Introduction to AAE520 Forebody/LDV Lab

Similar documents
Introduction to AAE520 Forebody/LDV Lab

Cover Page for Lab Report Group Portion. Flow Visualization in a Water Channel

Cover Page for Lab Report Group Portion. Boundary Layer Measurements

Cover Page for Lab Report Group Portion. Lift on a Wing

Cover Page for Lab Report Group Portion. Pump Performance

Lab 4: Pressure Gradients over a Wing

Cover Page for Lab Report Group Portion. Head Losses in Pipes

A & AE 520 Background Information, Adapted from AAE334L, last revised 10-Feb-14 Page 1 1. SUPERSONIC WIND TUNNEL

Cover Page for Lab Report Group Portion. Drag on Spheres

HYDRAULICS. H89.8D - Hydraulic Bench

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

Subsonic Wind Tunnel 300 mm

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

Aerodynamic Measures for the Vortex-induced Vibration of π-shape Composite Girder in Cable-stayed Bridge

Hydrogen Bubble Seeding for Particle Image Velocimetry

Deploying the TCM-1 Tilt Current Meter in an Inverted (Hanging) Orientation By: Nick Lowell, Founder & President

Lecture # 08: Boundary Layer Flows and Controls

LAMINAR FLAME SPEED ANALYSIS USING PIV (PARTICLE IMAGE VELOCIMETRY)

Level MEASUREMENT 1/2016


LABORATORY EXPERIMENTS ON WAVE OVERTOPPING OVER SMOOTH AND STEPPED GENTLE SLOPE SEAWALLS

User Manual for the Mars Calibration Bench

Unsteady airfoil experiments

User s Booklet for the Wyatt minidawn Light Scattering Instrumentation

Keywords: dynamic stall, free stream turbulence, pitching airfoil

REVIEW OF METHODS AND TECHNIQUES FOR THE ASSESMENT OF WINDS AT PEDESTRIAN LEVEL

EXPERIMENTAL ANALYSIS OF FLOW OVER SYMMETRICAL AEROFOIL Mayank Pawar 1, Zankhan Sonara 2 1,2

Long Win s Educational Facilities for Fluid Mechanics

BASIC Z-STACK AND TIME SERIES SCAN ON THE ZEISS LIGHTSHEET Z. 1

FLOW VISUALIZATION TUNNEL

Lecture # 08: Boundary Layer Flows and Drag

ISS0065 Control Instrumentation Lecture 12

Model 130M Pneumatic Controller

AN EXPERIMENTAL STUDY OF THE EFFECTS OF SWEPT ANGLE ON THE BOUNDARY LAYER OF THE 2D WING

AE3051 Experimental Fluid Dynamics PRESSURE MEASUREMENTS AND FLOW VISUALIZATION IN SUBSONIC WIND TUNNELS

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware

SAILTEC, INC CONGER COURT, OSHKOSH, WI USA

Avai 193 Fall 2016 Laboratory Greensheet

GOLFER. The Golf Putting Robot

Coriolis Mass Flow Meter

Fabry Perot / PDV Comparison. May 24, 2007

Collimation of Newtonian Telescopes

Experimental Investigation of the Aerodynamics of a Modeled Dragonfly Wing Section

Dillon Thorse Flow Visualization MCEN 4047 Team Poject 1 March 14th, 2013

Flow in a shock tube

Lesson: Airspeed Control

Related Rates - Classwork

SEMATECH Provisional Test Method for Pressure Cycle Testing Filter Cartridges Used in UPW Distribution Systems

INSTRUCTION MANUAL. January 23, 2003, Revision 0

ABS. Acoustic Bubble Spectrometer. Measurement of Bubble Size, Bubble Number & Void Fraction DYNAFLOW, INC. Research & Development in Applied Sciences

NanoSight NS300. NanoSight NS300. Operation instructions. Laser Spectroscopy Labs, UCI

Digital Melting Point Apparatus

VORTEX SHEDDING AND VORTEX FORMATION FROM A PAIR OF IN-LINE FORCED OSCILLATING TANDEM ARRANGED CIRCULAR CYINDERS IN A UNIFORM FLOW

AERODYNAMIC CHARACTERISTICS OF SPIN PHENOMENON FOR DELTA WING

Laser-Induced Bubbles in Glycerol-Water Mixtures

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics July 2012 Malta

Outline Chapter 7 Waves

Ripple tank with LED light source. Ripple tank with LED light source, complete

Bottle Rocket Launcher P4-2000

Eliminating Sources of Error in IV Pump Testing

Ripple Tank with LED-light source, complete

Brief Maintenance Manual DAR-Solo

A comparison of NACA 0012 and NACA 0021 self-noise at low Reynolds number

AE Dept., KFUPM. Dr. Abdullah M. Al-Garni. Fuel Economy. Emissions Maximum Speed Acceleration Directional Stability Stability.

Three-dimensional Vortical Structures in the Wake of a Flexible Flapping Foil

New power in production logging

1. A tendency to roll or heel when turning (a known and typically constant disturbance) 2. Motion induced by surface waves of certain frequencies.

Attitude Instrument Flying and Aerodynamics

THE BRIDGE COLLAPSED IN NOVEMBER 1940 AFTER 4 MONTHS OF ITS OPENING TO TRAFFIC!

The Discussion of this exercise covers the following points:

Evaluation of High Lift System with Oscillatory Blowing in 2.5D Configuration

EFFECT OF CORNER CUTOFFS ON FLOW CHARACTERISTICS AROUND A SQUARE CYLINDER

OUS31. Technical Information

COLD WELD COPPER TUBE SAMPLING EQUIPMENT AND PROCEDURES

Any laboratory is equipped with specific tools, equipment,

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

Flight Dynamics II (Stability) Prof. Nandan Kumar Sinha Department of Aerospace Engineering Indian Institute of Technology, Madras

BIOPAC Blood Flow Monitor

SPECIFICATIONS PARTICLE SENSOR KS-18F Higashimotomachi, Kokubunji, Tokyo , Japan

TS1. Ultrasonic Tank Sender. Installation and Operating Instructions. For TS1 Firmware v3.8. Page 1 INST-TS1-V13 18/11/10

USER'S GUIDE. Nanoflow Probe. Red Stripe. 3-4mm. ptfe Sleeve. To Injector. ZU1XC Fused Silica TTF115. Fused Silica. ptfe Sleeve

Sound scattering by hydrodynamic wakes of sea animals

Vibration isolation system 1VIS10W. User manual

i-clicker Discussion Question

LASER INDUCED FLUORESCENCE MEASUREMENTS OF CARBON DIOXIDE DISSOLUTION IN WAVE-BREAKING TURBULENCE

Pump Performance Testing

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas

TITLE: DNA minitube - Red

Review of. Bell B206 Replica Torque Pedals. Manufactured by OE-XAM

Login to ilab Kiosk. Revised 05/22/2018. Load your sample:

Group Project Flume Airfoil Flow

Lesson: Pitch Trim. Materials / Equipment Publications o Flight Training Manual for Gliders (Holtz) Lesson 4.4 Using the Trim Control.

PROCESS MONITORING AND CONTROL

Installation Effects on Ultrasonic Flow Meters for Liquids. Jan Drenthen - Krohne

Improvement of an Artificial Stall Warning System for Sailplanes

Vortex flowmeters. Product family introduction Principle of operation Product review Applications Key product features

Agilent ICP-MS Interactive Troubleshooting tool for Plasma ignition problem

Standard Operating Procedure for Zooplankton Sample Collection and Preservation

Anemometry. Anemometry. Wind Conventions and Characteristics. Anemometry. Wind Variability. Anemometry. Function of an anemometer:

Methods The experiments were carried out in the wind tunnel in the Air physics laboratory at the Engineering Centre Bygholm as shown in figure 1.

Transcription:

Introduction to AAE520 Forebody/LDV Lab Learn to use a water tunnel Learn about the laser doppler velocimeter (LDV), use it for some measurements Learn about flow visualization Learn about subsonic forebodies at high angle of attack

Introduction to Water Tunnels Air and water are both Newtonian fluids. Water sometimes used to simulate air. Hydrodynamics is also important for ships, torpedos, etc. Flow visualization is easy in water tunnels LDV is easy in water tunnels particles are ubiquitous Water leaks cause a lot more trouble than air leaks Water often hastens corrosion Surface waves can cause problems

Introduction to ASL Water Tunnel Obtained surplus from Boeing ca. summer 2002 Installed, wired, plumbed, fixed in 2002-2003. Motor and controller replaced in 2005-2006. Traverse improved in 2006. AAE520 Spring 2004 was first real use Goes up to 1 foot/second, fairly slow 15x20-inch test section is good sized Nice dye system. Tunnel built for flow viz. Presently not covering test section, will get surface waves

Water Tunnel Operations Read the manual summary If turn off, wait til motor stops before restart Potentiometer on operations panel controls speed Flowmeter supposedly calibrated to show test section speed Don t go above 12 inch/sec, pump will cavitate and may be damaged if left that way for long Leave filter off (and unpressurized) to retain particles for LDV.

Water Tunnel Operations, 2 We may need to clear air from the honeycomb (see p. 18 of manual). But usually not. Dye colors the water. Bleach (not too much) reduces color, also controls algae growth, but more trouble than it s worth for us. Limit dye usage, will need to replace water anyway Draining takes about 25 mins. Filling takes about 1/2 hour when no one else is using the water. (New automated fill line and new drain line). Keep water away from electrical/electronic apparatus! Don t rely on the GFI!

Water Tunnel/Cone Operations, 3 Don t get the water too blue, doing flow viz! There s no time in the schedule for changing the water, which takes about an hour during which someone must be around. Dilute dye! About 1 part dye: 10 parts water. Plan for a drain-&-fill between groups start drain when finished, so morning group loses 1/2 hour and afternoon group also loses 1/2 hour. Look at vortices with dye. Can vary: 1) tunnel speed, 2) cone AOA, 3) cone roll angle, 4) cone height in tunnel, 5) axial location of cone support (is this worth it?) 6) spanwise location of cone (does this matter?), 7) dye injection parameters (dye density, pressure, flow rates). Take photos.

Water Tunnel/Cone Operations, 4 Always use 2 people to adjust the cone, one to hold the cone and the other to tighten the screws, one on each side of the tunnel. A safety precaution so the cone doesn t slip while you tighten. Measure cone angles with inclinometer. Watch out for the LDV rig when you move the cone.

Water Tunnel/Cone Operations, 5 Can release the air bubbles from dye reservoir inside cone by removing tube from the back of the cone while cone is in the water. Please tilt the cone out of the water at the end of the day to let it dry. This minimizes corrosion in the aluminum. Aluminum will corrode if in constant contact with water.

Laser Doppler Velocimeter See notes on website, followup lecture, section by Ron Adrian in Fluid Mechanics Measurements Most common optical technique for measuring velocity. Several vendors sell off-the-shelf systems Nonintrusive operations. Requires particles Forward scattering operation, as here, enables use of lower cost ($2K) and relatively safe laser Keep the laser beam out of your eyes! And those of others!

Laser Doppler Velocimeter, 2 Our first real experience with LDV Sullivan built a laser and an LDV for his Ph.D. thesis Present setup adapted from 333L demo. by Collicott No automated doppler processor, sample photodiode signal with digital scope and process doppler bursts in your own software or with FFT averaging

Sketch of LDV Apparatus Used in 520 & 333L Developed by Prof. Collicott. For 520, split transmitting and receiving optics, place water tunnel test section in between, in place of item 12. Lens 1 For 520, drop mirrors 1 and 2

Magnified Image of LDV Probe Volume Note Interference Fringes Particles traverse fringes in flow, scatter light at a frequency proportional to their axial speed. First-surface mirror placed before test section, deflect beam into DISA microscope objective at beam intersection, project on cardboard card. 8 Feb. 2006 SPS.

Sample Output from LDV at 4.5 in./sec LDV output reading from scope at 4.5 inches/sec. in water tunnel, 20 Feb. 2004 Fairly typical to good particle doppler shift. Upper signal from photodiode direct, lower signal is highpass filtered at about 4 khz to show doppler burst better.

Sample Output from LDV at 9 in/sec. LDV output reading from scope at 9.0 inches/sec. in water tunnel, 20 Feb. 2004 Upper signal from photodiode direct, lower signal is highpass filtered at about 4 khz to show doppler burst better. Double the frequency at 4.5 in/sec (note scale!)

More on Laser Doppler Velocimeter Most groups have been able to get data, although sometimes the doppler bursts are not great Alignment is tricky (and we are still learning about how to do it). LDV drifts in and out of alignment from day to day. Sullivan says it will drift as you traverse and image through different parts of the window Some groups had little or nothing, first week in 2004. But it nearly always works well enough to get data. Save multiple particle-doppler velocity data at a given location. What is the probability distribution (histogram)? The rms and mean? Look at the statistics. Look at the effects of processing methods.

More on Laser Doppler Velocimeter For week 1, leave the probe volume in the middle of the tunnel, run the speed up and down, and check the LDV speed against the flowmeter speed. For week 2, we will be a little more aggressive in using the LDV. Suggest you move the traverse to put the probe volume at various locations in the wake, try to do a wake profile. As of 2006, the traverse can move the LDV probe volume through most of the water tunnel test section. You can move the LDV table and probe volume in 3D, using the hand cranks. Don t move the heavy cart itself. Be careful moving the table around, don t ram the optics into anything. Don t move too much in week 1. If optics go out of alignment, move back. AAE520 S.P. Schneider 23-Jan-17

Aligning the Laser Doppler Velocimeter Source optics must be carefully aligned to keep beams coplanar and put the intersection and focus where you want the probe volume. Beams must be collimated before first lens Beams then intersect again and focus on the pinhole. Pinhole must be exactly at the focus, so both beams go through it. Then when the iris blocks the main beams, the pinhole is at the focus of the light scattered from the beam intersection. Need to see not only blips with light scattered from particles, but blips with wiggles showing doppler-shift light scattered from particles. Blips w/o wiggles are from particles that aren t in the probe volume

Studying the Laser Doppler Velocimeter Receiving optics covered to block 633 nm from the lights Transmitting optics are tricky to align So probably should not have students adjusting either right now. What can you do? Look at the signals Measure the included angle of the beam, for computing the particle speed from the doppler frequency. Block one beam at a time, look at the result

Laser Doppler Velocimeter, 3 Leave the laser on all day, turn it off at the end of the day. But turn the lever that blocks the beam, when you aren t using it, to improve safety. LDV is set up as an instrument to study and make a few measurements, not as a production instrument. Look at the doppler bursts (not always easy to get, the alignment is very sensitive, ask for help if you get nothing), see how the instrument works, get particle velocities from the doppler bursts you can save. Leave the water filter off! We need some big particles to scatter light for the LDV.

Flow Visualization Dye bled from cone into water Streaklines, streamlines, pathlines Can vary the flow rate of dye and the air pressure pushing the dye Too much dye will disturb the flow, color the tunnel water too rapidly Look for wake vortices, detachment positions, etc. See Bridges papers for some discussion, AIAA 93-2960 and AIAA 92-0406.

Forebodies at Angle of Attack Subsonic forebodies at AOA shed vortices, like cylinder in crossflow. Vortices may remain attached at LE if AOA not too high Vortices cause asymmetric lift. Vortex lift critical to high AOA maneuvers. Asymmetric vortices can cause side forces that can be hard to control Nose vortices impinging on F-18 vertical stabilizer causes structural problems An important issue for high AOA aerodynamics See for example, Bridges et al., AIAA Papers 93-2960 and 92-0406.

Suggestions for Lab Operations No procedures to hand out, except for manuals Study tunnel and instrumentation Vary tunnel speed, model position, model AOA Study wake vortices with dye. Record photographs with digital camera Do try to finish all your dye flow visualization in Week 1, so we don t have to drain and fill the tunnel in Week 2. Study empty-tunnel mean flow with LDV Study wake with LDV. Some vertical and horizontal traversing is easy. If you traverse too far, the LDV may go out of alignment, if so it should come back when you traverse back. AAE520 S.P. Schneider 23-Jan-17