PTC Manual. Series 13B

Similar documents
TSC JR Manual SERIES 2A

BUBBLER CONTROL SYSTEM

BUBBLER CONTROL SYSTEM

Locator Locator-D-Lux Air-Saver G1 Air-Saver G2

CP3R Quick Start Manual

CPN1 Quick Start Manual

DPC-30 DPC-100. Reference Manual

COMPRESSED AIR SAVING PRODUCTS INDEX. Useful information AIR-SAVER G1 AIR-SAVER G2 LOCATOR. Condensate Management Specialist

CONTROL LOGIC DESCRIPTION DOCUMENT IC-410ND

5 Function Indicator. Outside Air Temperature (C) Outside Air Temperature (F) Pressure Altitude Density Altitude Aircraft Voltage STD TEMP SL 15000

M104 Series: Digital Manometer: 0.1 % of Full Scale

O P E R A T O R S M A N U A L

ACV-10 Automatic Control Valve

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

Table of Contents. Important Safety Information...1. Getting Started...1. Getting Started: Commands...3. Installation Instructions...

Aquacom Diving Equipment

unconventional-airsoft.com

SCF Softball Club Scoreboard Controller Operation

KELCO F60 DIGITAL PUMP CONTROLLER

OMNISPORT 2000 SWIMMING QUICK REFERENCE

SPECIFICATIONS APCEPH1

GasSense NDIR User Manual

Altimeter and Compass Watch Instruction Manual

TEL/jlRE" Introduction. Display Features and Modes. Startup Procedure. Power-Up Procedure. Adjustment Modes

A I R S W I N G E R O P E R A T O R S M A N U A L

Touch Screen Guide. OG-1500 and OG Part # T011

Pneumator. Testo Industrial Services More assurance, better service. Pressure calibrator and measuring instrument.

Owners Manual Models: 075-AQF-CX. Aquatrol Backwashing Catalytic Carbon Filter. Visit us online at.

Operating Instructions Part No

DIGITAL AUTOMATIC TYRE INFLATOR

In Response to a Planned Power Outage: PPMS EverCool II Shut Down and Re-start Procedure

AA GWR Water Retention Meter for Accurate Measurement of Water Retention

MP15 Jockey Pump Controller

CONSOLE-320 ENGLISH. 230A: CONSOLE-320 with cable data output Item 230B: CONSOLE-320 with cable + wireless radio data output

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor

TABLE OF CONTENTS INTRODUCTION 3 SAFETY PRECAUTIONS 3 PACKAGE CONTENTS 4 DEVICE OVERVIEW 4 BUTTON OPERATION SUMMARY 5 BASIC OPERATION 6

Nothing's as cool, as a freshwater pool. easychem 770 ORP and ph Controller for Pools and Spas with Timer Output for Pool Pump

MICRO BASED CONTROL SYSTEM YLCS-SA/HA/AA YAES-SA 2 System YAES-SA 3 System YAES-DSA 4 System

OC Panel High Limit Aquastat Kit, Manual Reset p/n

RAM 4021-DPX Operation Manual

KEG PUMP. Range of Electric Keg Pumps

PART 5 - OPTIONS CONTENTS 5.1 SYSTEM EXPANSION 5-3

AIR SAVING PRODUCTS ADDING VALUE AIR-SAVER LOCATOR LOCATOR-EV

AFDXXX(X)AC Series Operators Manual Please read this manual thoroughly before attempting to operate your water maker.

Manual Weighingblock VB2 series and Uniscale

Vers Gas Generator. Release III INSTRUCTION MANUAL. Advanced Calibration Designs, Inc.

SIP 1000 OPERATION AND PROGRAMMING MANUAL

GAS FUEL VALVE FORM AGV5 OM 8-03

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR

Standard Chiller 1/4 compressors Manual version: /10/96

Stand-Alone Bubble Detection System

DT 630 ALTIMETER, BAROMETER AND COMPASS WATCH OPERATING INSTRUSTIONS

VARIOspeed 3R User Manual

istart Owner s Manual

ELIMINATOR INSTRUCTIONS Table of Contents

CCT-7320/ROC-2313 Reverse Osmosis Controller

Ocean Observatories Initiative. Coastal & Global Scale Nodes. Hydrogen Safety. OOI Surface Mooring Hydrogen Safety Review

AIR-SAVER G1 AIR-SAVER G2 LOCATOR-EV COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS AIR SAVING PRODUCTS

HEAT-TIMER CORP. 20 NEW DUTCH LANE FAIRFIELD, NEW JERSEY TEL. (973) FAX (973) INSTALLATION & OPERATION MANUAL TABLE OF CONTENTS

WATER CONTROL SYSTEM QUICK START

Series 180. Commercial/Industrial Control System Installation, Operation and Maintenance Manual

INSTRUCTION MANUAL. Automatic Water Softener System. Model: PSE-08. Xsential Water Filtration Systems

MODEL 9875 STADIUM BASEBALL SCOREBOARD. Instruction Manual

BAPI Pressure Line of Products - FAQs

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

Using the UltraRAE. Firmware 2.35

AUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP

NITROGEN INFLATION SYSTEM NG-4, NG-6, NG-12, NG-18

LENNOX SLP98UHV DIAGNOSTIC CODES

HS Bubbler Technology. HyQuest Solutions New Zealand User Group August 2017

DRS4-RM Manual. Set Up Instructions for DRS4 Series Single Tank

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

Performa Cv Twin Alternating and High Flow Systems. Manual Supplement

User Manual GRI- 1500Li

CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES

User Manual. asense VAV. CO 2 / temperature sensor with built-in general purpose controller

The Univentor 1250 Anaesthesia Unit

D OPERATION and MAINTENANCE MANUAL MILITARY ALTIMASTER MA-10 (30,000 foot COMPRESSED SCALE: FP-02093) January 3, 2008 REV 12

Ocean Technology Systems ComBox

Operating instructions Electrical switching facility pco

StockWeigh 500 D3632 US-B

SRL Series. Oil-less Scroll Air Compressors. Pharmaceutical. Research & Development. Food & Beverage. Chemical. Electronic

MicroTim XB. User Manual. Precision Digital Barometric Altimeter / Barometer / VSI. Document Revision 1.0 Firmware Version 3.0

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Reverse Osmosis System Installation Guide and Operation Manual.

Technical Bulletin 112 Developed with Industry

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Temperature Controller CC24-7 ULTRA USER S MANUAL Legion Dr. Mason, MI USA October 2010 Ph. (517) Fax (517)

MOYNO FLUID DETECTION CONTROL SERVICE MANUAL. Section: ACCESSORIES. Page: 1 of 8 Date: May 1, 1998 GENERAL

Iron Filter Installation / Operation Manual

Sampling Equipment Catalog. MicroPurge Low-Flow Pump Control

Qi Litre Ultrasonic Cleaner

Autotrol Performa ProSoft

MONSOON 6V Pump Control System

User s Guide. Vacuum Controller for liquid delivery systems

DRILL MONITOR DM-100 OPERATIONS MANUAL

CPF 270, CPF 340. Instruction book

Transcription:

PTC Manual Series 13B

Electronic Design for Industry 100 Ayers Blvd Belpre, OH 45714 (740) 401 4000 www.ediplungerlift.com

DESCRIPTION The EDI Pressure Time Controller (PTC) is a combination of a pressure sensing device and a basic on/off timer. The PTC is a reliable, operator friendly controller, that allows for customization by selecting up to six options. EDI has developed a quality timer combining it with switchgauge functions and delivered it in the PTC. *Note* All characters written in Blue or Red are how the characters will appear on the LCD (Liquid Crystal Display) on the PTC controller. Characters in Blue will appear anytime the associated buttons are pressed. Characters in Red only appear when the appropirate option is turned on and the associated button is pressed. See Controller Options, page #9. FRONT PANEL CONTROLS TIME PERIOD BUTTONS: There are four time period buttons. These buttons allow the operator to display or set time period data. Their designations and functions are as follows: 1. OPEN TIME : Allows the operator to set/read the open time period. 2. SHUT TIME : Allows the operator to set/read the shut time period. 3. AFTER FLOW TIME : Allows the operator to set/read the after flow time period. The After Flow Time follows the Open Time after the plunger reaches surface. The After Flow Time allows additional open time after the plunger has reached surface. 2

4. RECOVER TIME : Allows the operator to set/read the recovery time period. The Recover Time follows the Open Time if the plunger fails to reach the surface. The Recover Time is additional shut time to allow for well recovery. Shut Time will follow Recover Time to complete the cycle. When any one of the time period buttons are pressed and held, the Up or Down buttons may be used to alter the time period to any value. If the keypad is unused for one minute, the unit will go to sleep, conserving power. Pressing any button will wake the display. When holding in on the Up and Down buttons, changing time actions will speed up. MANUAL VALVE CONTROL BUTTONS: These buttons allow the operator to manually open and shut the valve. If Option #2 reads Normal Timing, pressing the Manual Open button will also start timing a new open time cycle and pressing the Manual Shut button will start a new shut time cycle. If Option #2 reads Sequential Time, a new open/shut time cycle will be started only if the Up or Down button is simultaneously pressed with the Manual Open/Shut buttons. See Option #2 Page 9. 3

LAST 10 PLUNGER RUNS BUTTON: This button allows the operator to display the last 10 plunger travel times. Each time the button is pressed, the next plunger travel time will be displayed. The order they are displayed is as follows: #1(most current) #2 #3 #4 #5 #6 #7 #8 #9 #10, then they repeat the same order. In the following description the characters shown in Blue are what the operator will see on the LCD display; X stands for the actual digits. 1. Plunger travel time #1 (most current). Plunger Travel 1 Xd XXhr XXmn XXs 2. Plunger travel time #2 Plunger Travel 2 Xd XXhr XXmn XXs 3. Plunger travel time #3 Plunger Travel 3 Xd XXhr XXmn XXs Plunger travel times #4 through #10 read same as above. If Plunger Travel Time #1 is viewed during a plunger run, the actual timing in progress may be observed. 4

Data Button The Data button allows the operator to scroll through data each time the button is pressed. In the following description, the characters shown in Blue are what the operator will see on the LCD display. The order in which data will be displayed is as follows: 1. Plunger arrival count Plunger Arrivals 0000 2. Plunger failure count Plunger Failures 0000 3. Total Open Time Total Open Time Xd XXhr XXmn 4. Battery Voltage Battery Voltage 0.00V 5. Hi Count Hi Count 00 6. Lo Count Lo Count 00 To clear the plunger arrival count, plunger failure count, the total open time, hi count and lo count, the operator, while holding this button, can press the Up or Down buttons, and the displayed value will be cleared to zero. NOTE: Total Open Time is displayed in days, hours, and minutes. 5

OPERATIONAL DESCRIPTION for EXTERNAL INPUTS EXTERNAL INPUTS OVERRIDE PSI SET POINTS: There are three external inputs available to the operator, Open, Close, and the MSO (magnetic shut off) input. OPEN AND CLOSE INPUTS: These inputs are referred to as the Open inputs and Close inputs. These inputs may be connected between Open, Close, and Common. The inputs are labeled Open, Close, and Common. The Open input, when connected to the Common input, causes an open valve response. The Close input, when connected to the Common input, causes a close valve response. When the Open inputs are closed the valve will open and the Open Time is loaded. The Open Time will start counting when the contacts open. The operator shall be warned of an Open condition. The operator will see Open Time Hold Ext Open For and the time displayed will tell the operator how long the Open contacts have been closed. When the Open contacts open, the time will start counting. When the Close inputs are closed the valve will shut and the Shut Time will be loaded. The Shut Time will start counting when the contacts open. The operator shall be warned of a Close condition. The operator will see Close Time Hold Ext Close Input For and the time displayed will tell the operator how long the Close contacts have closed. When the Close contacts open, the time will start counting. 6

PSI Set Points Button The PSI Set Points button allows the operator to view the actual pressure input and scroll through the pnuematic set points. The different set points are as follows: Pressure 0000 (The actual input pressure. This is a read only function.) Hi Pressure Set Point 0000 Lo Pressure Set Point 0000 Valve Delay XXmn XXs Lo Shut In Set Point 00 Hi Shut In Set Point 00 When the actual pressure reaches the Hi Pressure Set Point, the Valve Delaytime starts counting down. When the Valve Delaytime times out the controller will react to the Hi Pressure Set Point, shutting and/or opening the valve. A count will be added to the Hi Count on the Data button. When the actual pressure reaches the Lo Pressure Set Point, the Valve Delaytime starts counting down. When the Valve Delaytime times out the controller will react to the Lo Pressure Set Point, shutting and/or opening the valve. A count will be added to the Lo Count on the Data button. The Valve Delaytime starts counting when a Hi or Lo Pressure Set Point is reached. The controller will not react to the Hior Lo Pressure Set Point until the Valve Delaytime times out. This avoids pressure spikes from shutting and/or opening the valve. The Lo Shut In Set Point counts the number of times the Lo Pressure Set Point is reached. When the Lo Count on the Data button matches the set point, the controller shuts the well in, placing itself in manual mode, until the operator corrects the problem. This set point only appears when Option #4 is turned on. 7

The Hi Shut In Set Point counts the number of times the Hi Pressure Set Point is reached. When the Hi Count on the Data button matches the set point, the controller shuts the well in, placing itself in manual mode, until the operator corrects the problem. This set point only appears when Option #4 is turned on. To set a desired value, scroll through the PSI Set Points button. While reading a set point or the valve delay, press the Up or Down button until the desired set point is reached. MAGNETIC SHUT OFF (MSO) INPUT: The MSO inputs are labeled + and. These inputs are designed to connect to the E.D.I. PS4 plunger sensor. Most dry contact inputs will work. 8

CONTROLLER OPTIONS: The Control Options button allows the operator to read or set up to six options. To view the current option, press this button. Each time the button is pressed, the next option will be displayed. *Note* All characters in Red and Blue are how the characters will appear on the LCD. Characters in Blue will appear anytime the associated buttons are pressed. Characters in Red only appear when the appropriate option is turned on and the associated button is pressed. Option 1 normal (factory set) IGNORE FALL TIME: Normal timing continues. Option 1 altered USE FALL TIME: Fall Time is available by pushing the Recover Time button twice. Keep the button pressed while setting the desired time. Fall Time overrides external Open inputs, allowing the plunger to reach bottom. Option 2 normal (factory set) NORMAL TIMING: Normal timing continues. Option 2 altered SEQUENTIAL TIMING: The manual shut button, MSO or Close inputs will shut the valve while timing continues through the full cycle. This keeps the controller in sequence with real time, which allows all controllers operating into the same gas line to operate in a set sequence. 9

Option 3 normal (factory set) USE PRESSURE: Turns options 4 & 5 on. Allows PSI Set Points to function as set. Option 3 altered IGNORE PRESSURE: Turns options 4 & 5 off. Ignores PSI Set Points. LCD will read: *Option #4 N/A* (N/A = Not Available) Option 4 normal (factory set) IGNORE SHUT IN Normal timing continues. Option 4 altered USE SHUT IN Activates a Lo Shut In Set Point and a Hi Shut In Set Point on the PSI Set Points button. Allows the operator to set a Lo Shut In Set Point. Each time a Lo Pressure Set Point is reached, a count is added to the Lo Count on the Data button. When the Lo Count equals the Lo Shut In Set Point, the well will be shut in and the Hold Close Timer will appear on the LCD and will tell the operator how long the well has been shut in. Allows the operator to set a Hi Shut In Set Point. Each time a Hi Pressure Set Point is reached, a count is added to the Hi Count on the Data button. When the Hi Count equals the Hi Shut In Set Point, the well will be shut in and the Hold Close Timer will appear on the LCD and will tell the operator how long the well has been shut in. Option 5 normal (factory set) HI/LO CLOSE: Turns option 6 on. Allows the Hi Pressure Set Point to open a valve and the Lo Pressure Set Point to close a valve. Option 5 altered HI OPEN/LO CLOSE: Turns option 6 off. Allows both the Hi Pressure Set Point and the Lo Pressure Set Point to close a valve. LCD will read: *Option #6 N/A* (N/A = Not Available) 10

Option 6 normal (factory set) CONTINUOUS CYCLE: Normal timing continues. Option 6 altered STOPPED CYCLE: The cycle stops timing after Shut Time, untilhi Pressure Set Point is reached, this will restart the Open Time cycle. The Manual Open button will also restart the Open Time cycle. In the STOPPED CYCLE condition, the LCD will read Hold Close Timer on the LCD and the time displayed will tell the operator how long the well has been shut in (stopped). OPTION TABLE Normal Factory Settings Altered 1 Ignore Fall Time Use Fall Time 2 Normal Timing Sequential Timing 3 Use Pressure Ignore Pressure 4 Ignore Shut In Use Shut In 5 Hi Open/Lo Close Hi/Lo Close 6 Continuous Cycle Stopped Cycle All options are factory set for normal operation. To alter an option, the operator, while holding this button, presses the Up or Down buttons and the option being viewed will be altered. *Note* Option 3 turns on Options 4 and 5. Option 5 turns on Option 6. If Option 4, 5 or 6 are not available, the options will read: *Option #4 N/A* *Option #5 N/A* *Option #6 N/A* 11

ELECTRICAL INFORMATION: POWER SUPPLY: (1) 6 volt alkaline lantern battery, Eveready #529 recommended. SOLAR PANEL: The unit may be equipped with a rechargeable 6 volt battery instead of the 6 volt lantern battery. This battery is kept fully charged by a solar panel supplied with this option. POWER CONSUMPTION: Supply voltage Current drain Power 6.5 volts maximum. 120 micro amps average. 780 micro watts average. BATTERY LIFE: The 6 volt battery should last 18 to 36 months, depending on how often the front panel controls are used. The unit shall continue to operate reliably, and shall warn the operator, in the event the battery supply fail. The LCD will read: Low Battery. TEMPERATURE RANGE: The unit is designed to operate reliably from 30 degrees Celsius to +85 degrees Celsius, 22 degrees Fahrenheit to +185 degrees Fahrenheit. Non Metallic Non Corrosive Fiberglass Reinforced Approximately 7 ½ pounds Dimensions: 8x6x4 inches SYSTEM ENCLOSURE: 12

NOTES 13

NOTES 14

Electronic Design for Industry 100 Ayers Blvd Belpre, OH 45714 (740) 401 4000 www.ediplungerlift.com