SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Similar documents
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z CALIBRATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. PRECISION MEASURING CORP Groesbeck Hwy. Fraser, MI Robert Meyer Phone:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z TROXLER ELECTRONICS LABORATORIES, INC. James Pratt Phone:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Accredited Laboratory

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 ANSI/NCSL Z

Certificate of Accreditation

Certificate of Accreditation

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Certificate of Accreditation

Certificate of Accreditation

Certificate of Accreditation

Inspection and Acceptance of Asphalt Mix Design Laboratories

Supersedes: The copy of this document located on Measurement Canada s website is considered to be the controlled copy.

MET-101 Introduction to Metrology

Inspection and Approval of Asphalt Mix Design Laboratories

2014 Programme of Training Courses in Measurement & Calibration

GMC-I Service GmbH Calibration Center

TG GUIDELINES CONCERNING CALIBRATION INTERVALS AND RECALIBRATION

Specific Accreditation Criteria Calibration ISO IEC Annex. Mass and related quantities

K V A L I F I K. Our accreditation number: NAH /2015. Valid to:

Technical Procedure for Instrument Calibration and Maintenance

CALIBRATION CERTIFICATE # 500

DFX II Series. Digital Force Gauge

GUIDANCE FOR THE APPLICATION OF EQUIPMENT CALIBRATION AND TRACEABILITY OF MEASUREMENTS ON INSPECTION BODIES

Certified Accuracy. Ring Force Gauge. Models and Capacities Available. Design and Principle of Operation

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF PRESSURE METROLOGY

KENYA ACCREDITATION SERVICE

FPG8601 Force Balanced Piston Gauge

DENSITY CALIBRATIONS AT MIKES. Heikki Kajastie, Jorma Manninen and Kari Riski Centre for Metrology and Accreditation (MIKES) ABSTRACT

Pressure is our Business

B ADDENDUM # 1

UKAS Accredited Electrical & Mechanical Calibration Services (Laboratory and On-site)

MTS Restan. Automatic System for Residual Stress Measurement by Hole-Drilling

Elcometer ISO Groove Depth Checker. Operating Instructions

CALIBRATION SERVICES HUMIDITY DEW POINT AIR VELOCITY MASS FLOW TEMPERATURE CO 2 PRESSURE. (+34)

Calibration Procedure

CRITERIA FOR LABORATORY ACCREDITATION IN MASS METROLOGY

Accreditation for In-Service Inspection of Transportable Pressure Receptacles (TPRs)

ACCREDITATION OF ON-LINE LEAK SEAL ORGANIZATIONS

Discussion on Fugitive Emissions Standards Rich Davis

SUMMARY... 2 II. SCOPE... 3 III. LIST OF ABBREVIATIONS AND UNITS... 3 IV.

METROLOGY LAB. I DEVICES BASED ON VERNIER SCALE

Method of Test for Flat & Elongated Particles

Draft. Equipment/Instrument

The Use of ILI In Dent Assessments

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF MASS METROLOGY

TorqBolt Wedge Anchors Torque Controlled Expansion Anchor

ENGINEERING TECHNICAL REPORT

EN ISO/IEC Technical Requirements

Requirements and Methods for Calibration of Equipment in Clinical Laboratories. NK Chan (HKRCBTS) 24 August 2007

Durometer. SHT Series. Instruction Manual SHTD. Valid as of: Please keep the manual for future reference!

ISO 4081 INTERNATIONAL STANDARD. Rubber hoses and tubing for cooling systems for internal-combustion engines Specification

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Fact Sheet Oil Sands hoses Trelleborg Engineered Products The Netherlands

ISO 5355 INTERNATIONAL STANDARD. Alpine ski-boots Requirements and test methods. Chaussures de ski pour skis alpins Exigences et méthodes d'essai

ISO INTERNATIONAL STANDARD. Steel wire ropes for the petroleum and natural gas industries Minimum requirements and terms of acceptance

H&D Fitzgerald Pressure Pyknometry System Mark 5

PTC INSTRUMENTS 2301 Federal Ave Los Angeles CA Phone: Model 500 Automatic Operating Stand Type 3

Impact of imperfect sealing on the flow measurement of natural gas by orifice plates

This document is a preview generated by EVS

Vaisala Pressure, RH & Temp. Transmitter. The instrument was operational upon receipt. The instrument was adjusted and calibrated.

Certification of AMS acc. EN 15267, Part 3 - Overview and First Experience -

Beamex. Calibration White Paper. Weighing scale calibration - How to calibrate weighing instruments

Gas mixtures. Individual solutions specifically for your application

Bubble Viscometers A5-A1 / A-T / U-Z6 / Z7-Z10

Low Profile Load Cells

ISO 6804 INTERNATIONAL STANDARD. Rubber and plastics inlet hoses and hose assemblies for washing-machines and dishwashers Specification

Standard Recommended Practice. Field Measurement of Surface Profile of Abrasive Blast-Cleaned Steel Surfaces Using a Replica Tape

Calibration of wind direction sensors at Deutsche WindGuard Wind Tunnel Services GmbH

This document is a preview generated by EVS

APPENDIX 1. PART 10: Leak Detection Inspector, Level 1, 2 and 3 CERTIFICATION SCHEME FOR PERSONNEL. 3 rd Edition, February 2016

INFLUENCE OF MEASURING PROCESS AUTOMATION ON UNCERTAINTY OF MASS STANDARD AND WEIGHTS CALIBRATION.

WaterSense Specification for Spray Sprinkler Bodies. Version 1.0

DETERMINING OPTIMUM RESIDUAL ASPHALT CONTENT (RAC) FOR POLYMER-MODIFIED SLURRY SEAL (MICROSURFACING) MIXTURES

CORESTA RECOMMENDED METHOD N 6

DNVGL-CP-0187 Edition March 2016

ISO Vacuum gauges Calibration by direct comparison with a reference gauge

Equipment Accuracy / Selection

Interlaboratory comparison in the pressure range from 0 to 2 MPa for accredited calibration laboratories

INTERNATIONAL OIML R 32 RECOMMENDATION. Rotary piston gas meters and turbine gas meters ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

Testing of Active Flow Control actuators at harsh environment

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

AGILENT TURBOMOLECULAR PUMPS MEASUREMENT METHODOLOGY

Sartorius CCL kg Prototype Mass Comparator

ROTARY VISCOMETER. Rotary Viscometers MYR V0/V1/V2 acc. to ISO 2555/ASTM (Brookfield method) SERIE VR 3000

COMPFIRE CCFT-FP_550_55_ September 2010 Fin Plate Connection to Circular Concrete-Filled Tube Test Result

Mass Flowmeters. Mass Flowmeters for Gases

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Unique mounting features for Thermal Mass Flow Meters. By Martin Raab in cooperation with CaTeC b.v.

Florida Method of Test for MEASUREMENT OF WATER PERMEABILITY OF COMPACTED ASPHALT PAVING MIXTURES

Date of Shipment: Xxxxx 00, 20xx 3402c National Institute of Advanced Industrial Science and Technology National Metrology Institute of

Transcription:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 CORPORATE CONSULTING, SERVICE, & INSTRUMENTS, INC. University Park, 221 Beaver Street Akron, OH 44304 Michael Kent Warner Phone: 330 376 3600 CALIBRATION Valid To: November 30, 2019 Certificate Number: 1424.01 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following calibrations 1 : I. Dimensional Parameter/Equipment Range CMC 2, 5 ( ) Comments Micrometers Outside Diameter Up to 4 in (64 + 4L) μin ASME Grade 0 gauge blocks and optical flats; ASTM D5947-11 Parts 6; 8; Annex A.1 Calipers Up to 12 in 320 μin 360 μin ASME Grade 0 gauge blocks Master caliper checker Thickness Gauge 3 Up to 3 in Total mass applied (0 to 700) g 140 μin 720 mg ASME Grade 0 gauge blocks; ASTM D3767-03 (2014) parts 9 13; ASTM D5947-11 parts 6; 8; annex A1; ASTM D1056-14 Part 15.3.2 ASTM D751-06 Part 9.1 ISO 815-1 Part 4.4 certified electronic pan balance-force calculated (mass over area) (A2LA Cert. No. 1424.01) Revised 01/15/2018 Page 1 of 7

Cutting Dies Up to 12 in 620 µin 380 µin Hand tools CMM Surface Finish (8 to 32) µin AA 4.9 µin AA ASTM D395; ASTM D3182 II. Mechanical Parameter/Equipment Range CMC 2 ( ) Comments Durometer 4 Type OO, Type OOO Type OOO-S Type M (0 to 113) gf (0 to 113) gf (0 to 197) gf (0 to 79) gf 0.37 duros 0.38 duros 0.39 duros 0.35 duros ASTM D2240-15 parts (5 10) Triple beam balance Type A, B Type O, E Type C, D Type DO (0 to 822) gf (0 to 4436) gf 0.38 duros 0.37 Duros 0.39 Duros 0.36 Duros DuroCalibrator Indentor Geometry Length Diameter Angle Radius Digital Display Extension IRHD Type M force calculation by differential indention Dimensions Diameter Ball Foot OD Foot ID Mass Up to 1 in Up to 1 in (0 to 90) º Up to 0.5 in (0 to 100) Duro Up to 1 in Up to 0.300 mm (0.39 to 0.40) mm (3.20 to 3.50) mm (0.85 to 1.15) mm (0 to 200) g 800 µin 780 µin 0.14 780 µin. 940 µin 0.06 Duros 300 µm 140 µin (0.0036 mm) 0.94 points 330 µin (0.0084 mm) 0.49 mg Optical inspection under magnification ASTM D1415-06 Parts 3.11, 3.12, Table 1 and Table 3 ISO 48 Parts 5.2.1 5.2.5, Table 1 and Table 3 with certified calipers with certified balance (A2LA Cert. No. 1424.01) Revised 01/15/2018 Page 2 of 7

Durometer 4 (cont.) IRHD Type N and S2 force calculation by differential indention Dimensions Diameter Ball Foot OD Foot ID Mass (0 to 1.8) mm (2.49 to 2.51) mm (19 to 21) mm (5 to 7) mm (0 to 1000) g 140 μin (0.0036 mm) 0.53 points 330 μin (0.0084 mm) 9.8 mg ASTM D1415-06 Parts 3.11, 3.12, Table 1 and Table 3 ISO 48 Parts 5.2.1 5.2.5, Table 1 and Table 3 with certified calipers with certified balance D2240 Durometer Hardness Test Blocks All scales 1.5 points Certified durometer D1415/ISO 48 Durometer Hardness Test Blocks Type M Type S2 / N 0.94 points 0.53 points Certified durometer Resiliometer, Resiliometer Spring (0 to 100) points 1.7 points 2.3 points ASTM D2632-15 parts (5 11) Mooney Viscometer 3 (0 to 100) Mooney units (20 to 375) C (0 to 5) RPM 0.38 Mooney units 0.2 RPM ASTM D1646 0715 (2012) parts 6; 9; 10-12; 14; 15 Compression (0 to 1000) lbf (1001 to 2000) lbf (2001 to 3000) lbf (3001 to 4000) lbf (4001 to 5000) lbf 4.8 lbf 9.5 lbf 17 lbf 25 lbf 28 lbf Torque (0 to 73.5) in lbf (100 Mooney units) 0.28 in lbf Manufacturer s instructions & direct verification (A2LA Cert. No. 1424.01) Revised 01/15/2018 Page 3 of 7

Rheometers 3 Oscillating Disc Moving Die (0 to 200) in lbf (0 to 200) in lbf 0.46 in lbf 0.46 in lbf ASTM D2084-11, parts 6, 9-12 ASTM D5289-12, part 6, 8-10 (20 to 375) C (0 to 100) RPM 0.2 RPM Compression Torque (0 to 1000) lbf (1001 to 2000) lbf (2001 to 3000) lbf (3001 to 4000) lbf (4001 to 5000) lbf 0 to 200 lbf in 4.8 lbf 9.5 lbf 17 lbf 24 lbf 28 lbf 0.46 in lbf Manufacturer s instructions & direct verification Plastometer Compression Up to 1 in (0 to 25) lbf 300 µin 0.0012 lbf ASTM D926-08 (2013) parts 5; 9; 10; 11 (plate parallelism and force) Brittleness Point 3 and Temperature Retraction 3 (0 to -90) C Striker Radius Striker Speed (0 to -90) C Up to 12 in 780 µin 0.84 s 320 µm ASTM D2137-15, part 5 and ASTM D746-14, part 6 for Brittleness Point direct verification with radius gauge and timed speed measurement. ASTM D1329-08, part 5 for temperature retraction and direct comparison with ASME Grade 0 gauge blocks. (A2LA Cert. No. 1424.01) Revised 01/15/2018 Page 4 of 7

Parameter/Equipment Range CMC 2, 5 ( ) Comments Scales and Balances 3 (0 to 1000) mg (0 to 200) g (0 to 1000) g 0.26 mg + 0.6R 0.49 mg + 0.6R 9.8 mg + 0.6R OIML E2 weights ASTM E898-88 (2013) parts 7.1; 7.2; 7.3; 7.5 & 7.6 (1000 to 6000) g 0.75 g + 0.6 R NIST 105-1 Class F weights Abrader 3 RPM Vacuum Table TIR 72 rpm 55 in H 2 0 0.002 in 0.2 RPM 1.6 in H 2 0 540 µin Manufacturer s instructions to ASTM D3389-15, part 5 Weights 250 g 500 g 1000 g 0.014 g 0.014 g 0.014 g Mass (> 1 to 1000) mg (>1 to 200) g (>200 to 1000) g 0.26 mg 0.49 mg 9.8 mg OIML E2 weights (>1000 to 6000 g) 0.75 g NIST 105-1 Class F weights Shore Durocalibrator A-Scale D-Scale (0 to 822) g (0 to 4536) g 0.6 Duros 0.6 Duros NAVAIR 17-20MF-17 T-4 Brookfield Viscometer 3 @10 cp nominal @1000 cp nominal @5000 cp nominal @12 500 cp nominal @100 000 cp nominal 0.38 cp 13 cp 67 cp 200 cp 1100 cp ASTM D2196-15, part 5; 6; 7; 11; 15 & manufacturer s instructions RPM Contact/Optical (1 to 999.9) rpm 0.2 rpm Measure 3 Direct Verification (A2LA Cert. No. 1424.01) Revised 01/15/2018 Page 5 of 7

Extensometer / Tensile Tester 3 Tension& Compression Distance (0 to 250) lbf (0 to 1000) lbf (1001 to 2000) lbf (2001 to 3000) lbf (3001 to 4000) lbf (4001 to 5000) lbf Up to 12 in 1.1 lbf 4.8 lbf 9 lbf 16 lbf 24 lbf 28 lbf 320 µin ASTM E4-16, parts 7; 9; 10; 11; 12; 13; 14; 15; 16; 17; 18; 19; 20; 22; 23 E83-16 parts 4; 5 7; 8; Manufacturer s instructions and direct verification ASTM D412-16; D624-16; D413-98; D429-14; F152-09; D638-14; D1708-13; D1938-14; D2343-09; D3916-08; D4964-96; D2261-13; D4777-88; ASTM D3822/D3822M-14; D2256/D2256M-10 III. Thermodynamics Parameter/Equipment Range CMC 2 ( ) Comments Oven Calibration 3 Temperature Air flow velocity vane anemometer Air flow velocity hot wire anemometer (68 to 707) ºF (1000 to 4000) fpm (0 to 5) m/s (0 to 10) m/s (0 to 30) m/s (0 to 45) m/s 1.3 ºF 1.3 + 5.1 % r 0.04 + 1.2 % r 0.30 + 1.2 % r 0.42 + 1.2 % r 0.64 + 1.2 % r ASTM E145-94 (2011), part 4.1 ASTM D7969-16, parts 4; 5; 6; 7; X.1 Digital survey recorder, Type K thermocouple r is the ventilation rate calculated air changes per hour Ozone Monitors and (0 to 10) parts in 10 8 Chambers 3 (pphm) (10 to 100) parts in 10 8 (pphm) 0.11 parts in 10 8 1 part in 10 8 ASTM D4575-09 (2015), part 6; 7; 8; 9; 10; 15 X1; X2 ASTM D1149-07, parts 5; 7;11; 15; 18; 21 field service available for chamber only (A2LA Cert. No. 1424.01) Revised 01/15/2018 Page 6 of 7

Temperature Measure 3 (-90 to 0) C (0 to 375) C Temperature Measuring Devices (25 to 100) C (101 to 375) C 0.37 C 0.6 C Dry well temperature calibrator IV. Time & Frequency Parameter/Equipment Range CMC 2 ( ) Comments Time Measure 3 Up to 2 Hours 0.84 s Up to 120 s 0.84 s D2240-15, part 5.1 operating stand rate of descent 1 This laboratory offers commercial and field calibration services. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration and this laboratory meets A2LA R104 General Requirements: Accreditation of Field Testing and Field Calibration Laboratories for these calibrations. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer s site being larger than the CMC. 4 Calibration is performed according to manufacturer specifications and measure in gram force. 5 In the statement of the CMC, L is the numerical value of the nominal length of the device measured in inches and R is the resolution of the device under test. (A2LA Cert. No. 1424.01) Revised 01/15/2018 Page 7 of 7

Accredited Laboratory A2LA has accredited CORPORATE CONSULTING SERVICE & INSTRUMENTS INC. Akron, OH for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories. This laboratory also meets R205 Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated 8 January 2009). Presented this 10 th day of January 2018. President and CEO For the Accreditation Council Certificate Number 1424.01 Valid to November 30, 2019 For the calibrations to which this accreditation applies, please refer to the laboratory s Calibration Scope of Accreditation.