SPECIFICATIONS - DETAILED PROVISIONS Section Butterfly Valves C O N T E N T S

Similar documents
SECTION BUTTERFLY VALVES

Section GATE VALVES

SECTION PRESSURE TESTING OF PIPING

SECTION VALVES AND APPURTENANCES

Homestead Series 820 AWWA Butterfly Valves

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108

SECTION N SPECIAL EQUIPMENT SPECIFICATIONS

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

Team Insert Valve Sample Specification The Insert Valve shall conform to the following:

STANDARD SPECIFICATION FOR SPLIT TEES (HOT TAP MATERIAL)

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

BUTTERFLY VALVES Series 800

American-BFV. Copyright 2008 Val-Matic Valve & Mfg. Corp 1

MUELLER. Xp, & Lineseal 350 Butterfly Valves

Installation, operation & maintenance manual - original version

KENNEDY VALVE OPERATION & MAINTENANCE MANUAL

Henry Pratt Diviner Position Indicator. Operation and Maintenance Manual. Job Name: Contractor: Date: Document #:DIVPOSNOM Revision Date: 2/9/11

FLANGED TWO-PIECE BALL VALVES

INSTALLATION, OPERATION & MAINTENANCE MANUAL

SECTION 25 TESTING AND DISINFECTING WATER MAINS General

FLANGED TWO-PIECE BALL VALVES

San Antonio Water System Standard Specifications for Construction ITEM NO. 841 HYDROSTATIC TESTING OPERATIONS

LARGE R/W GATE VALVES

SECTION DOMESTIC WATER PIPING

ASSE International Product (Seal) Listing Program. ASSE Performance Requirements for Air Valve and Vent Inflow Preventer

Instructions for Installation, Operating and Maintenance

2-port seat valves PN25 with externally threaded connections

CLASS D - SENSITIVE LEAK TEST GAS AND BUBBLE METHOD. 1.1 To provide definitive requirements for PNEUMATIC pressure testing of piping systems.

AIRMASTER SERIES RF AUTOMATIC DEWATERING VALVES. For the purging of water from compressed air systems WHERE DO YOU NEED AUTOMATIC DEWATERING VALVES

INSTALLATION COMMISSIONING, OPERATION & MAINTENANCE MANUAL

SITE WATER UTILITY DISTRIBUTION PIPING

SUPPLY OF ISOLATION AND APPLIANCE VALVES PTS - ISOLATION BALL VALVE

RESILIENT SEATED GATE VALVES FOR WATER & WASTEWATER INDUSTRY RESILIENT SEATED GATE VALVES & AWWA BUTTERFLY VALVES

NAVSEA STANDARD ITEM. 2.2 T9074-AS-GIB-010/271, Requirements for Nondestructive Testing Methods

Sample Procurement Specifications for Aluminum Traffic Control Signs and Components

Installation, Operation and Maintenance Manual for Back Pressure Regulator

HYDROVEX TTT Membrane Flow Regulator

TBV OPERATION AND MAINTENANCE MANUAL SERIES 2800: FLANGED BALL VALVE. For technical questions, please contact the following:

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

Spilt body Flange ball valve. TC-205MFF-PN1640 User Manual English Version. Document No: TC-205MFF-PN1640.Ur-manual. Date: 2007/04/2617. Version: 1.

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections

Horizontal Bladder Tanks

ASSE International Product (Seal) Listing Program

USER INSTRUCTIONS. NAF Duball DL Ball Valves. Installation Operation Maintenance. Experience In Motion. flowserve.com

CLEANING, INSPECTION, AND TESTING OF SEWERS

KENNEDY AWWA C515 RESILIENT WEDGE GATE VALVES (2000)

Testing Procedures of Watertight Compartments

Loss Prevention Standard

Vertical Bladder Tanks

FLANGED MULTI-PORT BALL VALVES

Leak testing of Valves. Standards for acceptable Rates of Valve Leakage

Hot Tapping Machine. OPERATIONS MANUAL and OPERATING INSTRUCTIONS

IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC PURPOSE

PIP PNE00012 Piping Examination and Leak Test Guide

SAN ANTONIO WATER SYSTEM I.H. 10 Ground Storage Tank Rehabilitation and Painting Project SAWS Job No Solicitation No.

Model PIV UL/FM Post Indicator Valve. Maintenance and Operation Manual UL/FM Post Indicator Valve Configuration AWWA C515

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

APPENDIX B TESTING PROTOCOLS. Method A: Straight Test Method B: Angular Deflection Test. Method C: Shear Load Test

INSTALLATION & MAINTENANCE INSTRUCTIONS - ORIGINAL VERSION AVK KNIFE GATE VALVES

Engineering Data Sheet

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Manual Actuated Boiler Blowdown Valves

Carter Option X Valve connector assembly. Maintenance manual

CONTROL VALVE TESTING

TEST SPECIFICATION NYT-909-C

Bermad Pressure Reducing. Model: 42T

Model MTB-ASME Horizontal Bladder Tanks

MLS Series Liquid Level Switches. Installation and Operations Manual Section 15

Model MTB-ASME Vertical Bladder Tanks

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

Model MTB-ASME Vertical Bladder Tanks

High Pressure Iron (HPI) Recertification Guidelines & Procedures

Type Testing Procedure for Crankcase Explosion Relief Valves

RP series Rotor Pumps

WHEATLEY Series 500 Swing Check Valve

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

OPERATING MANUAL. Contents. Bottom outlet ball valve Type ecoline

MODEL 2638 AWWA C515 REDUCED WALL DUCTILE IRON

Date of Issue: July 2016 Affected Publication: API Specification 16C, Choke and Kill Equipment, Second Edition, March 2015 ADDENDUM 1

Specification For Water Meters. Pr10068

CYL KNIFE GATE VALVES San Sebastian Spain

Instruction Manual. CG16K Barometrically Compensated Capsule Dial Gauge. CG16K Capsule Dial Gauge, 0 to 25 mbar

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER RELIEF VALVE

Telefon (+45) Telefax (+45)

Installation & Operation Manual Proven Quality since 1892

Vertical and Horizontal Bladder Tanks

Automatic Non-freeze Valve NF6

MUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5

SUPPLY OF ISOLATION AND APPLIANCE VALVES PTS - APPLIANCE BALL VALVE

AVK SERIES 601, 602, 603 & 605 UNIVERSAL COUPLINGS, ADAPTORS & END CAPS INSTALLATION, OPERATION & MAINTENANCE MANUAL

V43 Pressure Actuated Water Regulating Valve

Model Safety Program

Two-port valves, male threaded, PN25

INSTRUCTION MANUAL. Anchor Darling 800 Globe Valves. Installation Operation Maintenance. Sizes 1/2 through 2 FCD ADENIM

TECHNICAL DATA Q= C. Table 1 - Specifications

Transcription:

SPECIFICATIONS - DETAILED PROVISIONS Section 15103 - Butterfly Valves C O N T E N T S PART 1 - GENERAL... 1 1.01 REQUIREMENT... 1 1.02 VALVE MANUFACTURER... 1 1.03 GUARANTEE... 1 PART 2 - PRODUCT... 1 2.01 VALVES... 1 2.02 VALVE ENDS... 1 2.03 OPERATORS... 2 2.04 TESTS... 2 2.05 COATINGS... 3 Rev: 01/20/06

Section 15103 1 SECTION 15103 BUTTERFLY VALVES PART 1 - GENERAL 1.01 REQUIREMENT Butterfly valves for buried water system service. Under this specification the Contractor shall be required to furnish, deliver, and unload within the time specified in the Special Conditions, the butterfly valves as specified on the bidding sheets and hereinafter described in these specifications. 1.02 VALVE MANUFACTURER The name of the manufacturer of the valves to be furnished by the bidder shall be stated on the bidding sheets. Inasmuch as valves require an in-service review over an extended period of time for evaluation by the District for acceptance, it is necessary that proposed valves other than those specified must be submitted for evaluation well in advance of the bid opening, for acceptance prior to the award of the contract. Generally, the specified 35-day period following issuance of the Acceptance-of-Proposal will not result in approval of alternate valves. 1.03 GUARANTEE The Contractor shall guarantee all materials and workmanship of items furnished under these specifications to be free from defects for a period of one (1) year after final completion and acceptance of the entire contract work. The Contractor shall, at his own expense, repair or replace all defective materials or workmanship supplied by him found to be deficient with respect to any provisions of this specification. PART 2 - PRODUCT 2.01 VALVES Butterfly valves shall conform to the latest revision of AWWA Standard C-504 for rubber-seated butterfly valves, subject to the following requirements: Valves shall be of Class 150B, shall have 125-lb. American Standard flanges and, unless otherwise shown, shall be short-bodied. Shaft seals shall be rubber "O"-ring, and journal packing shall be rubber or split-v type packing. All valves shall be new and of current manufacture and shall be per EMWD Acceptance list. 2.02 VALVE ENDS Shall be as specified on the bidding sheet; either flanged both ends, hub-end both ends, or one flanged end and one hub-end, as required, conforming to the following specifications:

Section 15103 2 A. Flanged End. Flanged ends shall be designed for the water pressure as specified in AWWA C-504 and drilled to the American Standard for 125# Cast Iron Flanges, and flange face shall not be raised. Flange face shall have standard machine finish. B. Hub-End. Hub-ends shall be designed for the water pressure as specified in AWWA C-504 and shall be "Ring-tite" or approved equal. 2.03 OPERATORS The valve shall be provided with a totally enclosed buried service operator designed for the full working pressure across the disc and conforming to the requirements of the above-referenced AWWA Standard. Valves shall be installed with the shaft in a horizontal position. The operators shall be side-mounted, equipped with a 2" operating nut and have a raised boss at the input shaft to accommodate a 5" pipe. The operating torque rating shall conform to Table I of the above referenced AWWA Standard for the pressure classification specified, and shall be designed in accordance with the requirements of AWWA C-504-80 Appendix. Operator input torque ratings shall fully comply with the above referenced AWWA Standard. Operation shall be clockwise to close, counterclockwise to open. The minimum number of turns to close valve shall have a minimum of two (2) turns per diameter inch and a maximum of five (5) turns per diameter inch of valve size. Valve operator shall be oriented with respect to pipeline intersection in accordance with standard drawing No. B-577. 2.04 TESTS Each valve body shall be tested by the manufacturer under a test pressure equal to twice its design water working pressure, and shall be shop-operated three (3) times in accordance with the requirements of AWWA Standard C-504. C. BUTTERFLY VALVES LARGER THAN 12-INCHES Butterfly Valve Testing. Butterfly valves with size greater than 12 inches shall be hydrostatically tested per AWWA C504 in both directions. This test shall be conducted within 50 miles of the District office and shall be performed in the presence of the District. No valve shall be installed until this testing has been completed and approved by the District. Each valve shall be tested as detailed in the District Standard Specifications and as specified below: 1. Visually inspect each valve and its actuator for compliance with the submittal. 2. Visually inspect each valve for obvious damage or substandard construction. 3. The testing medium shall be water. Under no circumstances is air to be used as the test medium.

Section 15103 3 4. Each valve is to be tested at its rated pressure. 5. Both sides of each valve are to be tested. 6. The test duration on each side of the valve is 5 minutes. A passing test is one where there is no visible leakage and no decrease on the initial test pressure. 7. A valve which fails the pressure test shall be either repaired or replaced. Repaired valves shall be retested. Replacement valves shall be tested using this procedure. 8. Valves shall only be repaired by personnel authorized by the valve manufacturer to do the necessary repairs. Unless they have been authorized by the valve manufacturer, supplier or contractor shall not be permitted to perform repairs. 2.05 COATINGS A. All valves shall have internal and external ferrous parts epoxy coated. Wetted surfaces shall have an 8 mil minimum (dry film) thickness, unless otherwise specified. The epoxy shall be approved for potable water, and shall conform to AWWA C-550. B. All coated surfaces shall be visually and electrically examined for defects. The coating shall be holiday free as determined by a low voltage wet sponge test per AWWA C-550. END OF SECTION 15103

Section 15103 4 [PAGE LEFT INTENTIONALLY BLANK]