PARTS, SERVICE & REPAIR BULLETIN

Similar documents
PARTS, SERVICE & REPAIR BULLETIN

OXY FUEL SYSTEM SET UP & SHUT DOWN PROCEDURE CHECKLIST ACETYLENE FUEL GAS

Safety, Set-Up, and Operating Instructions

Safe Work Instructions For Oxygen Acetylene Equipment

ASSEMBLY & OPERATIONS MANUAL. Straight & Clean Torch Cuts. Every Time.

V-24 OXYGEN LANCE VALVE

SAFETY AND OPERATION MANUAL

Oxy-Fuel Safety Training. Participant s Guide

LRS(H)4 Pressure-Reducing Regulator User Manual

3/8" Dr. Air Butterfly Impact Wrench

OXYGEN ACETYLENE WELDING & CUTTING EQUIPMENT

LITTLE MAX MODEL 50G 50,000 BTU PROPANE TORCH

Hydraulic Punch Drivers

Maintenance and Repair. AirHawk II Air Mask. Second Stage Regulator. Order No.: /02 Prnt. Spec (I) MSAsafety.

MAINTENANCE PROCEDURE FOR X 650

Visit our Web site: http: //

oxyacetylene welding/cutting torch set

RG1200 Service and Repair Manual

Product Information News September 26, 2003

Regulators repair and maintenance. XS Compact 2nd stage. January 2014 Rev XSC /3 Ed. C /14 1

INSTRUCTION MANUAL. Models: OX2550KC WK5500OX DO NOT DISCARD THESE WARNINGS AND INSTRUCTIONS

COMMERCIAL ITEM DESCRIPTION TORCHES, OXYACETYLENE, HAND HELD, CUTTING AND WELDING

Auto-Rewind Hose Reels INSTRUCTION MANUAL FOR OXY-LPG MODEL

CS150 CAP STAPLER OWNER S MANUAL

Booster Pump PB4-60 Replacement Kits

welding torches [all models]

Hotspotter. Model WB-100 Professional Series. Assembly, Testing & Operating Instructions. Safety Information:

Air Mask Low/High Pressure

OPERATING INSTRUCTIONS AND OWNER S MANUAL READ AND FOLLOW ALL INSTRUCTIONS

INTENDED USE TECHNICAL SPECIFICATIONS

U.S. CONCRETE, INC. SAFETY POLICY and PROCEDURE MANUAL

General Precautions for handling compressed gases

Service and Repair Manual

Compressed Gases Storage and Handling Safety Policy. Individual Unit Function: Safety Procedure No.: SOP-0103 Page: 1 of 6

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

RD(H)20/25 Pressure-Reducing Regulator User Manual

Natural Gas Conversion Kit

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP

12S 1st Stage. -Maintenance Procedure-

Product Information News

Technical Operating Instructions for Magnum Cutting Systems. for online instructions

Operation Manual Piston Sensed Gas Pressure Regulators

Freedom8 ShoeBox Compressor Manual

G250/G250 HP Compatibility of Upgrade Kit

Yoke Block Instruction Manual

MMR Air Mask With. with Quick-Connect Hose

Contents. Stainless Steel Side Block. 1.1 Separating the Side Block. Stainless Steel Side Block Reassembly of. Assembly from the Helmet Shell

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

Hydraulic Piston Accumulators

CW-23, CW-23/FG-2, & CW-24-R CUTTING ATTACHMENTS

SCUBAPRO Repair Guide. S600-S550 Second Stages

TRADE OF HEAVY VEHICLE MECHANIC

EXOTHERMIC TORCH ADAPTER. Instruction Manual

Doc No: WELDHOT Midland Engineering Co., Inc. Initial Issue Date 12/14/15 Safety Management System

SALCO PRODUCTS, INC. PRESSURE RELIEF VALVE STORAGE, INSTALLATION, OPERATING, MAINTENANCE/TESTING, AND INSPECTION INSTRUCTIONS

Natural Gas Conversion Kit

Yoke Block Instruction Manual

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

! WARNING! IMPORTANT HPA AIR TANK SAFETY INSTRUCTION AND GUIDELINES ! WARNING! IMPORTANT SAFETY INSTRUCTION AND GUIDELINES


HOT SHOT OPERATING INSTRUCTIONS AND OWNER S MANUAL. Model SPC-500. (Propane Torch)

OXYGEN & ACETYLENE: Safety & Handling for these Highly Combustible Gases

Mastar Outfits KL550-TR KL550-4P-T

fig.1 Instructions for: Gas welding/cutting kit

H4802, H4802-1, H , and Pole Tampers

CO2 Tank Conversion Kit P.N , P.N , and P.N

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

Tri-Safem Model I1 Regulator. INSTRUCTIONS and PARTS

Working Environment Safety Assessment

HEAVY-DUTY AIR RATCHET WRENCH OWNER S MANUAL

Section 35 Brieser Construction SH&E Manual

INSTRUCTION MANUAL For Gas Welding, Cutting, Brazing & Heating Torches.

Installation and Operation Instructions

Carter Option X Valve connector assembly. Maintenance manual

IMPACT WRENCH ASSEMBLY AND OPERATING INSTRUCTIONS

A guide to Part 10 of the

Gas Conversion Kit Pilot Ignition Heaters

Medium-Duty Oxy-Acetylene Cutting and Welding Outfit

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

NEW Edge Series Products: OUTFITS and REGULATORS

Rejuvenation Instructions

Composite Pistol-Type Air Needle Scaler OWNER S MANUAL

AIR INLINE METAL SHEAR

Right-Angle Tube Roller Model

Operating manual. LINDOFLAMM Acetylene special burner LF-H series.

DS06D,G Dial Set Pressure Regulating Valve

Air Intake Snorkel Kit

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Welker Magnetic Indicator (With Gravity Mixer) Model CP2GM-HP

Instruction Manual Updated 7/26/2011 Ver. 2.2

Operating Instructions Manual for

Paintball Marker. User s Manual. 530 South Springbrook Road Newberg, OR 97132

TURBO SET 1000 E D $'9 5(9

Service and Repair Operative Manual MC9 1 st STAGE. MC9 1 st Stage. 1 st STAGE MC9. Jannuary Rev. MC9 /B Ed. C/13

GAS CONVERSION KIT Installation Instructions Range/Rangetop

Glasgow City Council EDUCATION SERVICES. Technician Support Service

1 DRIVE INDUSTRIAL IMPACT WRENCH

Transcription:

CA4- PARTS, SERVICE & REPAIR BULLETIN 400 SERIES HEAVY DUTY CUTTING ATTACHMENT, TIP SERIES Manual No: 0056-379 Issue Date: August 2, 203 Revision: AB VictorTechnologies.com

Table of Contents SECTION : GENERAL SAFETY INFORMATION...2.0 Commonly Used Terms...2 SECTION 2: SPECIFICATIONS...3 2.0 CA4- Victor Cutting Attachment...3 2.02 Repair Parts List...3 SECTION 3: SERVICE & REPAIR INSTRUCTIONS...4 3.0 Recommended Tools & Supplies for Repair Procedures..4 3.02 Cleaning Procedures...4 3.03 Control Valve Repair Kit...4 3.04 Cutting Lever...4 3.05 H.P. Oxy Valve Repair Kit...5 3.06 Cone End Repair Kit...5 3.07 400 Series Head Repair Kit...6 3.08 Gas Feed Tubes...6 SECTION 4: TEST PROCEDURES...7 4.0 Recommended Tools & Supplies for Test Procedures...7 4.02 Leak Test the Gas Regulator...7 4.03 Leak Testing the Torch...7 4.04 Flame Testing the Torch...7 SECTION : GENERAL SAFETY INFORMATION Read and understand all safety and operating instructions provided before using this apparatus. RETAIN THESE INSTRUCTIONS IN A READILY AVAILABLE LOCATION FOR FUTURE REFERENCE. DO NOT attempt to use this apparatus unless you are trained in its proper use or are under competent supervision. For your safety, practice the safety and operating procedures described in this booklet every time you use the apparatus. Deviating from these procedures may result in fire, explosion, property damage, and/or operator injury. If at any time the apparatus you are using does not perform in its usual manner, or you have any difficulty in the use of the apparatus, STOP using it immediately. DO NOT use the apparatus until the problem has been corrected! Apparatus improperly operated, maintained or repaired can be dangerous. Some parts and accessories manufactured by others may fit VICTOR apparatus but not conform to VICTOR s exacting standards. For your own protection, specify and use ONLY VICTOR-made parts and accessories with your VICTOR apparatus. or repair of apparatus should be performed only by a qualified repair technician capable of servicing gas apparatus in strict accordance to applicable Part and bulletins for VICTOR manufactured products. Improper service repair, or modification of the product could result in damage to the product or injury to the operator. WARNING: This product contains chemicals, including lead, known to the State of California to cause birth defects and other reproductive harm. Wash hands after handling..0 COMMONLY USED TERMS BACKFIRE - The return of the flame into the torch, producing a popping sound. The flame will either extinguish or reignite at the tip. SUSTAINED BACKFIRE - The return of the flame into the torch with continued burning within the torch. This condition may be accompanied by a popping sound followed by a continuous hissing or whistling sound. FLASHBACK - The return of the flame through the torch into the hose and even into the regulator. It may also reach the cylinder. This condition could possibly cause an explosion in the system. 2

SECTION 2: SPECIFICATIONS 2.0 CA4- VICTOR CUTTING ATTACHMENT Cutting Tip Series Intuitive knobs: color coded, clearly marked lettering with increase/decrease label. Understandable in any language. Improved Stainless Lever provides increased comfort and reduced operator hand fatigue. Redesigned inlet nut increases grip for Hand Tightening. Uses #000 - #6 cutting tips. One torch for All Fuel Gases (with proper tip). Inline stainless tubes for better visibility and reduced profile vs triangular design. Efficient Universal Head Mixer reduces Torch Profile for Better Visibility. Optimized to use Cutting Attachment for All Fuel Gases. /2 2 2 3 3/8 9 7/8 All dimensions are approximate. 2.02 REPAIR PARTS LIST 400 Series Head 90 Control Valve Cone End H.P. Oxy Valve Cutting Lever Tip Nut Gas Feed Tubes CA4-3

SECTION 3: SERVICE & REPAIR INSTRUCTIONS 3.0 RECOMMENDED TOOLS & SUPPLIES FOR REPAIR PROCEDURES 3/8, 5/8, 9/6, and /6 Open-End Wrenches Vise 5/6 Box-End Wrench 45% Silver Solder 3/6 Drift Punch Silver Solder Flux Small Hammer Loctite #222 (Part Number 0028-008) Cone End Clamp RT-08 Christo-Lube 29 (Part Number 0034-002) Brazing Torch Hand Reamer RT-8 Pliers Air Hose NOTE Disconnect cutting torch from any gas lines or other hardware before beginning any service or repair. 3.02 CLEANING PROCEDURES Contact your local chemical supplier for recommended cleaning solvents applicable to the metals used in this product. Always use cleaning solvents in accordance with the manufacturer s instructions. WARNING DO NOT allow nonmetal components (Seat, O-Rings, Dust Seal, Gaskets) to contact cleaning solvents! Cleaning solvents cause elastomeric and plastic parts to swell and stress crack. If these parts require cleaning, use a mild soap solution, followed by a thorough rinsing in water. Dry these parts completely before installing. REPLACE NONMETAL PARTS THAT HAVE COME IN CONTACT WITH OIL, GREASE OR ANY OTHER PETROLEUM-BASED SUBSTANCE! Petroleum-based substances become dangerously flammable in the presence of oxygen. 3.03 CONTROL VALVE REPAIR KIT 3.04 CUTTING LEVER Control Valve Control Valve Repair Kit 0390-0086 Valve Stem 0662-002* *Sold as part of kit only. Wipe with dry cloth. Do not use any cleaning solvents. Check for leaks. Disassembly. Place torch in a vise. 2. Use a wrench to unscrew the Control Valve Nut.. Apply Christo-Lube to threads. 2. Screw Control Valve into Cutting Torch Body 3. Use a wrench to tighten the Control Valve Nut. 4. Apply green colored O (Oxygen) decal on knob. 5. Remove from vise. Cutting Lever Cutting Lever 0307-004RP Check Roll Pin for wear. Check Lever Tabs for alignment to Oxy Valve Groove. Disassembly. Using Punch, tap Roll Pin out of Lever Handle and Cutting Torch Body. Inspect and discard Roll Pin if deformed. NOTE Replacement Roll Pin part number is 404-0002. 2. Slide Lever Handle forward. If Roll Pin was discarded, acquire a replacement Roll Pin before beginning this step.. Align Lever Tabs with Valve Stem. 2. Confirm Lever Tabs align with Valve Stem Groove and insert Roll Pin into Lever and Torch Body. 3. Gently tap in Roll Pin. 4

3.05 H.P. OXY VALVE REPAIR KIT 3 6 2 H.P. Oxy Valve 5 4 3. Install the Washer followed by the small O-Ring on the Valve Stem. 4. Apply Christo-Lube to the outside of the small O-Ring and along the Valve Stem. 5. Insert the Seat with Bushing, Spring, Washer, and O-Ring in through the Valve Cap. 6. Place the large O-Ring around the outside of the Valve Cap and apply Christo-Lube to the large O-Ring. 7. Screw the Oxy Valve into the Cutting Torch Body and wrench tighten. Confirm O-Rings are seated properly. 8. Reattach the Cutting Lever. (See Section 3.04, Cutting Lever) 9. Remove from vise. 0. Check for leaks. 3.06 CONE END ASSEMBLY REPAIR KIT 2 H.P. Oxy Valve Repair Kit 0390-0043 Seat 0320-0079 2 Seat Bushing 0320-008 3 Valve Spring 0320-0024 4 Washer 406-0006 5 O-Ring (Small) 407-0005 6 O-Ring (Large) 407-006 3 4 CAUTION Discard all used O-Rings, Seat, Seat Bushing and Washer. Replace them each time you reassemble a cutting torch. Wipe with dry cloth. Do not use any cleaning solvents. Check for leaks. Replacing O-Rings requires disassembly. Disassembly Remove the Cutting Lever before beginning the task.. Place torch in a vise. 2. Use a wrench to loosen and unscrew the Oxy Valve from the Cutting Torch Body. 3. Remove the Oxy Valve from the Cutting Torch Body making sure the large O-Ring is also removed. NOTE Check Valve Cap for wear. If Valve Cap was discarded, acquire a replacement Valve Cap before beginning these steps. Replacement Valve Cap part number is 0320-007.. Install the Seat Bushing on the Valve Stem, open end facing out. 2. Install the Spring on the Valve Stem until it is against the Bushing. Cone End Cone End Repair Kit 0390-0087 Cone End 037-0008* 2 Coupling Nut 0309-036* 3 O-Ring 407-078 4 O-Ring 407-077 *Sold as part of kit only. There MUST be two (2) sealing O-Rings in good condition on the Cone End. The absence of either O-Ring creates a condition that allows pre-mixing of oxygen and fuel gases. Use an air hose to clear any debris from opening. Replace O-Rings on Cone End. Check for leaks. 5

Disassembly Remove the Cutting Lever before beginning the task.. Place torch in RT-08 by mounting Cone End in fixture. 2. Use a wrench to loosen and unscrew the Cone End. 3. Clean opening in Cutting Torch Body. 4. Discard old Cone End from RT-08.. At the beginning of the Cone thread, apply a small amount of Loctite. Loctite must completely cover the beginning two threads of the Cone end. 2. Screw Cone End into Cutting Torch Body. 3. Place torch in RT-08 by mounting Cone End in fixture. 4. Immediately use a wrench to tighten the Cone End into the Cutting Torch Body. Consider using a small hammer to tap wrench tighter to seat threads and set Loctite. 5. Remove from RT-08. 6. Reattach Cutting Lever. (See Section 3.04, Cutting Lever) 7. Check for leaks. 3.07 400 SERIES HEAD REPAIR KIT CAUTION Always wear gloves when handling heated parts. Disassembly Remove the Tip, Tip Nut, Cutting Lever, Control Valve, and H.P. Oxy Valve before beginning this task.. Place the torch body in a vise, positioned so that you have full access to the 400 Series Head. 2. Heat the Gas Feed Tubes until solder liquefies. Use pliers to remove 400 Series Head.. Clean gas Gas Feed Tube of all solder and debris. 2. Place new 400 Series Head on Gas Feed Tubes. Confirm correct orientation to 400 Series body. 3. Ensure that the center tube is pressed firmly against the mixer of the head. 4. Solder fittings and allow to cool before beginning the next step. 5. Use RT-8 to finish hand reaming torch seat. 6. Remove all chips and debris around seat area. 7. Reattach the Control Valve (See Section 3.03, Control Valve Repair Kit) and H.P. Oxy Valve (See Section 3.05, H.P. Oxy Valve Repair Kit). 8. Reattach the Cutting Lever (See Section 3.04, Cutting Lever), Tip Nut, and Tip. 9. Check for leaks. 3.08 GAS FEED TUBES CAUTION Always wear gloves when handling heated parts. 2 2 400 Series Head 90 Victor Series Head Repair Kit 0390-0085 400 Series Head-90 Victor 0302-0247* 2 Mixer 0305-059* *Sold as part of kit only. Remove Tip Nut and Tip and use an air hose to clear any debris from opening. Reattach Tip Nut and Tip. NOTE Repair kit does not include Tip Nut. Tip Nut part number is 0390-0088. Gas Feed Tubes Gas Feed Tubes 0390-0090 5/6 Tube 0303-090* 2 2 3/8 Tube 0303-0200* *Sold as part of kit only. Check tubes for leaks and wear. 6

Disassembly Remove the Tip, Tip Nut, Cutting Lever, Control Valve, H.P. Oxy Valve, Cone End, and 400 Series Head before beginning this task.. Place the torch body in a vise, positioned so that you have full access to the Gas Feed Tubes. 2. Heat the Gas Feed Tubes until solder liquefies. Use pliers to remove all tubes. 3. Allow the torch body to cool before beginning assembly.. Clean the torch body of all solder and debris. 2. Place a new 400 Series Head in a vise, positioned so that the tube bores face up. 3. Insert the Gas Feed Tubes into the 400 Series Head, followed by the torch body. Confirm correct orientation to the 400 Series Head. 4. Ensure that the center tube is pressed firmly against the mixer of the head. 5. Solder the fitting around the 400 Series Head and repeat for the torch body side. Allow to cool before beginning the next step. 6. Complete steps 5-9 in Section 3.07, 400 Series Head Repair Kit,. SECTION 4: TEST PROCEDURES 4.0 RECOMMENDED TOOLS & SUPPLIES FOR TEST PROCEDURES Oil-free air or dry nitrogen supplies Oxygen and acetylene gas supplies Small water tank 4.02 LEAK TEST THE GAS REGULATOR. Close the Cylinder Valves. 2--0 Cutting tip 3/8, 5/8, 9/6, and /6 Open-end wrenches 5/6 Box-end wrench 2. Turn the Pressure Adjusting Screws one turn counterclockwise. If the High Pressure Gauge reading drops, there is a leak in the Cylinder Valve, Inlet Fitting, or High Pressure Gauge. If the Low Pressure Gauge drops, there is a leak in the Torch Handle Valve, Hose, Hose Fitting, Outlet Fitting, or Low Pressure Gauge. If the High Pressure Gauge drops, and at the same time the Low Pressure Gauge rises, there is a leak in the Regulator Seat. Have a qualified repair technician repair the Regulator. 3. Use an approved leak detector solution to check for leaks. 4.03 LEAK TESTING THE TORCH. Connect the Torch to oil-free air or dry nitrogen supply lines with matching type regulator. 2. Insert a plugged cutting tip into Torch. 3. Pressurize the hoses to 50+/-5 PSIG. 4. Completely submerse the Torch in water. 5. Open the Valve Stem Assemblies. Check for leaks around all external connections. Observe the Valve Stem Assemblies. If bubbles are escaping from around the Valve Stem packing, tighten the Packing Nut until it takes -/4 to 2 in-ibs of torque to adjust the Valve Stem knobs. 6. Close the Valve Stem knobs to a torque of 7-8 in-ibs. 7. Remove the Plugged Cutting Tip from the torch. Observe the Torch Head. If bubbles appear at the Torch Head, one or both of the Valve Stem Assemblies is leaking. Ream the Valve Seating surface using RT-33 reseating tool. Repeat steps 2 through 7. 4.04 FLAME TESTING THE TORCH. Remove the Torch from the water. Open the Valve Stem Assemblies for 0 seconds. Once all the water has been removed from the Torch, disconnect the hoses from the oil-free air or dry nitrogen supply. Attach them to oxygen and acetylene gas supplies. 2. Install a 2--0 cutting tip in the head. Tighten the Tip Nut to 5-20 ft-ibs of torque. 3. Adjust the oxygen to deliver 40+/-5 PSIG. Adjust the acetylene to deliver 8+/-3 PSIG. 4. Open the Oxygen Valve and purge the oxygen line for five seconds. Then, close the Oxygen Valve. Open the Fuel Valve and purge the fuel line for five seconds. 7

5. Open the Fuel Valve Stem about /8 of a turn. Ignite the gas with a spark lighter. Continue opening the Fuel Valve until the flame stops smoking. 6. Open the Oxygen Valve until a bright neutral flame appears. 7. Place the Tip on a fire brick at approximately 0 from the vertical (see Figure). Depress the Cutting Oxygen Lever. Rock the Torch from side to side for 5-8 seconds. The Torch will pop during this operation. 0 0 Fire Brick If you experience a backfire or backflash (flame disappears suddenly and/or a hissing sound IS heard when the flame is burning inside the torch), IMMEDIATELY turn OFF first the Oxygen Valve and then the Fuel Valve. Allow the Torch to cool before reusing it. If the trouble reoccurs, disassemble the Torch. Replace any damaged parts. 8. After testing is completed, release the Cutting Oxygen Lever. Close the Oxygen Valve and the Fuel Valve. 9. Close the Cylinder Valve or Gas Supply. 0. Open the Oxygen Valve. Release the oxygen from the system. Once all the oxygen is released from the system, close the Oxygen Valve.. Open the Fuel Valve. Release the fuel gas from the system. Once all the fuel gas is released from the system, close the Fuel Valve. 2. Remove the Hoses from the Torch. THE AMERICAS Denton, TX USA U.S. Customer Care Ph: -800-426-888 (tollfree) Fax: -800-535-0557 (tollfree) International Customer Care Ph: -940-38-22 Fax: -940-483-878 Miami, FL USA Sales Office, Latin America Ph: -954-727-837 Fax: -954-727-8376 Oakville, Ontario, Canada Canada Customer Care Ph: -905-827-455 Fax: -800-588-74 (tollfree) EUROPE Chorley, United Kingdom Customer Care Ph: +44 257-26755 Fax: +44 257-224800 Milan, Italy Customer Care Ph: +39 023654680 Fax: +39 0236546840 ASIA/PACIFIC Cikarang, Indonesia Customer Care Ph: 622-8990-6095 Fax: 622-8990-6096 Rawang, Malaysia Customer Care Ph: +603 6092-2988 Fax: +603 6092-085 Melbourne, Australia Australia Customer Care Ph: 300-654-674 (tollfree) Ph: 6-3-9474-7400 Fax: 6-3-9474-739 International Ph: 6-3-9474-7508 Fax: 6-3-9474-7488 Shanghai, China Sales Office Ph: +86 2-64072626 Fax: +86 2-64483032 Singapore Sales Office Ph: +65 6832-8066 Fax: +65 6763-582 T ECHNOLOGIES INNOVATION TO SHAPE THE WORLD U.S. Customer Care: 800-426-888 Canada Customer Care: 905-827-455 International Customer Care: 940-38-22 202 Victor Technologies International, Inc. www.victortechnologies.com Printed in Mexico