RCD. Differential Pressure Flowmeters. for Liquids or Gases

Similar documents
RCD - Ultra-Rugged Differential Pressure Flowmeter

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

KMT. Thermal Mass Flow Meter. for Compressed Air and Gases. Measuring range: m3n/h m3 N

DMW. Direct Mass Flow Meter and Controller. for Gases. Measuring ranges from Nl/min air. Accuracy: ±3% of full scale

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

KMT. Thermal Mass Flowmeter. for compressed air and gases. Measuring range: Nm³/h Nm³/h

SCH-27. Diaphragm Pressure Switch. Setting range: mbar to bar. Temperature: max C. Material: stainless steel

E28/Q28 Safety Exhaust Valve Externally Monitored

Flow metering in gases Introduction to COMBIMASS family

Porter Analytical & Industrial Products

Thermal Energy Flowmeter Model KEC. Application Range. Special Features

Variable Area Flow Meters

P33 Safety Exhaust Valve Externally Monitored. Bulletin 0700-B14 ENGINEERING YOUR SUCCESS.

SITRANS P measuring instruments for pressure

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

Design Features. General Description

Pro-V Multivariable Flowmeter

[Instruments for vacuum measurement, checking and adjustment] 3

PanaFlow MV82. Insertion Style Multivariable Flowmeter. GE Measurement & Control. Key Benefits. Applications

Autocalibration Systems for In Situ Oxygen Analyzers

Pressure Transmitters 36 F-27839

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

TH-1800-T TRX-700-CNG Converter

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

analytical bulk flow distance FLOW level pressure temperature industrial communication

RCM 7000/8000 Series Liquid/Gas/Steam Flow Meter Differential Pressure Type, 1/4 to 8 Pipe, Alarm, Freq. & Analog Outputs

Orifice Plate Flow Meter

BULLETIN FOR ACCURATE INDICATION AND CONTROL OF GAS AND LIQUID FLOW IN LOW RANGES.

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

2/2-Way Proportional Valve (motor-driven)

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2

New! ProFlow. Sliding Vane Meters DN (½ - 2 ) _ 142. Product Bulletin

Choosing the right miniature instrument and control valve is a snap

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

2/ Port G1/4

780S Ultra High Purity Series

Ultrasonic level transmitter and indicator

PRO-50 Instrument Supply Regulator

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

TFE-LINED VAREA-METER PVC-TUBE VAREA-METER

Autocalibration Systems For In Situ Oxygen Analyzers

High Purity & Ultra High Purity

Model range*1) Switching pressure difference

CLARK 200 Series Vortex Flow Transmitter Frequency Output, 1/4 to 1.0 Pipe Sizes, Rugged Molded PPA Construction

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

Mass Flow Controller (MFC) for Gases

Digital Flow Switch. Series PFM7

QBS Electronic Pressure Regulator

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

For Multi-Parameter Meters see mvx

TF- & DM-Series. Turbineflowmeter

INSTALLATION & MAINTENANCE INSTRUCTIONS

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid

Varea-Meter Flowmeters. For Metering and Controlling Flows of Process Fluids

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

4 qwer 2/2 3/2 4/2. Intrinsically Safe. Air and Inert Gas Intrinsically Safe Valves Brass, or Stainless Steel Bodies 1/4" to 1" NPT SERIES.

C-Flow Coriolis Mass Flow Meters

CASH VALVE TYPE KP BACK PRESSURE VALVES

Smart performance with innovative and ever-strong coil drive even under harsh working environments

AFC. SDPROC and AFC Analog Mass Flow Controller ANALOG MASS FLOW CONTROLLERS. Principles of Operation. Design Features

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

SPD310/SPD360 Air Differential

High-performance submersible pressure transmitter For level measurement Model LH-10

Porter Lab & Analytical Products

NC MAGNETIC FLOAT SWITCHES FOR LIQUIDS

Variable area flowmeter F VA 250

TEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL

Mass Flow Meter (MFM) for gases

7Flat-Trak Model 780S. Smart In-Line Thermal Gas Mass Flow Meter with Flow Conditioner. For information online...

Level switches Series LD Vibrating fork level switch for liquids and solids

Level switches Series LD Vibrating fork level switch for liquids and solids

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

Micro Motion 7812 Fiscal Gas Density Meter

HighVac Pumps. High Vacuum Venturi Pumps. Modular Venturi Vacuum Pumps with Solenoid-Operated Vacuum and Blow-Off

Flow Measurement SITRANS F C

Pneumatic retractable fitting for use with Unical 9000 and Uniclean 900 automated control systems

Float Switches. for Liquids NSM, NSP, NAB, NEC, NST, NSE

Hydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN

Mass Flow Controller (MFC) for Gases

BSP Pressure Sensor Balluff GmbH, BA Marco Zorcic.

Mass Flow Meter (MFM) for Gases

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

9700 Transmitter Submersible hydrostatic level transmitter

Lesman Level Instrumentation LSB100/300 Series Basic Bubbler System

NC MAGNETIC FLOAT SWITCHES FOR LIQUIDS

Digital electro-pneumatic regulators Series ER100

Panel-Mounting Flowmeters Purge Set (Flowmeter with Constant Flow Valve)

Mass Flow Controllers

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

T208VR Series Tank Blanketing Vacuum Regulator

Pneumatic retractable fitting for simple commercially available control units or process applications

HAYWARD FLOW CONTROL TFS SERIES FLOW METER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

1/2 to 2-1/2 NPT; 0 to 230 PSI Advantages / Benefits

3.0 Pressure Transmitter Selection

Electric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42

Transcription:

ifferential Pressure Flowmeters for Liquids or Gases measuring monitoring analyzing R Measuring Ranges: 0.2...0.88 to 100...600 GPM (Water) 0.3...3.0 to 250...1650 SFM (Air) Accuracy: ± 3% of Full Scale Max. Pressure: 580 PSIG 1/2" to 3" Line Sizes Materials: Brass and 316L Stainless Steel Mechanical Indicator, igital Indicator, Transmitters, and Switches Available ustom alibrations for ensity and Viscosity 03/02-2016 KOBOL companies worldwide: ARGENTINA, AUSTRIA, BELGIUM, BULGARIA, ANAA, HILE, HINA, OLOMBIA, ZEH REPUBLI, EGYPT, FRANE, GERMANY, GREAT BRITAIN, HUNGARY, INIA, INONESIA, ITALY, MALAYSIA, MEXIO, NETHERLANS, PERU, POLAN, ROMANIA, SINGAPORE, SOUTH KOREA, SPAIN, SWITZERLAN, TAIWAN, THAILAN, TUNISIA, TURKEY, USA, VIETNAM KOBOL Instruments, Inc. 1801 Parkway View rive Pittsburgh, PA 15205 Main Office: 1.800.998.1020 1.412.788.4890 info@koboldusa.com

escription The R series differential pressure flowmeter measures flows of liquids and compressed gases using the orifice principle. The orifice, located in the flow body, generates a differential pressure which varies with the rate of flow. The differential pressure is applied to a measuring bellows. This is then linked either to a mechanical indicator or a Hall effect sensor, which is input to a compact or full featured electronic display and controller. This unique design, using a single measuring bellows, enables the accuracy to be unaffected by fluctuations in pressure. The meter movement is a single fulcrum lever design, with a minimal number of wear components, that is simple and reliable. It is available with brass or 316L stainless steel bodies ranging in size from 1/2" NPT to 3" NPT. The various electronic displays and control units offer a variety of options such as digital or bargraph displays, adjustable switches, and flow transmitters. Special scales are available for all media at any pressure and any temperature. Housing Gehäuse Flow urchfluss P 1 V 1 P 1 P 2 P 2 V 2 V 2 > V 1 => P 1 > P 2 Force Bewegung Magnet Bellows Faltenbalg Orifice Venturidüse Areas of Application OOMachinery Manufacturing OOhemical Industry OOHeavy Industry OOProcess Equipment Technical etails Measuring Accuracy: 3 % of Full Scale Repeatability: 1 % of Full Scale Process Temperature: Mechanical isplay: 32...212 F Electronic isplay: 32...176 F Ambient Temperature: Max. 176 F Max. Pressure: 360 PSIG (R-11 onnection: 3" NPT) 580 PSIG (All Others) Pressure Loss: Approx. 5 PSI Minimum Pressure: 10 PSIG Protection: IP 65 Materials isplay ase: ast Aluminum Front over: Polycarbonate Body: R-x1..: Brass R-x2..: 316L Stainless Steel ifferential Pressure Housing: R-x1..: Brass R-x2..: 316L Stainless Steel Pressure Meas. ell: 316L Stainless Steel Orifice: 316L Stainless Steel Seals: R-x1..: NBR R-x2..: FKM isplay/electronics: Mechanical Pointer Indicator: R-Z isplay: 270 Option: Special Scales for Other Gases and Liquids. Please Specify Media, ensity, Viscosity, Operating Pressure and Temperature ompact Electronics: R- isplay: 3-igit LE Analog Output: 4...20 ma Adjustable, Max. 500 Ω Switching Outputs: 1 (2) Semiconductor PNP or NPN, Factory Set ontact Operation: N/ / N/O Programmable Setting: Via 2 Buttons Supply: 24 V ± 20%, 3-wire, Approx. 100 ma Electrical onn.: Plug onnector M12 x 1 AI Electronics: R-K isplay: Bar Graph and 5-igit igital isplay Analog Output: 4...20 ma, 0-10 V 2 Switching Outputs: Relay/hangeover ontact, Max. 250 V A /5 A Resistive Load, Max. 30 V / 5 A Setting: Via 4 Buttons Supply: 100... 240 V A ± 10 % or 18... 30V A / 10... 40 V Electr. onnection: Pluggable Terminal Block Via able Gland 2

Order etails for Liquids: (Example: R 1106G N5 34P) Meas. Range Water* (GPM) Orifice Ø Model / Body Material Brass Stainless Steel onnection 0.2...0.88 2.80 R 1195G.. R 1295G.. 0.2...1.1 3.15 R 1100G.. R 1200G.. 0.2...1.3 3.50 R 1190G.. R 1290G.. 0.3...1.8 4.00 R 1191G.. R 1291G.. 0.3..2.2 4.50 R 1101G.. R 1201G.. 0.3...2.8 5.00 R 1192G.. R 1292G.. 0.5...3.5 5.60 R 1102G.. R 1202G.. 0.5...4.4 6.30 R 1103G.. R 1203G.. 1.0...5.6 7.10 R 1104G.. R 1204G.. 1.0...7.0 8.00 R 1106G.. R 1206G.. 1.0...9.0 9.00 R 1109G.. R 1209G.. 2.0...11 10.00 R 1110G.. R 1210G.. 2.0...15 11.20 R 1114G.. R 1214G.. 3.0...17 12.50 R 1115G.. R 1215G.. 3.0...22 14.00 R 1116G.. R 1216G.. 4.0...30 16.00 R 1117G.. R 1217G.. 5.0...35 17.50 R 1125G.. R 1225G....N8.. =1½" NPT 5.0...44 19.20 R 1130G.. R 1230G 10...70 26.00 R 1135G.. R 1235G.. 15...90 28.00 R 1137G.. R 1237G....N8.. = 1 ½" NPT 20...110 31.00 R 1139G.. R 1239G....N9.. = 2" NPT 20...140 33.50 R 1141G.. R 1241G.. 30...180 40.00 R 1145G.. R 1245G....N9.. = 2" NPT 30...240 43.50 R 1150G.. R 1250G....NB.. = 3" NPT 30...280 51.00 R 1155G.. R 1255G.. 50...400 60.00 R 1160G.. R 1260G....NB.. = 3" NPT 100...600 67.00 R 1165G.. R 1265G.. Order etails for Gases: (Example: R 1106S N5 34P) Meas. Range Air* (SFM) Orifice Ø Model / Body Material Brass Stainless Steel onnection 0.3...3.0 2.80 R 1195S.. R 1295S.. 0.5...4.0 3.15 R 1100S.. R 1200S.. 0.5...5.0 3.50 R 1190S.. R 1290S.. 1.0...6.5 4.00 R 1191S.. R 1291S.. 1.0...8.0 4.50 R 1101S.. R 1201S.. 1.0...10 5.00 R 1192S.. R 1292S.. 2.0...12 5.60 R 1102S.. R 1202S.. 2.0...16 6.30 R 1103S.. R 1203S.. 3.0...20 7.10 R 1104S.. R 1204S.. 3.0...25 8.00 R 1106S.. R 1206S.. 5.0...33 9.00 R 1109S.. R 1209S.. 5.0...40 10.00 R 1110S.. R 1210S.. 7.0...45 11.20 R 1114S.. R 1214S.. 10...55 12.50 R 1115S.. R 1215S.. 10...70 14.00 R 1116S.. R 1216S.. 15...95 16.00 R 1117S.. R 1217S.. 20...110 17.50 R 1125S.. R 1225S....N8.. =1½ NPT 25...130 19.20 R 1130S.. R 1230S.. 30...220 26.00 R 1135S.. R 1235S.. 40...300 28.00 R 1137S.. R 1237S....N8.. = 1 ½" NPT 50...380 31.00 R 1139S.. R 1239S....N9.. = 2" NPT 50...410 33.50 R 1141S.. R 1241S.. 100...540 40.00 R 1145S.. R 1245S....N9.. = 2" NPT 100...700 43.50 R 1150S.. R 1250S....NB.. = 3" NPT 125...800 51.00 R 1155S.. R 1255S.. 200...1200 60.00 R 1160S.. R 1260S....NB.. = 3" NPT 250...1650 67.00 R 1165S.. R 1265S.. Order etails: ontinued for Both Liquids and Gases Indicator Options Mechanical Pointer Indication Indication Flow irection..l.. = From Left..Z.. = Pointer Indicator, 270..R.. = From Right..B.. = From Bottom Location of Indication..L = Left..R = Right..T = Top..B = Bottom - -V alibration alibration for S.G other than Water (Required if S.G. is <0.95 or >1.05) alibration for Viscous Liquids (Required if S.G. is >10 cst) Note for Liquids: Measuring ranges are listed for water. alibrations for S.G. and/or viscosity may result in a slightly different final calibrated measuring range/fitting size. onsult the factory to determine the calibrated range/fitting size for the specified operating conditions. Full Size isplay/ontroller** Indication Power Supply Output Switches Note for Gases: Ranges are listed for air 0 PSIG at 70 F. alibration for compressed gases will result in a different final calibrated measuring range and/or fitting size. onsult the factory to determine the calibrated range/fitting size for the specified operating conditions...k.. = Bargraph/ igital LE isplay..0.. = 100-230 V A/..3.. = 18-30 V A, 10-40 V..0.. = None..4.. = 4-20 ma, 0-10 V..2 = 2 SPT Relays 807.007 Accessory Mating Micro- plug with 6 ft. able for ompact Electronic ompact Electronic** Indication Supply Output/ontacts..0R = 2x Open ollector, PNP... = igital..3.. = 24 V..0M = 2x Open ollector, NPN..4P = 4-20 ma, 1x Open ollector, PNP..4N = 4-20 ma; 1x Open ollector, NPN * See alibration Table above for etails about other Liquids and Gases. ** Please Specify Flow irection in the Order (Except from Top to Bottom) 3

R Head Loss vs. Flow Rate Net Pressure rop (PSI) Across Meter Percent of Rated Flow R Installation Piping Requirements Min. 10 X Pipe Ø Min. 5 X Pipe Ø In order to guarantee accurate readings, the R series must be installed with a minimum of 10 diameters of straight piping at the inlet and 5 diameters of straight piping at the outlet. This straight piping must be the same diameter as the flowmeter fittings and should have no bends, elbows, tees, or valves. 4

imensions R...Z with Mechanical Indicator A 4.57" 116 20 10 4.61" 117 3.58" 91 30 40 50 60 l/min 70 onnection A B Weight 1/2" NPT 7.52" 3.07" SW 27 5.63" 4.41 lb 3/4" NPT 7.52" 3.07" SW 41 5.63" 5.07 lb 1" NPT 7.52" 3.07" SW 41 5.63" 4.85 lb 1-1/2" NPT 8.11" 3.07" SW 55 6.22" 5.73 lb 2" NPT 8.03" 3.14" SW 70 6.14" 6.17 lb 3" NPT 8.70" 4.17" SW 100 6.81" 11.54 lb B connection Anschluss R... with ompact Electronics Ø 1.75" 44,5 onnection A B Weight 1/2" NPT 7.52" 3.07" SW 27 5.63" 4.63 lb 3/4" NPT 7.52" 3.07" SW 41 5.63" 5.29 lb 1" NPT 7.52" 3.07" SW 41 5.63" 4.85 lb 1-1/2" NPT 8.11" 3.07" SW 55 6.22" 5.73 lb 2" NPT 8.03" 3.14" SW 70 6.14" 6.39 lb 3" NPT 8.70" 4.17" SW 100 6.81" 11.46 lb Gewinde thread 2.01" 51 B R...K with AI-Electronics 4.57" 116 4.61" 117 5.00" 127 OBOL S1 S2 P AI-1 A onnection A B Weight 1/2" NPT 7.52" 3.07" SW 27 5.63" 7.50 lb 3/4" NPT 7.52" 3.07" SW 41 5.63" 8.16 lb 1" NPT 7.52" 3.07" SW 41 5.63" 7.94 lb 1-1/2" NPT 8.11" 3.07" SW 55 6.22" 8.60 lb 2" NPT 8.03" 3.14" SW 70 6.14" 9.26 lb 3" NPT 8.70" 4.17" SW 100 6.81" 14.30 lb B Gewinde thread 45,5 1.79" 5

Please Fax to: KOBOL Instruments Inc. US: 412-788-4890 anada: 514-428-8899 * Accurate process information is essential to ensure proper operation. Please fill out form completely. Please retain the completed form and submit it with your order. General onditions ustomer Name: ompany Name: Phone: Fax: E-mail: ate: 1. Pressure: Maximum PSIG 2. Temperature: Maximum F alibration onditions (Accurate data is required for factory calibration to ensure accurate readings at normal operating conditions.) Liquid Flow Applications 1. Liquid Type: 2. Normal Operating Temperature: F 3. Viscosity at Normal Operating Temperature: 4. Specific Gravity at Normal Oper. Temp: 5. esired Measuring Range and Units: Note: Items 3 and 4 are not required for water flow. Gas Flow Applications 1. Type of Gas: 2. Normal Operating Temperature: F 3. Normal Pressure at Outlet Fitting: 4. Specific Gravity (for Gas Mixes Only): 5. esired Measuring Range and Units: Note: The calibration pressure required is the pressure that the meter sees at its outlet fitting. Flowmeter Options 1. Body Material: Brass with NBR Seal 316L SS with FKM Seal 2. Fitting Size: 1/2" NPT 3/4" NPT 1" NPT 1-1/2" NPT 2" NPT 3" NPT 3. Flow irection: Left to Right Right to Left Flow Up, ial on Right Flow Up, ial on Left Flow own, ial on Right Flow own, ial on Left Indicator Options 1. R-Z: Mechanical Indicator 2. R-: ompact Electronics 2 PNP Switches 2 NPN Switches 4-20 ma, 1 PNP 4-20 ma, 1 NPN 3. R-K: igital isplay/ontroller Input Power: 100-230 Vac/dc 18-30 Vac/10-40 Vdc Output: None 4-20 ma Relays: 2 SPT Relays Standard 6