Siemens AG psi (6 bar) 145 psi (10 bar) 464 psi (32 bar) 1450 psi (100 bar) 3626 psi (250 bar) 8700 psi (600 bar) psi (800 bar)

Similar documents
Pressure Measurement Transmitters for applications with advanced requirements (Advanced)

Siemens AG Span (min... max.) Max. perm. test. 87 psi (6 bar) 145 psi (10 bar) 464 psi (32 bar) 1450 psi (100 bar)

1 Technical specifications

Pressure Measurement Transmitters for applications with advanced requirements (Advanced)

Pressure Measurement Transmitters for applications with advanced requirements (Advanced)

1 Technical specifications

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

1 Technical specifications

SITRANS P measuring instruments for pressure

TYPE APPROVAL CERTIFICATE

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

Pressure Measurement. Transmitters for general requirements SITRANS P DS III Technical description. 2/74 Siemens FI

Pressure Measurement Single-range transmitters for general applications

1 Overview. Pressure Measurement Transmitters for general requirements. SITRANS P DS III - Technical description

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

Pressure Measurement Transmitters for applications with advanced requirements (Advanced)

Pressure Measurement Transmitters for applications with advanced requirements (Advanced)

Pressure Measurement Single-range transmitters for general applications

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

Pressure Measurement Single-range transmitters for general applications

Torque Tube TB300 Digital Transmitters

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2.

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications

Differential pressure

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

2600T Series Pressure Transmitter

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

Pressure transmitter PASCAL Ci4

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

SITRANS P measuring instruments for pressure

Multi Vision. Digital Transmitter 10/ EN

OPTIBAR P 1010 C Technical Datasheet

9700 Transmitter Submersible hydrostatic level transmitter

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

Technical Data. Dimensions

Siemens AG Transmitters with WirelessHART 1/42 SITRANS P280 for gauge and abs. pressure. Transmitters for food, pharmaceuticals

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

Technical Data. Dimensions

Technical Data. General specifications. Rated operating distance s n 5 mm

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

Model 261GR for gauge pressure Model 261AR for absolute pressure

Bourdon tube pressure gauge for diaphragm seals

Precision digital pressure gauge Model CPG1000

Differential Pressure Transmiter

Pressure Measurement Transmitters for food, pharmaceuticals and biotechnology

Precision pressure sensor Basic version Model CPT6020

Flow Measurement SITRANS F X

ATM.ECO/IS - Analog Transmitter with Temperature compensation

ATM.1ST/Ex - High Precision Transmitter

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Pressure switch with bourdon tube

Pressure Measurement. Transmitters for food, pharmaceuticals and biotechnology. SITRANS P300 for gauge and absolute pressure. 2/34 Siemens FI

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Technical Specifications

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

Pressure Switches Application Guideline

1 Overview. Pressure Measurement Transmitters for food, pharmaceuticals and biotechnology. SITRANS P300 for gauge and absolute pressure

Technical Data. Dimensions

RTX 1000H Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control. Features

C-Flow Coriolis Mass Flow Meters

Proportional pressure regulators VPPE

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm

ATM/Ex - Analog Pressure Transmitter

SSL. Smart Valve Positioner.

Model 266HSH Gauge Model 266NSH Absolute. 2600T Series Pressure Transmitters Engineered solutions for all applications

ED 701 Hygenic Pressure Transmitter

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E

Tapped exhaust port. Sturdy, simple, reliable design. Easy to add on Feedback. High gain pilot valve. Simple calibration, external zero adjustment

SITRANS P measuring instruments for pressure

ATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

High-performance submersible pressure transmitter For level measurement Model LH-10

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

SSR. Smart Valve Positioner.

3000 Series OPTIMASS Mass Flowmeter. Stainless Steel Hastelloy

EPP4 Pressure Regulator Basic G 1/4"

Mass Flow Meter (MFM) for gases

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

High-performance submersible pressure transmitter For level measurement Model LH-20

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >

High-performance submersible pressure transmitter For level measurement Model LH-10

Hand-held pressure calibrator with integrated pump Model CPH6600

Model 266MST Differential Model 266RST Absolute. 2600T Series Pressure Transmitters Engineered solutions for all applications

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Smart performance with innovative and ever-strong coil drive even under harsh working environments

Transcription:

Technical specifications SITRANS P, DS III series Input Measured variable Spans (infinitely adjustable) or nominal measuring range and max. permissible test pressure HART Gauge pressure Span (min.... max.) 0.5... 4.5 psi (0.0... bar) 0.58... 58 psi (0.04... 4 bar) 2.23... 232 psi (0.6... 6 bar) 9.4... 94 psi (0.6... 63 bar) 23.2... 2320 psi (.6... 60 bar) 58... 5802 psi (4.0... 400 bar) 02... 053 psi (7.0... 700 bar) Max. perm. test pressure 87 psi (6 bar) 45 psi (0 bar) 464 psi (32 bar) 450 psi (00 bar) 3626 psi (250 bar) 8700 psi (600 bar) 603 psi (800 bar) PROFIBUS PA and FOUNDATION Fieldbus Nominal measuring range 4.5 psi ( bar g) 58 psi (4 bar) 232 psi (6 bar) 94 psi (63 bar) 2320 psi (60 bar) 5802 psi (400 bar) 053 psi (700 bar) Max. perm. test pressure 87 psi (6 bar) 45 psi (0 bar) 464 psi (32 bar) 450 psi (00 bar) 3626 psi (250 bar) 8700 psi (600 bar) 603 psi (800 bar) Lower measuring limit Measuring cell with silicone oil filling 0.44 psi a (30 mbar a) Measuring cell with inert filling liquid 0.44 psi a (30 mbar a) Upper measuring limit 00 % of max. span (for oxygen version and inert filling liquid; max. 20 bar(740 psi)) Output Output signal 4... 20 ma Digital PROFIBUS PA and FOUNDATION Fieldbus signal Lower limit (infinitely adjustable) 3.55 ma, factory preset to 3.84 ma - Upper limit (infinitely adjustable) 23 ma, factory preset to 20.5 ma or optionally - set to 22.0 ma Load Without HART R B (U H - 0.5 V)/0.023 A in, - U H : Power supply in V With HART R B = 230... 500 (SIMATIC PDM) or - R B = 230... 00 (HART Communicator) Physical bus - IEC 658-2 Protection against polarity reversal Protected against short-circuit and polarity reversal. Each connection against the other with max. supply voltage. Electrical damping (step width 0. s) Set to 2 s (0... 00 s) Measuring accuracy Acc. to IEC 60770- Reference conditions (All error data refer always refer to the set span) Error in measurement at limit setting incl. hysteresis and reproducibility Increasing characteristic, start-of-scale value 0 bar, stainless steel seal diaphragm, silicone oil filling, room temperature 25 C (77 F)) r: Span ratio (r = max. span / set span) Linear characteristic 0.075 % -r 0 (0.0029 r + 0.07) % - 0 < r 30 (0.0045 r + 0.07) % -30<r 00 (0.005 r + 0.05) % Long-term stability (temperature change 30 C ( 54 F)) - to 4-bar measuring cell (0.25 r) % per 5 years 0.25 % per 5 years 6- to 700-bar measuring cell (0.25 r) % per 5 years 0.25 % per 5 years Influence of ambient temperature at -0... +60 C (4... 40 F) (0.08 r + 0.)% ) (at 700 bar: (0. r + 0.2)% 2) 0,3 % at -40... -0 C and +60... +85 C (0. r + 0.5) %/0 K 0.25 %/0 K (-40... +4 F and 40... 85 F) Measured Value Resolution - 3 0-5 of nominal measuring range /82 Siemens FI 0 204 US Edition

SITRANS P, DS III series Rated conditions Degree of protection (to IEC 60529) Temperature of medium Measuring cell with silicone oil filling Measuring cell with inert filling liquid In conjunction with dust explosion protection Ambient conditions Ambient temperature HART IP65 (optional IP65/IP68) -40... +00 C (-40... +22 F) -20... +00 C (-4... +22 F) -20... +60 C (-4... +40 F) - Transmitter -40... +85 C (-40... +85 F) - Digital indicator -30... +85 C (-22... +85 F) Storage temperature Climatic class -50... +85 C (-58... +85 F) PROFIBUS PA and FOUNDATION Fieldbus - Condensation Relative humidity 0... 00 % Condensation permissible, suitable for use in the tropics Electromagnetic Compatibility - Emitted interference and interference immunity Design Weight (without options) Acc. to IEC 6326 and NAMUR NE 2.5 kg ( 3.3 lb) Enclosure material Low-copper die-cast aluminum, GD-AlSi 2 or stainless steel precision casting, mat. no..4408 Wetted parts materials Connection shank Stainless steel, mat. no..4404/36l or Hastelloy C4, mat. no. 2.460 Oval flange Stainless steel, mat. no..4404/36l Seal diaphragm Stainless steel, mat. no..4404/36l or Hastelloy C276, mat. no. 2.489 Measuring cell filling Process connection Material of mounting bracket Steel Silicone oil or inert filling liquid (maximum value with oxigen measurement pressure 20 bar (740 psi) at 60 C (40 F)) Connection shank G½B to DIN EN 837-, female thread ½ -4 NPT or oval flange (PN 60 (MAWP 2320 psi)) to DIN 923 with mounting thread M0 or 7 / 6-20 UNF to IEC 658 Sheet-steel, Mat. No..0330, chrome-plated Stainless steel Sheet stainless steel, mat. no..430 (SS 304) Power supply U H Terminal voltage on transmitter 0.5... 45 V DC 0.5... 30 V DC in intrinsically-safe mode Separate 24 V power supply necessary - No Bus voltage Not Ex - 9... 32 V With intrinsically-safe operation - 9... 24 V Current consumption Basic current (max.) - 2.5 ma Start-up current basic current - Yes Max. current in event of fault - 5.5 ma Fault disconnection electronics (FDE) available - Yes Supplied through bus - Siemens FI 0 204 US Edition /83

SITRANS P, DS III series HART PROFIBUS PA and FOUNDATION Fieldbus Certificates and approvals Classification according to PED 97/23/EC For gases of fluid group and liquids of fluid group ; complies with requirements of article 3, paragraph 3 (sound engineering practice) Explosion protection Intrinsic safety "i" PTB 3 ATEX 2007 X - Marking Ex II /2 G Ex ia/ib IIC T4/T5/T6 Ga/Gb - Permissible ambient temperature -40... +85 C (-40... +85 F) temperature class T4; -40... +70 C (-40... +58 F) temperature class T5; -40... +60 C (-40... +40 F) temperature class T6 - Connection To certified intrinsically-safe circuits with peak values: U i = 30 V, I i = 00 ma, P i = 750 mw; R i =300 FISCO supply unit: U o = 7.5 V, I o = 380 ma, P o = 5.32 W Linear barrier: U o = 24 V, I o = 74 ma, P o = W - Effective internal inductance/capacitance L i = 0.4 mh, C i = 6 nf L i = 7 H, C i =. nf Explosion-proof "d" PTB 99 ATEX 60 - Marking Ex II /2 G Ex d IIC T4/T6 Gb - Permissible ambient temperature -40... +85 C (-40... +85 F) temperature class T4; -40... +60 C (-40... +40 F) temperature class T6 - Connection To circuits with values: U H =0.5...45 V DC To circuits with values: U H = 9... 32 V DC Dust explosion protection for zone 20 PTB 0 ATEX 2055 - Marking Ex II D IP65 T 20 C Ex II /2 D IP65 T 20 C - Permissible ambient temperature -40... +85 C (-40... +85 F) - Max. surface temperature 20 C (248 F) - Connection To certified intrinsically-safe circuits with peak values: U i = 30 V, I i = 00 ma, P i = 750 mw, R i = 300 FISCO supply unit: U o = 7.5 V, I o = 380 ma, P o = 5.32 W Linear barrier: U o = 24 V, I o = 250 ma, P o = W - Effective internal inductance/capacitance L i = 0.4 mh, C i = 6 nf L i = 7 H, C i =. nf Dust explosion protection for zone 2/22 PTB 0 ATEX 2055 - Marking Ex II 2 D IP65 T 20 C - Connection To circuits with values: U H =0.5...45VDC; P max =.2 W Type of protection "n" (zone 2) To circuits with values: U H = 9... 32 V DC; P max = W PTB 3 ATEX 2007 X - Marking Ex II 2/3 G Ex na II T4/T5/T6 Gc Ex II 2/3 G Ex ic IIC T4/T5/T6 Gc - Connection (Ex na) U m = 45 V U m = 32 V - Connections (Ex ic) To circuits with values: U i = 45 V FISCO supply unit ic: U o = 7.5 V, I o = 570 ma Linear barrier: U o = 32 V, I o = 32 ma, P o = W - Effective internal inductance/capacitance L i = 0.4 mh, C i = 6 nf L i = 7 H, C i =, nf Explosion protection acc. to FM Certificate of Compliance 3008490 - Identification (XP/DIP) or (IS); (NI) CL I, DIV, GP ABCD T4...T6; CL II, DIV, GP EFG; CL III; CL I, ZN 0/ AEx ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III Explosion protection to CSA Certificate of Compliance 5365 - Identification (XP/DIP) or (IS) CL I, DIV, GP ABCD T4...T6; CL II, DIV, GP EFG; CL III; Ex ia IIC T4...T6; CL I, DIV 2, GP ABCD T4...T6; CL II, DIV 2, GP FG; CL III ) Conversion of temperature error per 28 C. Valid for temperature range -3... +53 C < (0.064. r + 0.08) % / 28 C (50 F). 2) Conversion of temperature error per 28 C. Valid for temperature range -3... +53 C < (0.08. r + 0.6) % / 28 C (50 F). /84 Siemens FI 0 204 US Edition

HART communication HART 230... 00 Protocol HART Version 5.x Software for computer PROFIBUS PA communication Simultaneous communication with master class 2 (max.) The address can be set using Cyclic data usage Output byte Input byte Internal preprocessing Device profile Function blocks 2 Analog input - Adaptation to customerspecific process variables SIMATIC PDM 4 Configuration tool or local operation (standard setting address 26) 5 (one measured value) or 0 (two measured values) 0,, or 2 (register operating mode and reset function for metering) PROFIBUS PA Profile for Process Control Devices Version 3.0, Class B Yes, linearly rising or falling characteristic - Electrical damping, adjustable 0... 00 s - Simulation function Input /Output - Failure mode parameterizable (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively Register (totalizer) Can be reset, preset, optional direction of counting, simulation function of register output - Failure mode parameterizable (summation with last good value, continuous summation, summation with incorrect value) - Limit monitoring One upper and lower warning limit and one alarm limit respectively Physical block Transducer blocks 2 Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Characterizer Max. 30 points - Square-rooted characteristic Yes for flow measurement - Gradual volume suppression Parameterizable and implementation point of square-root extraction - Simulation function for measured pressure value and sensor temperature Constant value or over parameterizable ramp function FOUNDATION Fieldbus communication Function blocks 3 function blocks analog input, function block PID Analog input - Adaptation to customerspecific process variables characteristic Yes, linearly rising or falling - Electrical damping, adjustable 0... 00 s - Simulation function Output/input (can be locked within the device with a bridge) - Failure mode parameterizable (last good value, substitute value, incorrect value) - Limit monitoring Yes, one upper and lower warning limit and one alarm limit respectively - Square-rooted characteristic Yes for flow measurement PID Standard FOUNDATION Fieldbus function block Physical block resource block Transducer blocks transducer block Pressure with calibration, transducer block LCD Pressure transducer block - Can be calibrated by applying Yes two pressures - Monitoring of sensor limits Yes - Simulation function: Measured pressure value, sensor temperature and electronics temperature Constant value or over parameterizable ramp function Siemens FI 0 204 US Edition /85

Selection and Ordering data Article No. Pressure transmitter, with HART 7MF4033-7 7 7 7 7-7 7 7 7 Measuring cell filling Measuring cell cleaning Silicone oil normal Inert liquid ) Grease-free to cleanliness level 2 3 Measuring span (min.... max.) 0.5... 4.5 psi (0.0... bar) B 0.58... 58 psi (0.04... 4 bar) C 2.32... 232 psi (0.6... 6 bar) D 9.4... 94 psi (0.63... 63 bar) E 23.2... 2320 psi (.6... 60 bar) F 58.0... 5802 psi (4.0... 400 bar) G 02.0...053 psi (7.0... 700 bar) J F Wetted parts materials Seal diaphragm Process connection Stainless steel Stainless steel A Hastelloy Stainless steel B Hastelloy Hastelloy C Version as diaphragm seal 2)3)4) 5) Y Process connection Connection shank G½B to EN 837-0 Female thread ½-4 NPT Stainless steel oval flange with process connection (Oval flange has no female thread) - Mounting thread 7 / 6-20 UNF to IEC 658 2 - Mounting thread M0 to DIN 923 3 - Mounting thread M2 to DIN 923 4 Male thread M20 x.5 5 Male thread ½ -4 NPT 6 Non-wetted parts materials Housing made of die-cast aluminium 0 Housing stainless steel precision casting 6) 3 Version Standard versions International version, English label inscriptions, 2 documentation in 5 languages on CD (no order code selectable) Hazardous area rating General purpose A ATEX Hazardous approval - "Intrinsically safe (Ex ia)" B - "Explosion-proof (Exd)" 7) D - "Intrinsically safe and explosion-proof P (Ex ia + Ex d)" 8) - use in zone 2 9) E - "Intrinsically safe, explosion-proof enclosure R and dust explosion protection (Ex ia + Ex d + zone D/2D)" 8) FM + CSA Intrinsically Safe (is) F FM + CSA (is + ep) + Ex ia + Ex d (ATEX) S FM/CSA Hazardous approval - "Intrinsically Safe und explosion proof N C (is + xp)" 7) Electrical connection / cable entry Screwed gland Pg 3.5 (adapter) 0) A Screwed gland M20 x.5 B ½-4 NPT C Han 7D plug (plastic housing) incl. mating D connector 0) M2 connectors (stainless steel) 0) ) Selection and Ordering data Article No. Pressure transmitter, 7MF4033- with HART 7 7 7 7 7-7 7 7 7 Indicator Without indicator 0 Without indicator (digital display hidden, setting: ma) With indicator (digital display visible, setting: ma) 6 With indicator (digital display visible, setting as 7 specified, Order code "Y2"/"Y22" required) We can offer shorter delivery times for configurations identified as part of the Quick Ship Program. For details see page 9/5 in the appendix. Power supply units see Chap. 7 "Supplementary Components". Included in delivery of the device: Brief instructions (Leporello) CD-ROM with detailed documentation ) For oxygen cleaning application, add Order code E0. 2) When the manufacture s certificate (calibration certificate) has to be ordered for transmitters with diaphragm seals according to IEC 60770-2, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. 3) If the acceptance test certificate 3..is ordered for the transmitter with mounted diaphragm seals this certificate must also be ordered with the respective remote seals. 4) The diaphragm seal is to be specified with a separate order number and must be included with the transmitter order number, for example 7MF403.-..Y..-... and 7MF4900-...-.B 5) The standard measuring cell filling of configurations with remote seals (Y) is silicone oil. 6) Not in conjunction with Electrical connection "Screwed gland Pg 3.5" and "Han7D plug". 7) Without cable gland, with blanking plug 8) With enclosed cable gland EEx ia and blanking plug 9) Configurations with HAN and M2 connectors are only available in Ex ic. 0) Not in conjunction with types of protection "Explosion-proof" and "Ex na", "Intrinsic safety" and "Explosion-proof". ) M2 delivered without cable socket /86 Siemens FI 0 204 US Edition

Selection and Ordering data Pressure transmitter with PROFIBUS PA (PA) with FOUNDATION Fieldbus (FF) Article No. 7MF4034-7MF4035-7 7 7 7 7-7 7 7 7 Measuring cell filling Measuring cell cleaning Silicone oil normal Inert liquid ) Grease-free to cleanliness level 2 3 Nominal measuring range 4.5 psi ( bar) B 58 psi (4 bar) C 232 psi (6 bar) D 94 psi (63 bar) E 2320 psi (60 bar) F 5802 psi (400 bar) G 053 psi (700 bar) J Wetted parts materials Seal diaphragm Process connection Stainless steel Stainless steel A Hastelloy Stainless steel B Hastelloy Hastelloy C Version as diaphragm seal 2)3) 4) 5) Y Process connection Connection shank G½B to EN 837-0 Female thread ½-4 NPT Stainless steel oval flange with process connection (Oval flange has no female thread) 6) - Mounting thread 7 / 6-20 UNF to IEC 658 2 - Mounting thread M0 to DIN 923 3 - Mounting thread M2 to DIN 923 4 Male thread M20 x.5 5 Male thread ½ -4 NPT 6 Non-wetted parts materials Housing made of die-cast aluminium 0 Housing stainless steel precision casting 3 Version Standard versions International version, English label inscriptions, 2 documentation in 5 languages on CD (no order code selectable) Hazardous area rating General purpose A ATEX Hazardous approval - "Intrinsically safe (Ex ia)" B - "Explosion-proof (Exd)" 7) D - "Intrinsically safe and explosion-proof P (Ex ia + Ex d)" 8) - use in zone 2 9) E - "Intrinsically safe, explosion-proof enclosure R and dust explosion protection (Ex ia + Ex d + zone D/2D)" 8) (not for DS III FF) FM + CSA Intrinsically Safe (is) F FM + CSA (is + ep) + Ex ia + Ex d (ATEX) S FM/CSA Hazardous approval - "Intrinsically Safe und explosion proof N C (is + xp)" 7) Electrical connection / cable entry Screwed gland M20 x.5 B ½-4 NPT C M2 connectors (stainless steel) 0)) 2) F Selection and Ordering data Article No. Pressure transmitter with PROFIBUS PA (PA) 7MF4034- with FOUNDATION Fieldbus 7MF4035- (FF) 7 7 7 7 7-7 7 7 7 Indicator Without indicator 0 Without indicator(digital display hidden, setting: bar) With indicator (digital display visible, 6 setting: bar) With indicator (digital display visible, setting as 7 specified, Order code "Y2" required) Included in delivery of the device: Brief instructions (Leporello) CD-ROM with detailed documentation ) For oxygen cleaning application, add Order code E0. 2) When the manufacture s certificate (calibration certificate) has to be ordered for transmitters with diaphragm seals according to IEC 60770-2, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. 3) If the acceptance test certificate 3..is ordered for the transmitter with mounted diaphragm seals this certificate must also be ordered with the respective remote seals. 4) The diaphragm seal is to be specified with a separate order number and must be included with the transmitter order number, for example 7MF403.-..Y..-... and 7MF4900-...-.B 5) The standard measuring cell filling of configurations with remote seals (Y) is silicone oil. 6) M0 fastening thread: Max. span 60 bar (2320 psi) 7/6-20 UNF and M2 fastening thread: Max. span 400 bar (5802 psi) 7) Without cable gland, with blanking plug 8) With enclosed cable gland EEx ia and blanking plug 9) Configurations with HAN and M2 connectors are only available in Ex ic. 0) M2 delivered without cable socket ) Not available with protection type "Ex d bestellbar (Options D, P, N and R) 2) Not with protection types "Explosion-proof" and protection type Ex na, Intrinsic safe and Explosion proof. Siemens FI 0 204 US Edition /87

Selection and Ordering data Order code Further designs HART PA FF Add "-Z" to Article No. and specify Order Code. Pressure transmitter with mounting bracket ( x fixing angle, 2 x nut, 2 x U- washer or x bracket, 2 x nut, 2 x U- washer) made of: Steel A0 Stainless steel A02 plug Han 7D (metal, gray) A30 Han 8U (instead of Han 7D) A3 Angled A32 Cable sockets for M2 connectors A50 (stainless steel) Rating plate inscription (instead of German) English B French B2 Spanish B3 Italian B4 English rating plate B2 Pressure units in inh 2 0 and/or psi Factory calibration certificate ) C Material traceability certificate 2) C2 Factory certificate of conformance C4 "Functional safety SIL2" C20 Devices suitable for use according to IEC 6508 and IEC 65. Includes SIL conformity declaration "Functional safety" (PROFIsafe) C2 3) Certificate and PROFIsafe protocol "Functional safety SIL2/3" C23 Devices suitable for use according to IEC 6508 and IEC 65. Includes SIL conformity declaration Setting of upper limit of output signal to D05 22.0 ma Manufacturer's declaration acc. to NACE (MR 003-202 and MR 075-2009) D07 Degree of protection IP65/IP68 D2 (only for M20x.5 and ½-4 NPT) Brad Harrison Connector D40 Surge Protection J0 External, ½" NPT Use in or on zone D/2D E0 (only together with type of protection "Intrinsic safety" (transmitter 7MF4...-...-.B.. Ex ia) ) Oxygen application E0 (In the case of oxygen measurement and inert liquid max. 00 bar (450 psi) at 60 C (40 F)) CRN approval Canada E22 (Canadian Registration Number) Dual seal E24 Manifold Mounting assembled to Block & bleed valve (7MF90-4FA) Assembled to Block & bleed valve T03 (7MF90-4FA) ½-4 NPT male, PTFE packing and pressure test Two coats of lacquer on casing and G0 cover (PU on epoxy) Surge Protection J0 External, ½" NPT Selection and Ordering data Order code Additional data HART PA FF Please add "-Z" to Article No. and specify Order code(s) and plain text. Calibrated range Y0 4) Specify in plain text (max. 5 characters): Y0: X to Y psi, inh 2 0, fth 2 0... Tag number/identification Y5 (max. 6 characters), specify in plain text: Y5:... Tag description Y6 (max. 27 characters), specify in plain text: Y6:... Entry of HART (TAG) Y7 (max. 8 characters), specify in plain text: Y7:... Pressure units for digital display Y2 specify in plain text: Y2: psi, inh 2 0, fth 2 0... Non-Pressure units for digital display 5) Y22 + (measuring range in pressure units Y0 ("Y0"/"Y02") mandatory) specify in plain text: Y22: X to Y GPM, MGD, Feet... Preset bus address Y25 possible between and 26 Specify in plain text: Y25:... Damping adjustment in seconds Y30 (0... 00 s) Factory mounting of valve manifolds, see accessories. Only Y0, Y5, Y6, Y7, Y2, Y22, Y25 and D05 can be factory preset = available We can offer shorter delivery times for configurations identified as part of the Quick Ship Program. For details see page 9/5 in the appendix. Ordering example Item line: 7MF4033-EA00-AA7-Z B line: A0 + Y0 + Y2 C line: Y0: 45... 290 psi (0... 20 bar) C line: Y2: psi (bar) ) When the manufacture s certificate (calibration certificate) has to be ordered for transmitters with diaphragm seals according to IEC 60770-2, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here. 2) If the acceptance test certificate 3..is ordered for the transmitter with mounted diaphragm seals this certificate must also be ordered with the respective remote seals. 3) Profisafe transmitters can only be operated with the S7 F Systems V6. configuration software in combination with S7-400H. 4) Measuring accuracies for PROFIBUS PA transmitters with Option Y0 are calculated in the same way as for HART devices. 5) Preset values can only be changed over SIMATIC PDM. /88 Siemens FI 0 204 US Edition

Dimensional drawings 5 (0.6) 43 (5.6) 74 (2.9) 53 (2.) 54 (2.3) 27 (.) 24 (0.94) approx. 96 (3.78) 7 (0.67) 29 (.4) 4) 84 (3.3) 5 approx. 40 (.6) Ø80 (3.5) 7 (6.7) 9 SW 36 8 72 (2.8) 2 50 (.97) 7 (4.6) 68 (2.68) 3 4 20 (4.72) 3 6 7 76 (6.93) 237 (9.33) Space for rotation of housing min. 90 (3.54) 5) 23 (4.84) Ø50... 60 (.97... 2.36) 05 (4.3) 2 3 4 Electronic side, digital display (longer overall length for cover with window) ) Terminal side ) Electrical connection: Screwed gland Pg 3,5 (adapter)(adapter) 2) 3), Screwed gland M20 x,5 or Screwed gland ½-4 NPT or Han 7D/Han 8D 2) 3) plug Harting adapter 5 Protective cover over keys 6 Blanking plug 7 Screw cover - safety bracket (only for type of protection "Explosion-proof enclosure", not shown in the drawing) 8 Process connection: Connection shank G½B or Oval flange 9 Mounting bracket (option) ) Allow approx. 20 mm (0.79 inch) thread length to permit unscrewing 2) Not with type of protection "Explosion-proof enclosure" 3) Not with type of protection "FM + CSA" [IS + XP]" 4) For Pg 3,5 with adapter approx. 45 mm (.77 inch) 5) Minimum distance for rotating pressure transmitters, dimensions in mm (inch) Siemens FI 0 204 US Edition /89