Propor tional Re lief Valve s

Similar documents
Proportional Relief Valves

Proportional Relief Valves

HIGH-PRESSURE RELIEF VALVES

INDUSTRIAL EXCESS ESS FLOW VALVES

INSTRUMENTATION VALVES

Tank Blanketing Pressure Regulators RHPS Series

shutoff valves 900 Series psig Manual Shutoff Valves

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

VCO O-ring Face Se al Fit tings

LRS(H)4 Pressure-Reducing Regulator User Manual

RHPS Series PRV 2 all types of connections User Manual

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

RHPS Series PRV 6 User Manual

RS(H)20, 25 USER MANUAL

RD(H)20/25 Pressure-Reducing Regulator User Manual

relief valves R6000 Series

HIGH-PRESSURE RELIEF VALVES H-900HP SERIES

Sample C ylinde rs, Acce ssorie s, and O utage Tube s

relief valves Circle Seal Controls 2301 Wardlow Circle Corona, CA Phone (951) Fax (951)

Go to Table of Contents. Ball and Plug Valves

CASH VALVE TYPE KP BACK PRESSURE VALVES

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Products Compliant with the Transportable Pressure Equipment Directive (TPED)

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Si C132. Safety valves for pressure relief in accordance to PED, DIN/EN and ASME. Engineering GREAT Solutions

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Homestead Series 820 AWWA Butterfly Valves

G type DUCTED EXHAUST SAFETY VALVE 2871 AND 288X SERIES. Model/Ref:

High-Purity. Ball Valves

WaterSource Heat Pump Hose Kit Performance Specification-Summary

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

COMBINATION AIR RELEASE DEGASSING (CARD) VALVES INSTALLATION AND MAINTENANCE MANUAL

Horizontal Bladder Tanks

Sample Cylinders and Accessories

Vertical Bladder Tanks

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

627 Series Pressure Reducing Regulators

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

relief valves Relief Valves Index 500 Series 1 L500 Series 7 HP500 Series Series 11 D500/M5100 Series Series 21 R6000 Series 25

High-Flow, Manual Gas Pressure Regulators

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

Series V47 Temperature Actuated Modulating Valves

excellence of Italian engineering Field adjustable PRESSURE RELIEF VALVES

Installation, Operation and Maintenance Manual for Back Pressure Regulator

VERTICAL BLADDER TANK

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

Sample Cylinders and Accessories. Catalog 4160-SC Revised, April 2000

Model MTB-ASME Vertical Bladder Tanks

Model 1800 PFM Series Regulator. Technical Bulletin

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

Operation Manual Piston Sensed Gas Pressure Regulators

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Product Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction

Model MTB-ASME Horizontal Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks

Model TB 3-16 TECHNICAL BULLETIN. Secure-Gard Pilot Operated Vent Valve (POVV) BENEFITS TYPICAL APPLICATIONS FEATURES

Type EZH Relief or Backpressure Regulator

CONNECTION > Super-rapid fittings Series 6000 GENERAL DATA. Fitting with connecting tube. Sprint

PRO-50 Instrument Supply Regulator

Type CT88 Backpressure Regulator

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

MERCER VALVE SERIES Pilot Operated THINK...MERCER FIRST MERCER VALVE CO., INC. AUTO SEAT TECHNOLOGY

64 Series Pressure Reducing Regulators

INSTALLATION & MAINTENANCE INSTRUCTIONS

Series V48. 3-Way Pressure Actuated Modulating Valves. Product Bulletin. Features. Pressure balanced design. Free movement of all parts

1200B2 Series Service Regulators. Instruction Manual

COMMITTEE DRAFT. API 520 Part I 10 th Edition Ballot Item 2.1. This ballot covers the following item:

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

1800C and 1800C-HC Series Service Regulators

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

1301 Series High-Pressure Regulators

Anderson Greenwood Series 93 Positive Pressure POSRV Installation and Maintenance Instructions

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

ULTRA HIGH PURITY BELLOWS VALVES. VCB Series.

Type 99 Pressure Reducing Regulators

JSRH Series. Sanitary Valves JSRH Series High Flow Pressure Reducing Valves. High Flow Bio-Pharma Clean Gas Pressure Reducing Valves

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108

1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG

Wheel operated Residual Pressure Valves

Hycocon. Technical information. Das Qualitätsmanagementsystem von Oventrop ist gemäß DIN-EN-ISO 9001 zertifiziert.

TECHNICAL INSTRUCTIONS

GILMONT ACCUCAL FLOWMETERS

TYPE 3710 CARTRIDGE SPLIT SEAL Technical Specification

4/2 way Pneumatic Solenoid Valve

PRESSURE REGULATORS UPSTREAM DIFFERENTIAL PRESSURE. APPLICATION: For maintaining a constant differential pressure across meter.

B34 Series Regulator Commercial and Industrial Regulator

HORIZONTAL BLADDER TANK

Safety Relief Valve HON 832

Regulator from 1800 B series

Avenger Model 33M Installation & Operation Instructions

776 Cryogenic Safety Valve

CSB400 Series Commercial / Industrial Pressure Reducing Regulators

HP/UHP Spring-Loaded Regulator

Gas Pressure Regulator HON 300

1805 Series Relief Valves

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

66 Series Direct-Operated Regulators and Vacuum Service Equipment

V-24 OXYGEN LANCE VALVE

SV5 Safety Valve Installation and Maintenance Instructions

Transcription:

www.swagelok.com Propor tional Re lief Valve s R Series Liquid or gas service Set pressures from 10 to 6000 psig (0.68 to 413 bar) 1/4 and 1/2 in. and 6 to 12 mm end connections

Proportional Relief Valves Spring adjusts to provide desired set pressure Lock nut maintains cap position, ensuring set pressure adjustment Cap provides easy external set pressure adjustment Label identifies set pressure range Lock wire capability secures cap to maintain set pressure adjustment Quad seal eliminates leakage around stem during relief mode O-ring provides elastomer-to-metal seal for positive shutoff at seat. (Other series use bonded disc. See Materials of Construction) series valve shown. End connections include gaugeable tube fittings and NPT or ISO pipe threads Features High-Pressure Valves Service up to 6000 psig (413 bar) Multiple springs for a selection of set pressure ranges 1/4 in. and 6 and 8 mm end connections series 1/2 in. and 12 mm end connections series Low-Pressure Valves Service up to 300 psig (20.6 bar) One spring for the full set pressure range 1/4 in. and 6 and 8 mm end connections series 1/2 in. and 12 mm end connections series Applications R series relief valves are proportional relief valves that open gradually as the pressure increases. Consequently, they do not have a capacity rating at a given pressure rise (accumulation), and they are not certified to ASME or any other codes. Some system applications require relief valves to meet specific safety codes. The system designer and user must determine when such codes apply and whether these relief valves conform to them. Operation R series relief valves OPEN when system pressure reaches the set pressure and CLOSE when system pressure falls below the set pressure. High-pressure and seriesselect and install the spring that covers the required set pressure; apply the matching label to the cap. Low-pressure and seriesthe spring is already installed. For valves not actuated for a period of time, initial relief pressure may be higher than the set pressure.

Technical Data Pressure-Temperature Ratings Proportional Relief Valves 3 Series and Working Pressure at 70 F (20 C) 6000 psig (413 bar); up to 8000 psig (551 bar) during relief 6000 psig (413 bar) 300 psig (20.6 bar) ➀ 50 to 6000 psig (3.4 to 413 bar) 50 to 1500 psig (3.4 to 103 bar) 10 to 225 psig (0.68 to 15.5 bar) Outlet Pressure➁ 1500 psig (103 bar) 2500 psig (172 bar) 225 psig (15.5 bar) Seal Material Fluorocarbon FKM Buna N Neoprene Ethylene propylene Temperature, F ( C) 40 ( 40) 30 ( 34) 10 ( 23) 0 ( 17) 10 ( 12) 6000 6000 25 ( 4) (413) (413) 6000 30 ( 1) (413) 6000 50 (10) (413) 150 (65) 200 (93) 250 (121) 5580 (384) 5160 (355) 4910 (338) 5580 (384) 5160 (355) 4910 (338) 5580 (384) 5160 (355) 4910 (338) 5580 (384) 5160 (355) 4910 (338) Fluorocarbon FKM Neoprene Buna N Maximum, psig (bar) 1500 (103) Ethylene propylene Fluorocarbon FKM Buna N 275 (135) 4660 300 (148) (321) ➀ The pressure-temperature ratings are based upon laboratory testing to ensure that the cracking pressure does not deviate by more than 20 % from the initial room-temperature set pressure. ➁ Outlet pressure should not exceed inlet pressure. 1500 (103) 1500 (103) 1500 (103) 225 (15.5) 225 (15.5) Neoprene 225 (15.5) Ethylene propylene 225 (15.5) and Resealing Pressure Set pressure is the upstream pressure at which the first indication of flow occurs. Set pressure of each valve after initial relief is repeatable within ± 5 % at room temperature. Resealing pressure is the upstream pressure at which there is no indication of flow. Resealing pressure is always lower than set pressure. Testing Every R series proportional relief valve is tested for set and resealing performance. Series,, Test psig (bar) Cleaning and Packaging Minimum Resealing Pressure as a Percentage of, % 10 to 20 (0.68 to 1.3) 50 175 to 225 (12.0 to 15.5) 91 100 to 200 (6.8 to 13.7) 50 850 to 1000 (58.5 to 68.9) 84 All R series relief valves are cleaned and packaged in accordance with Standard Cleaning and Packaging (SC-10), MS 06 62. Back Pressure High-Pressure Valves ( and Series) The effect of system back pressure is minimized by the design of these high-pressure valves. Low-Pressure Valves ( and Series) System back pressure increases the set pressure of the valve. To compensate, multiply the back pressure by 0.8 and subtract the result from the desired set pressure. Use the result to pre-set the valve while back pressure is equal to atmospheric pressure. Example: Desired set pressure is 120 psig. System back pressure is 40 psig. Step 1. Multiply back pressure by 0.8. 40 psig 3 0.8 = 32 psig. Step 2. Subtract result from desired set pressure. 120 psig 32 psig = 88 psig. Step 3. Pre-set proportional relief valve to 88 psig. Oxygen Service Hazards For more information about hazards and risks of oxygenenriched systems, see the Oxygen System Safety technical report, MS 06 13.

4 Proportional Relief Valves Materials of Construction 6 12 13 14 15 only and 9 10 11 1 2 5 7 4 8 3 only 19 12 16 17 18 6 only 12 and 9 10 11 1 5 7 8 2 4 3 only 12a Component 1 Plug Material Grade/ASTM Specification, nickel-plated brass;, brass 2 Cap 316 SS/A479 3 Label Polyester 4 Lock nut, powdered metal 300 series SS/B783;, 316 SS/A276 5 Spring S17700 SS/AMS 5678 6 Sleeve 304 SS/A240 7 Spring support, powdered metal 300 series SS/B783;, 316 SS/A276 8 Bonnet 316 SS/A479 9 O-ring Fluorocarbon FKM 10 Quad seal PTFE-coated fluorocarbon FKM 11 Retainer, 316 SS/A666;, 316 SS/A479 12 Stem 316 SS/A479 12a Bonded stem 13 Bonded disc Fluorocarbon FKM-bonded➀ 316 SS/A479 14 Seat 316 SS/A479 15 Gasket PTFE-coated 316 SS/A240 16 Seat retainer 316 SS/A479 17 O-ring Fluorocarbon FKM 18 Insert 316 SS/A479 19 Body 316 SS/A182 Lubricants Molybdenum disulfide-based dry film and paste; silicone-based Wetted components listed in italics. ➀ Material Safety Data Sheet for bonding agents available on request. 13 19

Flow Data at 70 F (20 C) Air and Series Air Flow, std L/min Water and Series Water Flow, L/min Proportional Relief Valves 5 Inlet Pressure, psig 225 psig (15.5 bar) 150 psig (10.3 bar) 100 psig (6.8 bar) 50 psig (3.4 bar) Inlet Pressure, bar Pressure Drop, psi 225 psig (15.5 bar) 150 psig (10.3 bar) 100 psig (6.8 bar) 50 psig (3.4 bar) Pressure Drop, bar Air Flow, std ft 3 /min Water Flow, U.S. gal/min and Series Air Flow, std L/min and Series Water Flow, L/min Inlet Pressure, psig 5500 psig (378 bar) 4500 psig (310 bar) Inlet Pressure, bar Pressure Drop, psi 5500 psig (378 bar) 4500 psig (310 bar) Pressure Drop, bar 3500 psig (241 bar) Air Flow, std ft 3 /min Air Flow, std L/min Water Flow, U.S. gal/min Water Flow, L/min 3500 psig (241 bar) Inlet Pressure, psig 2600 psig (179 bar) 2000 psig (137 bar) Inlet Pressure, bar Pressure Drop, psi 2600 psig (179 bar) 2000 psig (137 bar) Pressure Drop, bar 1000 psig (68.9 bar) 1000 psig (68.9 bar) Air Flow, std ft 3 /min Air Flow, std L/min Water Flow, U.S. gal/min Water Flow, L/min Inlet Pressure, psig 550 psig (37.8 bar) 350 psig (24.1 bar) 200 psig (13.7 bar) Inlet Pressure, bar Pressure Drop, psi 550 psig (37.8 bar) 350 psig (24.1 bar) 200 psig (13.7 bar) Pressure Drop, bar Air Flow, std ft 3 /min Water Flow, U.S. gal/min

6 Proportional Relief Valves Dimensions Dimensions are for reference only and are subject to change. D Inlet C 0.06 in. (1.5 mm) lock wire hole 0.09 in. (2.2 mm) lock wire hole Outlet A max B E max Low-Pressure Valves ( and Series) End Connections Ordering Dimensions, in. (mm) Inlet/Outlet Size Number A B C D E H tube fittings tube fitting female NPT series: 0.19 in. (4.8 mm) fully open orifice 1/4 in. SS-S4 6 mm SS-S6MM 8 mm SS-S8MM 1/4 in. SS-M4-S4 1/4 in. SS-M4-F4 2.70 (68.6) 1.44 (36.6) 1.19 1.19 Male ISO/ female ISO➀ 1/4 in. SS-M4F4-RT 1.19 tube fittings tube fitting female NPT 1.60 (40.6) 1.60 (40.6) 1.17 (29.7) 1.17 (29.7) series: 0.25 in. (6.4 mm) fully open orifice 1/2 in. SS-S8 12 mm SS-S12MM 1/2 in. SS-M8S8 1/2 in. SS-M8F8 4.09 (104) 1.83 (46.5) 1.83 (46.5) 0.43 (10.9) 0.50 (12.7) 4.14 (105) 5.92 (150) 5.52 (140) 5.52 (140) 4.09 (104) 5.37 (136) High-Pressure Valves ( and Series) Inlet H max 0.06 in. (1.5 mm) lock wire hole 0.09 in. (2.2 mm) lock wire hole Outlet Valve with Manual Override Handle End Connections Ordering Dimensions, in. (mm) Inlet/Outlet Size Number A B C D E H tube fittings tube fitting female NPT series: 0.14 in. (3.6 mm) fully open orifice 1/4 in. SS-4 6 mm SS-6-MM 8 mm SS-8-MM 1/4 in. SS-41 1/4 in. SS-45 2.70 (68.6) 1.44 (36.6) 1.19 1.19 Male ISO/ female ISO➀ 1/4 in. SS-45-RT 1.19 tube fittings tube fitting female NPT 1.60 (40.6) 1.60 (40.6) 1.17 (29.7) 1.17 (29.7) series: 0.25 in. (6.4 mm) fully open orifice 1/2 in. SS-S8 12 mm SS-S12MM 1/2 in. SS-M8S8 1/2 in. SS-M8F8 4.09 (104) 1.83 (46.5) 1.83 (46.5) Dimensions shown with tube fitting nuts finger-tight. ➀ See specifications ISO 7/1, BS EN 10226-1, DIN-2999, and JIS B0203. 0.43 (10.9) 0.50 (12.7) 4.14 (105) 5.92 (150) 5.52 (140) 5.52 (140) 4.09 (104) 5.37 (136)

Proportional Relief Valves 7 Ordering Information Low-Pressure Valves ( and Series) Valve contains spring; set pressure must be adjusted. Select a valve ordering number. Spring Kits Spring kits include spring and installation instructions. Select a spring kit ordering number. Series Spring Kit Ordering Number 177-13K- 177-13K- High-Pressure Valves ( and Series) Valve does not contain spring. Select a valve ordering number and a spring kit ordering number. Spring Kits Spring kits include spring, label, 302 SS lock wire with seal, spring support, and installation instructions. Select a spring kit basic ordering number and add the spring designator for the desired set pressure range. Examples: 177--K1-F 177-13K--C Range psig (bar) Range psig (bar) 10 to 225 (0.68 to 15.5) Spring Designator Spring Color series spring kit: basic ordering number 177--K1-50 to 350 (3.4 to 24.1) A Blue 350 to 750 (24.1 to 51.7) B Yellow 750 to 1500 (51.7 to 103) C Purple 1500 to 2250 (103 to 155) D Orange 2250 to 3000 (155 to 206) E Brown 3000 to 4000 (206 to 275) F White 4000 to 5000 (275 to 344) G Red 5000 to 6000 (340 to 413) H Green series spring kit: basic ordering number 177-13K-- 50 to 350 (3.4 to 24.1) A Blue 350 to 750 (24.1 to 51.7) B Yellow 750 to 1500 (51.7 to 103) C Purple Special Cleaning and Packaging (SC-11) To order R series relief valves processed in accordance with Special Cleaning and Packaging (SC-11), MS 06 63, to ensure compliance with product cleanliness requirements stated in ASTM G93 Level C, add -SC11 to the valve ordering number. Example: SS-S4-SC11 Options and Accessories Seal Materials Fluorocarbon FKM is the standard seal material. Buna N, ethylene propylene, and neoprene are available. To order a valve with an optional seal material, add a valve seal material designator to the valve ordering number. Examples: SS-4-BU SS-S4-BU To order a replacement seal kit, insert a seal kit material designator as a prefix ( series) or suffix (all others) to the seal kit basic ordering number. Examples: BU--K2 SS-3K--BN Series Series Series Series Seal kit basic ordering number SS-3K-- --K2 SS-3K-- SS-3K-- Seal kit contents O-ring, quad seal, bonded disc, retainer, instructions O-rings (2), quad seal, retainer, instructions Manual Override Handles A manual override handle opens the valve without changing the set pressure. For use with: and series standard spring seriesa, B, and C springs only seriesa spring only. Handle diameter is 1.50 in. (38.1 mm). Maximum overall height of valve with handle in closed position: 5.16 in. (131 mm) for and series 6.78 in. (172 mm) for and series. Seal Designator Material Valves Seal Kits Buna N -BU BN➀ Ethylene propylene -EP EP Neoprene -NE NE Fluorocarbon FKM VI ➀ Use BU for series seal kits. O-ring, quad seal, bonded disc, retainer, instructions To order, add -MO to the valve ordering number. Example: SS-S4-MO O-ring, quad seal, bonded stem, instructions Phenolic handle 316 SS pull rod 316 SS spring support Manual Override Handle Kits Series Kits contain handle, pull, rod, spring support, and, instructions. To order, select the desired kit ordering number. Manual Override Kit Ordering Number SS--K5 SS--K5

proportional relief valves should never be used as code safety relief devices. proportional relief valves are not Safety Accessories as defined in the Pressure Equipment Directive 97/23/EC. Safe Product Selection When selecting a product, the total system design must be considered to ensure safe, trouble-free performance. Function, material compatibility, adequate ratings, proper installation, operation, and maintenance are the responsibilities of the system designer and user. Caution: Do not mix or interchange parts with those of other manufacturers. Warranty Information products are backed by The Limited Lifetime Warranty. For a copy, visit swagelok.com or contact your authorized representative. TM Company 001, 2002, 2003, 2004, 2005, 2006, 2007, 2008 Company Printed in U.S.A., MI October 2008, R10 MS-01-141