Technical Bulletin, Communicating with Gas Chromatographs

Similar documents
Technical Bulletin, Meter Factor Linearization

HART Communications Board

Bernhard Thomas September EnCal 3000 prochain Energy in Gas with ROI

VERIFYING GAS CHROMATOGRAPH OPERATION AT CUSTODY TRANSFER LOCATIONS Murray Fraser Daniel Measurement & Control

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

Mr Roger Wood Measurement & Process Group (M&P) Network Strategy National Grid Gas plc Brick Kiln Street Hinckley Leicestershire LE10 0NA

EnCal 3000 Gas Chromatograph Commissioning and Maintenance Manual Biogas and THT-Devices

Using Modbus Protocol with the ALTUS Net Oil Computer. Instruction Manual

Built-in Purge Control Functions

Three Columns Gas Chromatograph Analysis Using Correlation between Component's Molecular Weight and Its Response Factor

SHIMADZU LC-10/20 PUMP

Remote. Measurement Assurance. Why CEESmaRT? significantly in measurement

PRODUCT MANUAL. Diver-MOD

Supersedes: The copy of this document located on Measurement Canada s website is considered to be the controlled copy.

Instruction Manual. BZ7002 Calibration Software BE

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

ProSoft Technology, Inc. Summary Regarding Alberta Energy and Utilities Board Directive 017 of May 2007

HumiSys HF High Flow RH Generator

Micro Motion 3098 Gas Specific Gravity Meter

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

Operating Instructions

Improved Reliability in Natural Gas Energy Measurement with the Revised ISO Standard. Gerard Nieuwenkamp - VSL

BUBBLER CONTROL SYSTEM

Operating Manual. SUPREMA Calibration. Software for Fire and Gas Warning Units. Order No.: /01. MSAsafety.com

CONTROL UNIT GC 9000 VC

Fixed Ozone Monitor User Manual December, Automatikprodukter

Domino DUEMMEGI. Domino. Communication Interface DFTS User s Manual. Release September 2007

Electronic Volume Correctors

Electrical Solutions Corporation 2368 Eastman Ave, Suite 13, Ventura, CA Phone (805) ~ Fax (805)

Gas Measurement Fundamentals Certification. Curriculum

Overview. Front Panel: Keypad and Display

DeeterFlow Automatic Liquid Dispenser

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual

Series 7250 Ruska High-Speed Digital Pressure Controller. GE Sensing. Features

Injection Controller Program User Manual (for FloBoss 107 and ROC800-Series)

SIDRA INTERSECTION 6.1 UPDATE HISTORY

ISO INTERNATIONAL STANDARD

CNC Communication Protocol

Quantitative Analysis of Hydrocarbons by Gas Chromatography

Automatic Isokinetic Sampler. ST5 Evo

4000 series (includes 4100, 4200 & 4900)

FUNDAMENTALS OF GAS CHROMATOGRAPHY, GAS QUALITY & TROUBLESHOOTING Larry Ewing Chandler Engineering Company LLC

SDI mA Pressure Transducer (Submersible + Dry) Model WL2100 Operating Manual

Title: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator

Title: Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

UNDERSTANDING, ACCELERATED

General Specifications

BUBBLER CONTROL SYSTEM

Special Documentation Proline Promass 300 Modbus RS485. Petroleum Application Package MANUAL

Special Documentation Proline Promass 500 Coriolis Flowmeter Modbus RS485 Petroleum Application Package

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

KEM Scientific, Inc. Instruments for Science from Scientists

[CROSS COUNTRY SCORING]

Quickstart Installation Checklist (Please refer to operation manual for complete installation instructions)

FTC130 Transmitter. Operating Manual

General Specifications

955730_1 4/17/18. FlowSense Operator s Guide For Gen2 20/20 SeedSense Displays

USER MANUAL. Intelligent Diagnostic Controller IDC24-A IDC24-AF IDC24-AFL IDC24-F IDP24-A * IDP24-AF * IDP24-AFL * IDP24-F * 1/73

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

ONSITE PROVING OF GAS TURBINE METERS Daniel J. Rudroff Invensys Metering Systems

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

PART 5 - OPTIONS CONTENTS 5.1 SYSTEM EXPANSION 5-3

PGA3510 Portable 3-Gas IR Analyzer. Operations Manual

HOT SPOT MONITOR (HSM)

Continuous Gas Analysis In situ laser gas analyzers TÜV and MCERTS add-on for LDS 6 operating instructions Compact Operating Instructions

General Specifications

A Depletion Compensated Wet Bath Simulator For Calibrating Evidential Breath Alcohol Analyzers

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

SAUTER flexotron 800 heating. List of network variables for Modbus communication. Manual P A P

Design Envelope Booster. Sequence of operation

Research and Development. Money in the Pipeline

Thermo Scientific Model 146i Principle of Operation

Mass Flowmeters. Mass Flowmeters for Gases

Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

Atlas 6TM. Indoor Air Quality Monitor Instruction Manual. Measures CO 2, Temperature and Humidity DISTRIBUTED BY

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

Rotel RX-1052 RS232 HEX Protocol

Calibration of a GC955

Doc. no.dit om005 PRODUCT NAME. IO-Link/ELECTRO-PNEUMATIC REGULATOR. MODEL / Series / Product Number ITV*0*0-IO****-X395

[CROSS COUNTRY SCORING]

ACV-10 Automatic Control Valve

Hydro-Control V User Guide

AX5000 Operational Manual

Flare Gas Composition Analysis and QA/QC Lessons Learned and Lessons Lost SPECTRUM ENVIRONMENTAL SOLUTIONS, LLC 1

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Retention Time Locking: Concepts and Applications. Application

Automated Determination of Dissolved Gases in Water Anne Jurek. Abstract: Discussion:

Pneumatic high-pressure controller Model CPC7000

Automated Mass Handling for High Performance Pressure Balances

Special Documentation Proline Promass 80, 83

Gases&Technology. Measurement of Impurities in Helium Using the Dielectric Barrier Discharge Helium Ionization Detector. FEATURE.

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

AN-140. Protege WX SALLIS Integration Application Note

INSTRUCTION MANUAL DRY PRESSURE TRANSDUCER MODELS WL3100/WL3100A

Digi Connect ME 9210 Linux: serial port 2 for JTAG modules

MP15 Jockey Pump Controller

Pneumatic high-pressure controller Model CPC7000

Safety Manual. Process pressure transmitter IPT-1* 4 20 ma/hart. Process pressure transmitter IPT-1*

SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel. DTLS Manual

Transcription:

Last Updated: 13- July-2010 TB-080000C Technical Bulletin, Communicating with Gas Chromatographs OMNI FLOW COMPUTERS, INC. 12620 West Airport Boulevard, Suite 100 Sugar Land, Texas 77478 United States of America Phone-281.240.6161 Fax: 281.240.6162 www.omniflow.com 52-0001-0008/Rev C Page 1 of 7

NOTE: User Manual Reference This Technical Bulletin complements the information contained in the User Manual, applicable to Revision 23.74/27.74+. Table of Contents Scope...3 Abstract...3 GC to OMNI Flow Computer Communications...3 Serial Port #3...4 Step 1) Check GC to see if new analysis is available...4 Step 2) Get Component Stream and current GC date and time...4 Step 3) Get Component Mole % s...4 Step 4) Get BTU Dry, BTU Saturated at Base, BTU Wet and Total un-normalized Mole %..4 Step 5) Determine how to handle C6+ and ratio into C6, C7, and C8 according to code #...5 Normalized GC Composition...5 C9+ Component...5 Model 2251 Chromatograph Controller. US Versions and ISO Version...6 52-0001-0008/Rev C Page 2 of 7

Scope This Technical Bulletin applies to application firmware revisions 23.74+ and 27.74+ of OMNI 6000/OMNI 3000 Flow Computers, for gas flow metering systems which can apply a Gas Chromatograph. The OMNI Flow Computer can communicate via serial on Port #3 with any Gas Chromatograph such as the Danalyzer SIM 2251, ABB NGC8206 or any other GC which can emulate the Danalyzer process. When communicating to a Danalyzer, or ABB NGC8206, Modbus ASCII or RTU is used. Current firmware applications 23 and 27 provide the option to add a second Gas Chromatograph, in multi drop mode via serial Port #3. Additional override codes for Gas Chromatograph 2 are listed in OmniCom. Users should note that when using overrides codes with Gas Chromatograph 2 it is mandated that Gas Chromatograph 1, and Gas Chromatograph 2 have identical stream configurations. Applied Automation GC, which uses the AA proprietary HCI-A protocol interface, can also be used but the user must select the Applied Automation GC in the Analyzer setup menu. Abstract The Gas Chromatograph provides a compositional analysis of the gas exported through the Gas Metering Skid. It is supplied with a representative sample of the gas via a pressure letdown system, which reduces the pressure from line conditions to analyzer conditions. A typical process Gas Chromatograph is fitted with three (3) columns. These are very small-bore tubes of differing lengths packed with molecular separation material known as the stationary phase and a series of switching values to divert the flow via various column combinations. This equipment is housed in an oven which is temperature controlled. A constant flow of carrier gas is routed through the columns and values at a typical flow. This is used to flush the columns and transport the sample through the columns. Prior to a start up the chromatograph is calibrated using a sample cylinder filled with a gas mixture representative of the range of gas components found in the gas line. It is very important that the test gas mix is selected as close as possible to that of the line gas, as the instrument response is not linear. EG if our line gas has a 68% methane content, but our test gas has a 74% methane value significant errors may be introduced. This is particularly important for the heavier gas components. GC to OMNI Flow Computer Communications Action steps below refer to the OMNI Flow Computer accessing the Danalyzer GC database. To be compatible, the GC must have data points at all of these addresses. Many data points are collected for info only and would not be missed (could contain zeroes), but some are critical and must be present (a list is provided at the end of this Technical Bulletin). The OMNI Flow Computer Rev 23/27 application, Serial Port #3 should be set to the following per Danalyzer GC recommendations: 52-0001-0008/Rev C Page 3 of 7

Serial Port #3 Baud Rate 9600, Stop Bits 1, Data Bits 7, Parity Even, Xmit Key Delay 0, Protocol type 5 (Danalyzer ASCII), CRC enabled Y The GC would be set as follows: Port usage = SIM_2251, Baud Rate = 9600, Data Bits = 7, Stop Bits = 1, Parity= Even, Handshake = None, RTS On = 0, RTS Off = 0, PRTCL = ASCII, Comm ID = 1, RW = RW Wiring examples are as follows (assumes GC Com3 is configured for RS-485 or GC COM1 is configured for RS-232) (RS-485 2-wire) OMNI 6000 TB4 pin 1 to Danalyzer GC J10 (Com3) pin 2 OMNI 6000 TB4 pin 4 to Danalyzer GC J10 (Com3) pin 5 OMNI 6000 TB4 pin 5 to Danalyzer GC J10 (Com3) pin 3 (RS-232) OMNI 6000 TB4 pin 1 to Danalyzer GC J5 (Com1) pin 3 OMNI 6000 TB4 pin 3 to Danalyzer GC J5 (Com1) pin 2 OMNI 6000 TB4 pin 4 to Danalyzer GC J5 (Com1) pin 5 Step 1 Check GC to see if new analysis is available Read Modbus point 3041 through 3059 (19 registers). Check 3045 (GC Cycle Start Time Minutes) if this has changed go to step (2) otherwise wait for Results Interval Timer to time-out (adjustable in minute increments, but usually set to 1 min) and repeat step (1). Step 2 Get Component Stream and current GC date and time Attempt to read Modbus point 3034 through 3040 (7 registers). If the GC provides a good response, go to step (3), or else go to step (1). Step 3 Get Component Mole % s Attempt to read Modbus points 7001 through 7024 (24 32-bit IEEE floats in normal OMNI format). If it is a good response go to step (4), else go to step (1). Note that the OMNI reads more than the 16 Mole % s that are available in the Danalyzer. This is done for compatibility with Houston Atlas GC which has more components available but otherwise emulates a Danalyzer. Step 4 Get BTU Dry, BTU Saturated at Base, BTU Wet and Total un-normalized Mole % NOTE: GC Heating Value On Application 27.75, user is allowed to select either the actual BTU 7054 or Dry Superior 7033 in their calculation. Currently, the default is Dry Superior when actual BTU is set to 0.0. Attempt to read Modbus points 7033 through 7054 (22 32-bit IEEE floats). If good response go to step (5), or else go to step (1). Point 7054 (actual BTU) usually is the same as point 7033 (dry BTU), but can be manipulated within the GC to include an estimated H2O effect. The OMNI uses point 7054 as the actual BTU for internal use. Point 7038 (un-normalized Total Mole %) is compared to 100%. If the deviation exceeds a user-entered value, the GC will be logged as having failed and fixed values will be used for the analysis. While the SG and BTU data in the GC is normally not component data, the flow computer still needs a number to be entered for each entry. Simply assign the next two sequential numbers after all the other components have been entered. 52-0001-0008/Rev C Page 4 of 7

Step 5 Determine how to handle C6+ and ratio into C6, C7, and C8 according to code # Attempt to read register 3001 (1 register). If a bad response, go to step (1), else determine if the contents of 7001 relate to C6+ by checking the value of 3001: If 3001 = 108 or 08 7001 = C6+ Ratio.47466 /.3534 /.17194 If 3001 = 109 or 09 7001 = C6+ Ratio.50 /.50 / 0.0 If 3001 = 110 or 10 7001 = C6+ Ratio.50 /.25 /.25 If 3001 = 111 or 11 7001 = C6+ Ratio.57143 /.28572 /.14285 If 3001 is none of these codes, 7001 is considered not to contain C6+ and will be allocated as specified in the OMNI Analyzer Setup menu. This menu is where the user specifies what components are contained in what fields. NOTE: Beginning with revisions 23.74 and 27.74 of OMNI firmware, you specify the breakdown ratios of the C6 through C10 components in the OMNI configuration therefore the OMNI no longer reads GC register 3001. List of critical data points used by the OMNI. Each of these points are embedded within one of the blocks of data described above. 3001 Code # defining the contents of floating point register 7001. OMNI checks for C6+. 3034 Specifies what stream # this analysis pertains to. OMNI checks this. 3045 Cycle start time minutes. When this changes, OMNI assumes new analysis. 3059 Cal / Analysis Flag. If 0 indicates that analysis is a calibration run and should be ignored. 3046 Contains Alarm Flags. See GC Manual. MSB 15 (checksum failure) and Bit 14 (analyzer failure) ON will fail the GC. 3047 Contains Alarm Flags. See GC Manual. Bits 3 (adjust preamp) and 2 (preamp failure) ON will fail the GC. 7001 7024 Can contain up to 24 component mole % s. C6+ if present, is usually located in 7001. 7035 Contains Relative Density (SG) 7038 Contains Total Un-Normalized mole % s. 7054 Contains Actual BTU Normalized GC Composition GC components should be normalized when received by the flow computer. If using AGA5 or GPA2172 heating value no additional normalization is performed. Selecting ISO6976 and using Revision 23/27.74.30 and higher, will provide normalization. C9+ Component GC with C9+ component should enter this component under the n-nonane using the next number in sequence for the component order from the GC. 52-0001-0008/Rev C Page 5 of 7

Model 2251 Chromatograph Controller. US Versions and ISO Version The main difference between the USA and ISO versions of the Model 2251 is the following: US Version ISO Version Index Description Index Description 7033 BTU Dry 7033 HSUP Dry 7034 BTU Saturated 7034 HSUP Saturated 7035 Specific Gravity 7035 Relative Density 7036 Compressibility 7036 Compressibility 7037 WOBBE Index 7037 WOBBE Index 7038 Total Unnormalized Mole % 7038 Total Unnormalized Mole % 7039 Total GPM 7039 N/A See Note: below 7040 Ratio #1 7041 Ratio #2 7042 Ratio #3 7043 Ratio #4 7044 Ratio #5 NOTE: GPM is available on US versions of the Models 2251 and 2255 only. ISO versions of the controller will contain weight % only. Additional information can be found on the www.emersonprocess.com web site. 52-0001-0008/Rev C Page 6 of 7

DOCUMENT REVISION HISTORY DOCUMENT INITIAL RELEASE DATE...03-May2008 REVISION DATE PURPOSE / CHANGE REQUEST A 03-May-2008 Maintained on the Web - Initial release B 09-April-2009 DCR 090099 C 13-July-2010 DCR 100120 52-0001-0008/Rev C Page 7 of 7