RECOMBINATE. [Antihemophilic Factor (Recombinant)] (For intravenous use only)

Similar documents
PREPARATION AND SELF-ADMINISTRATION INSTRUCTIONS FOR PATIENTS

PREPARATION AND SELF-ADMINISTRATION INSTRUCTIONS FOR PATIENTS

TEV-TROPIN [somatropin (rdna origin) for injection] 5 mg & 10 mg

RECONSTITUTION AND ADMINISTRATION INSTRUCTIONS FOR HEALTHCARE PROFESSIONALS

RECONSTITUTION AND ADMINISTRATION INSTRUCTIONS FOR HEALTHCARE PROFESSIONALS. Hereditary Angioedema

Aseptic Techniques. Techniques for Sterile Compounding. Pharmacy Technician Training Systems Passassured, LLC

Patients Guide for Self Administering Intravenous Antibiotics General points

Note: Does have indication for Prophy- suggest 25 units/kg every other day

helping patients thrive Clotting Factor Concentrate Information

Varithena Delivery System Instructions for Use INSTRUCTIONS FOR USE Please read the Product Monograph before using the product.

Varithena Delivery System Instructions for Use

Dilution Sequence Protocol

PERFORMANCE OF A FINGERSTICK

Mixing Methacholine Dilutions for Bronchoprovocation Challenge Testing

STANDARD OPERATING PROCEDURE ADVANCED INTRAVENOUS TRAINING ARM (S )

Dilution Sequence Protocol

Dilution Sequence Protocol

CSL Behring PACKAGE LEAFLET: INFORMATION FOR THE USER

Before you start sampling, be sure to read

3. This solution retains potency for 2 8 hours at room temperature after reconstitution.

Articulating Legs with Intraosseous Infusion Simulator LF03840U Instruction Manual

Venepuncture. Clinical Skills. Venepuncture. Dr Brian Jenkins (Clinical Skills Lead) Sian Williams (Clinical Skills Manager)

COLLECTION OF BLOOD. Types of patients

PIMA MEDICAL INSTITUTE RADIOGRAPHY PROGRAM ARRT GENERAL PATIENT CARE COMPETENCIES CPR

STANDARD OPERATING PROCEDURE

Peripheral Venous Catheter Placement Simulator

General Safety Rules

A designated area will have been assigned for all blood specimens to be taken. All blood should then be taken in that area only.

Before you use KINERET. When you must not use it. Do not use KINERET if you have. using a medicine known as tumour necrosis factor (TNF) antagonist.

Before you use. When you must not use it

Chapter 40. Fluid, Electrolyte, and Acid Base Balance. Procedures Checklist INTRAVENOUS THERAPY. Procedure 40.1: Starting an Intravenous Infusion

Bt-Cry1Ac & Bt-Cry2A Multi-trait ELISA Kit DAS ELISA for the detection of Bt-Cry1Ac & Bt-Cry2A proteins Catalog number: PSM 14900

Monosed ESR Non-Vacuum Tube USER S MANUAL

Basic Flows in a Microfluidic Device

Patient Guide. Baxter Elastomeric Devices. Promoting patient-centric care

Parts identification:

Blue Thumb Test Procedures

Venous Blood Collection Passport

PEDIATRIC INJECTABLE TRAINING ARM SIMULATOR LF00958U INSTRUCTION MANUAL

IVIG Educational Presentation

HemoCue Hb Procedure Template

Fast or Slow? BROWARD COUNTY ELEMENTARY SCIENCE BENCHMARK PLAN. SC.C The student understands that different things move at different speeds.

Standard. Bag & Stand Advanced Venepuncture Arm. Light. Part No: Brown. Part No: Black. Part No: 00442

Venepuncture. Clinical Skills. Venepuncture. Next

Module IV Administration of Medications and Treatments Handouts

INJECTING GUIDE By Pat Magee

TJF-Q180V Cleaning and Disinfection Checklist

VENIPUNCTURE MODULE 5: THE VENIPUNCTURE PROCEDURE

EMERGENCY EQUIPMENT TROLLEY DAILY SIGNATURE SHEET. Please refer to the Emergency Equipment stock poster for detailed information

CspB ELISA Kit DAS ELISA for the detection of CspB protein Catalog number: PSP 35500

Aseptic processing. the starting material to the finished product, should be controlled by Validation Control of the aseptic process

PREPARING GAS SAMPLES IN LARGE PLASTIC SYRINGES

Bt-Cry2Ab and Bt-Cry3Bb1 Multi-trait ELISA Kit DAS ELISA for the detection of Bt-Cry2Ab and Bt-Cry3Bb1 proteins Catalog number: PSM 26800

Standard. Standard. Venepuncture Arm. Light. Part No: Brown. Part No: Black. Part No: 00332

Clinician Guide. Baxter Elastomeric Devices. Promoting patient-centric care

PREPARATION AND PROPERTIES OF ATMOSPHERIC GASES I: Carbon Dioxide and Oxygen

C O L O G Y. New. g u O N. l o t a C a. The high security connection

TJF-Q180V Cleaning and Disinfection Checklist

CVC Insertion Simulator

Veterinary Science Handling and Restraining Practicum. Restraint of the Cat for Cephalic IV Catheter Placement

Grow to Pro Basketball

Laboratory #2 Pipetting Technique and Micropipette Calibration Skills=40 pts

Newborn Nursing Skills and ALS Simulator LF01400U Instruction Manual

3 Way Taps. Year Group: BVSc4 + Document number: CSL_A11

CCM Approval: IACUC Approval:

EASYPUMP II THE FLEXIBLE SOLUTION FOR SHORT AND LONG TERM INFUSION THERAPIES

AR251/AR251-B. Venepuncture and Infusion Arm. Instruction Manual

Skills & Scenarios 81

Understanding Tracheostomy Care

Infant IV Leg LF03636U Instruction Manual

Child CRiSis Injectable Training Arm LF03612U Instruction Manual

SodaStream is the modern way to enjoy delicious bubbles. without the bottles. No more lugging or storing heavy

Standard Operating Procedures for Biological Sample Collection and Storage (IMAGEN-FU3)

Skills & Scenarios 81

Advanced IV Hand LF01139U & LF01146U Instruction Manual

Experiment 18 Properties of Gases

HEALTH SERVICES CODE A.6 CATEGORY: RN - SNP

FMEA What s the Worst That Could Happen?

TECHNICAL BULLETIN. TriControls. Control Materials for Liquid QC and Calibration Verification

LABORATORY TECHNIQUES. Pouring Liquids

CHILD CRiSis INJECTABLE TRAINING ARM LF03612U INSTRUCTION MANUAL

Adult Sternal Intraosseous Infusion Simulator LF04200U Instruction Manual

CONFER ABOVE GROUND CURVE STEP / ABOVE GROUND CURVE STEP SYSTEM ASSEMBLY AND INSTALLATION MANUAL

CHAPTER 10 Reconstitution of Powdered Drugs

NOTES PATIENT DETAILS

Read this first. Zetasizer nano series Self installation and Quick start guide MRK825-02


OVERHEAD CONDUCTOR CLEANING

Specimen Collection. Lead Screen Filter Paper Testing Dried Blood Spots (DBS) Laboratory Services February 2017

1.0 PURPOSE The purpose of this procedure is to describe the use of basic aseptic technique.

Elcometer 138. Bresle Kit and Patches. Operating Instructions

Katy Independent School District Science Safety Rules

Part II. Under Construction Station Instructions. Lab Station A - Blue Print: There is O 2 Here!

PARTICLE SPACING PART 1

Nursing Guide Portsystems

Part A: 20 minutes plus 30 minutes setting time Part B: day 1, 20 minutes; then 5 minutes each day for about 5 days

How to place the EQUIVET Ocular Lavage Kit

FIRST AID. Toolbox Talk

Ultrasound Compatible Lumbar Puncture/ Epidural Simulator

Elcometer 138. Bresle Kit and Patches. Operating Instructions

Transcription:

Website for more information: http://www.recombinate.com/ INSTRUCTIONS FOR USE RECOMBINATE [Antihemophilic Factor (Recombinant)] (For intravenous use only) Do not attempt to do an infusion to yourself unless you have been taught how by your doctor or hemophilia center. 1. In a quiet place, prepare a clean flat surface and gather all the materials you will need for the infusion. Check the expiration date, and let the vial with the RECOMBINATE concentrate and the Sterile Water for Injection, USP (diluent) warm up to room temperature. Wash your hands and put on clean exam gloves. If infusing yourself at home, the use of gloves is optional. 2. Remove caps from the RECOMBINATE concentrate and diluent vials to expose the centers of the rubber stoppers.

3. Disinfect the stoppers with an alcohol swab (or other suitable solution suggested by your doctor or hemophilia center) by rubbing the stoppers firmly for several seconds, and allow to dry prior to use. Place the vials on a flat surface. 4. Open the BAXJECT II device package by peeling away the lid, without touching the inside of the package. Do not remove the BAXJECT II device from the package. 5. Turn the package with the BAXJECT II device upside down, and place it over the top of the diluent vial. Fully insert the clear plastic spike of the device into the center of the diluent vial s stopper by pushing straight down. Grip the package at its edge and lift it off the device. Be careful not to touch the white plastic spike. Do not remove the blue cap from the BAXJECT II device. The diluent vial now has the BAXJECT II device connected to it and is ready to be connected to the RECOMBINATE vial.

6. To connect the diluent vial to the RECOMBINATE vial, turn the diluent vial over and place it on top of the vial containing RECOMBINATE concentrate. Fully insert the white plastic spike into the RECOMBINATE vial s stopper by pushing straight down. Diluent will flow into the RECOMBINATE vial. This should be done right away to keep the liquid free of germs. 7. Swirl the connected vials gently and continuously until the RECOMBINATE is completely dissolved. Do not shake. The RECOMBINATE solution should be colorless to light-yellow in appearance. If not, do not use it and notify Baxter immediately.

8. Take off the blue cap from the BAXJECT II device and connect the syringe. BE CAREFUL TO NOT INJECT AIR. 9. Turn over the connected vials so that the RECOMBINATE vial is on top. Draw the RECOMBINATE solution into the syringe by pulling back the plunger slowly. Disconnect the syringe from the vials. Attach the infusion needle to the syringe using a winged (butterfly) infusion set, if available. Point the needle up and remove any air bubbles by gently tapping the syringe with your finger and slowly and carefully pushing air out of the syringe and needle. If you are using more than one vial of RECOMBINATE, the contents of more than one vial may be drawn into the same syringe. However, you will need a separate diluent and BAXJECT II device to mix each additional vial of RECOMBINATE. 10. Apply a tourniquet, and get the injection site ready by wiping the skin well with an alcohol swab (or other suitable solution suggested by your doctor or hemophilia center).

11. Insert the needle into the vein, and remove the tourniquet. Slowly infuse the RECOMBINATE. Do not infuse any faster than 10 ml per minute for RECOMBINATE dissolved with 10 ml of swfi. 12. Take the needle out of the vein and use sterile gauze to put pressure on the infusion site for several minutes. Do not recap the needle. Place it with the used syringe in a hard-walled Sharps container for proper disposal. 13. Remove the peel-off label from the RECOMBINATE vial and place it in your logbook. Clean any spilled blood with a freshly prepared mixture of 1 part bleach and 9 parts water, soap and water, or any household disinfecting solution.

14. Dispose of the used vials and BAXJECT II system in your hard-walled Sharps container, without taking them apart. Do not dispose of these supplies in ordinary household trash. Important: Contact your doctor or local Hemophilia Treatment Center if you experience any problems. Baxter, Recombinate, Hemofil, and Baxject are trademarks of Baxter International Inc. Manufactured by: Baxter Healthcare Corporation Westlake Village, CA 91362 USA U.S. License No. 140 Printed in USA