Ultrasonic Wind Sensor

Similar documents
Ultrasonic Wind Sensor

EPP4 Pressure Regulator Basic G 1/4"

Actual Size. WX Series Ultrasonic WeatherStation Instruments

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

GasSense NDIR User Manual

Mass Flow Meter (MFM) for gases

SonoMeter 30 Energy Meters

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

QPL... Pressure Switches. Siemens Building Technologies HVAC Products

Precision pressure sensor Basic version Model CPT6020

PTB210 Series Digital Barometers with Analog Output USER'S GUIDE

Model PDT Dewpoint Transmitter

Vortex Flow Sensor VA Di Ex-d for flow measurement in gases; with integrated, configurable transducer UVA in Ex-d housing

Differenz-Drucktransmitter Differential pressure transmitter Transmetteur de pression différentielle bar

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

User s Guide. Pressure Controller for liquid delivery systems

PyroCouple Series Operators Guide

USER'S GUIDE. Digital Barometers with Analog Output PTB210 Series M210670EN-B

Air Bubbler Depth Gauge DG2200 Installation and Reference Manual

Thermal flow sensor TA Di with integrated transducer for measuring mass flow, standard flow rate and air / gas consumption

Target disk flowmeter Series DP. Instructions manual DP65 DP500. R-MI-DP Rev.: 4 English version

Digital electro-pneumatic regulators Series ER100

Relative pressure switch type 521

Mass Flow Meter (MFM) for Gases

NOVALYNX CORPORATION MODEL BAROMETRIC PRESSURE SENSOR PCB MODEL BAROMETRIC PRESSURE SENSOR IN NEMA ENCLOSURE INSTRUCTION MANUAL

MASS-STREAM TM Instruction Manual. D-6200 Analog Mass Flow Meters / Controllers

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

Model 6810A Dual Lane Scoreboard Owner s Manual Rev B

LK-SX VOC. Application. Security Advice Caution. Notes on Disposal. Combined sensor mixed gas. Data sheet

2/ Port G1/4

Electronic relative and differential pressure switch type 616

Mass Flow Controller (MFC) for Gases

Fixed Ozone Monitor User Manual December, Automatikprodukter

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

Relative and differential pressure transmitter type 692

Transmitter CS 21 Operation Manual

Sensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual

Transmitter CS 21 Operation Manual

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

FL200 Monochromatic Architectural Spot and Floodlight

USER'S GUIDE. Vaisala CARBOCAP Carbon Dioxide Calibrator for the GMP220 series probes GM K220 U421EN-1.1

INTRODUCTION TO NETWORK WIND 3 MOUNTING THE UNIT 14 SELECTING THE DISPLAY MODE 5 ABBREVIATIONS AND DEFINITIONS 17

HUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1

AUTO PUMP STATUS CENTER

SDI mA Pressure Transducer (Submersible + Dry) Model WL2100 Operating Manual

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners

Operating Instructions Temperature Measuring System MF420-5T-100

METEOR LSR36500 LIGHTING UNDERWATER POOL LIGHT. Operating Instructions

Features. Description

Depth sensor. Product reference : REV 1. USER GUIDE and INSTALLATION GUIDE. nke Sailing competition

Visualize Nitrogen Gas Consumption

Pneumatic high-pressure controller Model CPC7000

Ultrasonic level transmitter and indicator

TECNAUTIC_GmbH. Display Functions with the PB100/200 connected: -- GND Speed -- GND Course -- Heading (Gyro option is recommended) 2 m

SVEA II GSM Connector User Manual

PLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions

Operating instructions Installation instructions To be kept in the vehicle!

Hand-held pressure calibrator with integrated pump Model CPH6600

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

Technical Data. Dimensions

Operating Instructions Melt Pressure Sensor

C-Flow Coriolis Mass Flow Meters

Mass Flow Controller (MFC) for Gases

GAS FUEL VALVE FORM AGV5 OM 8-03

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Sensoric 4-20 ma Transmitter Board Operation Manual

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Installation and Operation Manual

Bypass Mass Flow Controller (MFC) for gases

Torque Tube TB300 Digital Transmitters

SP-110 Autopilot OPERATION

INSTALLATION INSTRUCTIONS AND REFERENCE HANDBOOK

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids

Mass Flow Controller (MFC) for Gases

Expert Hydrostatic Level Transmitters

Model 4140/4143 General Purpose Thermal Mass Flowmeter

User s Guide. Vacuum Controller for liquid delivery systems

Model 6812C Dual Lane Scoreboard Owner s Manual

OXY 3690 MP. Measuring transducer for air oxygen

INSTALLATION & MAINTENANCE INSTRUCTIONS

QUICK START GUIDE CB-450 DATA BUOY PLATFORM

AP55 Display OPERATION AND INSTALLATION MANUAL.

USER'S GUIDE. Digital Barometers with Serial Output PTB210 Series M210669EN-D

High-performance submersible pressure transmitter For level measurement Model LH-20

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual

KMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N

RG2 Gripper Datasheet Version 1.6

Mass Flow Controller (MFC) for gases. Inline MFC for nominal flow rates from 25 I N. /min to I N

Installation and Operation Manual

Instruction Manual BA90 Precision Barometer

APPLICATION NOTES. WIND MEASURING SYSTEMS using XDi-N indicators. Document no.: B

Electronic gas volume corrector model DGVC-04

Technical Data. Dimensions

Transcription:

CV7-L Ultrasonic Wind Sensor Page 1 of 8

1. Installation Prepare the mast head for the mechanical installation. Use the template for the bracket s screwing. Align the bracket in order to have the CV7-L sensor heading to the bow while the mast is aligned to the North. The sensor s fine alignment will be obtained with the software calibration application. Run the cable down to the display s interface, avoiding locations where other cables or equipment may produce electromagnetic interferences. Sensor view from below Bracket mounting template Note : for mounting on vertical surface, the brackets RA106BRACKET and RA106BRACKINOX from Glomex are compatible. (see the example picture, not supplied) Page 2 of 8

2. Wind sensor alignment and configuration CV7-L is delivered with the following configuration : NMEA0183 Filtering: 2 s Forces of wind unity : Nds Temperature unity: C Adjustment of the angle of the wind: 0 To choose other parameters, use the downloadable software on this website: www.lcjcapteurs.com. «Configuration_CV7». Realise the following connexions (only for configuration): Red cable Blue cable Yellow cable Green cable + power - power 3,3 Kohm SubD 9 points 5 2 3 Page 3 of 8

3. Interconnections NMEA 0183 Realise the following connexions: - For RS232 Type PC input Power supply connections 12V (8 à 30 VDC). Wire Blue - / Wire Red + Red Blue Yellow Green + Power supply 0V + NMEA - NMEA N.C. PC SUBD 9 Pts Plug Type COM1 Soldered side SubD 9 points 5 2 1 2 3 4 5 - For NMEA 183 standard input ( RS422) 6 7 8 9 Power supply connections 12V (8 à 30 VDC). Wire Blue - / Wire Red + Red Blue Yellow Green + Power supply 0V + NMEA - NMEA Rx + Rx - Typical diagram NMEA 0183 to use a long cable. Page 4 of 8

4. CV7-EL Technical Specifications: Wind speed range 0.25-45 m/s (0.56-100 MPH) Wind speed resolution 0.1 m/s (0.22 MPH ) Wind speed sensitivity 0.13 m/s (0.29 MPH) Independent of weather conditions Wind direction range 0-359 Wind direction resolution 1 Wind direction sensitivity +/- 1 Power requirement 8 V to 33 V DC Power consumption 9 ma Dimensions / Sensor Cylinder Ø 64 mm - height 61 mm Boot up delay 4 seconds Cable 5 m standard delivery (approx.16') Arm Aluminium, 300 mm Cable weight 20 gr/m Weight / Sensor + arm and base 200 gr Weight / Sensor 100 gr Operational temperature 5 F to +131 F (without iceing) Environement Sensor IP67 CE Mark EN 55022 EN 55024 Typical wind tunnel report (see : http://www.lcjcapteurs.com/know/quality_anemometer/?lang=en ) Page 5 of 8

5. NMEA0183 protocol: Baud rate 4800, data bit 8, parity none, stop bit 1 Flux every 533 milli-second Variable lenght fields, delimiter «,». Start of sentence : $ End of sentence : CR,LF Voltage outputs: 0 or 5V Symmetrical outputs Examples : $IIMWV,225.0,R,000.0,N,A*38 $WIXDR,C,022.0,C,,*52 $PLCJ,5801,5F01,AA,4253,3341 $PLCJEA870,6D98,C500,0056,AC, Wind angle 000.0 to 359.0 Relative reference Sentence formatter Wind $IIMWV,225.0,R,000.0,N,A *38 Wind speed Wind speed unit N = knots, M= m/s, K=km/h CheckSum Status of CV3F A : available, V=Alarm Sentence formatter Temperature of wind Temperature Unit of measure C = Celsius, F= Fahrenheit $WIXDR,C,022.0,C,,*52 CheckSum $PLCJ,AAAA,BBBB,CC,,,,DDDD,EEEE $PLCJEFFFF,GGGG,HHHH,IIII,JJ Sentences for LCJ CAPTEURS technical service Page 6 of 8

6. Dimensions Ø 63 mm 61 mm 371 mm Ø 16 mm Page 7 of 8

7. Warranty Your CV7-L is warranted against manufacturing defects in materials and workmanship for a period of 2 years from the date of purchase. LCJ Capteurs will at its discretion, repair or replace faulty product free of charge excluding the cost of shipping. Proof of purchase shall be required in order for a warranty claim. All claims shall be made in writing to LCJ Capteurs and once it is accepted by LCJ Capteurs, the faulty product must be sent to LCJ Capteurs address in Vertou, France. Note: The wind sensors are mounted on an arm of 16 mm diameter by 15 cm length for factory calibration. It is your responsibility to evaluate the changes in air flow out of these conditions. For further information, please visit www.lcjcapteurs.com where video presentations are available. EN 55022 EN 55024 Remember to respect the local regulations: dispose non-working electronic equipment to an appropriate waste disposal center. Page 8 of 8