Standard Operating Manual

Similar documents
Standard Operating Manual

Standard Operating Manual

Standard Operating Manual

Standard Operating Manual

Standard Operating Manual

Standard Operating Manual

ABM MASK ALIGNERS. NanoFab 26 March 2009 A Micro Machining & Nanofabrication Facility

Usage Policies Notebook for NanoFurnace Furnace (EasyTube 3000 System)

University of MN, Minnesota Nano Center Standard Operating Procedure

Operating Procedures for Metal Evaporator I

Approved by Principal Investigator Date: Approved by Super User: Date:

OPERATION MANUAL NTF-15

Standard Operating Manual

University of Minnesota Nano Center Standard Operating Procedure

COBILT CA-800 Mask Aligner Equipment Operation

KARL SUSS MJB3 UV400 Mask Aligner Standard Operating Procedure

KARL SUSS MJB3 MASK ALIGNER STANDARD OPERATING PROCEDURE

OPERATION MANUAL NTF-60 Plus

Smooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV

Title: Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator

JETFIRST 150 RTA SYSTEM OPERATING MANUAL Version: 2 Feb 2012

Approved by Principal Investigator Date: Approved by Super User: Date:

Usage Policies Notebook for Parylene Coating System

Usage Policies Notebook for Xenon Difluoride (XeF 2 ) Isotropic Si Etch

Smooth Vent Valve XVD. Series

MJB4 Mask Aligner Operating Procedure. Effective Date: 07/12/2012 Author(s): Jiong Hua Phone:

Inert Air (N2) Systems Manual

Smooth Vent Valve. XVD Series

VACUUM REGULATORS CONTENTS

Nordiko Metal Sputtering System Standard Operating Procedure

Norton Group Toepler Pump Operating Instructions. Version 3.1

Title: Xactix XeF2 Etcher Semiconductor & Microsystems Fabrication Laboratory Revision: A Rev Date: 03/23/2016

Service Call: Vacuum Prevention System Testing on Category A and B Aerial Devices. Tools Required: 1. Atmospheric Vent Test Set (P/N )

product manual HM-4140, HM-4150, HM-4160 HM-4160A HM-4150 Humboldt FlexPanels

Arizona State University Center for Solid State Electronics Research Issue: E Title: Heat Pulse 610 Operating Procedure Page 1 of 7

High-Pressure Boiler Inspection Procedures: A Complete Checklist

Usage Policies Notebook for Thermco Atmospheric Diffusion Furnace system

Basic & Controlled Atmosphere Glove Boxes

Standard Operating Manual

Usage Policies Notebook for Trion RIE / ICP Dry Etch

SOP for Karl Suss MJB3 #1 Mask Aligner

STANDARD OPERATING PROCEDURES

5.1.3 Mechanical Hazards Drive assemblies have sufficient power to cause injury. Keep hands, fingers, clothing and tools clear of moving parts.

Warnings: Notes: Revised: October 5, 2015

Nanofabrication Facility: PECVD SOP Rev. 00, April 24

Equipment Operating Procedure Glove Box

Exhibit 4. Determination of Static Pressure Performance of the Healy Clean Air Separator (Executive Orders VR-201-N and VR-202-N)

Instruction Manual Updated 7/26/2011 Ver. 2.2

Issue: H Title: CHA E-Beam Evaporator Page 1 of 7. Table of Contents

THERMAL EVAPORATION UNIT (for Al evaporation)

WIKA INSTRUMENT CORPORATION

School of Chemistry SOP For Operation Of Glove Boxes

Pressure Regulators. Operating Instructions. Instrumentation

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH PNEUMATIC RELEASE

Thermcraft Tube Furnace General Use

Revised: June 7, 2017

R I T. Title: Amray 1830 SEM Semiconductor & Microsystems Fabrication Laboratory Revision: A Rev Date: 09/29/03 1 SCOPE 2 REFERENCE DOCUMENTS

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

Trion PECVD SOP IMPORTANT: NO PLASTIC, TAPE, RESISTS, OR THERMAL PASTE ARE ALLOWED IN THE CHAMBER

Warnings: Notes: Revised: January 8,

Usage Policies Notebook for STS DRIE System

Oerlikon Sputtering Evaporator SOP

Portable Oil Lube Air Compressors

OPERATING AND MAINTENANCE MANUAL

TABLE OF CONTENTS SAFETY FIRST!...3 BASIC OPERATION...4 ADJUSTMENTS...5. Cocking Pressure...5. Three-Way Valve Adjustment...6

Ambient Weather GL150-B Nautical Barometer User Manual

Plasma Cleaner. Yamato Scientific America. Contents. Innovating Science for Over 125 Years. Gas Plasma Dry Cleaner PDC200/210/510 PDC610G.

Inspection and Approval of Asphalt Mix Design Laboratories

RG6000. Refrigerant Recovery Machine. Operating Manual. 99 Washington Street Melrose, MA Phone Toll Free

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

SPUTTER STATION STANDARD OPERATING PROCEDURE

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

OAI Model 200 Tabletop Mask Aligner Portland State University

Operating Instructions

Leak Checking Large Vacuum Chambers

Karl Suss MJB4 Mask Aligner

ACCU-PULSE Installation and Operation Instructions

The Discussion of this exercise covers the following points:

RADIATION PROCEDURES MANUAL Procedure Cover Sheet

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

2 Switching off ECRIS 3. 4 Acquire Beam Spectrum 4. 6 Vent Instrument Chamber 5. 7 Pump down Chamber 5. 8 Baking out Chamber 5.

Workhorse-15 Oxygen Generator

Birck Nanotechnology Center

Model 10E Enviro-Line Environmental Pressurization System Installation & Operation Manual

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

Product Information News

Quebec Quebec Tel : Fax : MSDS: Methane, Oxygen in Nitrogen Mixture PRODUCT INFORMATION

INSTALLATION & MAINTENANCE INSTRUCTION

Vortex Dual. Refrigerant Recovery Machine

Ambient Weather GL150-TH Nautical Thermometer Hygrometer (ComfortMeter) User Manual

PNEUMATIC PRESSURE CONTROLLERS

PXRF- Tracer Helium Flow Control System

TOPIC: KNOWLEDGE: K1.01 [2.5/2.7] An atmospheric pressure of 15.0 psia is equivalent to... A psig. B psig. C psig.

Approved by Principal Investigator Date: Approved by Super User: Date:

S & M Water Consultants

AIR CONDITIONING AND PRESSURIZATION CONTROLS AND INDICATORS

DEH Instructions. Three-Phase, Platform-Mounted Distribution Transformers

Rejuvenation Instructions

B. Assemble the Method-25 sample train with a heated probe/filter.

BASIC RULES OF USAGE, OLIS DSM-20 CD Management The instrument is currently managed by the Analytical Biophysics Core Facility.

Transcription:

Standard Operating Manual Fisher Scientific Isotemp TM Model 281A Vacuum Oven Version 1.1 Page 1 of 9

Contents 1. Picture and Location 2. Process Capabilities 2.1 Cleanliness Standard 2.2 Substrate Size 2.3 Oven Temperature 2.4 Control Sensitivity 2.5 Consistency 2.6 Vacuum Range 2.7 Vacuum Leak Rate 3. Contact List and How to Become a Qualified User 3.1 Emergency Response and Communications 3.2 Training to Become a Qualified User 4. Operating Procedures 4.1 System Description 4.2 Safety Warning 4.3 Operation Precautions and Rules 4.4 Initial Status Checks 4.5 Initial System Checks 4.6 Vacuum Oven Operation Procedure 4.6.1 Operation in a Static Environment 4.6.2 Operation in a Nitrogen Environment 4.6.3 Operating in a Vacuum Environment 4.7 Clean Up 4.8 Check out Version 1.1 Page 2 of 9

Fisher Scientific Isotemp TM Model 281A Vacuum Oven 1. Picture and Location This tool is located at NFF Phase II Cleanroom Class 100. 2. Process Capabilities 2.1 Cleanliness Standard: Non Standard 2.2 Substrate Size: 10mm to 150mm 2.3 Oven Temperature: Ambient to 280 C 2.4 Control Sensitivity: +/- 1 C 2.5 Consistency: +/- 1 C (at ultimate vacuum) 2.6 Vacuum Range: Atmosphere to 30in.Hg (762mm) 2.7 Vacuum Leak Rate: <0.5in. Hg per 24 hours 3. Contact List and How to Become a Qualified User 3.1 Emergency Response and Communications 1. Security Control Center: 2358-8999 (24hr) & 2358-6565 (24hr) Version 1.1 Page 3 of 9

2. Safety Officer: Mr. Wing Leong CHUNG 2358-7211 & 64406238 3. Deputy Safety Officer: Mr. Man Wai LEE 2358-7900 & 9621-7708 4. NFF Senior Technician: Mr. Henry YEUNG 2358-7896 5. NFF Technician: Mr. Charles TANG 23587896 3.2 Training to Become a Qualified User Please follow the procedure below to become a Fisher Scientific Isotemp TM Model 281A Vacuum Oven qualified user. 1. Read through the on-line equipment operating manual of the equipment; http://www.nff.ust.hk/equipment-and-process/equipment-operation-manual.ht ml 2. Attend the equipment hand-on operation training either by peer or NFF staff. 3. If training is provided by NFF staff, user must log in NFF equipment reservation system, and register these trainings. 4. Send an e-mail to Mr. Henry YEUNG requesting Fisher Scientific Isotemp TM Model 281A Vacuum Oven. 5. Pass the examination for the equipment operation and security. 4. Operating Procedures 4.1 System Description Fisher Scientific Isotemp TM Model 281A Vacuum Oven is a multipurpose unit that operates under reduced pressure and/or inert atmosphere. The Vacuum Oven is equipped with a 0 to 300 C dial thermometer, which is graduated in 5 increments and mounted internally at the bottom of the oven chamber. The thermometer can be read through the observation window. Version 1.1 Page 4 of 9

Nitrogen/Air Selection Valve Thermometer Vent/Purge Valve Vacuum Gauge Heat Indicator Safety Lamp Power Switch Vacuum Valve Temperature control Power indicator Power Switch: Applies power to the oven temperature control. Temperature Control: Regulates the oven operating temperature. Heating Indicator: Indicates when the oven is being heated. Power Indicator: Indicates when the power switch in ON. Safety Lamp: illuminate when controlling temperature at approximately 5 above set point. Thermometer: 0-300 C dial thermometer with 2 divisions. Vacuum Gauge: Indicates chamber vacuum in inches of mercury. Vacuum Valve: Used for evacuating chamber, controlling vacuum. Vent/Purge Valve: Used for bleeding air or other gasses into chamber. Nitrogen/Air Selection Valve: Selects Nitrogen or air into chamber. 4.2 Safety Warnings 1. Follow NFF Health and Safety Manual. 2. Do not operate the unit at temperature above 280 C. 3. This is not an explosion proof oven. Do not place or use explosive, combustible, or flammable materials in the oven. 4. Resists may have irritating effects to eye, skin and mucous membranes! Observe and obey Material Safety Data Sheet (MSDS) of the corresponding materials Version 1.1 Page 5 of 9

used in the system! 5. Do not use sealed containers in the oven chamber. 6. Do not permit materials of any kind to rest on top of unit when operating at elevated temperatures and don t touch the top plate. 7. Do not touch the oven door particularly the glass portion, with unprotected hands when operating at high temperatures. 8. The unit must not become wet during operation or maintenance. 9. Always use hot hand to remove the processed substrates from the oven. 10. Always wear safety glasses and other appropriate protective equipment when operating this product. 11. According to the general fire emergency procedure of HKUST, please report the accident to the Security Control Center first. The nature of other emergencies will determine whether you will call police, staff, or both. If someone is injured, the 9-999 emergency number should be called before calling staff. If there is a facilities problem, such as a flood or a utility problem that does not present a danger to lab users but may result in damage to equipment, the staff or FMO need to be called. The 9-999 emergency should not be called for facility or equipment problem. Always call 9-999 when a potentially life threatening situation might exist (injury, fire, gas leak, etc.) 4.3 Operation Precautions and Rules 1. Please reserve the time slot on your own, and make sure you use your own time slot to do the exposure process. 2. Please check the checklist and fill all the details of the log sheet attached. 3. Do not operate the machine unless you are properly trained and approved by NFF staff. Version 1.1 Page 6 of 9

4.4 Initial Status Checks 1. Please check the status of shutdown notice posted in the NFF Notice Board. 2. Please check the reservation status on the website, and reserve the right time slot by your own. 3. Please check-in the equipment on your own according to the reserved time slot via card reader. 4.5 Initial System Checks 1. Verify proper function of vacuum. 2. Verify the Nitrogen available. 4.6 Vacuum Oven Operation Procedure 4.6.1 Operation in a Static Environment Static Environment refers to operation at atmospheric pressure and with air. 1. Place samples in the oven chamber then close the oven door. 2. Turn Power Switch to ON position. 3. Slowly rotate Temperature control dial clockwise unit heat indicator comes on. 4. Check the Table 1 of approximate temperature setting. Set the temperature of the oven using the manual temperature control knob to the number indicated for the desired temperature. Wait until the oven temperature stabilizes. The temperature can be read via the thermometer in the top center inside the oven. Version 1.1 Page 7 of 9

Table 1: Approximate Dial Settings in Static Air Dial Setting Temperature 2 25 C 4 55 C 6 85 C 8 115 C 10 145 C 12 180 C 14 210 C 16 240 C 18 275 C Table 2: Approximate Heat Up Times to Various Temperatures T Initial T Final Standard Accelerated 25 C 100 C 75 min. 35 min. 25 C 200 C 95 min. 75 min. 25 C 275 C 120 min. ------- 5. The heat up time is relatively slow. User can check approximate heat up times at Table 2. To speed up the oven heating rate, user can set the dial 2 setting above the desired temperature. Observe the thermometer. When the temperature will reach the desired temperature (i.e. less than 20 C), set the dial 2 settings lower. The oven can reach the final temperature quicker using this method. 6. After the baking time is up, set the Manual temperature control to 0, turn off the Power Switch. 7. After the temperature decrease to less than 100 C. Close the Vacuum Valve and open the purge/vent valve to vent the oven. Open the oven door and remove your sample. 8. Close the purge/vent valve and the door. Version 1.1 Page 8 of 9

4.6.2 Operation in a Nitrogen Environment 1. Place samples in the oven chamber then close the oven door. 2. Close the purge/vent control valve, switch Nitrogen/Air selection valve to Nitrogen. 3. Open the vacuum control valve to remove any air remaining in the chamber. 4. Close the vacuum control valve and slowly open the purge control valve to bleed as much N 2 as you wish. The pressure inside the oven will rise. 5. Close the purge control valve. 6. Repeat the step 3 to 5 several times. 7. Then follow the 4.6.1 step 2-8. 4.6.3 Operating in a Vacuum Environment 1. Place samples in the oven then close the oven door. 2. Close both the purge control and vacuum control valve. 3. Open the vacuum control valve (fully counter clockwise). 4. The vacuum, in inches of mercury, can be obtained from the vacuum gauge on the bottom of the oven. 5. Then follow the 4.6.1 step 2-8. 4.7 Clean Up 1. Clean the vacuum oven. 2. Make sure the Power Switch at OFF position. 4.8 Check Out 1. Check out the equipment via card reader immediately after use. 2. Fill in the details, problems or comments in the log sheet. Version 1.1 Page 9 of 9