Z, Y, and X PURGE INDICATORS / CONTROLLERS

Similar documents
PurgEx. Z Purge Indicator. User s Manual

PURGEX X Purge Controller E Version. User s Manual

PURGEX X Purge Controller D Version

PurgEx. X Purge Controller N Version. User s Manual

Purge Gas Inlet Kits

Models EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations

CYCLOPS. Z Purge Indicator. User s Manual

Models EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations

TRYCLOPS. X Purge Controller XP Version. User s Manual

SPECIFICATIONS ATTENTION

SITRANS P measuring instruments for pressure

4/2 way Pneumatic Solenoid Valve

780S Ultra High Purity Series

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

North American Pressure Switches

Valve Proving System VDK 200 A S06*

MEDICAL EQUIPMENT CATALOG

Valve Proving System VDK 200 A S02

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Ultra High Purity Model 780S

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

PRESSURE SWITCHES Bulletin 8757

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

Pressure Measurement Single-range transmitters for general applications

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

Model 10E Enviro-Line Environmental Pressurization System Installation & Operation Manual

Electro-Pneumatic Converter YT-940 SERIES

Inert Air (N2) Systems Manual

Autocalibration Systems For In Situ Oxygen Analyzers

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series

4 qwer 2/2 3/2 4/2. Intrinsically Safe. Air and Inert Gas Intrinsically Safe Valves Brass, or Stainless Steel Bodies 1/4" to 1" NPT SERIES.

Tightness controls TC 1 3 and TC 4

9700 Transmitter Submersible hydrostatic level transmitter

Dual Modular Safety shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634

Dual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

MTB Load Cell. Globally Approved for Accuracy and Safety. MTB Load Cell Fully Approved

Installation, Operation, & Maintenance Manual. MODEL: Watlow Controller P53 Direct, P53 Remote

Model 4000 Pressure Controller

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

Hoffman Purge/Pressurization Manual for Models PLCF1YZ PLCB1YZ

II 2G EEx ia IIC T6. Ignition protection class

G96 Series BASOTROL Dual Operator Valve

ECS Protector Nitrogen Generator PGEN-30 (PGEN-30E)

Gas Pressure Regulator HON 300

G92 Series BASOTROL Automatic Pilot Gas Valve

Pressure Measurement Single-range transmitters for general applications

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure. DMV-ZRD/612 Series DMV-ZRDLE/612 Series

Brooks TMF-Zone 1 Models 5816-Ex/5864-Ex

Infrared Linescanners

Supplementary Operator s Manual 42/24-14 EN Rev. 3

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

ATH 500 M. Pumping speed ATH 500 M. 3.1 Vacuum generation / Turbopumps / Magnetically levitated / ATH 500 M. Page 398 / Part 3.1

Pressure Switch for gas and air GGAO-A4

Pressure switch, Differential pressure switch and Thermostat RT-E

Operating Instructions

Air Operated Hydraulic Pumping Systems to 50,000 psi

Steel-Mass Model 640S

Field Certification Certificate of Compliance

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

Basic & Controlled Atmosphere Glove Boxes

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

Intrinsically safe solenoid valves on/off controls - ATEX certification

E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1.

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

Workhorse-15 Oxygen Generator

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

IPH 2 & IPX 2. Features Type 4X & Explosion-Proof Current-to-Pressure (I/P) Transmitters. Approved for Use with Natural Gas.

I/P Transducer Positioner Module

Hoffman Purge/Pressurization Manual for Models for PCFF1YZ PCFB1YZ

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

Torque Tube TB300 Digital Transmitters

Dual Modular Safety Shutoff Valves with Proof of Closure. DMV-D/622 Series DMV-DLE/622 Series

Dual Modular Safety Shutoff Valve with NEMA 4x Enclosure. DMV-D/604L Series DMV-DLE/604L Series

BUBBLER CONTROL SYSTEM

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid

SonoMeter 30 Energy Meters

Model 106 DPI "Micro-switch" Installation and Operating Instructions

VR46.5V(A)/VR86.5V(A) SERIES

CAPITAL CONTROLS SERIES NXT3000

SV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT. SV/614 Series SV-DLE/614 Series

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

Deep Submersible Level Transducer Series 300DS

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

Pressure Switch for gas and air

INSTALLATION & MAINTENANCE INSTRUCTIONS

GAS FUEL VALVE FORM AGV5 OM 8-03

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

Further technical information is available on

C-Flow Coriolis Mass Flow Meters

QBS Electronic Pressure Regulator

Autocalibration Systems for In Situ Oxygen Analyzers

Safety Shutoff Valves MVD/6 Series MVDLE/6 Series

FAS-W. Features. Applications. Automatic condensation hygrometer

PILOT OPERATED RELIEF VALVE SAFETY PRODUCTS THAT PROTECT EQUIPMENT, LIVES & THE ENVIRONMENT

Transcription:

PurgEx XXXXXX Z, Y, and X PURGE INDICATORS / CONTROLLERS PURGE / PRESSURIZATION PURGE / PRESSURIZATION XXXXX XXXXXXXXX 8626 SERIES Globally Certified Z,Y,X Purge Indicators / Controllers and Accessories Features: EXPLOSION PROTECTION INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357 by R. STAHL 1-800-782-4357 steel or anodized aluminum construction for superior corrosion resistance (NEMA 4,4X) Small Profile and light weight reduces installation footprint Global Certifications. Certified to: ATEX / IECEx / NEC / CEC in a single part number. Ideal for global companies looking to standardize on a single design Dry contact outputs for remote monitoring comes standard. EXPLOSION PROTECTION by R. Stahl 1-800-782-4357 G# G #

PURGE / PRESSURIZATION PurgEx Z, Y, and X PURGE INDICATORS / CONTROLLERS Purged and pressurized systems are an ideal method of explosion protection where components internal to the enclosure cannot be specifically rated for the area. They provide a light weight, corrosion resistant alternative to traditional explosion proof enclosure. The protection concept maintains an above atmospheric pressure within the enclosure not allowing hazardous gas and/or dust from entering and coming into contact with possible sources of ignition. The Purge Process 1) Purge Phase. In this phase, hazardous gases are removed from the enclosure by diluting the inside of the enclosure with a purge gas source. The enclosure is diluted between 4 to 5 times its cubic volume with this purge gas, eliminating ignitable amounts of hazardous materials from being present inside the enclosure. 2) Pressurized Phase. In this phase, after we have eliminated ignitable amounts of hazardous materials from being inside the enclosure. To prevent outside hazardous materials from entering into the enclosure, the enclosure is then slightly pressurized above the outside environment. Selecting Purge Indicators / Controller Here are key questions you will need to know in selecting your purge indicator / controller: 1. What protection method do you need? Z, Y, or X? Type Z This system reduces the classification within protected enclosures from Division 2 / Zone 2 to non-hazardous. Automatic power control disconnects are not required, but visual and / or audible alarms must be initiated when there is loss of pressure within enclosure. Type Y This system reduces the classification within protected enclosures from Division 1 / Zone 1 to Division 2 / Zone 2. All protected equipment inside enclosure must be rated for Division 2 / Zone 2. Automatic power control disconnects are not required, but visual and/or audible alarms must be initiated when there is loss of pressure. In addition to all requirements in Z there must be a remote monitor alarm. Type X This system reduces the classification within protected enclosures from Division 1 / Zone 1 to nonhazardous. It is required to automatically control electrical power to all protected equipment. 2. Is this a dust or gas environment? Is the hazard a Class I (Vapor, Liquid, Gas) or Class II (Dust)? G1

PurgEx Z, Y, and X PURGE INDICATORS / CONTROLLERS PURGE / PRESSURIZATION 3. How big is your enclosure? What is the cubic volume of your enclosure? Small - Up to 15 Cubic Feet Medium - Up to 75 Cubic Feet Large - Up to 200 Cubic Feet 4. Voltage? PurgEx offers the following: Z - 12 VDC, 24 VDC, 115 VAC, 230 VAC Y - 12 VDC or 24 VDC X - 115 or 230 VAC (for other voltages please consult factory) 5. Material Construction Do you require 316 (NEMA 4X) or Anodized Aluminum (NEMA 4)? 6. What type of Purge Gas Inlet Kit do you plan to use? CONTINUOUS PURGE / PURGE GAS In Continuous Purge, purge gas is continuously passed through the enclosure at a maintained pressure during and after the dilution cycle, and discharged to the outside atmosphere through an exhaust vent. This method is preferred for applications where heat builds up from the electronics within the pressurized enclosure. LEAKAGE COMPENSATIVE / PRESSURIZATION PURGE Leakage compensation allows a higher volume of purge gas during the dilution cycle, which is then reduced to only what is require to maintain the required pressure within the enclosure. This is preferred where a source of instrument grade air is limited. 7. Location of the exhaust vent. Side or Top? Traditional purge systems require an accessory exhaust vent. When one is required, is location needs to be determined (side or top mount). Please Note: If enclosure is 15 cubic feet or smaller a seperate vent is not required. G2

PURGE / PRESSURIZATION PurgEx 8626 Y/Z Purge / Pressurization Indicator CUSTOM CONFIGURATION LOGIC CLASSIFICATIONS FOR Z PurgEx NEC / CEC / UL / CSA / ANSI / ISA 12.4 & NFPA 496 Certified Class I, Division 2, Groups A,B,C,D, T6 Class II, Division 2, Groups F & G, T6 ATEX & IECEx II 3 G Ex na nl [pz] IIC T6 II 3 D Ex td A22 IP66 T79 C CLASSIFICATIONS FOR Y PurgEx NEC / CEC / UL / CSA / ANSI / ISA 12.4 & NFPA 496 Certified Class I, Division 1, Groups A,B,C,D, T4 Class II, Division 1, Groups F & G, T4 ATEX & IECEx II 2 G Ex e mb [PY] IIC T6 II 2 D Ex td A21 IP66 T79 C Start Here 7 = Dust 8 = Gas 8 626/1-D Y M 2 Dust or Gas AVAILABLE IN 316 STAINLESS STEEL OR ANODIZED ALUMINUM 626/1-D Type of Purge Size of Enclosure Voltage Y = Y Purge Z = Z Purge S = Up tp 15 Cubic Feet M = Up to 75 Cubic Feet L = Up to 200 Cubic Feet 1 = 12VDC 2 = 24VDC 3 = 115VAC* 4 = 230VAC* * Z Purge Only BRILLIANT LED INDICATOR GIVES 180 VIEWING Ambient Temperature Range: +65 C (+150 F) Max. 40 C ( 40 F) Min. Globally Certified Y/Z Purge Indicators and Accesories Features: Integral Vent standard on 15 CU FT or smaller indicators (no need to purchase or install accessory vents) Steel or Anodized Aluminum Construction for Superior Corrosion Resistance (NEMA 4, 4X) Smallest Profile and Lightest Weight on the market reduces installation footprint Global Certifications Certified to ATEX / IECEx / NEC / CEC in a single part number. Dry Contact Outputs for Remote Monitoring Come Standard. CE Marked INTERNAL VENT ELIMINATES THE NEED FOR EXTERNAL VENTS ON ENCLOSURE VOLUME UP TP 15 CUBIC FEET General Specifications: Casing Dimensions 4.5 diameter x 1.9 tall (114.3 mm diameter x 48.3 mm tall). Operating Temperature -40 F to 150 F (-40 C to 65 C) Purge Pressure Lower Limit: 0.50 inch H20 (1.25 mbar). Casing Anodized aluminum 2.48 lbs (1.13 kg), IP66, NEMA 4, (standard). 316 stainless steel, 6.80 lbs. (3.04 kg), IP66, NEMA 4X, (optional). Power Input / Consumption 0.5 Watts max. Voltage: 12 VDC model (11 VDC to 16 VDC), 47 to 63 Hz 24 VDC model (19 VDC to 28 VDC), 47 to 63 Hz 115 VAC model (85 VAC to 160 VAC), 47 to 63 Hz 230 VAC model (130 VAC to 265 VAC), 47 to 63 HZ Dry Contact Rating Contact open on alarm (standard) Contact closed on alarm (optional) 265 Volts AC / DC, 150mA max Standard Hardware All stainless steel mounting fasteners, o-ring, 1/4 (6.4 mm) diameter vent restrictor, warning label, and CD with all required documentation G3

PurgEx 8626 Technical / Dimensional Information PURGE / PRESSURIZATION CUSTOM CONFIGURATION LOGIC O S 05 T S Material Construction Alarm 05 Inlet Kit Accessory Exhaust Vent Mounting A = Aluminum S = 316 O = Contact open on alarm (standard) X = Contact closed on alarm T = Continuous Purge Inlet P = Manual Leakage Compensation Purge Inlet N = No Inlet Kit (Must be ordered seperatly. See pages G9-G14 for details on dimensions) S = Side Mounted T = Top Sided Mounted O = Specify if ordering less than 15 cu.ft indicator, or if ordering vent seperately OPTIONS & ACCESSORIES AVAILABLE CONTINUED: Protective Gas Loss Indicator Kit: An explosion-proof differential pressure switch may be installed to provide an alarm contact output signal to indicate the loss of the backup source of protective gas. Another explosion-proof differential pressure switch may be installed on the main protective gas supply to indicate that the primary protective gas pressure is adequate. Model number is PSO- PGLI-K. Differential Pressure Gauge Kit: R. STAHL also offers an all stainless steel differential pressure gauge kit, which can be mounted on the left side model number PSO-DPG-L, right side model number PSO-DPG-R, top model number PSO-DPG-T or bottom model number PSO-DPG-B of enclosure. SLOTS IN PROTECTIVE COVER TO VIEW LED FROM SIDE 2.58 (65.53) 1.88 (47.75) HOLE IN PROTECTIVE COVER TO VIEW LED FROM FRONT ENCLOSURE WALL TERMINAL BLOCKS 4.50Ø (114.30Ø) REF. 2.13 (54.10) REF. 2.83 (71.88) REF. SIDE VIEW FRONT VIEW TOP OF PurgEx AND HOLE TEMPLATE 0.28" (7.0mm) DIA. THRU TYP. 5 PLACES 72 DEGREES APART ON A 3.50" (88.9mm) DIA. B.C. INTERNAL VIEW MOUNTED ON ENCLOSURE PURGE PRESSURE REFERENCE PORT 3.00" (76.2mm) DIA. THRU POWER TERMINAL STRIP ENCLOSURE VENT PORT ALARM TERMINAL STRIP G4

PURGE / PRESSURIZATION PurgEx 8626 X Purge Controllers (XP Series) CUSTOM CONFIGURATION LOGIC CLASSIFICATIONS NEC / CEC / CSA / ANSI / ISA 12.4, & NFPA 496 Certified Class I, Division 1, Group B,C, & D, T4 Class II, Division 1, Group E,F, & G, T4 ATEX & IECEx II 2 G EX e mb ib [px] IIC T4 II 2 D EX td A21 IP66 T119 C Start Here Dust or Gas 7 = Dust 8 = Gas 8 626/1 D X M 626/1 Mounting Method D = Housing Mounted on enclosure N = Externally Mounted Housing Type of Purge X = X-Purge Size of Enclosure S = Up to 15 Cubic Feet M = Up to 75 Cubic Feet L = Up to 200 Cubic Feet Ambient Temperature Range: +65 C (+150 F) Max. 40 C ( 40 F) Min. X Purge Controllers enable the use of general purpose components to be placed inside the enclosures the X Purge will be monitoring and placed in a Division 1, and ATEX / IECEx hazardous area. This PURGEx X-Purge units come with global certifications. These units offer the lightest weight, and smallest profile controllers on the market. Because these designs mount directly on the enclosure, no additional holes, sheet metal, or plumbing is required. Globally Certified X Purge Indicators and Accesories Features: Integral Vent standard on 15 CU FT or smaller indicators (no need to purchase or install accessory vents) Steel or Anodized Aluminum Construction for Superior Corrosion Resistance (NEMA 4, 4X) Global Certifications Certified to ATEX / IECEx / NEC / CEC in a single part number. Dry Contact Outputs for Remote Monitoring Come Standard. CE Marked PurgEx X-Purge Controller (D) Integral Exhaust Vent Standard. No need to order and assemble accessory vent for enclosure with a volume up to 15 cubic feet. Available in Anodized Aluminum or 316 Steel 115 VAC up to 25 amps or 230VAC up to 12.5 Amps. Rugged, visual LED indicator for local monitoring is supplied as standard. G5

PurgEx 8626 X Purge Controllers (XP Series) PURGE / PRESSURIZATION CUSTOM CONFIGURATION LOGIC 3 A O 05 T S Voltage Material Alarm 05 Type of Compensation Exhaust Vent Mounting 3 = 115VAC 4 = 230VAC For DC voltage, consult factory A = Aluminum S = 316 O = Contact open on alarm (standard) X = Contact closed on alarm (option) T = Continuous Purge Inlet P = Manual Leakage Compensation Purge Inlet A = Automatic Leakage Compensation Purge Inlet N = No Inlet Kit (Must be ordered seperatly. See pages G9-G17 for details on dimensions) S = Side T = Top O = None (will order seperately, or 15 cubic feet or smaller) External Mounted (N) Vent Included Available in Anodized Aluminum or 316 Steel 115 VAC up to 25 amps or 230VAC up to 12.5 Amps. Rugged, visual LED indicator for local monitoring is supplied as standard. G6

PURGE / PRESSURIZATION PurgEx 8626 X Purge Controllers (XP Series) GENERAL SPECIFICATIONS Casing Dimensions 8.0 diameter x 1.9 tall (203.2 mm diameter x 48.3 mm tall), protrudes outside of purged enclosure. 6.5 diameter x 4.50 tall (65.1 mm diameter x 114.0 mm tall), protrudes inside of purged enclosure. Operating Temperature -40 F to 150 F (-40 C to 65 C) Purge Pressure Lower Limit: 0.50 inches H20 (1.25 mbar) Purge Controller will disconnect power to protected enclosure electronics. Casing Anodized aluminum 16.09 lbs (7.30 kg), NEMA 4, (IP66). 316 stainless steel, 37.98 lbs. (17.23 kg), NEMA 4X, (IP66). Power Control Capability 115 VAC up to 25 Amps RMS continuous over specified voltage ranges. 230 VAC up to 12.5 Amps RMScontinous over specified voltage ranges. Power Input / Consumption 0.5 Watts max. Voltage: 115 VAC model (85 VAC to 160 VAC), 47 to 63 Hz 230 VAC model (130 VAC to 265 VAC), 47 to 63 HZ Dry Contact Outputs & Rating 1. Enclosure purge pressure is below 0.50 inches H20 (1.25 mbar). 2. Enclosure exhaust flow has stopped. 3. Purge Controller is in maintenance mode. Contacts open on alarm (standard). Contacts closed on alarm (optional). All rated to 265 Volts AC/DC, 150mA max. Standard Hardware All stainless steel mounting hardware, o-ring, 1/4 (6.4 mm) diameter exhaust vent restrictor, CD with all required documentation. Hazardous Area Approvals ATEX and IECEx II 2 G EX e mb ib [px] IIC T4 for gas hazardous areas II 2 D EX td A21 IP66 T119 C for dust hazardous areas ANSI / ISA 12.4, CEC, NEC, and NFPA 496 Class I, Division 1, Group B,C, & D, T4 for gas hazardous areas Class II, Division 1, Group E,F, & G, T4 for dust hazardous areas Certified to an Ambient Temperature Range of -40 F (-40 C) <Tamb< + 150 F (+65 C) CE Marked G7

PurgEx 8626 X Purge Controllers (XP Series) PURGE / PRESSURIZATION DIMENSIONAL INFORMATION 8.00" DIA. (203.2mm DIA.) 2.50" (63.5mm) OUTSIDE ENCLOSURE SEALING SURFACE SIDE VIEW OF UNIT 6.40" DIA. (162.6mm DIA.) FRONT VIEW OF UNIT 1.82" (46.2mm) 4.50" INSIDE ENCLOSURE (114.3mm) INSIDE ENCLOSURE LOCAL LED STATUS INDICATOR 0.25" (6.4mm) OUTER DIA. TUBE COMPRESSION FITTING UP TO 6 PLACES TYP. X - PURGE CONTROLLER 10.42" (264.7mm) 10.30" (261.6mm) 8.34" (211.8mm) 9 G8

PURGE / PRESSURIZATION PurgEx 8626 Sheet Steel X Purge Controllers CUSTOM CONFIGURATION LOGIC CLASSIFICATIONS ATEX & IECEx II 2 G EX e mb ib [px] IIC T4 II 2 D EX td A21 IP66 T119 C Ambient Temperature Range: +65 C (+150 F) Max. 40 C ( 40 F) Min. Start Here Dust or Gas 7 = Dust 8 = Gas 8 626/1 E X M 626/1 Protection Method E = Housing Mounted on enclosure M = Externally Mounted Housing Type of Purge X = X-Purge Size of Enclosure S = Up to 15 Cubic Feet M = Up to 75 Cubic Feet L = Up to 200 Cubic Feet X Purge Controllers enable the use of general purpose components to be placed inside the enclosures the X Purge will be monitoring and placed in and ATEX or ECEx hazardous area. These units offer the lightest weight, and smallest profile controllers on the market. Because these designs mount directly on the enclosure, no additional holes, sheet metal, or plumbing is required. Globally Certified X Purge Indicators and Accesories Features: Integral Vent standard on 15 CU FT or smaller indicators (no need to purchase or install accessory vents) Steel Superior Corrosion Resistance (NEMA 4X) Global Certifications Certified to ATEX / IECEx in a single part number. Dry Contact Outputs for Remote Monitoring Come Standard. CE Marked PurgEx X-Purge Controller (E) Integral Exhaust Vent Standard. No need to order and assemble accessory vent enclosure with a volume up to 15 cubic feet. 316 Steel 115 VAC up to 25 amps or 230VAC up to 12.5 Amps. Rugged, visual LED indicator for local monitoring is supplied as standard. G9

PurgEx 8626 Sheet Steel X Purge Controllers PURGE / PRESSURIZATION CUSTOM CONFIGURATION LOGIC 3 S O 05 T S Voltage Material Alarm 05 Type of Compensation Exhaust Vent Mounting 3 = 115VAC 4 = 230VAC For DC voltage, consult factory S = 316 O = Contact open on alarm (standard) X = Contact closed on alarm (option) T = Continuous Purge Inlet P = Manual Leakage Compensation Purge Inlet A = Automanic Leakage Compensation N = No Inlet Kit (Must be ordered seperatly. See pages G9-G13 for details on dimensions) S = Side T = Top O = None (will order seperately, or 15 cubic feet or smaller) PurgEx External Mount (M) Vent Included G10

PURGE / PRESSURIZATION PurgEx 8626 X Purge Controllers GENERAL SPECIFICATIONS Operating Temperature -40 F to 150 F (-40 C to 65 C) Purge Pressure Lower Limit: 0.50 inches H20 (1.25 mbar) Purge Controller will disconnect power to protected enclosure electronics. Enclosure 14 gage 316 stainless steel, 11.00 lbs. (5.00 kg), NEMA 4X, (IP66). Power Control Capability 115 VAC up to 25 Amps RMS continuous over specified voltage ranges. 230 VAC up to 12.5 Amps RMScontinous over specified voltage ranges. Power Input / Consumption 0.5 Watts max. Voltage: 115 VAC model (85 VAC to 160 VAC), 47 to 63 Hz 230 VAC model (130 VAC to 265 VAC), 47 to 63 HZ Dry Contact Outputs & Rating 1. Enclosure purge pressure is below 0.50 inches H20 (1.25 mbar). 2. Enclosure exhaust flow has stopped. 3. Purge Controller is in maintenance mode. Contacts open on alarm (standard). Contacts closed on alarm (optional). All rated to 265 Volts AC/DC, 150mA max. Standard Hardware All stainless steel mounting hardware, gasket, and CD with all required documentation Hazardous Area Approvals ATEX and IECEx II 2 G EX e mb ib [px] IIC T4 for gas hazardous areas II 2 D EX td A21 IP66 T119 C for dust hazardous areas Certified to an Ambient Temperature Range of -40 F (-40 C) <Tamb< + 150 F (+65 C) CE Marked G11

PurgEx 8626 X Purge Controllers PURGE / PRESSURIZATION DIMENSIONAL INFORMATION 7.25 (184.2) 3.38 (85.9) X - PURGEx CONTROLLER 0575 II 2 G Ex e mb [px] IIC T4 Gb II 2 D Ex td [px] A21 T119 C IP66 Db DNV-2008-OSL-ATEX-10575 IECEx DNV 08.0323 WARNING ENCLOSURE SHALL NOT BE OPENED UNLESS POWER IS REMOVED OR AREA HAS BEEN PROPERLY TESTED AND IS KNOWN TO BE NON-HAZARDOUS. 6.25 (158.8) 8.23 (209.0) Serial No. 115 VAC, 50/60 Hz, 25 Amps 230 VAC, 50/60 Hz, 12.5 Amps DRY CONTACT RATING = 265 AC/DC, 150 ma 8.23 (209.0) FRONT VIEW 3.92 (99.6) RIGHT SIDE VIEW 10.38 (263.7) 0.28 (7.1) TYP. 4 PLACES 0.25 (6.4)Ø O.D. TUBE COMPRESSION FITTING TYP. 6 PLACES ENCLOSURE 3 PRESSURE 10.70 (271.8) 9.00 (228.6) ENCLOSURE 3 EXHAUST ENCLOSURE 2 PRESSURE ENCLOSURE 2 EXHAUST ENCLOSURE 1 PRESSURE 2.50 (63.5) 1.50 (38.1) 0.50 (12.7) C 0.50 (12.7) L 1.50 (38.1) 2.50 (63.5) ENCLOSURE 1 EXHAUST 1.17 (29.7) TYP. 3 PLACES 6.50 (165.1) 1.92 (48.8) TYP. 3 PLACES 7.00 (177.8) HUB PANEL OPENING 0.50 (5.1) TO EDGE OF HUB PANEL OPENING 1.53 (38.9) HUB PANEL OPENING REMOVABLE HUB PANEL OPENING 7.00 (177.8) 3.87 (98.3) TO EDGE OF HUB PANEL OPENING ATMOSPHERIC VENT SPARK ARRESTOR INSTALLED 1.17 (29.7) 2.00 (50.8) 13 G12

PURGE / PRESSURIZATION Continuous Dilution Purge Gas Inlet Kits PRESSURE REGULATOR ADJ. KNOB ENCLOSURE WALL OUTSIDE ENCLOSURE WALL INSIDE C 4.00 (101.6) PRESSURE GAUGE 0.22Ø (5.6Ø) THRU ENCLOSURE WALL FOR MOUNTING A 5.15 (130.8) ON 1.81 (46.0) ON SHUT-OFF VALVE SHOWN IN ON POSITION 0.77Ø (19.6Ø) THRU ENCLOSURE WALL FOR MOUNTING 0.92 (23.4) B 4.44 (112.8) FRONT VIEW NOTE: PURGE GAS INLET = 1/4-18 FNPT SIDE VIEW MOUNTING HOLE PATTERN Size Information Size A (mm) B (mm) C (mm) Purge Gas Inlet Size Enclosure Volume Small 5.15 (130.8) 4.44 (112.8) 4.00 (101.6) 1/4-18 FNPT Up to 15 Cubic Feet Medium 6.19 (157.2) 4.68 (118.9) 4.23 (107.4) 3/8-18 FNPT Up to 75 Cubic Feet Large 6.19 (157.2) 4.68 (118.9) 4.23 (107.4) 1/2-14 FNPT Up to 200 Cubic Feet Ordering Information Size Enclosure Type Catalog Number Small Medium Large Aluminum Aluminum Aluminum PSO-SCD-A PSO-SCD-S PSO-MCD-A PSO-MCD-S PSO-LCD-A PSO-LCD-S G13

Manual Leakage Compensation Purge Gas Inlet Kits PURGE / PRESSURIZATION PRESSURE REGULATOR ADJ. KNOB ENCLOSURE WALL OUTSIDE LEAKAGE COMPENSATION SET SCREW JAM NUT ENCLOSURE WALL INSIDE 0.45Ø (11.4Ø) THRU ENCLOSURE WALL FOR MOUNTING C 4.00 (101.6) PRESSURE GAUGE A 5.15 (130.8) ON 2.49 (63.3) ON DILUTION VALVE SHOWN IN ON POSITION 0.77Ø (19.6Ø) THRU ENCLOSURE WALL FOR MOUNTING 0.92 (23.4) B 4.44 (112.8) FRONT VIEW SHOWN IN FAST DILUTION ON POSITION NOTE: PURGE GAS INLET = 1/4-18 FNPT SIDE VIEW MOUNTING HOLE PATTERN Size Information Size A (mm) B (mm) C (mm) Purge Gas Inlet Size Enclosure Volume Small 5.15 (130.8) 4.44 (112.8) 4.00 (101.6) 1/4-18 FNPT Up to 15 Cubic Feet Medium 6.19 (157.2) 4.68 (118.9) 4.23 (107.4) 3/8-18 FNPT Up to 75 Cubic Feet Large 6.19 (157.2) 4.68 (118.9) 4.23 (107.4) 1/2-14 FNPT Up to 200 Cubic Feet Ordering Information Size Enclosure Type Catalog Number Small Medium Large Aluminum Aluminum Aluminum PSO-SMLC-A PSO-SMLC-S PSO-MMLC-A PSO-MMLC-S PSO-LMLC-A PSO-LMLC-S G14

PURGE / PRESSURIZATION Automatic Leakage Compensation Purge Gas Inlet Kits Size Information Size A (mm) B (mm) C (mm) D (mm) E (mm) F (mm) *X Purge Controllers Only Purge Gas Inlet Size Enclosure Volume Small 3.57 (90.7) 4.44 (112.8) 3.28 (83.3) 4.95 (125.7) 2.53 (64.3) 3.31 (84.1) 1/4-18 FNPT Up to 15 Cubic Feet* Medium 4.89 (124.2) 4.68 (118.9) 3.84 (97.5) 4.31 (109.5) 2.75 (69.8) 3.93 (99.8) 3/8-18 FNPT Up to 75 Cubic Feet* Large 4.89 (124.2) 4.68 (118.9) 3.84 (97.5 4.31 (109.5) 2.75 (69.8) 3.93 (99.8) 1/2-14 FNPT Up to 200 Cubic Feet* Ordering Information Size Enclosure Type Voltage Enclosure Type Catalog Number Small Aluminum 115VAC 230VAC 115VAC 230VAC Zone1 Div1 PSO-SALC-D1A PSO-SALC-Z1A PSO-SALC-D2A PSO-SALC-Z2A PSO-SALC-D1S PSO-SALC-Z1S PSO-SALC-D2S PSO-SALC-Z2S Medium Aluminum 115VAC 230VAC 115VAC 230VAC PSO-MALC-D1A PSO-MALC-Z1A PSO-MALC-D2A PSO-MALC-Z2A PSO-MALC-D1S PSO-MALC-Z1S PSO-MALC-D2S PSO-MALC-Z2S Large Aluminum 115VAC 230VAC 115VAC 230VAC PSO-LALC-D1A PSO-LALC-Z1A PSO-LALC-D2A PSO-LALC-Z2A PSO-LALC-D1S PSO-LALC-Z1S PSO-LALC-D2S PSO-LALC-Z2S G15

Automatic Leakage Compensation Purge Gas Inlet Kits PURGE / PRESSURIZATION ENCLOSURE WALL OUTSIDE PRESSURE REGULATOR ADJ. KNOB LEAKAGE COMPENSATION SET SCREW JAM NUT PRESSURE GAUGE A 3.57 (90.7) B 4.44 (112.8) FRONT VIEW NOTE: PURGE GAS INLET = 1/4-18 FNPT ENCLOSURE WALL INSIDE C 3.28 (83.3) D 4.95 (125.7) 0.45Ø (11.4Ø) THRU ENCLOSURE WALL FOR MOUNTING 0.77Ø (19.6Ø) THRU ENCLOSURE WALL FOR MOUNTING E 2.53 (64.3) F 3.31 (84.1) SIDE VIEW MOUNTING HOLE PATTERN 1.06 (26.9) 0.55 (14.0) G16

PURGE / PRESSURIZATION Back-Up Vents, Top Mount A B Size Small Medium Large Box Hole Size Required 0.57Ø (14.5Ø) 1.31Ø (33.3Ø) 2.38Ø (60.5Ø) Size Small Medium Large Catalog Number PSO-SBUV-T PSO-MBUV-T PSO-LBUV-T Size Side Dimensions A 2.14Ø (54.4Ø) Small B 4.00 (101.6) A 3.50Ø (88.9Ø) Medium B 5.75 (146.1) A 5.12Ø (130.1Ø) Large B 7.62 (193.6) G17

Back-Up Vents, Side Mount PURGE / PRESSURIZATION A B C Size Box Hole Size Required Small 0.57Ø (14.5Ø) Medium 1.31Ø (33.3Ø) Large 2.38Ø (60.5Ø) Size Side Dimensions A 2.50 (63.5) Small B 5.00 (127.0) C - A 4.28 (108.7) Medium B 7.36 (186.9) C 6.47 (163.3) A 6.03 (153.2) Large B 10.42 (264.7) C 9.11 (231.4) Size Small Medium Large Catalog Number PSO-SBUV-S PSO-MBUV-S PSO-LBUV-S G18

PURGE / PRESSURIZATION Top & Side Vent Mount Configurations FOR EXTERNAL MOUNTED (N) AND (M) MODELS ONLY NOTES: 1. REQUIRED HOLE THRU ENCLOSURE WALL FOR VENT IS 0.57Ø (14.48Ø) VENT CAP ASSY. 1/4 INCH TUBE x PIPE NIPPLE FITTING PIPE NIPPLE x STRAIGHT THREAD FITTING HEX NUT PIPE NIPPLE PIPE TEE TOP OUTSIDE WALL OF ENCLOSURE TOP INSIDE WALL OF ENCLOSURE Size Top / Side Catalog Number Top DO-11068-B Small DO-11069-B Side DO-11070-B Top DO-11113-B Medium DO-11114-B Side DO-11115-B Top DO-11128-A Large DO-11129-A Side DO-11130-A Top Vent Mount Option SIDE OUTSIDE WALL OF ENCLOSURE SIDE OUTSIDE WALL OF ENCLOSURE VENT CAP ASSY. SIDE INSIDE WALL OF ENCLOSURE VENT CAP ASSY. SIDE INSIDE WALL OF ENCLOSURE PIPE NIPPLE PIPE NIPPLE 1/4 INCH TUBE x PIPE NIPPLE FITTING PIPE TEE HEX NUT PIPE TEE PIPE THREAD x STRAIGHT THREAD FITTING HEX NUT 1/4 INCH TUBE x PIPE NIPPLE FITTING PIPE NIPPLE x STRAIGHT THREAD FITTING NOTES: NOTES REQUIRED HOLE THRU ENCLOSURE WALL FOR VENT IS 0.57Ø (14.48Ø) 1. REQUIRED HOLE THRU ENCLOSURE WALL FOR VENT IS 0.57 (14.48Ø) R. STAHL, Inc. 13259 N. Promenade Blvd Stafford, TX 77477 Phone: 1-800-782-4357 www.rstahl.com Literature Order: CY 042814 Side Vent Mount Option Vent Mount Size Size Box Hole Size Required Small 0.57Ø (14.48Ø) Medium 1.31Ø (33.3Ø) Large 2.38Ø (60.5Ø) G19