Pressure-controlled shut-off valve type CNE

Similar documents
Two-stage valve type NE

Pressure-limiting valve and pre-load valve type MVG, MVE and MVP

Hand pump type CH. Product documentation. 300 bar 8.3 cm 3 /stroke. Operating pressure p max : Displacement volume V max stroke :

Pressure-reducing valve type CDK

Pressure reducing valves type CDK

Diaphragm accumulator type AC

Diaphragm accumulator type AC

Over-center valves type LHT with oscillation damping, zero leakage

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES

Pressure reducing valve, direct operated

Pressure reducing valve, pilot operated

Pressure relief valve, direct operated

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Pressure reducing valve, direct operated

Check valve hydraulically pilot operated

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

3-Way Pressure-Reducing Cartridge, Size 2 4

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

Pressure maintenance valve SDV-P / SDV-P-E

Safety and Shut-off Block SAF/DSV

Safety and operating instructions

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

Pressure reducing valve, pilot operated, Model 3DR

Controllers DR, DP, FR and DFR

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

3-Way Safety Block DSV

Operation Manual Air Saver Unit ASV5000 Series

Pressure booster combination DPA-CRVZS. Operating instructions a [ ]

Pressure relief valve, direct operated Type DBD

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

Inverse Proportional Pressure-Relief Cart., Size 2 4

Operating and maintenance manual Filter and reducing station Series / 1.0

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

// ADapters GUIDelines

SATURNSERIES INTERCHANGE > ISO (for the couplings)

Gas Pressure Regulator HON 300

HIGH PRESSURE FILTERS DFDK Series Inline Duplex Filters 4568 psi up to 90 gpm

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type

Cost effective. Smooth. Reliable. LOG Internal Hole Gripper

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

Proportional Throttle Cartridges, Size 16

Safety and Shut-off Block SAF/DSV

Water Safety Shut-off Valve HON 790

2-way flow control valve Model 2FRM 6

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Operating Instructions

Installation Instructions and valve Maintenance Rev. 0 of 21/09/15

Instruction Manual Contact Pressure Vacuum Gauge

Operating Instructions Hand Test Pump BHP 700

Inverse Proportional Pressure-Relief Cart., Size 2 4

180 Series Rotary Shear Directional Control Valve

Installation and commissioning instructions 255 series and 256 series

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Direct Operated Precision Regulator Modular Style. Standard Specifications

MANUAL. Sesame. Thermoplastic Tank Technologies

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

HUPF Series DESCRIPTION APPLICATION INSTRUCTION SHEET GAS PRESSURE REGULATOR WITH INCORPORATED FILTER EN1C-0003NL05 R1205.

Hydraulic Accumulators with Back-Up Nitrogen Bottles

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

FPD20 Series. Gear wheel flow sensor

Electro-Pneumatic Converter YT-940 SERIES

Operating manual for Material pressure tanks Vol./1 and Vol./2

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

Series IRV1000/2000/3000

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

HPB25 Hydraulic Paving Breaker

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

Proportional Pressure-Relief Cartridge Valve, Size 2...4

INSTRUCTION MANUAL Pressure Relief Device LPT

D62 - D63 Directional Control Valve l/min

Electrically Operated Pressure-Relief Cartridge, Size 10

Explanations hydraulic valves TECHNICAL EXPLANATIONS HYDRAULIC VALVES. Contents. 1. Foreword. 2. Characteristic Values

Pressure Reducing Valve DMV 750 set range: bar

Fixed Displacement Motor A4FM

Type 4708 Supply Pressure Regulator

Instruction Manual. CPM-2 Constant-Pressure Modulating Valve IM70775-EN

Inverse Prop. Pressure-Relief Cart., Size 2 4

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

Safety and Shut-off Block SAF/DSV

Type BBS-03, BBS-05, BBS-06, BBS-25

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

Installation and operating instructions KEMPER Backflow Preventer BA Figure 361

Proportional Pressure-Relief Cartridge Valve, Size 2...4

EXH. Specifications. Descriptions. Min. working pressure MPa

Siphon vessel / Priming aid

Inverse Proportional Pressure-Relief Cartridge, Size 10

Filter-Regulator-Lubricator

E 212 E 222 Tank top mounting Connection up to G1¼ Nominal flow rate up to 220 l/min

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS

Transcription:

Pressure-controlled shut-off valve type CNE Product documentation Screw-in valve Operating pressure pmax: Flow rate Qmax: 500 bar 30 lpm D 7710 NE 09-2013-1.3

by HAWE Hydraulik SE. The forwarding and reproduction of this document, as well as the use and communication of its contents, are forbidden unless expressely permitted. Any breach or infringement will result in liability for damages. All rights reserved concerning patent or utility model application. 2/15 D 7710 NE - CNE - 09-2013-1.3 HAWE Hydraulik SE

Contents 1 Overview of shut-off valves type CNE... 4 2 Available versions, main data... 5 2.1 Basic version (screw-in valve)... 5 2.2 Version with single connection block...6 3 Parameters... 7 4 Dimensions... 9 4.1 Basic version (screw-in valve)... 9 4.2 Mounting hole... 10 4.3 Version with single connection block...11 4.4 Tapped plugs... 11 5 Assembly, operation and maintenance recommendations...12 5.1 Intended application... 12 5.2 Assembly information... 12 5.2.1 Screwing in the screw-in valve (basic version)... 13 5.2.2 Adjusting pressure...13 5.2.3 Creating the mounting hole...13 5.3 Directives... 14 5.4 Maintenance information...14 6 Other information...15 6.1 Schematic sectional drawing and connection example... 15 HAWE Hydraulik SE D 7710 NE - CNE - 09-2013-1.3 3/15

1 Overview of shut-off valves type CNE Shut-off valves or accumulator charging valves are a type of pressure control valve. They switch the delivery ow of a pump to unpressurised circulation if the pressure value set is reached. During this process the consumer side is separated from the idle circulation by a zero-leakage check valve. If the pressure drops in the consumer side, the idle circulation is interrupted and the oil fed to the consumer again. Via a control line the higher pressure holds open the pressure-controlled 2 directional valve type CNE and with it the idle circulation. In the low-pressure circuit the valve acts simultaneously as a pressure-limiting valve. The valve type CNE can be screwed-in and can be integrated into control blocks. The necessary mounting holes are straightforward to make. Features and bene ts: Compact design Easily produced mounting hole Intended applications: Accumulator charged systems Jigs Basic version (cartridge valve) 4/15 D 7710 NE - CNE - 09-2013-1.3 HAWE Hydraulik SE

2 Available versions, main data 2.1 Basic version (screw-in valve) Symbol: (detailed) Order coding example: CNE 2 CNE 22 C B - 50-350 - 1/2 Version Table 3 Version with indiv. single connection block Pressure setting (bar) Pressure setting within the various pressure ranges Pressure range Table 2 Pressure range Basic type and size Table 1 Basic type and size Table 1 Basic type and size Basic type and size CNE 2 CNE 21 CNE 23 CNE 22 Flow rate Q max (lpm) 30 Description Shut-off valve Shut-off valve, additional thread seal Shut-off valve, additional thread and piston seal Table 2 Pressure range Basic type and size CNE 2 CNE 21 CNE 23 Pressure range from... to (bar) L M A B C D E 120... 150 95... 120 75... 95 60... 75 45... 60 30... 45 20... 30 CNE 22 -- -- -- 320... 450 150... 320 -- -- HAWE Hydraulik SE D 7710 NE - CNE - 09-2013-1.3 5/15

2.2 Version with single connection block Order coding example: CNE 2 C - 50-1/2 Indiv. single connection block Table 3 Version with indiv. single connection block Pressure setting (bar) Basic type, size and pressure range Pressure setting within the various pressure ranges Table 1 Basic type and size, Table 2 Pressure range Table 3 Version with indiv. single connection block Coding Description Symbol No designation Cartridge valve See Chapter 2.1, "Basic version (screw-in valve)" - 1/2 For pipe connection (G 1/2 (BSPP) ) 6/15 D 7710 NE - CNE - 09-2013-1.3 HAWE Hydraulik SE

3 Parameters General information Description Design Model Material Installation position Pressure-controlled shut-off valve Piston valve Screw-in valve, valve for pipe connection Steel; nitrided valve housing, electrogalvanised sealing nuts and connection block, hardened and ground functional inner parts As desired Ports Port P = input (pump side) Port R = output (re ux p R 50 bar) Port Z = control connection Hydraulic uid Hydraulic oil: according to Part 1 to 3; ISO VG 10 to 68 according to DIN ISO 3448 Viscosity limits: min. approx. 4, max. approx. 1500 mm 2 /s opt. operation approx. 10... 500 mm 2 /s. Also suitable for biologically degradable hydraulic uids type HEPG (polyalkylene glycol) and HEES (synthetic ester) at operating temperatures up to approx. +70 C. Cleanliness level ISO 4406 21/18/15...19/17/13 Temperatures Ambient: approx. -40... +80 C, Fluid: -25... +80 C, Note the viscosity range! Permissible temperature during start: -40 C (observe start-viscosity!), as long as the service temperature is at least 20K higher for the following operation. Biologically degradable pressure uids: Observe manufacturer's specifications. By consideration of the compatibility with seal material not over +70 C. HAWE Hydraulik SE D 7710 NE - CNE - 09-2013-1.3 7/15

Pressure and ow rate Operating pressure Static overload capacity Flow rate p max = 500 bar Approx. 2 x p max tightened and sealing nuts locked Q max = 30 lpm Switching hysteresis Type CNE 2 CNE 21 CNE 22 CNE 23 Approx. 6 bar Approx. 6 bar Approx. 6 bar Approx. 12 bar Leakage Type CNE 2 and CNE 21: There is a slight leakage between the ports Z R and Z P (lowpressure circuit) as a result of the control piston t/thread clearance. It only needs to be taken into account in the case of a direct connection to the consumer without a directional valve in between. Leakage ow Z P(R) (cm 3 /min) CNE 2 CNE 21 p Z = 200 bar 100 55 p Z = 500 bar 250 160 Weight Basic version Type CNE.. = 0.2 kg With single connection block -1/2 = 0.45 kg Characteristic curves Oil viscosity approx. 60 mm 2 /s Circulation resistance P R with valve open Q ow rate (lpm); Δp ow resistance (bar) 8/15 D 7710 NE - CNE - 09-2013-1.3 HAWE Hydraulik SE

4 Dimensions All dimensions in mm, subject to change. 4.1 Basic version (screw-in valve) CNE 2 CNE 21 CNE 23 CNE 22 1 O-ring 17.17x1.78 AU 90 Sh 2 KANTSEAL DKAR 00018-N9011 NBR 90 Sh 18.77x22.13x1.68 3 Sealing edge 4 Sealing nut 5 Valve housing 6 Threaded sealing ring HAWE Hydraulik SE D 7710 NE - CNE - 09-2013-1.3 9/15

4.2 Mounting hole Kurzanleitung Ventile Aufnahmebohrung The sealing of the inlet to outlet takes place at the contact area between the facial sealing edge of the screwed-in end of the valve body and the stepped shoulder of the core diameter at the location thread. The stepped shoulder is depicted with the normal 118 drill tip angle for steel. Therefore reaming of the hole and bevels to help the seals slip in are not necessary. The sealing of the attached valve and its xing at the manifold body are made by a sealing nut with a tting seal and an O-ring. Additionally the passage between port A and T is sealed at the screwin port and the internal piston. CNE 2 CNE 21 CNE 22 CNE 23 Note For tapped plugs for the mounting holes, see Chapter 4.4, "Tapped plugs". 10/15 D 7710 NE - CNE - 09-2013-1.3 HAWE Hydraulik SE

4.3 Version with single connection block Pipe connection a CNE 2 CNE 21 CNE 23 120 CNE 22 170 4.4 Tapped plugs The mounting holes can be sealed with tapped plugs if necessary; for example, if the assembly of standardised basic bodies is to be carried out with or without screw-in valves as required. Passage open Passage blocked 1 Tapped plug M20x1.5 DIN 910 2 Sealing ring A20x24x1.5 DIN 7603-Cu 1 O-ring 17.17X1.78 AU 90 Sh 2 KANTSEAL DKAR 00018-N9011 NBR 90 Sh 18.77x22.13x1.68 3 Tapped plug and locking tapped plug complete Type Order no. CNE 2 Z 7715 019 CNE 21 CNE 22 CNE 23 Z 7748 050 HAWE Hydraulik SE D 7710 NE - CNE - 09-2013-1.3 11/15

5 Assembly, operation and maintenance recommendations 5.1 Intended application This valve is intended exclusively for hydraulic applications ( uid engineering). The valve meets high technical safety standards and regulations for uid and electrical engineering. The user must observe the safety measures and warnings in this documentation. Essential requirements for the product to function correctly and safely: All information in this documentation must be observed. This applies in particular to all safety measures and warnings. The product must only be assembled and put into operation by quali ed personnel. The product must only be operated within the speci ed technical parameters. The technical parameters are described in detail in this documentation. The operating and maintenance manual of the speci c complete system must also always be observed. If the product can no longer be operated safely: Remove the product from operation and mark it accordingly. It is then not permitted to continue using or operating the product. 5.2 Assembly information The product must only be installed in the complete system with standard connection components that comply with market requirements (screw ttings, hoses, pipes, etc.). The hydraulic system must be shut down correctly prior to dismounting; this applies in particular to hydraulic systems with hydraulic accumulators. Danger Risk to life caused by sudden movement of the hydraulic drives when dismantled incorrectly! Risk of serious injury or death. Depressurise the hydraulic system. Perform safety measures in preparation for maintenance. 12/15 D 7710 NE - CNE - 09-2013-1.3 HAWE Hydraulik SE

5.2.1 Screwing in the screw-in valve (basic version) Screw in and locking 1. Before screwing in the valve, loosen the lock nut and sealing nut until the travel stop. 2. Screw in the valve and tighten to the speci ed torque. The metallic sealing of the inlet to the outlet is formed between the facial sealing edge of the valve and the shoulder of the stepped hole in the basic body. 3. Tighten the counter/sealing nut to the speci ed torque. 1 Stopper 2 Lock nuts and sealing nuts 3 Basic body 4 Sealing edge 5 Locking 6 Valve housing 5.2.2 Adjusting pressure Caution Risk of injury on overloading components due to incorrect pressure settings! Risk of minor injury. Always monitor the pressure gauge when setting and changing the pressure. The pressure setting can be changed by adding washers. Pressure range Pressure alteration approx. (bar) per mm CNE 2, CNE 21, CNE 23 CNE 22 Washer order no. Thickness 7748 013 a 0.5 mm A 4.2 -- B 2.5 32 C 1.7 11 7748 013 b 1.0 mm 7748 013 c 1.2 mm 7748 013 d 2.0 mm D 1.1 -- E 0.9 -- L 10.5 -- M 6.3 -- For pressure range A to M see also Chapter 2, "Available versions, main data" 5.2.3 Creating the mounting hole See description in Chapter 4.2, "Mounting hole" HAWE Hydraulik SE D 7710 NE - CNE - 09-2013-1.3 13/15

5.3 Directives Product configuration and setting the pressure and ow rate The statements and technical parameters in this documentation must be strictly observed. The instructions for the complete technical system must also always be followed. Note Read the documentation carefully before usage. The documentation must be accessible to the operating and maintenance staff at all times. Keep documentation up to date after every addition or update. Caution Risk of injury on overloading components due to incorrect pressure settings! Risk of minor injury. Always monitor the pressure gauge when setting and changing the pressure. Purity and ltering of the hydraulic uid Fine contamination can significantly impair the function of a hydraulic power pack. Contamination can cause irreparable damage. Examples of ne contamination include: Metal chips Rubber particles from hoses and seals Dirt due to assembly and maintenance Mechanical debris Chemical ageing of the hydraulic uid Note Fresh hydraulic uid from the drum does not always have the highest degree of purity. Under some circumstances the fresh hydraulic uid must be ltered before use. Pay attention to the cleanliness level of the hydraulic uid in order to maintain faultless operation. (Also see cleanliness level in Chapter 3, "Parameters".) 5.4 Maintenance information This product is largely maintenance-free. Check that the product is securely fastened in the mounting hole at regular intervals, but at least once per year. Conduct a visual inspection at regular intervals, but at least once per year, to check if the hydraulic connections are damaged. If external leakages are found, shut down and repair the system. Clean the device surface of dust deposits and dirt at regular intervals, but at least once per year. 14/15 D 7710 NE - CNE - 09-2013-1.3 HAWE Hydraulik SE

6 Other information 6.1 Schematic sectional drawing and connection example 1 To directional valve and consumer 2 Check valve, e.g. type CRK as per D 7712 3 High-pressure pressure-limiting valve, e.g. type CMV as per D 7710 MV HAWE Hydraulik SE D 7710 NE - CNE - 09-2013-1.3 15/15

Further information Additional versions Throttle valve and shut-off valve CAV: D 7711 Check valve type CRK, CRB and CRH: D 7712 Flow control valve type CSJ: D 7736 Pressure-dependent shut-off valve type CDSV: D 7876 Pressure valve type CMV, CMVZ, CSV and CSVZ: D 7710 MV Pressure-reducing valve type CDK: D 7745 Pressure-reducing valve type CLK: D 7745 L Two-stage valve type NE: D 7161 Application Connection blocks type A for hydraulic power packs: D 6905 A/1 D 7710 NE - CNE - 09-2013-1.3 HAWE Hydraulik SE Streitfeldstraße 25 81673 München Postfach 80 08 04 81608 München Germany Tel +49 89 379100-1000 Fax +49 89 379100-91000 info@hawe.de www.hawe.com