kvue IGRT Couch top One couch top, multiple treatment solutions For Varian, Elekta, Siemens, Proton and more The Best of Both Worlds

Similar documents
Patient Positioning Products

Absorption measurements for a carbon fiber couch top and its modelling in a treatment planning system

Treatment Planning Techniques for Larger Body Habitus Patients for Breast/Chestwall and Regional Lymph Nodal Irradiation

SnapShot IMRT with compensators and FFF beams

Outline. Chapter 11 Treatment Planning Single Beams. Patient dose calculation. Patient dose calculation. Effect of the curved contour surface

TEST REPORT BEAMSCAN WITH HALCYON

CHAPTER 4 PRE TREATMENT PATIENT SPECIFIC QUALITY ASSURANCE OF RAPIDARC PLANS

IMRT in clinical practice at the UMC-Utrecht. Utrecht

13 QUALITY ASSURANCE OF A LINEAR ACCELERATOR 13.1 COLLIMATOR ISOCENTER, JAWS, LIGHT FIELD VS INDICATORS, COLLIMATOR ANGLE INDICATORS.

Monitor Unit Calculations Part 1. Return to our first patient. Purpose. 62 yr old woman with Stage IIIB (T1N3M0) NSCLC rt lower lobe Dose prescription

Zoubir Ouhib Lynn Cancer Institute

Exradin Ion Chambers. What attributes make Exradin the smart choice? EXRADIN Ion Chambers

CLINICAL IMPLEMENTATION OF RAPIDARC Treatment Planning Strategies to Improve Dose Distributions

Commissioning an IMRT System for MLC Delivery. Gary A. Ezzell., Ph.D. Mayo Clinic Scottsdale

TG-119 IMRT Commissioning Tests Instructions for Planning, Measurement, and Analysis Version 10/21/2009

Introduction. Introduction. The CyberKnife SRS/SBRT System. Introduction. Contour Structures. CyberKnife Components

VariSource High Dose Rate Afterloader Procedures. For Performing Breast Brachytherapy with. The SAVI TM Applicator

Proton Therapy QA Tools

Planning Assignment (3 field rectum)

Basics of Proton Therapy. Proton Treatment Planning and Beam Optimization

RESPIRATORY MOTION IN RADIATION THERAPY

RADIOLOGY/ FLUOROSCOPY 15 RAD-CHECK PLUS X-RAY EXPOSURE METER

Orfit Products. Contribute Significantly to an Excellent Therapy Outcome

THE development of more advanced techniques in radiotherapy,

Clinical Implementation of Volumetric Modulated Arc Therapy

Breast Treatment System REFERENCE MANUAL


Review of fundamental photon dosimetry quantities

Disclosures. What Is So Hard? End of ITV: Gating is the Best ITV Killer 8/3/2016. Daniel A. Low, Ph.D. UCLA. Varian Grant Siemens Grant Accuray Grant

Electronic Oncology Systems the Management and the Safety Measures. Hansen Chen, Director, TDSI

Ultra Lightweight Family

Shandon Cryotome Cryostat Series

Commissioning and quality assurance of a commercial intensity modulated radiotherapy (IMRT) treatment planning system PrecisePLAN

Radiotherapy physics & Equipments

Clinical Implementation of the TG-51 Protocol. David Followill Radiological Physics Center Houston Texas

3D Treatment Planning and verification with hand calculations

The Royal Australian and New Zealand College of Radiologists. FRANZCR Examination Part I Radiation Oncology. Radiotherapeutic Physics.

The All New DIAMOND & DIAMOND BT

Introducing Astral. Greater freedom. Confident care. Designed efficiency

ANALYSIS OF OFF-AXIS ENHANCDED DYNAMIC WEDGE DOSIMETRY USING A 2D DIODE ARRAY A CREATIVE PROJECT (3 SEMESTER HOURS) SUBMITTED TO THE GRADUATE SCHOOL

High Speed Direct SAD Radiosurgery Beam Scanner

Dosimetric Calculations. Lonny Trestrail

TRAM by Rifton. Always Supportive... Transfer and mobility device designed to deliver three powerful functions in one compact unit. jiraffe.org.

Ultra Lightweight Family

Math Review. Overview

Quantum 1450 Group 3 Very Heavy Duty Synergy and Captain s Seating Order Form Up To 600 lbs. Weight Capacity

Commissioning of Elekta 6MV FFF Versa HD and Pinnacle

Commissioning and periodic tests of the Esteya electronic brachytherapy system

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Monitor Unit Verification for Small Fields

Only 8% to go. TOTAL 1494 of 1623 ACTIVE INSTITUTIONS (92%) May-09. May-04 Nov-04. May-07. Nov-02 May-03. Nov-05. Nov-06. Nov-07 May-08.

IEC C LASSIFICATIONS:

Monitor Unit Calculations Part 2. Calculation of machine setting. Collimator setting

Relative Dosimetry. Photons

Constancy checks of well-type ionization chambers with external-beam radiation units

GEANT4 SIMULATION OF AN ACCELERATOR HEAD FOR INTENSITY MODULATED RADIOTHERAPY

Inspire rpap REVOLUTION FROM THE FIRST BREATH

Comparison of ionization chambers of various volumes for IMRT absolute dose verification

Ultra Lightweight Family

Unit shown in luffer configuration

ZIPWAKE DYNAMIC TRIM CONTROL SYSTEM OUTLINE OF OPERATING PRINCIPLES BEHIND THE AUTOMATIC MOTION CONTROL FEATURES

BETTER PRODUCTS for BETTER CARE

Account Number: Provider Name: Contact Name: Phone #: Fax #: Address: Taken By: Client Height: Client Weight:

Trim and Stabilisation systems NEXT GENERATION IN BOAT CONTROL.

ACID FAST BACTERIA MICROBIOLOGY STAINER / CYTOCENTRIFUGE WESCOR, INC

RIK Fluid Overlay INSTRUCTIONS FOR USE

Heavy-duty power for the most demanding jobs

THERMOPLASTIC FIXATION MASKS

250 ton mt Lattice Crawler Crane

TT TORQUE WRENCHES. TTi TORQUE WRENCHES. For no-nonsense torqueing - comfortable, accurate and easy to use

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New

QUICKWALL OPEN STORAGE SYSTEM. Complete Storage & Workspace Solutions

HumiSys HF High Flow RH Generator

Defibtech s Latest Advancement The Lifeline ARM Automated Chest Compression (ACC) Device for Professionals

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 3, NUMBER 4, FALL 2002

The ESS neutron bunker design, materials and timeline.

Agilent Wedge for Probing High-Pitch ICs A Hands-Free Solution for Probing Fine-Pitch ICs

Optimized Resuscitation. Cardiac massage and ventilation. Ideen bewegen mehr.

JAY J3 Backs We ve Got Your Back

Dräger PSS 3000 Self-Contained Breathing Apparatus

Vibration isolated tables. Individually tailored to your requirements.

Physics and Quality Assurance

Sunrise Medical 7477 East Dry Creek Parkway Longmont, Colorado In Canada:

3M Steri-Vac Sterilizer/Aerator GSX Series. For Life Science Applications. Product. Profile

ALPHA TETRA Stencil Frame System

BETTER PRODUCTS for BETTER CARE

INGLESE - COD

MPG-plus. Application example. Pneumatic 2-Finger Parallel Gripper Gripper for small components. Gripping force 38 N 175 N. Sizes

Emergency Transport and Ventilation

FREQUENTLY ASKED QUESTIONS

GE Healthcare. Aestiva/5. More than superior ventilation

Exposure System Selection

PWG-S. Application example. Pneumatic 2-Finger Angular Gripper Universal Gripper. Sizes. Gripping moment 5.98 Nm Nm. Weight 0.21 kg 1.

color: black/red clearcoat: matte/gloss 2014 collection

P R I M A X. The Most Advanced Shoring Devices SAFER - FASTER - DEEPER - CHEAPER THE ULTIMATE SHORING TECHNIQUES ARE NOW ON YOUR HANDS

AN EXCITING NEW CONCEPT MICROBIOLOGY SLIDE STAINER/ CYTOCENTRIFUGE BIOMEDICAL PRODUCTS WESCOR, INC

ELECTRON PRO: ASSEMBLY GUIDE. Revision Valid for MY2017 Electron Pro

110-ton (99.97 mt) Lattice Boom Crawler Crane

Experience the Flow. Streamlined workflow with the compact Flow-c

Treatment plan complexity metrics for predicting IMRT pretreatment. assurance results. Scott Crowe, QUT

Transcription:

TM kvue IGRT Couch top One couch top, multiple treatment solutions For Varian, Elekta, Siemens, Proton and more kvue The Best of Both Worlds

kvue IGRT COUCH TOP One couch top, multiple treatment solutions The kvue Couch top is a state-of-the-art radiotherapy couch top optimized for the most recent advances in technology to guide your patient from simulation through treatment. Wide variety of interchangeable inserts to form one versatile couch top device Quickly and easily secure couch top inserts with OneTouch latch system Low attenuation and surface dose Virtual Indexing ensures precise, repeatable patient positioning every time Minimal artifacting under Cone Beam CT kvue IGRT COUCH TOP Multiple inserts for a variety of treatments The kvue is designed for superior performance when used with kilovoltage imaging, such as cone beam CT, while simultaneously reducing skin dose for treatments that pass through the couch top. Combined with the ability to replace the kvue Standard Couch top Insert with modular immobilization devices, this makes the kvue one of our most advanced solutions available for IMRT and IGRT. kvue inserts have attenuation as low as 2.0 mm @ 6 MV. 2 Complete range of interchangeable couch top inserts

Non Artifacting (Stealth Beam) Artifacting (Traditional) IMAGING INFORMATION Design provides excellent quality images The entire cantilevered section of the kvue is radiolucent and meets IEC and FDA requirements for attenuation. The design provides excellent quality images for kilovoltage imaging using standard x-ray and cone beam CT as well as portal imaging using MV energies. Cone beam CT image compares the imaging properties of the kvue Stealth Beam (left) with the support beam from a traditional couch top (right). kvue Stealth Beams Positioned to avoid critical treatment areas With most kvue Inserts, the support beams can be laterally repositioned with the patient on the couch top. The Stealth Beam design virtually eliminated the artifacts that are usually associated with beamstyle couch tops. This new beam design also reduces attenuation and surface dose if treating through the support beams. While it is recommended that the beams are positioned in the inner or outer position to completely avoid critical treatment areas, the actual location of the beams is infinitely variable. ONETOUCH LATCH Allows secure interchanging of the insert The kvue features the exclusive OneTouch Latch, which allows an array of kvue inserts to be quickly attached and easily secured with zero movement for a variety of treatment solutions. The kvue inserts provide the functionality of an integrated device, enabling precise, repeatable sub-millimeter patient positioning every time. 3

COMPLETE LINE OF COUCH TOP INSERTS Multiple treatment solutions kvue Standard Insert Provides versatility for a wide range of treatments The kvue Standard Insert is a versatile insert for everyday treatments. The standard insert is stiffer than grid inserts to prevent sagging and extends beyond the end of the beams. RT-4551KV1 Length: 1325 mm Water Equivalence: 6 mm @ 6 MV kvue DoseMax Insert Rigid insert with excellent skin sparing properties RT-4551KV5 Our lowest attenuation rigid insert Our DoseMax low-electron generation rigid couch top insert combines the rigidity of a solid panel insert with skin-sparing properties that are comparable to a grid panel insert. Length: 1325 mm Water Equivalence: 2.0 mm @ 6 MV mm 12 10 8 6 4 2 0 Water Equivalence 8-12 Monocoque Couch 6 Solid Insert 2 DoseMax Insert kvue Universal Tip Insert Allows mounting of a variety of accessories 4 RT-4551KV8 The kvue Universal Tip Insert allows mounting of QA and treatment devices. It provides universal mounting capability for all Varian Exact style tip accessories. Length: 950 mm Water Equivalence: 6 mm @ 6 MV Weight Limit: 38.5 (85 lb) @ 25 cm extended from front edge 249 kg (550 lb) over kvue Insert and Back Panel

kvue Access 360 Prone Breast Insert* Near 360 degree access for treatment is unparalleled The kvue Access 360 is designed to allow breast cancer treatment for both left and right breast. By positioning the patient over the breast opening, beyond the support rails, it enables maximum visual and treatment access to the breast. This insert also provides access to treat the supraclavicular nodes in the same setup. * only available as a complete package including right and left breast insert, 2 headrests (1 Prone and 1 Contour), 3 hand grips (1 Dual and 2 Hand Grip Posts), 1 set of CT risers with stackable riser shims, and 1 storage cart RT-4544KV CT Risers for Simulation kvue Stradivarius SBRT Insert Offers complete patient immobilization The Stradivarius SBRT system is a complete solution for hypofractionated non-coplanar treatment. The hour glass design allows for unobstructed treatment paths. Bridges are available in two sizes and are adjustable in height. The abdominal compression paddle is also fully adjustable at the touch of a button to reduce thoracic movement. Length: 1320 mm Water Equivalence: 6 mm @ 6 MV RT-4558KV1 Large & Small Bridges available 5

kvue AccuFix Cantilever Insert - Featherline Edition Provides optimum localization for head & neck RT-4525KVL The AccuFix Cantilever Board is designed to immobilize the head, neck and shoulder regions. It is intended to provide optimum localization for the patient in the supine and prone positions. Length: 1368 mm kvue Portrait Insert Provides superior immobilization for a variety of treatments RT-4552KV The kvue Portrait Insert offers patient immobilization using S-Frame masks. Length: 1328 mm Water Equivalence: 6 mm @ 6 MV RT-4535KV kvue BoS Insert Unique design does not block important beam angles The kvue BoS Insert is specifically designed to meet the requirements of proton therapy for patient immobilization and beam transmission. The contoured design minimizes the distance between the patient and the field defining aperture, optimizing the beam proton penumbra. Length: 1325 mm Weight Limit: 159 kg (350 lb) kvue Short Insert Allows for the mounting of overlay cantilevered devices RT-4551KV2 The kvue Short Insert is a shorter flat panel insert that allows the couch top to be retracted far enough away from the gantry to extend a cantilevered headboard under the isocenter. Length: 959 mm Water Equivalence: 6 mm @ 6 MV kvue PentaFix Insert Uses a 5-point mask system for a variety of treatments RT-4549KV 6 The kvue PentaFix Insert offers patient immobilization using 5-point fixation masks. Length: 1325 mm Water Equivalence: 6 mm @ 6 MV

kvue COUCH TOP - CALYPSO COMPATIBLE Varian, Elekta & Siemens compatible kvue Calypso Inserts are also available kvue IGRT COUCH TOP ACCESSORIES Accessories are available for your kvue COUCH TOP INSERT STORAGE CART The Couch top Insert Storage Cart stores Couch top Inserts and Qfix free-standing devices to help organize your treatment room. Lockable caster wheels allow you to roll the cart up to the couch top. kvue SERVICE PANEL The Service Panel is designed to sit on top of any couch top that uses Varian Exact indexing. When placed on top of the couch top, it protects the surface during such activities as routine Linac maintenance and water phantom tank calibration. 7

COUCH TOP INSERTS BACK PANELS kvue Access 360 Prone Breast Insert RT-4544KV Indexing Back Panel RT-4551KV0 kvue Standard Insert RT-4551KV1 Back Panel RT-4551KV0-N kvue AccuFix Cantilever Insert - Featherline Edition RT-4525KVL kvue Portrait Insert RT-4552KV kvue DoseMax Insert RT-4551KV5 Base Frame RT-4551KV kvue Universal Tip Insert RT-4551KV8 INTERFACE PLATES kvue Short Insert RT-4551KV2 Siemens ZXT RT-4551KVA-ZXT kvue BoS Insert RT-4535KV Elekta Precise RT-4551KVA-ELK kvue Stradivarius SBRT Insert RT-4558KV1 Siemens TXT RT-4551KVA-TXT kvue PentaFix Insert RT-4549KV Varian ETR RT-4551KVA-ETR 8

kvue kvue COUCH TOP DIMENSIONAL SPECIFICATIONS with Standard Couch top Insert The Best of Both Worlds DEFLECTION Exceeds deflections specification standards When mounted to the Varian Exact Couch Base, the kvue Couch top meets the deflection requirements of IEC 60976[2007] Section 16.5.2.2. VIRTUAL INDEXING Fiducial markers ensure accurate positioning Virtual Indexing provides a way to quickly ensure that the treatment couch is in the same position as the simulation couch by using an array of white fiducial markers that are placed down the center of the couch. A second array of adjacent diagonally offset fiducial markers are used to designate the superior or inferior location of the markers in relationship to the indexing origin. This helps ensure accurate patient positioning and speeds patient throughput. Fiducial Markers Virtual Indexing 9

kvue CT OVERLAYS Complete Simulation through Treatment Options kvue TM The Best of Both Worlds From Simulation & Planning To Treatment The kvue CT Overlay provides new possibilities for Simulation and Planning. The kvue CT uses the upper 25 mm (1 in.) of the kvue Treatment Couch top and accepts the same couch top inserts. Therefore it has the same geometry and dosimetric properties as the kvue Couch top. During treatment and planning, you no longer have to estimate a correction factor for the attenuation (and electron generation) caused by the treatment couch top. The couch top and devices are now in your planning data set. Most kvue Couch top Inserts can be used with kvue CT Overlays RT-4550KVGEL RT-4550KVGER RT-4550KVGEC RT-4550KVPBR RT-4550KVSS1 RT-4550KVSS2 RT-4550KVSS3 RT-4550KVTAQ kvue CT Base for GE Lightspeed and HiSpeed CTi CT Scanners (for 231 cm long cradle) kvue CT Base for GE Lightspeed RT CT Scanner (for 207 cm long cradle) kvue CT Base for GE Lightspeed VCT Scanner (for 262 cm long cradle) kvue CT Base for Philips Brilliance CT Scanner (for 250 cm long cradle) kvue CT Base for Siemens Somatom Plus 4, Somatom Volume Zoom/Access, and Sensation Scanners for 244 cm long cradle) kvue CT Base for Siemens Somatom Balance, Emotion or Espirit Cradles (217 cm long) kvue CT Base for Siemens Somatom Definition (for 240 cm long cradle) kvue CT Base for Toshiba Aquilion CT scanner (for 215 cm long cradle) 10 Lead times may vary, please call for availability.

QUANTUM CT OVERLAYS Available for GE, Philips, Siemens and more... Theirs Ours 3.5 cm (1.4 in) Improved Field of View The entire QUANTUM overlay rests above the plane of the cradle. This facilitates the digital removal of the cradle for treatment planning purposes. The geometry and physical construction of the QUANTUM CT Overlay is designed to mimic the QUANTUM Treatment Couch top that is essential in treatment planning. At 51.4 cm (20.25 in.) wide and 1.6 cm (5/8 in.) thick, this overlay is narrower and thinner than most other indexed CT overlays. The thinner profile, coupled with its patent pending chamfered edge indexing design, allows the cradle to be positioned up to 3.5 cm lower in the bore, thus significantly increasing the field of view. RT-4550GEH RT-4550GEL RT-4550GEL RT-4550GEP RT-4550GEC RT-4550GER RT-4550GEDLS RT-4550PBR RT-4550PQ RT-4550PQ RT-4550SS1 RT-4550SS2 RT-4550SS2 RT-4550SS2 RT-4550SS2 RT-4550SS1 RT-4550SS1 RT-4550SS1 RT-4550SS3 RT-4550SS4 RT-4550TAQ Overlay - GE HiSpeed (for 219 cm long cradle) Overlay - GE HiSpeed CTi (for 231 cm long cradle) Overlay - GE LightSpeed (for 231 cm long cradle) Overlay - GE ProSpeed (for 207 cm long cradle) Overlay - GE LS VCT (for 262 cm long cradle) Overlay - GE LightSpeed RT (for 207 cm long cradle) Overlay - GE Discovery LS (for 266 cm long cradle) Overlay - Philips Brilliance (for 250 cm long cradle) Overlay - Picker PQ Series (2000 & 5000) (for 239 cm long cradle) Overlay - Philips AcQsim (for 232 cm long cradle) Overlay - Philips Picker MX8000 (for 244 cm long cradle) Overlay - Siemens Somatom Balance (for 217 cm long cradle) Overlay - Siemens Somatom Emotion (for 217 cm long cradle) Overlay - Siemens Somatom Emotion Duo (for 217 cm long cradle) Overlay - Siemens Somatom Esprit+ (for 217 cm long cradle) Overlay - Siemens Somatom Plus 4 (for 244 cm long cradle) Overlay - Siemens Somatom Sensation 4/16 (for 244 cm long cradle) Overlay - Siemens Somatom Volume Zoom/Access (for 244 cm long cradle) Overlay - Siemens Somatom Definition 64 (for 240 cm long cradle) Overlay - Siemens Somatom Definition AS Open (1600/PHS1B) Overlay - Toshiba Aquilion (for 215 cm long cradle) * Lead times may vary, please call for availability. 11

M060 Rev 8/13 kvue, OneTouch, Virtual Indexing, DoseMax, Universal TIP, Access 360, Stradivarius, AccuFix, CURVE, BoS, Pentafix, and QUANTUM are trademarks of Qfix Systems. Exact is a trademark of Varian Medical Systems. Brilliance, AcQSim, Gemini Picker PQ 2000/5000 are trademarks of Philips Medical Systems. HiSpeed and LightSpeed are trademarks of GE Medical. Somatom is a trademark of Siemens AG. Calypso is a registered trademark of Calypso Medical Systems. Qfix Avondale, PA +1 610-268-0585 sales@qfix.com www.qfix.com TM