Masoneilan* Model 78-80H & 08-80H Transfer Valves

Similar documents
Masoneilan* Model 78-80S & 08-80S Transfer Valves

Masoneilan* 78 Model Air Filter Regulator

GE Oil & Gas Model. Masoneilan* Air Lock-up Valve Instruction Manual. GE Data Classification : Public

Becker* Model FD-1500 Filter/Dryer

Masoneilan* Series Self Operating Pressure Regulators

Masoneilan * DSH * Series Desuperheater

Mooney* Series 21 Regulator

173 Series Self-Operating Pressure Regulators

Mooney* Flowgrid* Slam Shut* 1 Valve

CSA Sample Draw Aspirator Adapter Operator s Manual

1566 & Models

RK-IR Sample Draw Aspirator Adapter Operator s Manual

Installation Instructions JATCO Environmental Protection Tank Model J-5000CX

1805 Series Relief Valves

RK LEL Sample Draw Aspirator Adapter Operator s Manual

Instruction Manual 742 5/1/2009. Eclipse Ratio Regulators ES Series Version 1

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

Installation Instructions JATCO Environmental Protection Tank Model J-7000

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

VBL Volume Booster. Features. D103393X012 January 2013

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

VOLUME BOOSTER RELAYS YT-300 / 305 SERIES

Putting You In Control. Model 4411 Electropneumatic Transducer. Instruction Manual ES /10

CF-SERIES HIGH FLOW REGULATORS

64 Series Pressure Reducing Regulators

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Interface Devices, Inc. Hydraulic Mini Mule

Operation Manual Air Saver Unit ASV5000 Series

Instruction Manual No. 742, 8/98

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

No.IL02-OM00011-A PRODUCT NAME LOCK UP VALVE. MODEL/ Series IL201 IL211

Fisher Lever Lock Handlever Actuators for POSI SEAL A81 Rotary Valves

Model Visit our website at:

DEEPSEA. Power & Light. Micro SeaLaser. Operator s Manual Ruffin Road San Diego, CA USA T: (858) F: (858)

Lock Up Valves YT-400, YT-405 USER'S MANUAL

Vacuum Saving Valve Series ZP2V How to Order ZP2V A5 03 Connection thread symbol for the pad Male thread connection Symbol Thread Applicable fixed ori

Series IRV1000/2000/3000

Instruction Manual. CG16K Barometrically Compensated Capsule Dial Gauge. CG16K Capsule Dial Gauge, 0 to 25 mbar

92831 TEL: (714) FAX:

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

CLEMENTS. ANA Oxygen Regulator with Yoke Connector. User Manual. Manual No. ANA Issue 1

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

DS06D,G Dial Set Pressure Regulating Valve

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

PP-1, PP-1W, PP-2, & PP-3

Speed control assembly model A-1

Power Valve: Precision Regulator. High precision, large capacity relief regulator

Fisher 2625 and 2625NS Volume Boosters

D05T Compact Design Pressure Regulating Valves

LOCK UP VALVES YT-400/405/430/435 SERIES

Yoke Block Instruction Manual

Fisher Lever-Lock Handlever Actuators for POSI-SEAL A81 Rotary Valves

Installation, Operation, and Maintenance Manual

AWG Fittings LLC. Pressure Relief Valve Up to 250 PSI. Product Number Read this instruction manual before use.

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

SANP ACTING RELAYS YT-520/525/530 SERIES

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

1301 Series High-Pressure Regulators

RGC-IR Remote Gas Calibrator for IR400

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES

AIR DISTRIBUTOR. PART NUMBER (Including, but not inclusive) AD28483-_ALB, AD28563-_ALB, AD36097-_ALB, AD36098-_ALB, AD28485-_ALB

U S E R M A N U A L AIR FLOWMETER. MODELS: 1MFA2001 (shown) 1MFA9001 CAUTION. ISO Certified

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

Model 9201E Tempered Water Blending System

Product Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction

Pulse Blow Series Offers Energy Savings for Air-blowing Procedures

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

1305 Series Pressure Reducing Regulators

1805 Series Relief Valves

GM-7000 Series CE Approved Gas Control Valve

Standard Specifications

Pressure Relief Valve Instruction Manual

RC 195 Receiver-Controller

PCS 340 Core Saturator : 115 Volt : 230 Volt. Instruction Manual

SERVICE LETTER WARRANTY CONDITIONS FOR ROTAX

Tri-Safem Model I1 Regulator. INSTRUCTIONS and PARTS

Accu-Tab PowerBase 3012AT by Axiall Corporation

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

INSTRUCTIONS PARTS LIST

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor

Types 749B and R130 Changeover Manifolds

APCO ARV CLEAN WATER AIR RELEASE VALVES. Model 50A

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

30T A/Manual Hydraulic Shop Press

Installation, Operation, and Maintenance Manual

MODEL CALIBRATION GAS DELIVERY SYSTEM

DEEPSEA POWER & LIGHT. Operator s Manual. SeaLite Six. Original Instruction Ruffin Road San Diego, CA USA

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN

Pressure Sensing Valve - Model 4023

Paintball Marker. User s Manual. 530 South Springbrook Road Newberg, OR 97132

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

Fisher DVI Desuperheater Venturi Inline

Industrial Filter. FGD series

Pressure-limiting valve and pre-load valve type MVG, MVE and MVP

Transcription:

GE Oil & Gas Masoneilan* Model 78-80H & 08-80H Transfer Valves Instruction Manual GE Data Classification: Public

THESE INSTRUCTIONS PROVIDE THE CUSTOMER/OPERATOR WITH IMPORTANT PROJECT-SPECIFIC REFERENCE INFORMATION IN ADDITION TO THE CUSTOMER/OPERATOR S NORMAL OPERATION AND MAINTENANCE PROCEDURES. SINCE OPERATION AND MAINTENANCE PHILOSOPHIES VARY, GE (GENERAL ELECTRIC COMPANY AND ITS SUBSIDIARIES AND AFFILIATES) DOES NOT ATTEMPT TO DICTATE SPECIFIC PROCEDURES, BUT TO PROVIDE BASIC LIMITATIONS AND REQUIREMENTS CREATED BY THE TYPE OF EQUIPMENT PROVIDED. THESE INSTRUCTIONS ASSUME THAT OPERATORS ALREADY HAVE A GENERAL UNDERSTANDING OF THE REQUIREMENTS FOR SAFE OPERATION OF MECHANICAL AND ELECTRICAL EQUIPMENT IN POTENTIALLY HAZARDOUS ENVIRONMENTS. THEREFORE, THESE INSTRUCTIONS SHOULD BE INTERPRETED AND APPLIED IN CONJUNCTION WITH THE SAFETY RULES AND REGULATIONS APPLICABLE AT THE SITE AND THE PARTICULAR REQUIREMENTS FOR OPERATION OF OTHER EQUIPMENT AT THE SITE. THESE INSTRUCTIONS DO NOT PURPORT TO COVER ALL DETAILS OR VARIATIONS IN EQUIPMENT NOR TO PROVIDE FOR EVERY POSSIBLE CONTINGENCY TO BE MET IN CONNECTION WITH INSTALLATION, OPERATION OR MAINTENANCE. SHOULD FURTHER INFORMATION BE DESIRED OR SHOULD PARTICULAR PROBLEMS ARISE WHICH ARE NOT COVERED SUFFICIENTLY FOR THE CUSTOMER/OPERATOR'S PURPOSES THE MATTER SHOULD BE REFERRED TO GE. THE RIGHTS, OBLIGATIONS AND LIABILITIES OF GE AND THE CUSTOMER/OPERATOR ARE STRICTLY LIMITED TO THOSE EXPRESSLY PROVIDED IN THE CONTRACT RELATING TO THE SUPPLY OF THE EQUIPMENT. NO ADDITIONAL REPRESENTATIONS OR WARRANTIES BY GE REGARDING THE EQUIPMENT OR ITS USE ARE GIVEN OR IMPLIED BY THE ISSUE OF THESE INSTRUCTIONS. THESE INSTRUCTIONS ARE FURNISHED TO THE CUSTOMER/OPERATOR SOLELY TO ASSIST IN THE INSTALLATION, TESTING, OPERATION, AND/OR MAINTENANCE OF THE EQUIPMENT DESCRIBED. THIS DOCUMENT SHALL NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN APPROVAL OF GE. 2 GE Oil & Gas 2017 General Electric Company. All rights reserved.

Table of Contents 1. Overview 5 2. Specifications 5 3. Numbering System 5 4. Mounting 6 5. Adjustment 6 6. Maintenance 7 2017 General Electric Company. All rights reserved. Masoneilan Model 78-80H & 08-80H Transfer Valves Instruction Manual 3

Safety Information Important - Please read before installation These instructions dealing with M a s o n e i l a n Model 78-80H and Model 08-80H transfer valve contain DANGER, WARNING, and CAUTION labels, where necessary, to alert you to safety related or other important information. Read the instructions carefully before installing and maintaining your control valve. DANGER and WARNING hazards are related to personal injury. CAUTION hazards involve equipment or property damage. Operation of damaged equipment can, under certain operational conditions, result in degraded process system performance that can lead to injury or death. Total compliance with all DANGER, WARNING, and CAUTION notices is required for safe operation. This is the safety alert symbol. It alerts you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, could result in serious injury. About this Manual The information in this manual is subject to change without prior notice. The information contained in this manual, in whole or part, shall not be transcribed or copied without GE s written permission. Please report any errors or questions about the information in this manual to your local supplier. These instructions are written specifically for the Model 78-80H and Model 08-80H transfer valve, and do not apply for other valves outside of this product line. Warranty Items sold by General Electric are warranted to be free from defects in materials and workmanship for a period of one year from the date of shipment provided said items are used according to GE recommended usages. GE reserves the right to discontinue manufacture of any product or change product materials, design or specifications without notice. Note: Prior to installation The valve must be installed, put into service and maintained by qualified and competent professionals who have undergone suitable training. All surrounding pipe lines must be thoroughly flushed to ensure all entrained debris has been removed from the system. Under certain operating conditions, the use of damaged equipment could cause a degradation of the performance of the system which may lead to personal injury or death. Changes to specifications, structure, and components used may not lead to the revision of this manual unless such changes affect the function and performance of the product. Indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury. When used without the safety alert symbol, indicates a potentially hazardous situation which, if not avoided, could result in property damage. Note: Indicates important facts and conditions. 4 GE Oil & Gas 2017 General Electric Company. All rights reserved.

1. Overview The Model 78-80H is a transfer valve combining a pilot valve of the floating ball type and three-port valve into one unit and is a high-capacity three-way transfer valve of a set pressure regulating type. The other model, 08-80H, is the same as the 78-80H except that a pilot valve is not combined and is the so-called three-way transfer valve. If several 78-80Hs are needed, one 78-80H can be installed, connecting 08-80Hs to it by mating the pilot outlet pressure ( SIG.OUT ) on the 78-80H to SIG on the 08-80H to simplify piping and achieve transfer. The structures of these models are shown on pages 8 and 9. 2. Specifications Maximum Operating Pressure Item Standard Option Body 1.72 MPa - Signal 1.03 MPa - Set Pressure 100~700 kpa - Hysteresis 34 kpa or less - Cv Value IN OUT 4.5 - OUT EXH. 5.0 - Connection IN OUT EXH. Ports Rc1/2 NPT1/2 SIGNAL Port Rc1/4 NPT1/4 Operating Temperature Range -30~+83 C 0~100 C Housing Material Aluminum Alloy 316L Stainless Steel (1) (1) When the housing material is 316L stainless steels, the connections are NPT. 3. Numbering System 1 st 2nd 3rd 4th 5th 8-8 0 H - Suffix A Suffix B 1 st - 4 th 5 th Suffix A Suffix B Product Capacity Housing Material 78-80 Set Pressure Regulating Three-Way Transfer Valve 08-80 Three-Way Transfer Valve H High Capacity Blank -30~83 Blank Aluminum Alloy -H 0~100-316L 316L Stainless Steel 2017 General Electric Company. All rights reserved. Masoneilan Model 78-80H & 08-80H Transfer Valves Instruction Manual 5

4. Mounting Clean all the pipes before mounting the valve and completely remove dust, scale and other foreign matter. Mount the transfer valve as close to the actuator as possible and let air flow toward the IN and OUT marks located on the lower side of the body. Two EXH ports are provided. Use one EXH port and put a blind plug in the other unused port. When using the valve as a lock-up valve, put a blind plug each in the two EXH ports. Two air connection ports to the pilot part are provided on the 78-80H, one being marked SIG and the other, SIG OUT. Connect the signal pressure to the port marked SIG. Use SIG.OUT for sending signal to the 08-80H when it is also mounted. The transfer valve functions to cut off IN and to connect OUT to EXH when the signal pressure lowers below the set pressure or is reduced to zero. Do not use signal pressure at air pressure exceeding 1.03Mpa (10.5kgf/cm2). Feeding signal pressure from near the IN side of the body will cause fluctuations in signal and air pressures due to the large air valve capacity. This may cause hunting. 5. Adjustment The necessary settings of the transfer valve are generally performed at the factory and adjustment of it is not required. If, however, the setting pressure needs to be adjusted, make adjustment as follows: a) Loosen the lock screw (26) and turn the adjust knob (17) counterclockwise to release the compression of the spring (25). b) Turn the adjust knob (17) one or two turns clockwise to tighten it and to slightly compress the spring (25). c) Connect air pressure to IN marked on the body to check whether the body is open or closed. Then connect the pressure gauge and pressure reducing valve to the signal pressure connection port SIG. d) Apply supply air pressure and set the air pressure to SIG at specified pressure by operating the pressure reducing valve while watching air pressure to SIG on the pressure gauge. e) Turn the adjust knob (17) clockwise until air pressure no longer leaks through OUT marked on the body. f) This will cut off IN, and OUT and EXH will open in the transfer valve. g) Lastly, fasten the lock screw (26) and fix it. 6 GE Oil & Gas 2017 General Electric Company. All rights reserved.

The ball (21) temporarily floats to transfer the pilot part and the valve emits a light beat tone when the set and signal pressures become the same. This is not an anomaly. The beating sound will stop when the transfer ends. 6. Maintenance Rubber is used in various parts of the transfer valve. Periodical exchange of this rubber every five years is recommended. Your valve will be checked and repaired at our factory if a check or a repair becomes necessary. Contact our agent or sales office for a check or a repair. 2017 General Electric Company. All rights reserved. Masoneilan Model 78-80H & 08-80H Transfer Valves Instruction Manual 7

New Transfer Valve Model 78-80H Sectional Drawing (Standard Specification) 2017 General Electric Company. All rights reserved. Masoneilan Model 78-80H & 08-80H Transfer Valves Instruction Manual 8

New Transfer Valve Model 08-80H Sectional Drawing (Standard Specification) 2017 General Electric Company. All rights reserved. Masoneilan Model 78-80H & 08-80H Transfer Valves Instruction Manual 9

DIRECT SALES OFFICE LOCATIONS AUSTRALIA Brisbane Phone: +61-7-3001-4319 Fax: +61-7-3001-4399 Perth Phone: +61-8-6595-7018 Fax: +61-8-6595-7299 Melbourne Phone: +61-3-8807-6002 Fax: +61-3-8807-6577 BELGIUM Phone: +32-2-344-0970 Fax: +32-2-344-1123 BRAZIL Phone: +55-19-2104-6900 CHINA Phone: +86-10-5689-3600 Fax: +86-10-5689-3800 FRANCE Courbevoie Phone: +33-1-4904-9000 Fax: +33-1-4904-9010 GERMANY Ratingen Phone: +49-2102-108-0 Fax: +49-2102-108-111 INDIA Mumbai Phone: +91-22-8354790 Fax: +91-22-8354791 New Delhi Phone: +91-11-2-6164175 Fax: +91-11-5-1659635 ITALY Phone: +39-081-7892-111 Fax: +39-081-7892-208 JAPAN Tokyo Phone: +81-03-6871-9008 Fax: +81-03-6890-4620 KOREA Phone: +82-2-2274-0748 Fax: +82-2-2274-0794 MALAYSIA Phone: +60-3-2161-03228 Fax: +60-3-2163-6312 MEXICO Phone: +52-55-3640-5060 THE NETHERLANDS Phone: +31-15-3808666 Fax: +31-18-1641438 RUSSIA Veliky Novgorod Phone: +7-8162-55-7898 Fax: +7-8162-55-7921 Moscow Phone: +7 495-585-1276 Fax: +7 495-585-1279 SAUDI ARABIA Phone: +966-3-341-0278 Fax: +966-3-341-7624 SINGAPORE Phone: +65-6861-6100 Fax: +65-6861-7172 SOUTH AFRICA Phone: +27-11-452-1550 Fax: +27-11-452-6542 SOUTH & CENTRAL AMERICA AND THE CARIBBEAN Phone: +55-12-2134-1201 Fax: +55-12-2134-1238 SPAIN Phone: +34-93-652-6430 Fax: +34-93-652-6444 UNITED ARAB EMIRATES Phone: +971-4-8991-777 Fax: +971-4-8991-778 UNITED KINGDOM Bracknell Phone: +44-1344-460-500 Fax: +44-1344-460-537 Skelmersdale Phone: +44-1695-526-00 Fax: +44-1695-526-01 UNITED STATES Jacksonville, Florida Phone: +1-904-570-3409 Corpus Christi, Texas Phone: +1-361-881-8182 Fax: +1-361-881-8246 Deer Park, Texas Phone: +1-281-884-1000 Fax: +1-281-884-1010 Houston, Texas Phone: +1-281-671-1640 Fax: +1-281-671-1735 www.geoilandgas.com/valves *Denotes a registered trademark of the General Electric Company. Other company names and product names used in this document are the registered trademarks or trademarks of their respective owners. 2017 General Electric Company. All rights reserved. GEA33104 04/2017 (former Instructions JES0911EE)