SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

Similar documents
AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

OPERATOR S MANUAL

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP

OWNER S TECHNICAL MANUAL

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

ACCU-PULSE Installation and Operation Instructions

Binks SV100 Conventional Suction Feed Spray Gun

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

Air Consumption Recommended Usage Siphon Feed

Pressure Regulators. Operating Instructions. Instrumentation

Portable Oil Lube Air Compressors

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

Guide for Evaluating Your Hose Assembly Supplier

INSTRUCTIONS PARTS LIST

Advanced Fluid Handling Cart Owner s Manual

Model PSI Compressor with 3-Gallon Air Tank 12VDC

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

T1-Titanium HVLP Siphon Feed Spray Gun

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

NORMAL OPERATING PROCEDURES Operating Parameter Information

Air Operated Hydraulic Pumping Systems to 50,000 psi

Bobtail DOT 407 / 412 Vacuum

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

OPERATION MANUAL NTF-15

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING

G92 Series BASOTROL Automatic Pilot Gas Valve

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

36H SERIES Combination Gas Valve

Installation Instructions and valve Maintenance Rev. 0 of 29/09/15

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

MEGR-1912 Instruction Manual

Operator: Save these instructions for future use!

1/2 in. AIR IMPACT WRENCH (TWIN HAMMER)

TECHNICAL DATA. Q= Cv S

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

OPERATION MANUAL NTF-60 Plus

Binks Model 21 (Brass Body) Automatic Spray Gun General Arrangement Diagram and Hook-Up. Side Port Control. Fluid. Cylinder Air Fluid.

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

Installation and User Manual

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Cal/OSHA T8 CCR 1536 Cal/OSHA T8 CCR 4799 Cal/OSHA T8 CCR 4845 Cal/OSHA T8 CCR 4848

G96 Series BASOTROL Dual Operator Valve

OPERATION / 3Z9305G 1:1 RATIO TRITON / Spray Packages / / / List of Models, page 2 / / / 100 psi (7 bar, 0.7 MPa) Maximum Working Pressure

Noth American 7347 High Pressure Gas Regulators

Types 749B and R130 Changeover Manifolds

WARNING: FOR OUTDOOR USE ONLY

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

Safety Powder Spray Systems

Model Series 62 Constant Differential Relay

FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

200 PSI COMPRESSORS - MODEL NUMBERS

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

COATINGS SPRAY GUIDE Urethane 520

INTENDED USE TECHNICAL SPECIFICATIONS

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

100C Air Compressor Kit

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

Constant Pressure Crude Oil Container Model CPCCP

General Precautions for handling compressed gases

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

WARNING: Installation Instructions. Natural Gas High Altitude Conversion Kit United States Installations Only

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

PC 1010 Electric Air Compressor

T1-Titanium HVLP Pressure Feed Spray Gun

Installation Instructions and valve Maintenance Rev. 0 of 21/09/15

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

North American 7339 High Pressure Gas Regulators

ROUGHNECK II Pumpless Drain

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1

Installation Operation Maintenance

Mooney * Noise Controller Installation, Operation, and Maintenance Manual

GUIDELINES FOR CONDUCTING HYDROGENATION REACTIONS

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

CITY AND COUNTY OF DENVER CR&CF RISK UNIT Compressed Gas Safety Standard

BGA158, BGA171 and BGA110 Series Shutoff Gas Valve

TECHNICAL DATA. than the water inlet pressure to the concentrate

Vision Painting Inc Safety Management System

DeVILBISS AIR POWER COMPANY. OWNERS MANUAL FOR PERMANENTLY LUBRICATED AIR COMPRESSOR (For Home Use Only) MODEL NO. DFAC153 SPECIFICATION CHART

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

Right-Angle Tube Roller Model

Natural Gas High-Altitude Conversion Kit For Installations in the United States (2,001 10,000 Feet)

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS

Operating Manual. Model BAC-30RT30/BAC-30DC

Full Internal Relief Valves Instruction Manual

User Manual. Quantos Automated Dosing Liquid Module

Transcription:

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER SUPPLIMENT TO eom IMPORTANT READ THIS MANUAL BEFORE PRODUCT INSTALLATION, OPERATION, INSPECTION & MAINTENANCE Tougher and more rigid guidelines are being established daily for safety in the workplace. To this end, specific Neoflux pumps are manufactured for the chemical, petrochemical, and petroleum industries to meet the safety requirements. Specific aluminum and stainless steel, alloy-fitted pumps assembled with Teflon or Buna elastomers for use in transferring volatile liquid. Petroleum product dispensing systems should be limit to 3.4 bar (50 psig) air supply pressure and 3.4 bar (50 psig) discharge pressure. In addition, pumping temperatures must be within the range of -20ºF to +125ºF (- 29ºC to 52ºC). Pump exhaust to be connected to pipe or tubing to be routed outdoors or other location determined to be equivalent. All pipe & connections must be of Gasoline Resistance Compound Pump should be fitted with a pressure relief valve rated to a maximum of 3.4 bar (50 psig). This valve should be connected to the pump discharge line to vent pressure resulting from thermal expansion. The pressure relief valve should incorporate a return line back to the supply tank. Pump must be electrically grounded. The ground connection is marked with a tag having the grounding symbol. Page 1 of 6

FIRE AND EXPLOSION PREVENTION USE OF PRODUCTS IN EXPLOSION ZONES There is a risk of fire and/or explosion if certain conditions exist. These conditions include, but are not limited to, the following: Pumping flammable fluids (in some cases an additional risk may be created by vapors or gases resulting when the process fluid escapes by leaking, component failure, or improper maintenance.) Product used in flammable atmospheres (flammable atmospheres can be caused by the presence of gases, dusts, or vapors) Placement of flammable materials near product Product powered by flammable gases (Example: Natural gas or air/flammable compressor oil mixture) Standard Neoflux pump models should not be powered by flammable gases. Consult factory for specific models intended to be powered by flammable gases. Be aware of the hazards associated with the specific application and the application environment. Conform to all applicable laws, regulations and codes. Do not use the product if there is any doubt about the safety of the application. Mechanical operation and flowing fluids can generate static electricity. Groundable products are required for all potentially flammable or explosive applications to prevent static spark. The pump, piping, valves, containers and other equipment must be grounded. Periodic inspection of the ground connection should be performed to ensure the equipment is properly grounded. The surface temperature of the equipment must be kept below the ignition temperature of any potential explosive atmosphere. The surface temperature is affected by the temperature of the fluid being pumped and the kinetic energy added by the pump and application (e.g. recirculation of process media). The end user must ensure process media and equipment maximum temperature is acceptable for the environment. Electrical products have special considerations when used in explosive environments. Ensure electrical products possess the correct rating for the intended application. Page 2 of 6

READ, UNDERSTAND & FOLLOW THIS INFORMATION TO AVOID INJURY & PROPERTY DAMAGE 1. Excessive Air Pressure: Can cause personal injury, pump damage or property damage. Do not exceed MAX. Air Inlet Pressure of 3.5 BAR (50 PSIG) as per U.L. 79 Specifications. Please make sure that the material of the hose & other components are able to with stand fluid pressures develop by this pump. Check all hoses for damage or wear. Be certain dispensing device is clean & in proper working conditions. 2. Excessive Discharge Pressure: Can result into personal injury or property damage. Do not service or clean pump, hoses or dispensing valve while the system is pressurized. Dis-connect air supply line & relieve pressure from the system by opening dispensing valve or device & / or carefully & slowly loosening & removing outlet hose or piping form pump. 3. Static Spark: Can cause explosion resulting in severe injury or death. Ground Pump & Pumping System. Sparks can ignite flammable material & vapors. The pumping system & the object being sprayed must be grounded when it is pumping, flushing, re-circulating or spraying flammable material such as Paints, Solvents, Lacquers etc. or used in location where surrounding atmosphere is conductive to spontaneous combustion. Ground the dispensing valve or device, containers, hoses & any object to which material is being pumped. Use the pump grounding screw terminal provided. Use Neoflux Ground Kit or suitable ground wire (12 ga. min.) to a good earth ground source. Secure pump, connections & all contact points to avoid vibration & generation of contact & static spark. Consult local building codes & electric codes for specific grounding requirements. After grounding, periodically verify continuity of electric path to ground. Test with an ohmmeter from each component (e.g. Hose, Pump, Clamps, Containers, Spray Gun etc.) to ground to insure continuity. Ohmmeter should show 0.1 ohms or less. Submerse the outlet hose end, dispensing valve or device in the material being dispensed if possible. (Avoid free streaming of material being dispensed) Use hoses incorporating a static wire. Page 3 of 6 Use proper ventilation.

Keep inflammables away from heat, open flames & sparks. Keep container closed when not is use. 4. Hazardous Material: Can cause serious injury or property damage. Do not attempt to return a pump to the factory or service center that contains hazardous material. Safe handling practices must comply with local & national laws & safety code requirements. Obtain MSDS from on all materials from the supplier for proper handling instructions. 5. Explosion Hazard: Models containing aluminum wetted parts cannot be used with III.-Trichloroethane, Methylene Chloride or other Halogenated Hydrocarbon Solvents which may react & explode. Check pump Air-Motor Section (Center Block), Fluid Caps, Manifolds & all wetted parts to assure compatibility before using with solvents of this type. 6. Exhaust Hazard: Pump exhaust may contain containments. Can cause severe injury. Pipe exhaust away from work area & personnel. (See Diagram at the end for further details) In the event of Diaphragm Rapture, material can be forced out of the air exhaust muffler. Pipe the exhaust to a safe remote location when pumping hazardous or inflammable material. (See Diagram at the end for further details) Use a grounded 3/8 minimum I.D. hose between the pump & the muffler OPERATING INSTRUCTIONS Neoflux Fuel-Transfer AODD Pump should never be operated at pressure exceeding 50 p.s.i (3.4 BAR) Air Inlet Pressure. This pump is equipped with a pressure relief valve on the Discharge Manifold which will open at 40 ± 4 p.s.i (2.75 BAR) to relieve pressure increases in the outlet hoses / plumbing caused by thermal expansion or other external force. Dis-connect the Air Supply from the pump if it is to be inactive for a few hours. Page 4 of 6

AIR & LUBE REQUIREMENT The Air-Supply line or hose to the pump should be adequately sized to carry sufficient volume of air to the pump. The Flow Rate / Fluid Volume is governed not only by Air Supply but also by the Air Volume available in the inlet (CFM). Air Supply should be filtered to provide clean dry air. A filter capable of filtering out particles larger than 50µ should be used on the air supply. The material inlet / outlet supply hose should not be too small or restrictive which will inhibit material flow. All Neoflux Pump Air-Distribution System is Lube-Free. No lubrication required other than O-ring lubricant which is applied during assembly /repairs. INSTALLATION A fluid return hose which is compatible with the fluid being pumped must be installed to the relief valve on the outlet manifold to return fluid back to the supply tank or pump inlet. The pump must be grounded to prevent static discharge. Grounding may be accomplished through the legs or to the ground lug provided on the pump Please notice that the material suction & discharge manifolds can be removed & rotated 180 to facilitate various mounting application. When this AODD pump is used in a force-feed situation, it is recommended that a check valve be installed at the air inlet to keep material out of air line in prevent of diaphragm failure. Secure AODD pump legs to a suitable surface to insure against damage by excessive vibration. Page 5 of 6