Dräger Swede Survival System Phase 1 Flashover Development Observation

Similar documents
CFBT LEVEL I COURSE INFORMATION SHEET

CFBT LEVEL II COURSE INFORMATION SHEET

Ocean County Fire Academy. Fall 2018 Course Listings

At your side in the mining industry

Training Benzene Awareness. Basic Information

Dräger PSS 3000 Self-Contained Breathing Apparatus

Dräger Mine Refuge Chamber MRC 5000 Innovative, portable life support system

===============================================================

Dräger ERS-Chamber Refuge Chambers

CLEARWATER FIRE ACADEMY

Iowa s s Minimum Training Standard. How to Be Prepared?

Dräger RZ 7000 Test Equipment

CLEARWATER FIRE ACADEMY

Dräger Engineered Refuge Solutions Unmatched flexibility and mine safety

Dräger ERS-Chamber Refuge Chambers

Autumn 2018 Firefighter 1

CLEARWATER FIRE ACADEMY

BASIC FIRE SCHOOL VENTILATION, SALVAGE & OVERHAUL

D Reliability goes XL

CLEARWATER FIRE ACADEMY

Dräger PSS 5000 (NFPA 2013 Edition) Self-Contained Breathing Apparatus

Model SOP Standard Operating Procedure

West Metro Fire Protection District

2017 Volunteer Week - Course Descriptions

Ultra-High Pressure Firefighting: The Fastest Attack

Idaho Fire Service Technology Fire Fighter II

D At your side in the mining industry

Land Based Marine Fire Fighter Task Book

Neutral Disinfectant Cleaner Cleaning, Disinfecting and Drying

Dräger RZ 7000 Test Equipment

Focused on essentials DRÄGER SAVINA 300

FIRE FIGHTER II JPR: FFII-1A

Special Edition. Back To Basics. Search Operations. A Review of the Basics of Fireground Search

Dräger Compressed Air Breathing Cylinders Accessories for Breathing Apparatus

Direct attack. 1 Introduction

The right protection for individual faces. Fit testing: Ensuring correct fit of RPE mask to the face

Wilson County Emergency Management Agency 110 Oak Street Lebanon, Tennessee 37087

TRAINING CENTER USAGE FORMS & REMINDERS

Dräger Bodyguard 1500 Warning Device

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 8 Search and Rescue Basics Revised

Alabama Smoke Diver Policies

The term MAYDAY typically will be used in the following situations:

Dräger PA91 plus Standard and PA91 plus Marine Self Contained Breathing Apparatus

Fire Apparatus Operator (FAO)

Dräger NITROX 200 Diving Equipment

Dräger X-plore 6300 Full Face Mask

ELYRIA TOWNSHIP FIRE DEPARTMENT TRAINING COMPLEX STANDARD OPERATING PROCEDURES. Effective Date: 02/20/12 Revised: 02/12

Skill Sheet 17-I-2. Attack a structure fire above, below, and at ground level Interior attack. (NFPA 1001, , )

PBCFR Reserve Battalion Combat Skills Check Off

North Carolina Fire and Rescue Commission Live Fire Audit Form

Enabling Objectives (EO): EO Identify certain practices that could be considered unsafe and result in injury or death.

Dräger X-pect 8500 Goggles Protective Eyewear

D Beyond essentials DRÄGER SAVINA 300 SELECT

Policy and Procedures Manual

D Designed for non-invasive ventilation DRÄGER CARINA

Cobra Cold Cut System

Dräger HPS 3500 Head Protection System

Alabama Fire College Rapid Intervention Crews Instructional JPR Verification Sheet

Dräger X-plore 3300 Half Mask

13 Search and Rescue

Thought of everything? Expert tips for working safely in confined spaces

Call Now: , press 1 to register.

Dräger ABIL-L Airline Equipment

SITUATIONAL AWARENESS, DISORIENTATION and IMPROVING FIREFIGHTER SURVIVAL AT STRUCTURAL FIRES

Live Fire Training Safety 3 1 n/a 30 No None Video (a) CD-Rom (p) 3 1 n/a 30 No 1A and 1S or equivalent

D Transport ventilation without compromise DRÄGER OXYLOG 3000 PLUS

HyResponse Operational training platform

Focused on essentials DRÄGER SAVINA 300

Northeastern Illinois Public Safety Training Academy. Course Syllabus 205

Dräger Pendula Medical Supply Units

Dräger-Tube pump accuro Dräger Tube Pump

Dräger PARAT 3260 Filtering Escape Device

Structural Firefighting Review: Fire Attack

Township of Cumru Fire Department 03/12/2008 Standard Operating Guidelines Page: 1 of 8 Section 15.05

Aquatic Leadership Catalogue September 2017 Labour Day 2018

SUBJECT: RAPID INTERVENTION CREW (RIC) SOG DATE ADOPTED: OCTOBER 18, 2012 REVISED: PAGES: 7

Dräger X-plore 3500 Half Mask

94 TH ANNUAL. FIre college. June 7, June 10, IllInoIS FIre ServIce InStItute University of illinois Urbana-Champaign

SHIPPENSBURG FIRE DEPARTMENT STANDARD ADMINISTRATIVE GUIDELINE

Dräger X-plore Rd40 Filters Filter

TESTING SKILLS PORTABLE FIRE EXTINGUISHERS

Ventilation Practices and Evidence-Based Research. By: John Paul Jones, Fire Chief KCKFD

TACTICAL VENTILATION Graeme Bowser, Tyne & Wear Fire Brigade, U.K.

Dräger Saver PP Compressed Air Escape

**ALL SHADED SKILLS MUST BE SIGNED OFF BEFORE LIVE FIRE TESTING MAY OCCUR**

Dräger X-plore 1300 Particle Filtering Face Piece

FREDERICK COUNTY/WINCHESTER FIRE AND RESCUE DEPARTMENTS BASIC FIRE ACADEMY #15 CERTIFICATION COURSE AUGUST 2015 APRIL 2016

Dräger CDR 4500 Full Face Mask

T A C T I C A L T R A I N I N G M O V E A B L E W A L L S Y S T E M S

Dräger Secor 7000 Diving Equipment and Systems

Transport ventilation without compromise DRÄGER OXYLOG 3000 PLUS

Dräger Bodyguard 7000 Warning Device

APPLCATIONS OF POSITIVE PRESSURE VENTILATION DURING AIRPORT AND ARFF INCIDENTS. Leroy B. Coffman III, Tempest Technology Corporation, USA

Dräger PAS AirPack 1 Compressed Air Breathing Apparatus

Dräger X-plore 9000 and PAS X-plore Airline breathing equipment

Improving RIT Operations

Volunteer Firefighter Applicant Information Package

Rapid Intervention Crews. 11 Skills Total

Dräger OCEANUS 140 Mobile Compressor

Rio Hondo College Basic Fire Academy Class 83 Schedule

Transcription:

Dräger Swede Survival System Phase 1 Flashover Development Observation With today s improved fire prevention methods, firefighters have fewer opportunities to gain first-hand experience of fighting live fires. The proven Swede Survival Phase 1 System trains firefighters to recognize conditions that lead up to a deadly flashover event and learn techniques to delay this phenomenon in a controlled, repeatable setting. D-37049-2015

02 Dräger Swede Survival Phase 1 System Benefits First-hand flashover development experience With today s improved fire prevention methods, firefighters have fewer opportunities to gain first-hand experience of fighting live fires. The proven Swede Survival Phase 1 System trains firefighters to recognize conditions that lead up to a deadly flashover event and learn techniques to delay this phenomenon in a controlled, repeatable setting. Class A Swede Survival Systems combine purpose-built training units with Dräger-certified instructional programs that train firefighters on fire behavior. As a result, you can continually build the capabilities and confidence of firefighters. At Dräger, we believe in a progressive learning process when teaching the characteristics of fire. Our instructional program can be traced to the multi-phased live fire training program developed by the Swedish Rescue Services Agency in Skovde, Sweden. Two compartment design creates a safe learning environment The wood-fueled Phase 1 system is essentially a laboratory where firefighters can closely observe fire behavior and learn to recognize the warning signs of a flashover. The upper compartment is the burn chamber. The observation level, which is 3 feet below the fire floor, gives firefighters a safe vantage point for observing the stages of fire as it progresses to flashover. This proven system is also designed to reinforce the proper use of personal protective equipment (PPE) and teach methods for testing and cooling the environment to delay the onset of a flashover. Rugged construction for long-term use With proper maintenance, Phase 1 systems have been known to withstand more than 1000 training sessions. If the burn chamber eventually becomes unstable due to heavy use, it is designed to be replaced, continuing the service life of the unit. The walls and ceiling of the burn chamber and walls of the observation chamber are lined with high temperature insulation material that is protected behind a seal-welded layer of 11-gauge steel. This protects the structural integrity of the container from the grueling temperature swings the container will undergo. The burn chamber includes a baffle system to control the heat and gases and is designed for sheets of Oriented Strand Board (OSB) to be placed along the walls, ceiling, and doors.

Dräger Swede Survival Phase 1 System 03 Real fire scenarios provide real-world experience The Swede Survival Phase 1 System is an indispensable component to any fire training curriculum because it allows participants to witness real fire characteristics under the supervision and direction of certified instructors. Flashover is considered to be one of the most dangerous fire phenomena a firefighter can experience. The instructors will demonstrate the fire characteristics that lead up to a flashover, including: Rollover Changing smoke conditions Thermal layering Heat build-up Participants will learn to recognize these conditions and how to address them to delay the onset of a flashover gaining valuable seconds for escape, while minimizing risk in the area of the fire. Two-day instruction certification workshop The Dräger Swede Survival Phase 1 System includes a two-day train-the-trainer workshop. This workshop is conducted by instructors who have extensive experience training various evolutions in the Dräger Swede Survival Systems. This training and certification process ensures that your instructors become thoroughly familiar with the safe and effective use of the training system. Classroom preparation provides a foundation of knowledge Included in the training is a 4-hour classroom session designed to deliver an extensive background on flashover conditions and fully prepare the participants for the subsequent real fire observation in the flashover chamber. Before entering the chamber, participants will have a comprehensive understanding of the design and purpose of the flashover container, simulation techniques, safety standards, and detailed training expectations. Participants receive expert instruction on firefighter roles during the actual observation exercise and what tools will be used during the simulation including nozzle techniques and proper use of thermal imaging cameras to assess the fire. Every trainee gets to practice as an instructor during the practical training. A mandatory test at the conclusion of the classroom session verifies that participants are prepared for the observation segment of the training. Training on methods of tear-down and set-up for subsequent evolutions are also part of every session all are included with purchase of a Swede Phase 1 system. Swede Phase 1 flashover training is designed to meet Job Performance Requirements listed in NFPA 1001 Firefighter 1 directives.

04 Dräger Swede Survival Phase 1 System The system includes 20-foot long observation chamber 10-foot long burn chamber 2-day training course for up to 10 instructors Instructor manuals and standard operating procedures (SOPs) Instructors receive Certification to Instruct the Dräger Curriculum upon completion Training course includes Certified instructors Ignition sources Fire behavior Formation of fire gases Fire control Container operations Hydration Heat stress SCBA and safety equipment training Thermal imaging camera usage Heat stress management Recognition of pre-flashover conditions Smoke and ventilation exercises Nozzle techniques Container management Overall safety Available options Mobile structure Custom paint colors and logos Emergency vent hatch in burn chamber Replacement burn chamber Temperature monitoring

Dräger Swede Survival Phase 1 System 05 Details D-37053-2015 D-31378-2011 Certified instructors teach real fire scenarios. D-29427-2015 D-37054-2015 Thermal layering, as observed in the chamber. D-1946-2016 D-1964-2016 Hinged, non-latching entry/exit door. Dräger UCF 9000 thermal imaging camera inside the Phase 1 system. Burn chamber with baffle system. The overhaul platform facilitates loading and overhaul. D-9131-2016 D-9077-2016 D-58675-2012 D-1297-2009 D-50153-2015 D-11442-2016 The Phase 1 is available as a fixed or mobile training unit. When trailer-mounted, the mobile Phase 1 system can be transported to satellite locations, maximizing training flexibility. Up-close observation from a safe vantage point. Preparing the burn chamber for a training evolution. All of our instructors are professional fire fighters with many years of experience operating the Dräger Swede Survival Systems within their own departments and at on-site classes for Dräger. Proper use of a thermal imaging camera to assess the fire is included in the training.

06 Dräger Swede Survival Phase 1 System ST-9330-2007

Dräger Swede Survival Phase 1 System 07 Related Products Phase 2: Interior Attack The Dräger Phase 2 system builds on the principles learned in Phase 1. Trainees take a more active roll in recognizing the room's fire condition, advancing a hose line, applying nozzle patterns, and ventilating fire gases through hydraulic ventilation methods. Phase 3: Backdraft Development The Dräger Phase 3 system is a demonstration system only. Students observe fire behavior and smoke conditions prior to backdraft. Phase 4: Garage The Dräger Phase 4 system consists of two 40-foot containers that have been put together with the center wall removed, providing a more realistic room size fire floor. This system teaches basic tactics, rescue, suppression, and ventilation techniques. Phase 5: Multi-story, Multi-fire The Dräger Phase 5 Multi-story system combines the unique construction of the enclosure and the training curriculum to gain tremendous insight into complexities inherent in multi-story, multi-fire involved structural fire situations. D-1298-2009_fre D-1295-2009_frei D-1300-2009_frei D-1296-2009_frei

08 Dräger Swede Survival Phase 1 System Phase 5 Modified: Multi-story, Multi-fire The Dräger Phase 5 Modified system expands on the standard Phase 5 training by including a double-wide burn chamber, four cold containers, a flat roof, a Denver Drill prop, and angled ventilation. The Phase 5 Modified system can be further enhanced with a number of optional props to expand the possible training scenarios. D-1985-2016 Phase 6: Interior Hallway The Dräger Swede Phase 6 simulates a hotel or apartment building fire and provides training for fire attack, smoke conditions, search and rescue, and hose handling through the main corridor. D-37059-2015 Technical Data Grade A containers High performance insulation 16-guage steel exterior 11-gauge sheet metal covering insulation 5/16" chain on walls, ceiling, and doors of burn area to hold Class A materials Ventilation system Concrete paving to line floor of burn area Crib fire drum Side entry doors without locks Access for hose line Posts for additional support of burn chamber Paint red oxide Cleanout/overhaul platform

Notes Dräger Swede Survival Phase 1 System 09

10 Dräger Swede Survival Phase 1 System Notes

Notes Dräger Swede Survival Phase 1 System 11

12 Dräger Swede Survival Phase 1 System Notes Not all products, features, or services are for sale in all countries. UCF is a trademark of Dräger. 90 46 908 16.06-3 HQ PP Subject to modifications 2016 Drägerwerk AG & Co. KGaA CORPORATE HEADQUARTERS Drägerwerk AG & Co. KGaA Moislinger Allee 53 55 23558 Lübeck, Germany www.draeger.com Customer Service: USA +1 800-4DRAGER (+1 800-437-2437) CANADA +1 877-DRAGER1 (+1 877-372-4371) Technical Service: USA +1 800-4DRAGER (+1 800-437-2437) Locate your Regional Sales Representative at: www.draeger.com/contact