Ophthalmology Clinical Pearls A Quick Guide To Crystalens

Similar documents
Getting Started GUIDE LEAVE A LEGACY OF EXCELLENT OUTCOMES FOR PATIENTS WITH ASTIGMATISM. TECNIS TORIC 1-PIECE IOL pg 1

Biometry tips. Marilyn Watkins-Ramdin, COMT ROUB

Learn Connect Succeed. JCAHPO Regional Meetings 2017

Fitting Guide. Minutes-to-Fit 2.0. by SynergEyes Moving Vision Forward

LENS EXCHANGE WITH IMPLANTATION OF A BITORIC INTRAOCULAR LENS IN EYES WITH SIGNIFICANT ASTIGMATISM AFTER PREVIOUS CORNEAL SURGERIES

Appendix C: Skill Stations Examination - Marking Rubric

Acknowledgments. Paragon Vision Sciences Adoption of CRT certification slide for this generic talk. Material Considerations

Sofmed breathables XW (comfilcon A) Sofmed breathables XW premium (comfilcon A) Sofmed breathables XW toric (comfilcon A)

In November 1998, the Staar AA4203 toric intraocular. Early rotational stability of the longer Staar toric intraocular lens. Fifty consecutive cases

Scleral Fitting Guide

Appendix C: Skill Stations Examination - Marking Rubric

POLYMACON HYDROPHILIC CONTACT LENSES PRACTITIONER FITTING GUIDE

LENSTAR LS 900 Setting the standard in optical biometry

An introduction to modern scleral lenses

THE TOP 100 KEYWORDS FOR AN

INTRASTROMAL CORRECTION OF PRESBYOPIA AND CLINICAL APPLICATION WITH TECHNOLAS FEMTOSECOND LASER

Refraction Certificate Examination. Instructions to Candidates

Dr. Thomas R. Reim President, DreimLens, Inc.

International Council of Ophthalmology s Ophthalmology Surgical Competency Assessment Rubric (ICO-OSCAR) ICO-OSCAR Instructor Directions

Procedures for ETDRS 4M Refraction and Vision Testing. Katherine M. Burke, BS, CO, COMT CertifEYED Associates, LLC New York, New York

Injector system for implantation of 1stQ foldable intraocular lenses

PACKAGE INSERT RIGID GAS PERMEABLE CONTACT LENSES FOR ORTHOKERATOLOGY. (hexafocon B)

EVERY TREATMENT IS A TRUE ORIGINAL

Financial Disclosures Toric IOL Selec-on and Posi-oning

Pre- and postoperative refraction after cataract extraction with implantation of standard power IOL

Alberta Police Recruit Selection Standards

How images are formed in the eye

Orthokeratology. What is Orthokeratology? How does it work?

NormalEyes Guidelines For Successful Fitting RIGID GAS PERMEABLE SCLERAL CONTACT LENSES. Manufactured in Paragon HDS 1OO (paflufocon D)

Spherical Soft Contact Lens Fitting. J. Perrigin OPTO 6374 Spring 2017

The BE Retainer System Certification Course. Supplement

CLINICAL SCIENCES. Michael Goggin, FRCSI(Ophth), MS; Sacha Moore, FRCOphth; Adrian Esterman, AStat, PhD

LASIK Wavefront Guided idesign LASIK with IntraLase

CATALOG CATALOG. Pioneer in Ophthalmic Products. BACK FLUSH INSTRUMENTS VITREORETINAL INSTRUMENTS

TONOMETRY AND PACHYMETRY

DISCLOSURES FITTING AND TROUBLESHOOTING SCLERAL LENSES WHO S A GOOD CANDIDATE SCLERAL LENS ADVANTAGES ANDREW J. BIONDO, OD, FSLS.

Phacoemulsification and foldable posterior chamber intraocular lenses in aircrew: Clinical behaviour and aeromedical implications

25+ instruments answer the most common barrier to 25G instrument flexibility.

FITTING AND TROUBLESHOOTING SCLERAL LENSES

12.15 CORNEAL REFRACTIVE SURGERY (PRK/LASEK/LASIK/SMILE)

Andre Litwin BM FRCOphth Consultant Ophthalmologist and Oculoplastic Surgeon

senofilcon A Soft (hydrophilic) Contact Lenses Visibility Tinted with UV Blocker for Daily Disposable Wear

PACKAGE INSERT RIGID GAS PERMEABLE CONTACT LENSES FOR CONTACT LENS CORNEAL REFRACTIVE THERAPY

Pardon the Objection (PTO) Contact Lens Clinical Case Debate (2 hours)

V E J A R A N O P R O T O C O L FOR T H E M A N A G M E N T O F Q U E R A T O C O N O SURGICAL T I PS

PROFESSIONAL FITTING AND INFORMATION GUIDE. Paragon CRT Manufactured in Paragon HDS (paflufocon B)

ASICO Innovative I/A Tip System (Patented) Maximize your I/A efficiency for Today s MICS and FLACS procedure

REFRACTIVE ERRORS in. CORRECTION of OPTICAL DIVERS USING OPTICAL MASKS

PROFESSIONAL FITTING GUIDE. for the. HUBBLE Daily. Table of Contents

Ophthalmic Surgical Instruments

Management of corneal wounds: some practical tips. Lee SH, MD, FRCS (C ), FAAO

Triple EK/CE/IOL has a cataract needs both DMEK and CEIOL

International Council of Ophthalmology s Ophthalmology Surgical Competency Assessment Rubric (ICO-OSCAR)

Ophthalmic Surgical Instruments

OPESAVER Super Irrigation System

Accommodation responses and refractive error

Manual Small Incision Cataract Surgery

A life without glasses or contact lenses

Basic Concept & Techniques of Phaco Prechop

Reusable Ophthalmic Instruments

Keeler Digital Applanation Tonometer (D-KAT)

PENTICTON FIRE DEPARTMENT AUXILIARY FIRE FIGHTER INFORMATION PACKAGE

RECOMMENDER REQUIRED PRE-AUTH GROUP A PRE-AUTH GROUP B

Research Article Incidence and Outcomes of Anterior Chamber Gas Bubble during Femtosecond Flap Creation for Laser-Assisted In Situ Keratomileusis

Four common PRESSURE CALIBRATION PAIN POINTS

FRA Spacer Instruments. For anterior lumbar interbody fusion (ALIF) using straight anterior or anterolateral approach.

NAVAL SUBMARINE MEDICAL RESEARCH LABORATORY

Sterile, Single-use, Instruments

SPORTS VISION MORE THAN JUST 20/20 AND CONTACT LENSES NZAO CONFERENCE 2017

Single-use Ophthalmic Instruments

Training Guide STAR S4 IR Excimer Laser

Ocular hazards of playing squash

Relative Humidity Calibration Kit

COMPARISON OF DIFFERENTIAL PRESSURE SENSING TECHNOLOGIES IN HOSPITAL ISOLATION ROOMS AND OTHER CRITICAL ENVIRONMENT APPLICATIONS

CT210 Contact Applanation Tonometer

Single-use Ophthalmic Instruments

AIR OPTIX BRAND CONTACT LENSES LENS PARAMETER GUIDE November 2016

Coast Guard AERO Technical Bulletins

Lynne Sandmeyer DVM, DVSc, DACVO Associate Professor Ophthalmology University of Saskatchewan

Indications for Use: Caution: Note:

James T. Schwiegerling CURRICULUM VITAE

Using Race Times Results

BIORAPTOR Knotless Suture Anchor Arthroscopic Shoulder Instability Repair. Shoulder Series Technique Guide by: Thomas Youm, MD

CHAPTER 7 : SMOKE METERS AND THEIR INSTALLATIONS

Strata Valve ADJUSTMENT REFERENCE GUIDE

Chapter 53: Clinical Center Single-Breath Carbon Monoxide Diffusing Capacity (DLCO) MOP 53.1 Introduction

Insert to. Sponsored by Alcon Laboratories, Inc. February 2014 EXPLORING THE CATARACT REFRACTIVE SUITE FEATURING. The CENTURION Vision System

OPTIMA HEALTH MEDICAL FITNESS ASSESSMENT FOR TRAIN DRIVERS / TRAIN DRIVER MANAGERS PROCEDURE

R I T. Title: Amray 1830 SEM Semiconductor & Microsystems Fabrication Laboratory Revision: A Rev Date: 09/29/03 1 SCOPE 2 REFERENCE DOCUMENTS

Satisfaction. For you and your patients.

Stephen Lash Post operative instructions- Combined Surgery (Cataract and vitrectomy)

Instruction Sheet. Important Note: Information that requires special emphasis. Note: Information that supplements points in the main text.

CARDIOVIT AT-104 ergospirometry

Your new Keystone Telebinocular

STANDARD OPERATING PROCEDURE FORCE DIAL FDN 100

MyoSure Tissue Removal System. For you and your patients.

Jackson Safety * Nemesis * Eyewear. Stylish Comfort. Lasting Protection.

STANDARD OPERATING PROCEDURE FORCE DIAL FDN 100

Corrective Lens Use and Refractive Error Among United States Air Force Aircrew

Force & Motion. Objective 6.P.1. 6.P.1 Understand the properties of waves and the wavelike property of energy in earthquakes, light and sound.

Transcription:

Ophthalmology Clinical Pearls A Quick Guide To Crystalens Crystalens Accommodating Posterior Chamber Intraocular Lens BRIEF STATEMENT Rx only. Indications for Use: The Crystalens is intended for primary implantation in the capsular bag of the eye for the visual correction of aphakia secondary to the removal of a cataractous lens in adult patients with and without presbyopia. The Crystalens provides approximately one diopter of monocular accommodation which allows for near, intermediate, and distance vision without spectacles. Warnings: Careful preoperative evaluation and sound clinical judgment should be used by the surgeon to decide the risk/ benefit ratio before implanting a lens in a patient. Some adverse events which have been associated with the implantation of intraocular lenses are: hypopyon, intraocular infection, acute corneal decompensation, and secondary surgical intervention. Precautions: Do not resterilize; do not store over 45 C. ATTENTION: Refer to the Physician Labeling for complete prescribing information. This resource is intended for use by physicians and other healthcare professionals involved in patient care. It is not intended and should not be construed as medical advice, nor is it intended to replace sound clinical judgment in the delivery of healthcare services. All medical and clinical data contained or made available in this resource is intended to supplement the knowledge of physicians and other healthcare professionals involved in patient care. The absence of a warning for a given procedure, technique or suggestion contained in this resource should not be construed to indicate that such procedure, technique or suggestion is safe, appropriate or effective in any given patient. 2010 Bausch + Lomb Incorporated. / denote trademarks of Bausch + Lomb Incorporated. Other brands/products are trademarks of their respective owners. SU5333-3 05/10

Patient Selection And Consideration Indications Crystalens is intended for primary implantation in the capsular bag of the eye for the visual correction of aphakia secondary to the removal of a cataractous lens in adult patients with and without presbyopia Crystalens provides approximately one diopter of monocular accommodation, which can offer near, intermediate, and distance vision without spectacles 2 3 The Ideal Patient Physical Attributes Good ocular health Potential for good visual acuity (VA) in each eye Does the patient have corneal astigmatism? - Plan for treatment if over 0.75 D - Limbal relaxing incisions can be done during IOL implantation - Refractive enhancements can be done three months post-op (any necessary YAG capsulotomy should be done prior to any refractive surgery) - VA outcomes will be enhanced by bilateral implantation If you are just starting with Crystalens, please see additional patient selection criteria for initial surgeries Psychological Attributes Nondemanding Realistic expectations

Pre-Op Suggestions Pre-Op Measurements Use the IOL Master and/or manual keratometry to obtain keratometric readings before any eye drops, applanation, or corneal manipulation For contact lens wearers, ensure that contact lens use has been discontinued long enough to provide corneal stability Use the IOL Master and/or immersion ultrasonography to measure axial length Make sure As and Ks correlate with oldest known refraction Pearls For Accurate Biometry Things to consider before you start: Measure K readings on an untouched clear cornea (no drops, applanations, etc.) Take note of any dry eye or other ocular pathology that may affect the corneal surface and fixation For contact lens wearers, ensure that contact lens use has been discontinued long enough to provide corneal stability - Take two readings one week apart showing stable measurements before accepting the measurement for IOL calculations If the patient is pseudophakic and axial length is being verified post-operatively, ensure that the velocity is set for the IOL material Keratometry Manual Make sure the keratometer is calibrated on a regular basis Focus the ocular lens before taking any measurements Take at least three readings per eye to ensure accuracy and consistency of measurements Have the patient blink frequently between measurements to avoid drying the cornea If the patient has dry eye, artificial tears may help obtain more reliable measurements IOL Master Run instrument calibration every day Alignment is important; make sure all six measuring points are visible and between the two auxiliary circles The six measuring points must be in focus Have the patient blink a few times and open wide before pressing the button If the patient has dry eye, artificial tears may help obtain more reliable measurements Axial Length Measurement Immersion Calibrate instrument each day that the instrument is in use Make sure your machine is set properly - Phakic, pseudophakic, etc. - Gates and gain Patient fixation and probe alignment are important. When all five spikes (cornea, anterior lens surface, posterior lens surface, retina, and sclera) are high and steeply rising, you are most likely on the visual axis. Posterior to the scleral spike, you should see multiple spikes that drop off in height (orbital fat). If the scleral spike is missing and very few small spikes are observed posterior to the retinal spike, you are most likely measuring into the optic nerve 4 5 IOL Master Make sure your machine is set properly - Phakic, pseudophakic, etc. The patient should fixate on the red fixation light You can maneuver the central focusing spot within the measurement reticule to obtain the best signal curve display You can defocus (in or out) if needed to improve the display Signal-to-noise ratio (SNR) should be above 2.0

For All Measurements Reproducibility and accuracy are absolute requirements - Keratometry: repeated measurements should be within 0.12 D in each meridian - Immersion: SD should be within 0.09 mm - IOL Master: at least 4/20 measurements must be within 0.02 mm, with good signal curve display and SNR >2.0 Do not hesitate to have a second examiner confirm your measurements Putting It All Together Keratometry The amount of astigmatism must correlate with the oldest known refraction If there is a difference of >0.50 D between OD/OS, does it correlate with the oldest known refraction? Targeting For the Crystalens AO and Crystalens Five-O: Distance eye: select the lens that predicts between plano and -0.25 Near eye: select the lens that targets between -0.25 and -0.50 For the Crystalens HD, the optimal refractive target for each eye is plano. In those cases where the lens calculation does not result in a lens that targets plano, the following is suggested: Distance eye: select the lens that predicts the first plus outcome above plano Near eye: select the lens that predicts the first minus below plano Note: the lens power selection may have to be adjusted based on the refractive outcome of the first eye. Accurate manifest refraction is critical take time to refine. In choosing which eye to operate on first, select the eye with the worse cataract. If cataracts are equal, select the eye most likely to impress the patient. Crystalens Nomogram For Short Eyes Axial Length The axial length must correlate with the oldest known refraction If there is a difference of >0.3 mm between OD/OS, does it correlate with the oldest known refraction? 6 7 Surgical And Post-Op Pearls Surgery Recommendations Lens Power Calculations The SRK-T formula will be used for eyes with axial lengths measuring 22.01 mm or longer - Recommended starting A constant for the Crystalens AO is 119.1, Crystalens HD is 118.8, and Crystalens Five-O is 119.0 The Holladay II formula will be used for eyes with axial lengths measuring 22.0 mm or shorter The Holladay II is suggested for eyes with Ks flatter than 42.00 D or steeper than 47.00 D, independent of axial length - Manufacturer s recommended starting ACD for Crystalens AO is 5.61, Crystalens HD is 5.43, and Crystalens Five-O is 5.55 Surgical And Post-Op Create a symmetrical capsulorhexis measuring 5.5 mm to 6.0 mm Ensure that both plates and all four haptics are secure in the capsule; the optic should be well centered and in a posterior position Use one drop of atropine at the close of the case Post-op Day 1 uncorrected distance visual acuity (UCDVA) critical, uncorrected intermediate visual acuity (UCIVA), and uncorrected near visual acuity (UCNVA) optional. Post-op Days 7 to 14 check UCDVA, UCIVA, UCNVA, and perform testing listed on the DataLink form and submit or enter findings. - Measure distance corrected near VA - Measure binocular acuities at all ranges after the second eye has been implanted to assess visual function - Verify refractive findings with a cycloplegic refraction when VAs and refraction do not correlate or if near VA is not J3 or better - Confirm on slit examination the vault (posterior, neutral, or anterior) and centration of the Crystalens - It is recommended to keep patients on NSAIDs until the medication is gone and Lotemax medication for 8 to 10 weeks

Post-Op Evaluations Things To Consider In the initial post-op period, the accommodative change between distance and near may be slow Because Crystalens patients can accommodate, you should refract them as you would a young myope which is very different from your normal post-op routine Before the examination, most patients are sitting in the waiting room reading which means they are probably accommodating Evaluate all distance measurements before doing intermediate and near measurements Suggested Techniques For Post-Op Evaluations Have the patient read the smallest line possible At this point, the patient has to earn any more minus. If they can read more letters, or if it is definitely clearer, they get it. If they cannot see more letters, or if it is darker and smaller, they DO NOT get additional minus. Generally, you have reached your endpoint if adding a little plus makes the image blurred, and if you add minus, it stays the same or darker. No matter how much they might like more minus, you have to stop unless it truly helps them see better. Do not hesitate to repeat fogging if you think it is necessary. It is faster and easier to do it now, rather than coming back after the next set of steps. (You can add +1.00 D sphere, change the smallest line, and slowly reduce power by 0.25 D steps to see if you have the same endpoint.) Measure UCIVA at 28" to 32" and then UCNVA at 16", again giving the patient time to blink and focus Remember to measure intermediate VA Measure the UCDVA, giving the patient time to blink and focus Determine the starting point for your maximum plus refraction - Ensure that the UCDVA and the target outcome correlate (refer to chart on page 10) - Auto-refractors tend to over-minus DO NOT use this sphere as your starting point - K readings will indicate the approximate amount of cylinder and the axis - If performing retinoscopy, ensure that the patient is fixating on a letter on the chart and not on the retinoscope - Use this information to determine your starting point in the phoropter Tell the patient it might appear blurred and see how far down the chart they can read Isolate the line that is two lines above the lowest line that the patient can read. Slowly add plus sphere power until the line is fully blurred. It may take 1.50 D to 2.00 D of additional plus sphere to accomplish this. Isolate the 20/25 line. Tell the patient it will be blurred. Slowly add minus until the patient can read it. Next, isolate the 20/20 line and add minus sphere in small steps. Only give minus if the patient can read more letters. Do not use the which is better? technique. By relying on letters read, you are making this a more objective test. Refine the cylinder axis and power with the Jackson Cross Cylinder - Maintain spherical equivalent by adjusting 0.25 D of sphere for every 0.50 D of cylinder change Corrected VA Assessments And Add Power Measure all ranges of vision (distance, intermediate, and near) as above, but through the distance correction With the near card at 16", slowly add plus over the distance correction in 0.25 D steps until the patient can read J1. If the add is more than +1.50 D, you may have overminused the sphere. 8 9 Things To Reconsider Do the uncorrected visions (all ranges) correlate with the refraction? If you think the patient may be over-minused and you cannot undo it, recheck the UCDVA. If the vision has decreased since the start of the examination, ask the patient to relax and refocus at a distance target. Cycloplegic Refraction If your patient is not reading J3 or better through the distance correction, you must do a cycloplegic refraction to rule out subtle hyperopia/over-minus/accommodative spasm This is a very important step in assessing the true maximum plus refraction in an accommodating Crystalens patient After following the steps above, give the patient Cyclopentolate 1%, 1 drop q5min x2. Wait at least 30 minutes (the patient may dilate before they are actually cyclopleged). Refine the refraction. Measure distance VA only.

Expected Outcomes S P E C I F I C A T I O N S S P E C I F I C A T I O N S Product Specification for all Crystalens Models: Optic : 5.0 mm Shape: Biconvex Material: Biosil Crystalens AO Model Recommended Starting A Constant Recommended Starting ACD Overall AT50AO 119.1 5.61 mm 11.5 mm AT52AO 119.1 5.61 mm 12.0 mm Diopter Power +17 to +33 +18 to +22 +10 to +16.50 Biconvex Shape 2.75 mm Plate 10.5 mm Overall 11.5 mm and 12.0 mm HD500 118.8 5.43 mm 11.5 mm 10 +18 to +22 11 Crystalens HD HD520 118.8 5.43 mm 12.0 mm +17 to +33 +10 to +16.50 Biosil Optic Optic 5.0 mm Crystalens Five-O AT50SE 119.0 5.55 mm 11.5 mm AT52SE 119.0 5.55 mm 12.0 mm +17 to +27 +27 to +33 +4 to +10 in 1.0 steps +10 to +16 +16 to +16.75 Polyimide call for our quick-start kit for more information call: 1-800-338-2020 FOR CLINICAL SUPPORT CALL: 1-888-393-6642