp the ampule using the thumb and index fingers of both hands on each side of the ampule neck. Snap the ampule quickly, breaking it away from yourself, and the filter to avoid glass fragments. Tilt the ampule and insert the filter needle or filter straw attached to the syringe. Avoid touching the neck of the ampule with the needle. A filter needle or filter straw always must be used when withdrawing liquid from ampules to prevent glass particles from being introduced into the product, and thus, the patient. To remove liquid, hold the ampule in one hand and the syringe in the other. Push the plunger back with the thumb of the hand holding the syringe to the desired volume. Before injecting contents of the syringe into a parenteral product, be sure to remove the filter straw or filter needle, and replace it with a regular needle. Removal of filter needle before injection is necessary so that the filtrate will not be injected into the product. Hold the syringe upright, tap out bubbles, and push the plunger up to the desired volume. Reconstituting a Sterile Powder in a Vial For drugs in a vial in powder form, it is necessary to reconstitute with a suitable diluent, which will be specified in the vial or package insert. p5

Sterile Water D5W NS (normal saline 0.9% NaCl) Follow the steps described previously for entering a vial. Inject diluent and tilt or roll until the drug is dissolved. Do Not Shake. Introduce Liquid into a Plastic IV Bag Remove plastic IV bag from the outer wrap and inspect for leaks, tears, or particulates. Swab the rubber port of the bag with an alcohol swab, being careful not to block the airflow from the port. Inside of the medication port is a diaphragm: Needle must be at least ½" to penetrate the diaphragm so that liquid drug will reach IV solution Insert the needle straight on to avoid puncturing sides of the plastic bag. Inject contents of the syringe, and remove the needle from the port. Mix the final product by inverting the bag and squeezing the port to be sure that all of he medication is diluted in the solution and has not been retained in the diaphragm. Introducing Liquid into a Glass Intravenous Bottle Remove protective cover from the IV bottle and swab the rubber closure with an alcohol swab. Inject the contents of the syringe into the rubber entry port, using the technique described previously. Some glass IV bottles are created with a vacuum which "pulls" the medication from the syringe into the bottle. After withdrawing the syringe, place a protective covering over the injection site to prevent contamination or tampering. p6

Places to Avoid Touching or Blocking Air Flow During Preparation Portions of equipment, containment, and devices which come into contact with the sterile product: Needle shaft Inside of needle hub Syringe plunger Tip of syringe barrel that attaches to needle hub Surface of rubber entry on vial, bottle, or bag Visual and Quality Control Inspection of Parenteral Products Check for particulate matter, crystals, and precipitation. Isotonicity is important because the injectable solution needs to be isotonic with the blood. Acid content or the ph of the solution is an important characteristic. Color and clarity of an IV is an important characteristic. Hold product in front of well illuminated light or dark background to detect particles TPN's that contain lipid emulsion are not clear, therefore precipitation cannot be seen. Components of a Parenteral Product Label Solution name, lot number, and volume (note this may be part of the manufacture's label) Patient name, record number, and room number Bottle/bag sequence number Additive names, strengths, and quantities Date of preparation and initials of preparer Expiration and initials of preparer Expiration time and date Flow rate Administration: time, date, and by whom Appropriate auxiliary labels p7

Pass Assured, LLC, Pharmacy Technician Training Systems Copyright Pass Assured, LLC, Web Site - http:// -o- p8