OFI Testing Equipment - Aging Cell Instructions Page 1 of 4. Instructions OFITE AGING CELLS

Similar documents
Aging Cell, OFITE Style. Included Items

High Temperature Aging Cell Instruction Manual. Manual No , Revision F

600 o F High Temperature Aging Cell Instruction Manual

Instruction Manual Updated 7/26/2011 Ver. 2.2

HTHP Filter Press with Threaded Cells for Drilling Fluids Testing. # : 115 Volt # : 230 Volt. Instruction Manual

Lost Circulation Material Evaluation Receiver Instruction Manual

HT4700 HPHT Filter Press Instruction Manual Manual No. D , Revision A Instrument Part Nos: , , ,

GREIG FILTERS, INC. OPERATION MANUAL

Instruction Manual. Updated 12/30/2014 Ver. 2.5

DUPLEX TECHNICAL INFORMATION FABRICATED DUPLEX STRAINERS

Instruction Manual Updated 5/26/2009 Ver. 2.0

SCF Enviro-Friendly. Back-up Ring. Endcap. #7141 (for both) O-Ring. Back-up ring and O-ring fit onto end cap.

High Pressure Equipment Taper Seal Valves, Fittings and Tubing

ST 18 Aluminium Gas Model

ST 18 Aluminium Gas Model

HTHP Filter Press for Ceramic Disks with 175-mL, Double-Capped Test Cell and CO 2 # : (115 V) # : (230 V) Instruction Manual

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

Summary of Accumulators These operating instructions apply to the accumulators listed in the table shown below.

TECHNICAL DATA CAUTION

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

Pressure Regulator B-95

1305 Series Pressure Reducing Regulators

Zero Head Space Extractor. Catalogue No. YT HW. Operation and Maintenance Manual

SALCO PRODUCTS, INC. PRESSURE RELIEF VALVE STORAGE, INSTALLATION, OPERATING, MAINTENANCE/TESTING, AND INSPECTION INSTRUCTIONS

Speed control assembly model A-1

Flange Bolt Torquing. for Resistoflex Plastic-Lined Piping Products. Torquing. Retorquing. Hydrotesting. Annual retorquing

TECHNICAL INSTRUCTIONS

2.5 & 5.0 GALLON PRESSURE TANKS

TECHNICAL DATA ACCELERATOR MODEL E-1

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Welker Magnetic Indicator (With Gravity Mixer) Model CP2GM-HP

Binks SG-2 Plus TM 2 QT. PRESSURE CUPS Model No (Standard) Model No (with OscillatingAgitator)

Continental Industries TRANSITION FITTINGS or FAX Visit

PANACEA P100 LOW PRESSURE USER MANUAL

Type BBS-03, BBS-05, BBS-06, BBS-25

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

Garrett Gas Train. Part No Instruction Manual. Updated 5/10/16 Ver. 4.0

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

BLADDER CARE INSTRUCTIONS

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP

Pneumatic retractable fitting for use with Unical 9000 and Uniclean 900 automated control systems

Recording Calcimeter with DAQ. # Standard # C - With Laptop. Instruction Manual. Updated 3/14/2017

SAFEsystem. Safety Apparatus Filter Enhancement. Filtration Systems. Now you can safely control your filtering process

Constant Pressure Crude Oil Container Model CPCCP

Installation, Operation, and Maintenance Manual

Garrett Gas Train Instruction Manual

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Solid Indicator (Non-mixer) Model CP-30SI

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

TECHNICAL DATA. Q= Cv S

DS05C,D,G Dial Set Pressure Regulating Valves

Air Operated Hydraulic Pumping Systems to 50,000 psi

Atmospheric relief valve type 1100 Installation and maintenance instructions

BR 27g. Operating, assembly and maintenance instructions for discontinuous sampling valve. 1. Design, operation and dimensions:

ZHE+ Zero Headspace Extractor Operation & Instruction Manual

Universal Charging and Testing Unit FPU-1

Installation Troubleshooting Maintenance Instructions Installation / Start-up

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions. IMPORTANT NOTICE

BGI, INC. WALTHAM, MA 02451

Pure-Flo Handwheel Operated Valves (903, 913, 963) Instruction Manual

Aluminum 13 cu tank Includes regulator Fill pressure: 3,000 psi (200 bar) Output: 1,100 psi +/- 10% (75bar)

American Meter Co. Five-Year Limited Warranty Industrial Regulators

Pneumatic Powered - Plunger Pumps

4-Ball Lowers 750cc, 1000cc, 1500cc, and 2000cc Models

TECHNICAL DATA. Q = C v P S

DuraSite 3000 Sample Vessel User's Guide. Version Rev-1

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Multi-Probe Sampling System User Guide & Manual

Dean Pump Self-Priming Chemical Process Pumps

Neotecha SAPRO - Tank Valve Type ST for aseptic sampling with bottles Installation, Operation and Maintenance Instruction

PNEUMATIC PRESSURE CONTROLLERS

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

Pressure Injection Cell Operator s Manual

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

SECTION BUTTERFLY VALVES

VB-7263 Series. Application. Features. Applicable Literature

Yoke Block Instruction Manual

1200B2 Series Service Regulators. Instruction Manual

PILOT OPERATED PRESSURE VACUUM RELIEF VALVE MODEL 1660

MUELLER GAS. No-Blo Operations Using D-5. Drilling Machine. Reliable Connections. General Information 2

4-W GAS ODORIZER WITH POSITIVE ACTION INDICATOR GAUGE (300 PSIG) 2014 INFORMATION MANUAL SUBMITTED BY:

9/6/11 RSPT Medical Gas Therapy. Manufacture, Storage and Delivery of Medical Gases Part 1

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

Pure Water Power Purification System 4-Stage RODI Operations Manual

PCS 340 Core Saturator : 115 Volt : 230 Volt. Instruction Manual

COSASCO 3600 PSI SINGLE SERVICE VALVE MAINTENANCE

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

TriPod Safety Coupler Installation & Operating Instructions for Models TP4, TP5, TP6, and TP7

DuraSite 500(1) Portable Sample Vessel User's Guide. Version (1) = 90 Duro Wetted O-Rings

Stirred Reactors and Pressure Vessels

Installation Instructions For Flat Seated Bolted Type RAH Series Disk Holders

Yoke Block Instruction Manual

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

HTHP Viscometer. Features DRILLING FLUIDS EQUIPMENT

Flexi-pro Aerosol Delivery System (FADS) Manual

Paintball Marker. User s Manual. 530 South Springbrook Road Newberg, OR 97132

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

Transcription:

OFI Testing Equipment - Aging Cell Instructions Page 1 of 4 Instructions OFITE AGING CELLS The OFITE Aging Cell is a patented pressure vessel that enables samples to be subjected to temperatures higher than the boiling point of water and still be maintained in a liquid state. The cells may be used for static temperature exposure or in a dynamic mode in a roller oven with a normal minimum aging time of 16 hours. OFITE Aging Cells are available in 260 ml and 500 ml sizes and utilize both Viton and Teflon O-rings seals. Aging cells are typically constructed of brass, grade 303 or grade 316 stainless steel. The stainless steel cells are used for high temperature testing, up to 450 F. For prolonged exposure to elevated salinity at high temperatures, e.g., 20,000 mg/l chlorides at 350 F, cells constructed from premium metals such as Hastalloy or Inconel 600 are available form OFITE. For corrosion testing, a special 500 ml, 303 alloy stainless steel Corrosion Test Cell is available with a modified inner cap designed to hold a corrosion coupon. The aging cell walls may be protected against corrosive fluids by using the popular Teflon liner, designed by OFITE. An optional calibrated rupture disc is available which can be installed in the inner cap to rupture and release pressure at a predetermined set point. OFITE can retrofit the rupture disc to existing cells. AGING CELLS, BRASS No. 175-00 AGING CELL, BRASS, 260 ML, NON - PRESSURIZED CELL #175-06 Set Screw, 5/8" diameter, stainless steel #175-08 Wrench, for 5/8" Set Screw #175-09-1 O-ring, Teflon, for Cell No. 175-01 No. 175-20 AGING CELL, BRASS, 260 ML, PRESSURIZED WITH VALVE AGING CELL, BRASS, 500 ML, PRESSURIZED WITH VALVE #175-10 Inner Cap, Brass #175-12 Outer Cap, Brass #175-14 Set screw, 3/8 " for pressurized Aging Cells #175-16 Valve Stem, for pressurized Aging Cells

OFI Testing Equipment - Aging Cell Instructions Page 2 of 4 AGING CELLS, STAINLESS STEEL, GRADE 303 No. 175-25 AGING CELL, 303 S.S., 260 ML, PRESSURIZED WITH VALVE No. 175-30 AGING CELL, 303 S.S., 500 ML, PRESSURIZED WITH VALVE #175-14 Set screw, 3/8" for Pressurized Aging Cells #175-16 Valve Stem, for Pressurized Aging Cells #175-18 Inner Cap, 303 stainless steel AGING CELLS, STAINLESS STEEL, GRADE 316 No. 175-50 AGING CELL, 316 S.S. 500 ML, PRESSURIZED WITH VALVE #175-14 Set screw, 3/8" for Pressurized Cells #175-16 Valve Stem, for Pressurized Aging Cells No. 175-40 CORROSION TEST CELL, GRADE, 303 STAINLESS STEEL, 500 ML #175-30 Aging Cell, 303 stainless steel, 500 ml, with Valve for Pressuring #175-45 Inner Cap, with Coupon Holder No. 175-60 LINER, TEFLON, For 500 ML AGING CELLS, COMPLETE #175-62 O-Ring, Viton, for Teflon Lid Liner Plug #175-63 O-Ring, Viton, for Teflon Liner Lid (Piston) PARTS AND ACCESSORIES FOR AGING CELLS: CAPS #175-10 Cap, Inner, Brass, for Pressurized Aging Cells #175-18 Cap, Inner, 303 S.S., for Pressurized Aging Cells #175-12 Cap, Outer, Brass, for Pressurized Aging Cells O-RINGS AND GASKETS #170-17 O-Ring, Viton, for Valve Stem, Viton #175-04 Gasket, Teflon, for Fann style inner Cap #175-09 O-Ring for inside of OFITE Aging Cell, Viton #175-09-1 O-Ring for inside of OFITE Aging Cell, Teflon #175-46 O-Ring for outside of Aging Cell, Teflon #175-54 O-Ring for outside of Aging Cell, Buna N SET SCREWS and WRENCHES

OFI Testing Equipment - Aging Cell Instructions Page 3 of 4 #175-06 Set Screw, 5/8", for Non Pressurized Cell #175-14 Set Screw, 3/8", for Pressurized Aging Cells #175-08 Wrench, Allen, for 5/8" Set Screw #175-15 Wrench, Allen, for 3/8" Set Screw VALVE STEM #175-16 Valve Stem, Short, for Aging Cells Procedure - Non-Pressurized Cells 1. Carefully inspect the o-ring for defects and place in the groove in the cell body. Replace the o-ring if it is hard or if cuts and nicks are present. 2. Pour the fluid sample into a clean aging cell to within one-half inch of the lip. This will allow sufficient void space for the expansion of the fluid due to heating. Avoid getting fluid in the o-ring groove or on the o-ring. 3. Clean any spilled fluid from the edge of the cell and place the inner cap on top of the cell body o-ring so that it seats in place. Hand tighten the outer cap in place, and using the Allen wrench, tighten the center set screw in the middle of the outer cap. 4. Place the aging cell inside the oven and adjust to the desired aging temperature. (See table no. 1) 5. After the desired aging time has elapsed, remove the cell from the oven and cool the cell to a temperature below 150 F (65 C). Loosen the set screw, unscrew the outer cap and remove the inner cap. 6. Observe the condition of the aged fluid and report as fluid, gelled, plastic or hard, etc. The aged fluid may also be tested for viscosity, shear or gel strength or filtration control. Procedure - Pressurized Cells 1. Carefully inspect the o-ring for defects and place in the groove in the cell body and the valve stem o- rings. Replace the o-ring if it is hard or if cuts and nicks are present. Make sure the valve stem is not plugged by blowing air through the stem. 2. Determine a safe volume and safe initial pressure for the temperature at which the sample will be tested. Place the correct volume of fluid into the cell and DO NOT OVERFILL THE CELL. (See table no. 1) Avoid getting fluid in the o-ring groove or on the o-ring. 3. Clean any spilled fluid from the edge of the cell and carefully place the inner cap onto the cell body o- ring so that it seats in place. Hand tighten the outer cap in place and with the Allen wrench, tighten the three set screws on top of the outer cap. Insert the valve stem with the o-rings in place into the inner cap and tighten all the way down. To pressurize the cell, loosen the valve stem approximately one half turn, and pressurize according to table no. 1. 4. When the proper pressure is reached, close the valve stem by tightening with the wrench. To ensure there are no leaks, the cell should be immersed in water and checked for any bubbles that might originate from the valve stem or cap.

OFI Testing Equipment - Aging Cell Instructions Page 4 of 4 5. Place the cell into a heating oven or chamber and heat to the desired temperature for the desired time interval. 6. Remove the cell from the heating chamber and air cool until the sample temperature has been reduced to 300 F (149 C) or less. The cell may then be either air or water cooled. The sample temperature must be at ambient temperature before the pressure is released and the cell is opened. Clean out the valve stem with water and blow out any residual water from inside the stem. 7. Observe the condition of the aged fluid and report as fluid, gelled, plastic or hard, etc. The aged fluid may also be tested for viscosity, shear or gel strength or filtration control. Aging Cells Mud Volume and Pressure for High Temperature Aging Aging Water Vapor Coef. of Suggested Mud Volume Mud Volume Temperature Pressure Expansion Applied ml, in ml, in F ( C) PSI for Water Pressure, PSI 260 ml Cell 500 ml Cell 212 (100) 14.7 ------ 25 225 ---- 250 (121) 30 ------ 50 225 ---- 300 (149) 67 ------ 100 200 ---- 350 (176) 135 ------ 150 200 ---- 400 (204) 247 1.16 250 ---- 350 450 (232) 423 1.20 300 ---- 350 500 (260) 680 1.27 375 ---- 350 550 (287) 1100 1.36 500 ---- 350 600 (315) 1543 1.47 580 ---- 300 CAUTION: Nitrous Oxide cartridges should not be used as pressure sources for high pressure, high temperature (HPHT) filtration. Under temperature and pressure, nitrous oxide can detonate in the presence of grease, oil or carbonaceous materials. Nitrous oxide cartridges are to be used only for Garrett Gas Train Carbonate Analysis. Carbon dioxide and Nitrous oxide cartridges are pressurized to approximately 900 psi at 1 atmosphere (sea level). Therefore they should never be placed on airplanes, without proper packaging, due to the possibility of cabin de-pressurizing which may result in an explosion.