Actuating elements for ComEx

Similar documents
ComEx Actuating elements

Operating Instructions

E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1.

Operating Instructions

3G Operating instructions. Digital Purge Gas Valve 3G Type: Document no.: D0001 Version: 01. July 2011/Rev.

4/2 way Pneumatic Solenoid Valve

Further technical information is available on

Junction Boxes Series 8118

Pressure maintenance valve SDV-P / SDV-P-E

Operating Instructions

EX-RECESSED CEILING LIGHT FITTINGS

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

Declaration of Conformity as per Directive 97/23/EC

M-5071/1111. Electronic Pressure Switch PSW14 series

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

Floodlight LED. Series Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Floodlight LED. Series Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Assembly, Installation and operating. instructions for. Söll-Xenon anchorage device

Assembly instruction. Operating temperature range -60 C +85 C Protection. IP 66, 67, 68 (5 bar)

Conductor Bushings Series 8174

3 Post Pressure Fit System Owner s Manual

Suction lance SLP / SLP Operating instructions SLP Manufacturer: Keep the operating instructions for future use!

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

A17W23_MASE_MUS_EN MANUAL

Contents. Operating instructions. Pressure switch, heavy-duty version Model PSM-520

2-finger parallel gripper KTG 50

Type /2-Way Globe Valve 3/2-Wege-Geradsitzventil Vanne à siège droit 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Technical Data. Dimensions

These operating instructions apply to: PKL 190 PKL 2100 PKL 450 PKL 5000 PKL 740 PKL 10000

Operating instructions. Steuerung SILAS Control unit Type: A /...; Pressure monitor Type: 17-51P3-1604

Cable entries. Contents. Cable entries. Cable entries Introduction L.2 L.1. Standard cable glands - Plastic L.5. Standard cable glands - Brass L.

Bike holder with three-point-support for mounting stand

INSTRUCTIONS & MAINTENANCE SHEET PORTABLE HYDRAULIC PUNCHING HEAD PH045

Cable entries. Contents. Cable entries. Cable entries Introduction C.2 C.1. Standard cable glands - Plastic C.6. Standard cable glands - Brass C.

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

A18W35_MASE 130_F_EN MANUAL

Rocker valve. Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

Operating and maintenance manual Filter and reducing station Series / 1.0

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Pull-rope emergency stop switch Type HENEX and SEGEX OPERATING INSTRUCTIONS

Operating instructions Capacitive sensors KG AC (M18) / / 2010

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

A17W49_MASEM_F_EN MANUAL

Pressure Fit System - Two Post Version Owner s Manual

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Instruction Manual. Alfa Laval SB Pressure Exhaust Valve ESE02965-EN Original manual

e.do Gripper Safety requirements, technical features and assembly and integration instructions

Arran LED Floodlight Luminaire

Gas Pressure Regulator HON 300

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN Original manual

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

Pressure relief valve

IP 69 Protection against water under pressure

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Technical Data. Dimensions

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

Operating Instructions. Ball valve fitting according to ZB For pressure transmitter VEGABAR 82. Document ID: 50027

Hand lever valves VHER

Declaration of Conformity as per Directive 97/23/EC

AREA VALVE SERVICE UNITS

Two-port valves, male threaded, PN25

// ADapters GUIDelines

Prewired position switches FA series

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN

original operating manual Operating manual TankQuick 100 F2 Translation of the Item-No.:

Innovative Vacuum for Automation. Operating Instructions Dust Filter STF P / STF-D P.

Position switches FP series

OPERATING INSTRUCTIONS

Two-port seat valves

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.

Safety Please read and keep in a safe place Operating instructions Linear flow control VFC Linear flow control with actuator IFC

Magnetic level switch type MR783 Instruction Manual

Dual Pivot Caliper Brake

OPERATING INSTRUCTIONS (Translation) Rope winch Type KWE 250 KWV 300 KWE 650 KWV 650 KWE 1000 KWV 1250

Part I -Installation Tools Needed Screwdriver/Adjustable Wrench to 1-1/2 MOUNTING

Safety. Operating instructions Solenoid valve for gas VG 10/15 VG 65 DANGER. Contents WARNING CAUTION. Changes to edition 11.14

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

Pressure Switches Application Guideline

RR 16 Commercial & Industrial Regulator

Z5160 Load adapter Mounting instructions (1.2 EN)

Part I -Installation Tools Needed Screwdriver/Adjustable Wrench to 1-1/2 MOUNTING

Installation, operation & maintenance manual - original version

Pressure Reducing Valve DMV 750 set range: bar

Cost effective. Smooth. Reliable. LOG Internal Hole Gripper

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Brass Check Valve RDL

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

Limit switches OsiSense XC Special For material handling applications, type XC1 AC

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

Norrsken Family Booklet

Operating instructions - Translation of the original -

Transcription:

Description A large number of variants and versions of actuating elements are available for the ComEx control and indicator units. All actuating elements are made of high-quality thermoplastic and conform to the IP 5/IP /IP 7 type of protection. To complete the actuating elements, there are useful accessories such as e.g. label holders, marking tags, metal shroud or nut wrench. Actuating elements with NBR sealing for increased resistance to oil are available too. The actuating elements are mounted quickly and easily onto the ComEx control and indicating devices. Use in Zones 1 and 21 is certified. NOTE For actuating element dimensions, see page 3 onward. Actuating elements for ComEx Explosion protection Ex protection type II 2G Ex e II II 2D Ex td A21 IP 5, IP, or IP 7 PTB 00 ATEX 3114 U Ex e II Ex td A21 IP 5, IP, IP 7 IECEx PTB 08.0037U Class I, Div. 2, Groups A, B, C, D Class I, Zone 1, AEx e IIC, Ex e IIC UL E184198 0044 Ambient and operating temperature range -55 C to +70 C (Zone 1) - C to +70 C (Zone 21) permitted for zones Zone 1 Zone 21 (Min. requis IPX, Temperature range - C) Technical data Storage and transport temperature -55 C to +70 C Protection class See table Impact resistance 7 Nm (Lamp actuators 4 Nm) Material Enclosure thermoplastic/injection moulding Sealings EPDM, NBR for increased resis tance to oil Weight See table Fastening Installation in enclosures with wall thickness of 1 mm up to mm (threading M30 x 1.5). Suitable for through-holes 30.3 +0.3 mm Protection class of the actuating elements Description Order no. Temperature -55 C to +70 C Temperature - C to +70 C Position selector switch 05-0003-007 *** IP 54 IP, IP 7 Double pushbutton actuator 05-0003-0074 **** (*BN) 05-0003-0075 **** (*BN) IP 54 IP X Pushbutton 05-0003-000700 (*BN) IP 54 IP, IP 7 Mushroom pushbutton 05-0003-001800 (*BN) IP 54 IP, IP 7 Emergency Stop 05-0003-000800 (*BN) IP 54 IP, IP 7 Locking mushroom pushbutton 05-0003-00 (*BN) IP 54 IP, IP 7 Lock (DOM) 05-0003-0012 ** (*BN) IP 54 IP, IP 7 Lock (RONIS) 05-0003-00100 (*BN) IP 54 IP, IP 7 Position selector switch BS 2-position 05-0003-00090 ** IP 54 IP, IP 7 Position selector switch BS 3-position 05-0003-001 **** IP 54 IP, IP 7 Key switch, 2-position 05-0003-007 **** (*BN) IP 54 IP 5 Key switch, 3-position 05-0003-0079 ** (*BN) 05-0003-0080 ** (*BN) IP 54 IP 5 Position selector switch, 2-position 05-0003-0009 *** (*BN) IP 54 IP, IP 7 Position selector switch, 3-position 05-0003-001 **** (*BN) IP 54 IP, IP 7 Lamp 05-0003-001 **** (*BN) IP 54 IP, IP 7 Illuminated button actuator 05-0003-00 **** (*BN) IP 54 IP, IP 7 Potentiometer actuator 05-0003-00700 (*BN) IP 54 IP, IP 7 Blanking plug 05-0003-001900 (*BN) IP 54 IP, IP 7 *BN for increased resistance to oil (with NBR seal) BARTEC GmbH Max-Eyth-Straße 1 1/9

Safety Instructions The actuating elements may be used only within the specified ambient and operating temperature range. Utilisation in areas other than those specified and the modification of the product by anyone other than the manufacturer are not permitted and will exempt BARTEC from liability for defects and any further liability. Incorrect installation can cause malfunctioning and the loss of explosion protection. The actuating element may be connected and assembled only by qualified personnel who are authorised and trained to assemble electrical components in hazardous (potentially explosive) areas. The generally applicable statutory rules and other binding directives relating to workplace safety, accident prevention and environmental protection must be adhered to. The actuating element may be operated only if it is in a clean and undamaged condition. Marking Particularly important points in these instructions are marked with a symbol: DANGER Non-observance leads to death or serious physical injury. The necessary safety measures must be taken. CAUTION Warning of damage to property and financial and penal disadvantages (e.g. loss of guarantee rights, liability etc.). ATTENTION Important instructions and information on preventing disadvantageous behaviour. NOTE Important instructions and information on effective, economical and environmentally compatible handling. Assembly and Commissioning NOTE The description of the assembly of the actuating elements starts on page 8. Assembly/disassembly ATTENTION Only authorised and qualified personnel may do any of the assembly, disassembly, installation and commissioning work. The minimum centre-to-centre spacing between two mounting holes must be observed. Make sure the actuating element being fitted is intact (no cracks). Installation Only suitable tools may be used for installation work. It is not permissible to modify the actuating element in any way. Commissioning Before commissioning check that: the device has been installed correctly the device is not damaged Operation, Maintenance and Fault Clearance The operator of the actuating element must keep it in good condition, operate it properly, monitor it and clean it regularly. Actuating elements, seals, glands must be checked regularly for cracks and damage. NOTE Dirty actuating elements can be cleaned with compressed air. The actuating element is defective if it no longer actuates the attached command equipment or if the illuminated disc becomes damaged or dull. Defective actuating elements cannot be repaired; they must be replaced. Defective actuating elements can be taken off and replaced by functioning actuators of the same type. Accessories, spare parts see BARTEC catalogue Disposal The components in the actuating element contain metal and plastic parts. The statutory requirements for disposing of electronic scrap must be observed therefore (e.g. disposal by an approved disposal company). Service address BARTEC GmbH Max-Eyth-Straße 1 Standards conformed to EN 0079-0: 0 EN 0079-7: 07 EN 1241-0: 0 EN 1241-1: 04 IEC 0079-0: 04 IEC 0079-7: 0-07 IEC 1241-0: 04 IEC 1241-1: 04 BARTEC GmbH Max-Eyth-Straße 1 2/9

Selection chart for ComEx enclosures 34 2 Position selector switch black, with 2 or 3 switching positions, with protective shroud, lockable*, only for switch modules (2-pole) 0 - I for control units (flat): 05-0003-007001 for ComEx enclosures: 05-0003-007101 Ø 5 I - II for control units (flat): 05-0003-007002 for ComEx enclosures: 05-0003-007102 for control units/comex 31L 34 2 I - 0 II for control units (flat): 05-0003-0073 for ComEx enclosures: 05-0003-007303 HAND - 0 - AUTO for control units (flat): 05-0003-007224 for ComEx enclosures: 05-0003-007324 Ø 5 MAN - 0 - AUTO for control units (flat): 05-0003-007225 for ComEx enclosures: 05-0003-007325 Weight: 74 g 3 boreholes at the protective shroud for fitting padlocks in switching position 0 (I) or to customer's specifications. for ComEx enclosures 39 Double pushbutton actuator with EPDM rubber membrane or with NBR sealing, 5 labels red, green, yellow, white, black, supplied loose for ComEx enclosures with EPDM sealing: 05-0003-007500 for ComEx enclosures 05-0003-007500BN 75 for control units with EPDM sealing: 05-0003-007400 for control units 05-0003-007400BN Weight: 52 g for control units/comex 31L 39 75 Pushbutton with EPDM rubber membrane or with NBR sealing, 5 labels red, green, yellow, white, black, supplied loose with EPDM sealing: 05-0003-007000 05-0003-007000BN Weight: 24 g BARTEC GmbH Max-Eyth-Straße 1 3/9

38 Mushroom pushbutton with EPDM rubber membrane or with NBR sealing, black Ø 40 with EPDM sealing: 05-0003-001800 05-0003-001800BN Weight: 24 g 38 EMERGENCY STOP slam button with EPDM rubber membrane or with NBR sealing, pushbutton marked "NOT-AUS EMERGENCY STOP - Pull to Release" Ø 40 N EM E O R G E T N C A S Y U S T P O DIN EN 04-1: 07 DIN EN 0947-5-1: 05 (VDE 00 Part 0) with EPDM sealing: 05-0003-000800 05-0003-000800BN Weight: 4 g 2 Locking mushroom pushbutton, push in without key, unlock with key DOM lock 4 A 185 with EPDM sealing: 05-0003-00 05-0003-00BN Weight: 70 g 2 Lock DOM lock 4 A 185 Lockable in both positions, Key retractable in both positions: with EPDM sealing: 05-0003-0010 05-0003-0010BN 5 Lockable in the depressed position, Key retractable in the depressed position: with EPDM sealing: 05-0003-0011 05-0003-0011BN Tip lock lockable in the initial positions, Key retractable in the initial positions: with EPDM sealing: 05-0003-0012 05-0003-0012BN Weight: 9 g 31 5 Lock RONIS lock 455 Lockable in both positions, Key retractable in both positions with EPDM sealing: 05-0003-00100 05-0003-00100BN Weight: 75 g BARTEC GmbH Max-Eyth-Straße 1 4/9

2 switching positions 30 90 Position selector switch BS, black, with 2 or 3 switching positions, Ø 45 0 - I for control units: 05-0003-000900BS for ComEx enclosures: 05-0003-000901BS I - 0 - II (I + II latching) for control units: 05-0003-001000BS for ComEx enclosures: 05-0003-001100BS 3 switching positions 30 0 0 I - 0 - II (I + II momentary contact) for control units: 05-0003-001001BS for ComEx enclosures: 05-0003-001101BS I - 0 - II (I latching, II momentary) for control units: 05-0003-001002BS for ComEx enclosures: 05-0003-001102BS Ø 45 I - 0 - II (I momentary, II latching) for control units: 05-0003-001003BS for ComEx enclosures: 05-0003-001103BS Weight: 33 g 2 switching positions 3 3 switching positions Key-operated switch, RONIS lock 45, with 2 or 3 switching positions, 0 - I latching, key retractable for control units: 05-0003-007700 for ComEx enclosures: 05-0003-007800 0 - I momentary contact, for control units: 05-0003-007701 Position I key not retractable for ComEx enclosures: 05-0003-007801 I - 0 - II (I + II latching), for control units: 05-0003-007900 Key retractable for ComEx enclosures: 05-0003-008000 3 Weight: 49 g BARTEC GmbH Max-Eyth-Straße 1 5/9

2 switching positions Position selector switch, black, with 2 or 3 switching positions 28 90 0 I 0 - I for control units with EPDM sealing: 05-0003-000900 05-0003-000900BN with EPDM sealing: 05-0003-000901 05-0003-000901BN 3 switching positions 28 0 I 0 II 0 I - 0 - II for control units (I + II latching) with EPDM sealing: 05-0003-001000 05-0003-001000BN with EPDM sealing: 05-0003-001100 05-0003-001100BN I - 0 - II for control units (I + II momentary) with EPDM sealing: 05-0003-001001 with NBR sealing 05-0003-001001BN with EPDM sealing: 05-0003-001101 05-0003-001101BN I - 0 - II for control units (I latching, with EPDM sealing: 05-0003-001002 II momentary contact) with NBR sealing 05-0003-001002BN with EPDM sealing: 05-0003-001102 05-0003-001102BN I - 0 - II for control units (I momentary contact, with EPDM sealing: 05-0003-001003 II latching) with NBR sealing 05-0003-001003BN with EPDM sealing: 05-0003-001103 05-0003-001103BN Weight: 33 g 22 Lamp module actuator red with EPDM sealing: 05-0003-0000 red 05-0003-0000BN green with EPDM sealing: 05-0003-001400 green 05-0003-001400BN yellow with EPDM sealing: 05-0003-001500 yellow 05-0003-001500BN white with EPDM sealing: 05-0003-00100 white 05-0003-00100BN blue with EPDM sealing: 05-0003-001700 blue 05-0003-001700BN Weight: 19 g BARTEC GmbH Max-Eyth-Straße 1 /9

14,5 Illuminated button actuator red with EPDM sealing: 05-0003-00500 red 05-0003-00500BN green with EPDM sealing: 05-0003-0000 green 05-0003-0000BN yellow with EPDM sealing: 05-0003-00700 yellow 05-0003-00700BN white with EPDM sealing: 05-0003-00800 white 05-0003-00800BN blue with EPDM sealing: 05-0003-00900 blue 05-0003-00900BN Weight: 19 g 2 Potentiometer actuator, black, durable and abrasion-resistant Scale gradation from 0 to 10 with EPDM sealing: 05-0003-00700 05-0003-00700BN Weight: 28 g 17 Blanking plug, to cover unused holes in the cover with EPDM sealing: 05-0003-001900 05-0003-001900BN Weight: g 05-0003-7D0001-A.01-BARTECWerbeagentur-301744E BARTEC GmbH Max-Eyth-Straße 1 7/9

Assembly drawing 1 - mm 2,8-3,4 Nm 1 2 3 4 1 Example of an actuating element 3 Fixing nut Article number 05-18-0009 2 Optional accessories (e.g. label holders Article number 05-0044-0001 for an additional inscription) 4 Nut wrench Article number 05-1191-0001 click 1 2 1 Illuminated button actuator Article numbers 05-0003-00500, -0000, -00700, -00800 or -00900 2 Illuminated button Article number 07-333-3 Mounting hole for size dia. 30.3mm with cut-out for anti-twist protection, typical position: top (12 o clock position). Minimum spacing for the mounting boreholes: horizontal 40 mm, vertical 70 mm * - recommended spacing for mushroom pushbutton and slam button 100mm - required spacing for position selector switches with protective shroud min. 0 mm BARTEC GmbH Max-Eyth-Straße 1 8/9

Operating Instructions BARTEC GmbH Max-Eyth-Straße 1 9/9