Service Manual. Mullion Hi-Rise 275N SOLAS dot twin chamber lifejacket with Hammar hydrostatic mechanism.

Similar documents
Hammar LifeJacket Inflator

CREWFIT 165 SPORT. self care and maintenance manual

The Service label can be found

ANNUAL SELF INSPECTION / SERVICING INSTRUCTION SHEET

SMA1060 INSTRUCTIONS FOR SELF INSPECTION SMA1061 MANUAL INFLATION SMA1062 AUTO INFLATION

ANNUAL SELF INSPECTION AND SERVICE INSTRUCTIONS

inflatables pfd s ANNUAL SELF INSPECTION AND SERVICE INSTRUCTIONS

Owner s Manual. MD3196 and MD3091 Compact Tactical Life Preservers. *Shown with the MA3090 Chest Belt/Crotch Strap Assembly

Personal Flotation Devices (PFDs) Lifejackets & Buoyancy Aids - The Facts

INFLATABLE PFD S INSTRUCTIONS FOR ANNUAL SERVICE AND SELF INSPECTION

CBP LPU- 40 Flotation Collar User s Manual

SMA1500 Instructions for Self Inspection SMA MANUAL INFLATION SMA AUTO INFLATION

LPU- 40 Flotation Collar

PFD 1 275N INFLATABLE JACKET

INSTRUCTION MANUAL. Featuring - Quick Burst Zipper Survival Operations Specialist SOLAS (74/96) Approved Lifejacket

SMA2100 Series CONSTANT WEAR LIFE PRESERVER VEST (CWLP) SMA2160 OWNERS MANUAL

Rapid Survival System

SMA1060 OWNERS MANUAL

ALPS Flotation Collar. User s Manual

Owner's Manual SMA2000 Series

DO NOT REMOVE PRIOR TO SALE MD1250

THIS CARD IS MAINTAINED TO PROVIDE PROCEDURAL TEXT ONLY AND IS NOT REPORTED TO ACMS

MD1250 TACTICAL INFLATABLE SIDE POUCH LP

SURVIVOR SERIES AIRCREW FLOTATION VEST PACKING INSTRUCTIONS

DO NOT REMOVE PRIOR TO SALE! OWNER S MANUAL for Model No. 1212

CleanAIR ARES CA-83. welding leather hood. Contents. 1 General information 2 Use 3 Technical specification 4 Maintenance 5 List of parts 6 Approvals

Tactical Flotation Support System (TFSS) User s Manual

Owner s Manual. MD Inflatable Vest with LIFT TM Hydrostatic Inflation Model - Manual with Automatic Backup

MAINTENANCE PROCEDURE FOR X 650

INDUSTRIAL LIFEJACKETS SWEDEN

AirForce Owner s Manual MD3031 Manual with Automatic Backup Inflation Model

Inflatable PFD Owner s Manual

ALSO AVAILABLE WITH HAMMAR VALVE ALSO AVAILABLE WITH HAMMAR VALVE

industrial lifejackets sweden

ExtendAire TM II. Intermediate Pressure Accessory Kit USER INSTRUCTIONS

INFLATABLE PFDs. MD2010 Manual Inflation Model. MD2012 Manual with Automatic Backup Inflation Model

2. Ensure that the leg strap buckles are not obstructed and operate smoothly.

M.E.D. / S O LA S TWO YEARS GUARANTEE SIZE kg SIZE kg. to M.E.D./SOLAS MSC 200 (80) and EN ISO ART NO 2105 EN ISO

MD5183 ELITE INFLATABLE PFD

AUXILIARY ACR PLB Monthly Inspection and Test For use by Auxiliary members issued ACR PLBs within District Eleven North Revised Jan 2016

M.E.D./SOLAS LIFEJACKETS INFLATABLE LIFEJACKETS

Owner s Manual. MD3184 Inflatable PFD Hydrostatic Inflation Model - Manual with Automatic Backup with Harness Recreational: USCG Approved Type V


WE SAVE LIVES FOR A LIVING

FOR MODEL NUMBERS MD2981 (MANUAL) / MD2983 (AUTO) OWNER'S MANUAL DLX 38 INFLATABLE PFD

BMW Motorrad. Installation Instructions. BMW Motorrad Communications System for Schuberth C3

FLOTATION CLOTHING STANDARDS IN CANADA ITS SESSION ~ OCTOBER 7, 2014

Flat Fold Highchair INSTRUCTION MANUAL. Designed and manufactured to BS EN 14988: 2012 IMPORTANT:

TABLE OF CONTENTS. Hello! Happy Paddling, SAFETY WARNING WHAT S INCLUDED IN YOUR BOX GENERAL USE INFORMATION INFLATION INSTRUCTIONS FIN INSTALLATION

BABY ROCKER WITH TOY BAR

Rescue Services Life Raft Manual

Owner s Manual. MD3085 Inflatable PFD Manual Inflation Model Recreational: USCG Approved Type III Uninspected Commercial Vessels: USCG Approved Type V

IMPORTANT:KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE. ROCK A BABY BABY ROCKER WITH TOY BAR INSTRUCTION BOOK Series LX9068

RB70 Automatic Diluent Valve Maintenance Manual. Version 1.1 November 2006 Written by Tino de Rijk. Page 1 of 23

Owner s Manual RESCUE STICK TM MRD100 THROWABLE EMERGENCY RESCUE INFLATABLE

Maintenance manual. Flight helmet LA100 PP

NORTHERN DIVER PFD MANUAL

SOTR Special Operations Tactical Respirator

Rapid Response Shelters. Rubber Product Manual

Sample Concentrator SBH CONC/1 Instructions for use

MD3183 / Hydrostatic Inflation Model / Manual with Automatic Backup USCG Approvals: Recreational: Type II Uninspected Commercial Vessels: Type V

Drawn up by: / RK Revision: 01 Reviewed: Page: 1 of 23 HI-SR 540 USA. Operating instruction SR 540 Face Shield

The same as the 3005 but with integrated safety harness. Double nonmagnetic

MD2014 INFLATABLE PFD Manual Inflation Model USCG APPROVALS: RECREATIONAL: TYPE III UNINSPECTED COMMERCIAL VESSELS: TYPE V

INSTRUCTION MANUAL. EEBD Emergency Escape Breathing Device OPERATION AND MAINTENANCE UNISCAPE 15 H. Mat. No / 04 Safety by

PFD GUIDANCE FOR COMMERCIAL FISHING RNLI A518pp Booklet V7.indd 1 26/04/ :49

COMFORT MAXTM BELT PACK

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

Inflatable Personal Flotation Device (PFD) OWNER S MANUAL

LEAK SEALING SYSTEMS

RECOVERY VEST MANUAL

B.C.D. Buoyancy Compensator Device User Manual

LTS BCD USER GUIDE. Hollis (2014) Doc r01 (8/29/14)

Owner s Manual. Model H4685

8. Carefully layout all the parts of the reservoir setup and clean any dirt, grime or dust from the parts. ( image 8 ) 8

Travel Wing. Buoyancy Compensator User Instruction Manual

Usage and Care Instructions

USER S MANUAL QUESTIONS? CAUTION. Model No. FMEX Serial No. Write the serial number in the space above for reference. Serial Number Decal

Personal Flotation Collar (PFC-1)

BELT DRIVE PREMIUM INDOOR CYCLING BIKE SF-B1509 USER MANUAL

Table Of Contents. General Information Pg 1 Limitations & Warnings Pg 1. Pre-checking the Air Supplied Gas Tight Suit Pg 2

INSTRUCTION MANUAL. Gas Salamander

Drawn up by: / RK Revision: 01 Reviewed: Page: 1 of 15 HI-SR 200 USA. Operating instruction APR SR 200 full face mask

Pectoral Machine. User manual E S S E N T I A L S T R E N G T H

Assembly, Fitting, Care & Maintenance

Assembly Instructions. for. Puffin Saranac. ScanSport, Inc. P.O. Box 700 (234 May Street) Enfield, New Hampshire Phone: (603)

Installation, Operating, Inspection and Maintenance Instructions Ladder Climber s Safety System. Warning

isup MANUAL THANK YOU FOR PURCHASING A KAHUNA isup, WE HOPE YOU HAVE MANY YEARS OF PADDLING ENJOYMENT.

GAS STRUT SAFETY INFORMATION

SPUD OWNER S MANUAL ALWAYS WEAR A COAST GUARD APPROVED FLOTATION DEVICE WHEN OPERATING THE SPUD KAYAK.

Checklist for care of Respirators

SERIES 2 RAMP OWNER S MANUAL TOOLS REQUIRED: BEFORE YOU BEGIN... Read and understand these instructions before beginning a ramp setup.

ASSEMBLY INSTRUCTIONS

BELT DRIVE INDOOR CYCLING BIKE SF-B1712 USER MANUAL

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

Training. Testor Training Manual

Combination Breathing Apparatus

Cleaning rod: spring steel, stainless steel or carbon fibre cleaning rod - only use a one-piece rod. Avoid using snakes.

Techcon Systems TS1258 Pressure Pot

SERVICE MANUAL MODEL BA200AMST-S1 BREATHING AIR PANEL

Transcription:

Service Manual Mullion Hi-Rise 275N SOLAS dot twin chamber lifejacket with Hammar hydrostatic mechanism.

2On board service manual 2 This manual is designed to help you fit, 1.0 Maintenance schedule. Only a responsible officer may perform the checks mentioned herein. All checks shall be recorded in an appropriate log - book. The records shall include the lifejacket serial number, date of check, and the last date of service (if applicable/ available). 2.0 Servicing/maintenance procedure at periods not exceeding 12 months!! The lifejacket should be visually inspected as per inspection check- list and the service requirements recorded. At 12 monthly intervals, or immediately if the lifejacket has been inflated or immersed in water, or load applied to harness/belt.

re-arm, re-pack and care for your Lifejacket. 3.0 check list. The following parts / areas should be checked: General materials / webbings / buckles / crutch-strap General stitching Zip & velcro fastenings Reflective tapes Automatic emergency light Whistle Automatic firing mechanisms Co 2 gas cylinders Oral inflation tubes / valves + full lifejacket inflation Buddy line 3 3

4On board service manual 4.0 Service check procedure. 4.1 General check Check that the lifejacket stole and cover match exactly the diagrams as attached and that all component parts are present. Check for damage / tears to all materials / component parts / trim & accessories. Any defects return to distributor / factory for service Missing / defective crutch-straps can be replaced on board with new parts supplied by Mariteam. Mullion Hi-Rise 275N dot twin chamber lifejacket with hammar hydrostatic mechanisms Double zip fastening cover 50 mm waist belt + retainer Interlocking buckles Crutch straps with buckle front and back + retainer FRONT D-ring fitted to centre front waist belt. 50 mm webbing harness and shoulder straps. 25 mm red grab / lifting strap BACK Back neck velcro fastenings are intact and secure Information label on the inside

4.2 General stitching Check all stitching are intact and secure. If any defects are observed discard the lifejacket or return for service 4.3 Zips & velcro fastenings Check all zips and velcro fastenings are intact and secure. If any defects are observed discard the lifejacket or return for service 4.4 Reflective tape Check all reflective tapes are in tact and adhered securely to the inflatable chambers. Any defects replace with new reflective tapes supplied by Mariteam 3 x 22 cm length SOLAS marine grade reflective tape silver Life jacket inflatable bladder double chamber 5 x 25 mm black webbing patches welded on inside to seal stitches for fixation on bladder in the cover 150 mm standard oral tube with dust cap 25 mm black webbing for fixation bladder in the cover 150 mm over pressure oral tube with dust cap Light strap Velcro to attach grap loop SOLAS light Buddy line + toggle 2 x 12 cm length SOLAS marine grade reflective tape silver FRONT Fixation point for inflation mechanism: Sealing ring for Hammar Manifold for United Moulders or Halkey 2 x 25 mm black webbing, at bottom bladder for fixation bladder in the cover BACK 5

6On board service manual 4.5 Automatic emergency light Check light function by switching on manually & / or immersing in water and ensure light is securely fastened to inflatable chambers Any defects replace with new light supplied by Mariteam 4.6 Whistle Check whistle is securely fastened to inflatable chambers and is functional Any defects replace with new whistle supplied by Mariteam 4.7 Automatic firing mechanism Check date of mechanism has not expired Check that the mechanism window is not showing red Check that the manual pull handle has not been removed or partially pulled Check there is no damage to the mechanism body and back assembly If any one of the above are found to not conform Remove and refit mechanism by following hammar instructions as attached: reference diagram 4.8 Co 2 gas cylinders To check the cylinder, the hammar mechanism must first be removed as per the instruction attached and then unscrewed from the Hammar back assembly 1. Check the cylinder is not pierced or damaged in any way 2. Check the cylinder is not corroded 3. The cylinder is less than 10 years old If any of these defects are found the cylinder must be replaced immediately and the old one discarded / disposed of (parts supplied by Mariteam). Automatic emergency light Whistle Automatic firing mechanism Co2 gas cylinder Neoprene sleeve

4.9 Oral inflation tubes/valves & full lifejacket inflation To check this a full inflation test is required as follows: Check that both front and back oral tubes are intact, undamaged and black dust caps are fitted With compressed air equipment or a manometer and through the standard oral tube on the back of the inflatable chambers, inflate the rear chamber to 0.5 p.s.i. or 3.5 k.p.a. With the same equipment inflated the front chamber through the front oral tube with over pressure valve until the over pressure valve blows off Leave the lifejacket inflatable chambers, inflated for a minimum of 12 hours Check the inflatable chambers after 12 hours if they are still at full pressure they can be deflated by depressing each valve in the oral inflation tubes at front and back and pressing down on the bladder to expel the air If the inflatable chambers have deflated in any way after 12 hours the inflatable chambers must be rejected and returned to the manufacturer for an interchangeable replacement 4.10 Buddyline Check if the corde of buddy line is intact and toggle is present. 5.0 General maintenance & cleaning 5.1 Cleaning of lifejacket If any part of the lifejacket has been in contact with salt water or other contaminants such as oil, paint thinner it shall be sponged off immediately with amild soap solution. Rinsed with clean fresh water and hung to dry. Do not immerse in water as this will activate the firing mechanism Do not use harsh cleaning agents / chemicals / dry cleaning fluids Do not place on direct heat to dry 5.2 Cleaning of CO 2 gas cylinders Co 2 gas cylinders after use / contact with salt water can be cleaned by wiping with a cloth soaked in clean fresh water and then dried immediately afterwards (to prevent corrosion) with a clean dry absorbent cloth 7

8On board service manual 6.0 Re-arming instruction Before starting the re-arming instructions ensure you have the correct re-arming kit with the correct size of CO 2 cylinder, and that the life jacket is dry. Keep the re-arming kit away from liquids. 1 STEP 1 2 STEP 2 3 STEP 3 Lay life jacket (PFD*) on a smooth flat surface and wipe off any water. Hold the gas cylinder through the fabric with one hand. * PFD: Personal Flotation Device 4 STEP 4 5 STEP 5 6 STEP 6 Take out the inner body with the gas cylinder, through the sealing ring. Insert metal key (a) as shown in 2a and turn the key counterclockwise (CCW) as shown in 2b between black locking ring (b) and labelled yellow cap. The black locking ring will now turn counterclockwise (CCW). Undo the neoprene cover from the cylinder and now unscrew the back assembly of the inflation system from the gas cylinder. Note: If hard to unscrew, hold the black inner body with a soft tissue/cloth and hold the cylinder with pliers or other holding tool. Dispose of used gas cylinder in an environmentally safe manner. Now turn black locking ring counterclockwise (CCW) and lift off cap. Dispose carefully of used cap in an environmentally safe manner. * CAP: yellow inflator operating head Reset the piercing pin by rotating the shaft in the inner body to a position where the underside monitor with eyelet surrounds the green dot in the centre of the indicator.

7 STEP 7 8 STEP 8 Carefully examine the top of the new gas cylinder to make sure that it is not punctured. Screw the cylinder into the body and tighten it by hand. 9 STEP 9 10 STEP 10 The gas cylinder must be firmly tightened to the black inner body. The black inner body should be checked for any damage or splitting following this tightening. Carefully slide the body into the bracket. Put the cylinder adapter tool on to the cylinder. Apply the torque wrench on to nut on the cylinder adapter tool and tighten the cylinder to a torque of not more than 10 Nm. Make sure the neoprene hood is fitted back onto the cylinder. Reinsert gas cylinder and inner body with gas cylinder pointing upward inside the life jacket. Let the sealing ring rest on the central body around the four lugs. 11 STEP 11 12 STEP 12 13 STEP 13 SNAP Now check the automatic cap as follows: Automatic: Is red handle attached? Is expiry date ok? Window shows green? If Yes is the answer to ALL these questions, then proceed to n 12. Hold the gas cylinder through the life jacket fabric. Take the replacement cap with the pull tab pointing in the opposite direction of the gas cylinder (i.e. down) and press it FIRMLY onto the inner body and sealing ring. While pressing firmly onto the inner body, turn the black ring clock-wise until it snaps in the locked position. Note: When the inflator is in its final closed position, the gas cylinder, the side of the yellow cap and the pull handle should all be in line vertically! 9

10On board service manual 7.0 Re-packing the lifejacket MPLJ2S01M Once both the bladder and cover have been finally checked, the bladder is packed into the cover using the method explained below and visually depicted in the packing procedure illustrations. By using the folding method and fastening the buckles on the waist belt and crutch strap correctly, the bladder should work efficiently and open correctly when deployed. With the bladder laid flat on the table again proceed to fold and repack as per the illustrated diagrams as follows. Close back neck velcro. Fold the right side bladder lobe (as worn) at the outer edge once toward the centre front. 01 02 03 04 Fold hinge of bladder toward the neckline. Now the back part of the bladder should be laid flat. 05 06 07 08 Fold the bottom part of the right side bladder lobe (as worn) away from the lower edge of the cover. Fold the bottom part of the right side bladder lobe (as worn) back towards the lower edge of the cover. Fold the right side bladder lobe (as worn) at the centre front edge twice in concertina style. 09 10 11 12 Fold the right side bladder lobe at the centre front (as worn) + buddy line half next to the inflator. Fold the edge of the back part towards the neckline. Position the inflator pull cord and handle out of the back slot in the cover ensuring that it hangs down freely at the back. Fold the back part in 2 from neckline towards the outer edge. Fold the top corner outer edge down and in towards the centre front.

MPLJ2S01M 13 14 15 16 1. 2. Using the zip slider, pull the zip all the way from the bottom centre front up to the top back neck and ensure that you pull it all the way to the end of the zip under the velcro and fasten the velcro securely back over the end. Then pull the zip slider all the way back down again to the bottom centre front. The zip should now be completely closed on this side and the bladder securely inside the cover. Fold the bottom part of the left side bladder lobe (as worn) away from the lower edge of the cover. Fold the bottom part of the left side bladder lobe (as worn) back towards the lower edge of the cover. 17 18 19 20 Fold the left side bladder lobe (as worn) at the centre front edge twice in concertina style. Fold the left side bladder lobe (as worn) at the outer edge twice in concertina style. Position the inflator pull cord and handle out of the back slot in the cover ensuring that it hangs down freely at the back. Attach the grab/lifting strap onto the velcro on the bladder. 21 22 23 24 1. 2. Fold the top corner outer edge down and in towards the centre front. Using the zip slider, pull the zip all the way from the bottom centre front up to the top back neck and ensure that you pull it all the way to the end of the zip under the velcro and fasten the velcro securely back over the end. Then pull the zip slider all the way back down again to the bottom centre front. The zip should now be completely closed on this side and the bladder securely inside the cover. Clip the crutch strap into the buckles on the centre back strap and left front belt 11

7 Storage when not in use the lifejacket should be stored in a well ventilated room, not subject to extremes in temperature, extended periods of bright sun light, hydro carbon fumes, oils creases or concentrated ozone. The storage conditions must not be damp or extremely humid. the lifejacket must always be dry prior to placing in storage. Lifejackets held in store must be laid flat or hung from the neck aperture by suitable means. Prior to issue from store a visual inspection must be performed. A damaged lifejacket must be subject to the service / maintenance procedure before being issued for use or returned to the store. Providing the storage conditions are satisfactory the lifejacket may remain stored between service/ maintenance periods. 8 Spare parts list Description: SOLAS S.O.S. light Mullion part nr.: LLI00000U Description: 60gr cylinder Mullion part nr.: LCY030000 Description: Hammar auto front Mullion part nr.: LIN01F000 part description Description: Whistle Mullion part nr.: LWH030C10 Description: Hammar back Mullion part nr.: LIN01B000 Description:Solas reflectors self-adhesive Mullion part nr.: NR IRFQ50MOR 12CM Mullion part nr.: IRFQ50MOR 22CM Description: neoprene sleeve for gas cylinder Mullion part nr.: 1mzwa2yn3 For more information contact us: MariTeam A/S Marielundvej 17 DK-2730 Herlev Telefon: +45 39 18 66 44 TeleFax: +45 39 18 07 57