Circulating Lubrication Systems (Oil)

Similar documents
Circulating Lubrication Systems (Oil)

Accessories for Progressive Systems

for the lubrication of spindles, linear guides, rack pinions, chains, assembly processes

Oil+Air Systems. for the lubrication of spindles, linear guides, rack pinions. Functional principle and application

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

Fixed Displacement Pump KFA for commercial vehicles in open circuits

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

OWNER S TECHNICAL MANUAL

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

Pressure reducing valve, pilot operated, Model 3DR

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

Controllers DR, DP, FR and DFR

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

Self-operated Pressure Regulators for special applications

Technical Data Sheet TI-F50 Locking Units series KFH

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Air service units series K G1/8, G1/4

Pressure and Flow Control Valves DBGM, German and European Patents

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Old documentation - Only for your information! Product is not available anymore!

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

HERZ-Motorised flow controler

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Type 4708 Supply Pressure Regulator

Type 4708 Supply Pressure Regulator

D 042 D 062 In-line mounting Operating pressure up to 100 bar Nominal flow rate up to 90 l/min

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

PLD 03 T A CASAPPA S.p.A.

Series K Air service units G 1/8, G 1/4

Pressure relief valve DHV 716 set range: 0,5-10,0 bar

Precision Pressure Regulators

Control Units for Oil+Air Lubrication

4/2 way Pneumatic Solenoid Valve

Mass Flow Meter (MFM) for Gases

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design

E 212 E 222 Tank top mounting Connection up to G1¼ Nominal flow rate up to 220 l/min

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

ALF400 to 900, ALT-5/-9

Air preparation units

Operating manual for Material pressure tanks Vol./1 and Vol./2

Mass Flow Controller (MFC) for Gases

PRESSURE TEST PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model No: PTP100. Part No: GC01/09

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Fixed Displacement Motor A4FM

Pressure relief valve DHV 725 set range: 0,2-10,0 bar

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Pressure Relief Valve DHV 718

Operating and maintenance manual Filter and reducing station Series / 1.0

Two-stage valve type NE

APPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

Pressure reducing valve, pilot operated

E 441 E 451 E 461 E 641 E 700 Tank mounting Nominal flow rate up to 800 l/min

SERIES 500 VARIABLE RANGE PNEUMATIC DIFFERENTIAL PRESSURE TRANSMITTER

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

Self-operated Pressure Regulators Type Universal Pressure Reducing Valve

MPS/MST SPIN - ON FILTER SUCTION - RETURN SERIES. Maximum working pressure 12 bar. Flow rates to 300 l/min

CALEFFI. Ball zone valves. series /03 GB

ARI-DP32 / DP33 / DP34 / DP34T / DP34Tri / DP35 Pneumatic actuator ARI-DP

Gas Pressure Regulator HON 300

Operating Instructions for Flow Restrictors. Model: REG

ACCU-MIX 1200 / / 26270

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

Compact pressure switches for gas and air

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

D62 - D63 Directional Control Valve l/min

F l o w c o n T R o l v a l v E S

Pressure Relief Valves. SPV, SPVF direct operated

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

VB85/ Pressure regulating valve (Unloader)

Pressure-controlled shut-off valve type CNE

North American Orifice Metering System

Product Sheet Spraymist Unit

PRO SINK -R 1 and 2. Dilution system CONTENTS

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X

Hand lever valves VHER

Safety Relief Valve HON 832

SKF LubriLean DigitalSuper

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

The number of test stands can be adapted to the special requirements.

Fixed Displacement Plug-In Motor A2FE

ALF400 to 900, ALT-5/-9

Wide opening parallel grippers Series CGLN

Y:\Machine Manuals & Spare Parts Lists\PARTS BREAKDOWN\Commercial CW Gas\HD850WS Page 1

ALF400 to 900, ALT-5/-9

Mass Flow Controller (MFC) for Gases

Actuator HON 670 / 671

RMS. Quick Change System. for manual chucking tool change. Advantages: Convenient chucking tool changes without the slightest sacrifice to safety.

GM Series Dual-Block Multi-Function Gas Control Valves

OPERATING INSTRUCTIONS

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Transcription:

--EN Circulating Lubrication Systems (Oil) Screw-in Restrictors, Metering Valve Distributors, low Volume Dividers Screw-in restrictor Metering valve distributor low volume divider SP/SMT (cf. leaflet -7-EN) A continuous flow oil is often necessary for the lubrication or cooling of machines or systems requiring large amounts of oil. This flow is produced by gear, gerotor, vane and piston pumps and then distributed to meet the needs of the individual lube points. The system is very simple if there is only one lube point to be supplied. But if the lubricant is to be delivered to a number of lube points in equal quantities or certain proportions, there are several possibilities entailing different expenses and effects. If must be remembered that circulating lubrication systems require an oil return line from the lube points to the oil reservoir. Adequate filtering of the oil must be provided for. Restrictors, especially for small amounts of oil, are sensitive to dirt.

Circulating Lubrication Systems (Oil) Distribution systems System description M a Restrictor tubes A pump supplies a network of lines connected to all the lube points via manifolds and branch lines. The quantity is apportioned in inverse proportion to the resistance of the restrictor tubes, screw-in restrictors or metering valve distributors. b Screw-in restrictors and adjust. metering valve distributors Screw-in restrictors can be installed on manifolds (cf. leaflet --EN or screwed directly into the threads of the lube points. c low monitors with choke System similar to b, but the interchangeable metering valve is installed upstream of a flow monitor in which an electrical contact is actuated by a piston moved by the oil flow. The contact returns to its neutral position when there is oil pressure without a simultaneous flow of oil. See leaflet -7-EN VPM- T T T G/8 The flow from the pump is divided up by a feeder. G/ VPG- S S S G G/ G/8 Progressive feeders The flow from this master feeder can be further divided up for up to a total of some lube points by way of downstream progressive feeders. See leaflets --EN to -7-EN Multi-circuit pumps Multi-circuit pumps (e.g.,,, 8,, zones) supply the lube points direct with prespecified quantities of oil that correspond to the pumps delivery rates. It is possible to work with or without priming pressure, depending on the operating pressures and accuracy requirements to be expected. Subdistribution of the individual zones is possible in accordance with systems and. See leaflet --EN low volume divider The oil is distributed via non-adjustable flow dividers. The volumetric flow in the main line is divided up into individual parallel flows. Secondary distribution as per systems and is possible. See leaflet -7-EN IAuxiliary equipment for systems a and b is specified in this leaflet. --EN

Volumetric flow per lube point Perm. operating pressure [bar] Max. number of lubrication points Monitoring General remarks and criteria a few cm³ to several l/min Screw-in restrictors:. cm³/min Metering valve cm³/min. l/min Unlimited in practice. Tubing cross sections and pump have to be adapted. No monitoring of individual points, pressure can only be monitored in the main line. Oil flow is monitored. An alarm is triggered if the flow drops below the bottom limit of the range for the flow monitor selected. a or an even distribution of oil provide for the most symmetric layout possible. Lay tubing with the largest possible cross sections from the pump to the junctions. When individual points require different amounts of oil, change the lengths or cross sections of the restrictor tubes to obtain the respectively needed quantity. Inexpensive, reliable, insensitive to dirt. Planning is complicated when extensive, asymmetric systems with different oil needs are involved. b c Restrictors can clog up when unfiltered oil is used. It is therefore necessary to install a microfilter upstream in the systems, preferably with a dirt indicator. Planning and quantity regulation easy. The pressure losses in the tubing have to be taken into account when the system is designed. a b c Metering imprecise with fluctuating and varying back pressures. Often of no importance in circulating lubrication systems not used for cooling purposes at the same time. The systems do not depend on the viscosity. a few cm³ to l/min Pressure should not exceed bars in circulating lubrication systems. to roughly Central monitoring of functions of all distributors easy since system-related. Pulsating oil current. Very exact apportioning of quantities, even with back pressures. Planning complicated, especially changes at a later date. The systems depend on the viscosity. Easy to plan... l/min per outlet or 8 depending on pump,,, 8,, zones per pump Monitoring of one or more strings of lines with flow monitors or the like possible. A monitored string of lines already shows the pump is operating and lubricant is available. The lower the pressure difference between the priming pump and distributing pump the more even the delivery rates are in relation to each other.,9 l/min per outlet port Max. depending on flow divider Limited in practice. Monitoring of one or more strings possible due to system. The incoming volumetric flow is divided up into individual parallel flows. The volumetric flow produced does not depend on the system pressure and is nearly independent of the viscosity. The individual volumetric flow rate can be altered by an exchange of plug-in nozzles. --EN

Screw-in restrictors See important product usage information on the back cover. Type A Port tapped for solderless tube connection. M8 Screw-in restrictors are used to deliver relatively small amounts of oil to the lube points. The sizes are identified by code numbers. Screw-in restrictors of types C and D additionally contain one check valve each that can help to prevent leaks, for instance. ø WA The diagrams show the flow rates of the individual sizes as a function of the pressure and as measured with an operating viscosity of the oil amounting to mm /s. The flow rate varies with the viscosity. The scope of delivery also covers union nuts and tapered rings when types C or D are ordered. M 7. The restrictors are marked with a direction arrow.the types A and D can either be combined and fitted to manifolds (cf. leaflet --EN) or types B and C directly screwed into the ports of the individual lube points. Special attention must be paid to the use of clean oil, the recommended filter size being µm. Diagramm (types A and B) flow rate [ccm/min] pressure [bar] code number Type B M ø M Port tapped for solderless tube connection. WA 7. for tube Order No. diam. Code No. Type VD- VD- VD- VD- VD- VD-7 7 VD-8 8 VD-9 9 VD- VD- VD- B VD- VD-9 9 A Diagram (types A and B) flow rate [ccm/min] pressure [bar] code number 9 8 7 Type C M tap. ø WA WA. Washer, order No. -9 for tube Order No. diam. Code No. Type VD-99 VD- VD- VD- Tube connection acc. to DIN for tube Order No. diam. Code No. Type VD-99 VD- Washer, order No. DIN 7-A8.-CU C D Diagram (types C and D) flow rate [ccm/min] pressure [bar] code number Type D M8 ø WA WA --EN

Connecting piece with restrictor (compl. with washer) Nomograph for determination of restrictor size Code No. for tube Connection Code Order No. diam. thread ) No. GD GD GD M. GD GD GD GD8 8 GD8 8 GD8 8 GD8 8 GD8 M. 8 GD8 8 GD8 8 GD87 87 GD88 88 GD89 89 ) Ports tapped for solderless tube connection to DIN (cutting sleeve) Determining the restrictor size. Draw a straight line along the index lines through point Q eff.. Determine the point at which pintersects with this line, resulting in D.. Select the restrictor closest to point D. D must be inside the white field, i.e. small amounts cannot be apportioned and monitored with the unit. Example required: Q = cm³/min, given:ν ν eff = 8 mm /s, p = 7 bar Result: restrictor size No. (borderline case) Example required: Q = cm³/min, given:ν ν eff = 8 mm /s, p = 8 bar Result: restrictor size No. 8 Operating viscosity ν eff. [mm /s] Operating viscosity ν eff. [mm /s] Lubricant quantity Q [cm³/min] Code No. Lubricant quantity Q [cm³/min] min. system pressure Pressure p [bar] Pressure p [bar] min. system pressure --EN

Metering valve distributors Type A l These metering valve distributors are used if an infinitely variable adjustment of the flow rate per lube point is required even at a later date. In the case of type A for flow rates within the drop-feed range knurled lock nuts and knurled screws are provided for adjustment purposes. It is necessary to provide for a sufficiently large drain-off in order to maintain a free fall of drops in the sight-glass.. l 7 M 9 8 max. 9 M spacer WA ø7. In the case of types B and C, the continuous flow rate is adjusted after the upper hexagonal lock nut is loosened. Spring-loaded metal pins in sight glasses indicate that oil is flowing when they move away from the mark. l ) M for mm diam. tube ) Ports tapped for solderless tube connection Technical data Type B Operating pressure........... bars Viskosity range............. to mm /s Temperature range........... to + C Mounting position........... as shown Output range type A................ to cm³/min type B............... to cm³/min type C................ to cm³/min l. l M max. 9 M WA WA ø7. Indicating range B and C at mm /s commencement of indication.... at cm³/min end of indication.......... at or cm³/min 7 9 8 spacer WA Number of Dimensions [mm] Order No. lube points l l l Type -. A -. 9 7 A -. 8 A -. A l Type C ) M for mm diam. tube ) Ports tapped for solderless tube connection -. 9 7 B -. 7 B -. 8 B -. 8 B -. 7 8 8 B -. 8 B -. 9 7 87 B -. C -. 89 C -. 9 C -. 9 9 C -. 8 9 C l l M8. max. 97 M spacer WA WA ø7. Adapter for main tube Types A and B Type C - for mm diam. -8 for mm diam. 8- for 8 mm diam. - for mm diam. - for mm diam. Screw plug 8- - Washer 8--CU DIN7-A8 -CU. l ) M. for mm diam. tube WA 9 ) Ports tapped for solderless tube connection --EN

Layout of a circulating lubrication system (printing machine) with progressive feeders VPG- T VPG- VPG- T VPG- T T T T S S S S S T S T --EN 7

Order No. --EN Subject to change without notice! (7/9) Important product usage information All products from SK may be used only for their intended purpose as described in this brochure and in any instructions. If operating instructions are supplied with the products, they must be read and followed. Not all lubricants are suitable for use in centralized lubrication systems. SK does offer an inspection service to test customer supplied lubricant to determine if it can be used in a centralized system. SK lubrication systems or their components are not approved for use with gases, liquefied gases, pressurized gases in solution and fluids with a vapor pressure exceeding normal atmospheric pressure ( mbars) by more than. bar at their maximum permissible temperature. Hazardous materials of any kind, especially the materials classified as hazardous by European Community Directive EC 7/8/EEC, Article, Par., may only be used to fill SK centralized lubrication systems and components and delivered and/or distributed with the same after consulting with and receiving written approval from SK. urther brochures -9-EN Transport of Lubricants in Centralized Lubrication Systems SK Lubrication Systems Germany AG Motzener Strasse /7 77 Berlin Germany P 97 7 Berlin Germany Tel. +9 () 7- ax +9 () 7- www.skf.com/lubrication This brochure was presented by: SK is a registered trademark of the SK Group. SK Group 9 The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct, indirect or consequential arising out of the use of the information contained herein.