Energy Performance Data for Krestmark Windows

Similar documents
Residential Energy Tax Credit

California Efficiency Standards: Progression to Zero Net Energy Buildings. Martha Brook California Energy Commission

FEATURES. Welded Sash and Main Frame. Swiggle or DuraSeal Spacer System on Fixed Units. 3-1/4" Frame Depth. True Sloped Sill. Integral J Channel

ADVANCING NATURAL GAS IN THE MULTIFAMILY BUILDINGS MARKET

APPENDIX P U.S. EPA WARM MODEL OUTPUT

U-Factor, SHGC & VT Simulated Values with SuperLite II-XL and GPX Framing by SAFTI FIRST

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. (Revised) Rendered to: NORTH EAST WINDOWS, USA, INC.

The Regional Greenhouse Gas Initiative: Compliance with EPA s Clean Power Plan

Apprentissage et Local VÉlo pour Offrir une Liberté de mobilité Econome en énergie

Building Planning PART. Chapter 3. Chapter 3. Building Planning. Climatic and Geographic Design Criteria C

Impacts of CO2 Restrictions on Indiana Electricity Prices

Traffic Impact Analysis (TIA) Process and Procedures Manual. September 2017

Gas Space Convection Effects on U-values In Insulating Glass Units

Manual S Compliance Report Entire House

Oregon Global Warming Commission

Taurus 4250 Series Exceptional quality, uncompromising safety TAURUS COLLECTION. The ultimate choice in efficiency, safety and quality

Electricity Price Impacts from CO2 Restrictions

Parallel Workshop: Avoid

CYCLIC PERFORMANCE PER ASTM E 330 TEST REPORT. Rendered to: TRUSEAL TECHNOLOGIES, LTD. PRODUCT TYPE: Fixed Window

TABLE OF CONTENTS International Racquetball Federation officially approved specifications. Copyright 01/13/1983; rev.

Action plan to promote local mobility in North Rhine-Westphalia (Germany)

Hydrogen Plant Project

Innovation Electrical Industry

Review of the Bulgarian legislation in the field of energy efficiency of buildings

Applied Compression s nitrogen generator packages offer users a cost-effective alternative to costly bottled nitrogen.

RESIDENTIAL AND COMMERCIAL REGULATORS FOR ABNORMAL OPERATING CONDITIONS (AOC) WITH 3 FOOT CLEARANCE INSTALLATION REQUIREMENTS.

SUSTAINABILITY INITIATIVES BY STUDENT ORGANIZATIONS FUNDING PROPOSAL $42,940 TBD $42,940

TOWARDS A BIKE-FRIENDLY CANADA A National Cycling Strategy Overview

OS2 F R A M E S E R I E S

Getting the Most From Your Diagnostic Equipment

First Mile, Last Mile: Plans for all Shapes and Sizes. Hannah Lindelof, Principal Planner San Francisco Bay Area Rapid Transit September 18, 2017

The Supplement Checker App A critical tool for more responsible supplement use in sports. Herman Ram inado Workshop, Lausanne, March 20, 2018

Argonomics. Low emissivity coatings Argon gas fills Warm edge design FIGURE 1 ADD ARGON ADD INTERCEPT SPACER ADD SINGLE STACK LOW E COATING

Draft Greater Sydney Region Plan

Energy Efficiency in California Some Possible Lessons for Ontario 20 March 2006

IGUMA - IGU Design Limitations

ASTM E1886 and ASTM E1996 TEST REPORT. Report No.: E Rendered to: 3M COMPANY St. Paul, Minnesota 55144

QUANEX BUILDING PRODUCTS TEST REPORT

Country Residential Lots from 1 Acre PLUS! TEXAS Country Living at it s VERY BEST! Builder: Phone

Fabric and Elastomer Expansion Joints. System solutions for reliable connections in plant engineering and construction.

TRAC. March 2, Mayor Gayle McLaughlin and City Councilors City of Richmond P.O. Box 4046 Richmond, CA 94804

Borough of Danville, PA Traffic Calming Program Guidelines

Young Researchers Seminar 2009

Evidence of Performance. Class 4. Class 5A. Class C5 / B5. Test Report No PR01. ift Rosenheim

Location and Avoidance of Underground Apparatus

This chapter describes the proposed circulation system and transportation alternatives associated with

al qadisiya, kuwait city sustainable urban retrofit and design + ali irani, andré pina, katie gertz, nathaniel jones, nelson soares

Joint Response to the Department for Transport Consultation on the Station Champions Report on Better Rail Stations. February 2010

Bike Rack Occupancy on the University of North Texas Campus

Product information VELUX INTEGRA flat roof window CVP

Fortified For Safer Living

WHITE PAPER: TRANSIT SERVICE FOR SOUTH SHAGANAPPI

Bicycle Parking Guidelines: Campus Accomodations. Campus parking 4/9/2013. An APBP Webinar Series

Results of Field Measurements and CONTAM Simulation. Building Science

Appendix D: Program Level Savings, Costs and Cost-Effectiveness

Area of existing house. Gross Flr. area excluding parking. (+1,657 basement) Gross Flr. area inc. covered parking & accessory bldg.

Public Comment Meeting Geary BRT Project Draft Environmental Impact Statement/Report

2 COUNTY OF SUFFOLK STATE OF NEW YORK X 4 HISTORIC PRESERVATION COMMISSION

Less bars, more light Maxilite Aluminium Roof Lanterns

P STYLE 6 LH 5 RH 4 LRH

australian cement industry Statistics 2012

APPROVE A RESOLUTION ADOPTING A COMPLETE STREETS POLICY

LANTw17 - SQA Unit Code H2RX 04 Prepare for, and agree, emergency treework operations

The transition to sustainable energy

United States Department of the Interior

OC Healthy Communities Forum. The proportion of the population that live within a half mile of a major transit access point.

Building Materials Forecasting Service. Executive Summary: Q2 2010

Pressure Strength Test Requirements for Hermetic Refrigerant Compressor Housings Using Fatigue Analysis

Water Management Residential Podium Construction BSC Experts Session Overview. Overview

Campus Development Committee Meeting

CYCLING & HEALTH. Randy Rzewnicki, PhD, Brussels, September 2013

Fremtidsrettede prosjekter ved SMS

Climate Change & India

4. ENVIRONMENTAL IMPACT ANALYSIS 9. TRANSPORTATION AND TRAFFIC

AMATS Complete Streets Policy

CENTRAL HUDSON GAS & ELECTRIC CORPORATION CASE 17-E- & 17-G- EAM PANEL SCHEDULE OF EXHIBITS

Process Control for Additive Manufacturing. Lesson 3 Measurement & Control of Heat Input

Linking Land Use & Transportation in Minneapolis

Geometric Design Tables

Institute for Transportation and Development Policy: Key Latin American Initiatives

Key Humanitarian and Development Trends

Economic Contribution of Off-Highway Vehicle Recreation in Colorado. Executive Summary Season. A joint cooperation report

Overview EUSDSG3.6. Gas tightness testing and direct purging

f. Tournament Production Regulations 1. National Event Brochures a. 2. National Recognition a. 3. National Partner Recognition a.

FILE - RE CAULKING WINDOWS AND DOORS EBOOK

Layout Guidelines. Overview

Progress with the Road Investment Strategy

Turn down your thermostat by two degrees. We invite YOU to join the Thermostat Challenge! February 20 26, 2017

Bicycle and Pedestrian Access in Transit Oriented Developments. Bruce Wright Chairman, Fairfax Advocates for Better Bicycling April, 2009

THE WELFARE OF ALL MONTREAL RESIDENTS REQUIRES THAT THE CAVENDISH BOULEVARD EXTENSION BE BUILT NOW

F-08 HIGH-PRESSURE HOSE USED IN CO2 SYSTEM

RESOLUTION NO A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF MENLO PARK ADOPTING A COMPLETE STREETS POLICY

6.0 ENGINEERING. Build Anything Better. REPRINTED 2017

Vessel Traffic Service. Functions and responsibilities. Speaker - Ivan Gotovchitc Head of RVTS

EN1279 part 3 assessment of insulating glass: IGU with Duralite sealant

INDEPENDENT TESTING OF SPARKLIKE LASER NON-DESTRUCTIVE INSULATING GLASS GAS FILL ANALYZER

Guidelines for Pressure Boundary Bolted Flange Joint Assembly

AMERICANS WITH DISABILITIES ACT TRANSITION PLAN LEON COUNTY FOR CURB RAMPS AND SIDEWALKS DEPARTMENT OF PUBLIC WORKS. 1 P age

Favorable factors for bicycling and walking investments & plan implemtation. Road Map for Success

DOE Climate Change Proposals

Transcription:

Energy Star is a joint program of the U.S. Environmental Protection Agency and the U.S. Department of Energy helping us all save money and protect the environment through energy efficient products and practices. Results are already adding up. Americans, with the help of Energy Star, saved enough energy in 2008 alone to avoid greenhouse gas emissions equivalent to those from 29 million cars all while saving $19 billion on their utility bills. The Energy Star performance criteria for windows and doors is different depending on what region of the country the product is being tested. Below is the Energy Star climate map and corresponding requirements for each region. Krestmark manufactures vinyl windows that, with several glazing options such as Argon gas, meet energy star guidelines in all regions. Energy Star Qualification Criteria for Residential Windows Climate Zones - U.S. U-Factor SHGC Northern** <0.30 Any Northern** =0.31 >0.35 Northern** =0.32 >0.40 North-Central <0.30 <0.40 South-Central <0.30 <0.25 Southern <0.40 <0.25 ENERGY STAR Residential Windows Version 6.0 specification, effective 1/1/15; **Northern Zone prescriptive, effective 1/1/16. Performance Data for Krestmark Vinyl 220 Replacement Window 3/4" OA Insulated U-Factor SHGC VT U-Factor SHGC VT Clear air no grilles 0.47 0.61 0.65 0.47 0.66 0.69 Clear air w/grilles 0.47 0.55 0.58 0.47 0.60 0.62 Clear argon no grilles 0.45 0.63 0.65 0.45 0.66 0.69 Clear argon w/grilles 0.45 0.56 0.58 0.45 0.60 0.62 E66 LoE air no grilles 0.33 0.22 0.51 0.31 0.23 0.54 E66 LoE air w/grilles 0.33 0.20 0.46 0.31 0.21 0.49 E66 LoE argon no grilles 0.29 0.22 0.51 0.28 0.23 0.54 E66 LoE argon w/grilles 0.29 0.20 0.46 0.28 0.21 0.49

Performance Data for Krestmark Vinyl 220 Replacement Window Dual 3/4 OA Insulated U-Factor SHGC VT Clear air no grilles 0.47 0.63 0.66 Clear air w/grilles 0.47 0.57 0.59 E66 LoE air no grilles 0.33 0.22 0.52 E66 LoE air w/grilles 0.33 0.20 0.46 E66 LoE argon no grilles 0.30 0.22 0.52 E66 LoE argon w/grilles 0.30 0.20 0.46 Clear air no grilles 0.48 0.63 0.65 0.48 0.65 0.68 Clear air w/grilles 0.48 0.56 0.58 0.49 0.58 0.61 E66 LoE air no grilles 0.33 0.22 0.51 0.32 0.24 0.54 E66 LoE air w/grilles 0.33 0.20 0.46 0.32 0.22 0.49 E66 LoE argon no grilles 0.29 0.22 0.51 0.27 0.23 0.54 E66 LoE argon w/grilles 0.29 0.20 0.46 0.27 0.21 0.48 Dual 5/8 OA Insulated U-Factor SHGC VT Clear air no grilles 0.48 0.63 0.66 Clear air w/grilles 0.48 0.57 0.59 E66 LoE air no grilles 0.33 0.23 0.52 E66 LoE air w/grilles 0.33 0.21 0.46 E66 LoE argon no grilles 0.29 0.22 0.52 E66 LoE argon w/grilles 0.29 0.20 0.46

Clear air no grilles 0.47 0.63 0.65 0.47 0.65 0.68 Clear air w/grilles 0.47 0.56 0.58 0.47 0.58 0.61 Clear argon no grilles 0.45 0.63 0.65 0.45 0.66 0.69 Clear argon w/grilles 0.45 0.56 0.58 0.45 0.60 0.62 E66 LoE air no grilles 0.32 0.22 0.51 0.31 0.23 0.54 E66 LoE air w/grilles 0.32 0.20 0.46 0.31 0.21 0.49 E66 LoE argon no grilles 0.29 0.22 0.51 0.27 0.23 0.54 E66 LoE argon w/grilles 0.29 0.20 0.45 0.27 0.21 0.49 Performance Data for Krestmark Vinyl 250 Series Windows Casement/Awning/Picture Picture Window Clear air no grilles 0.41 0.53 0.55 0.46 0.70 0.73 Clear air w/grilles 0.41 0.48 0.49 0.46 0.63 0.66 E66 LoE air no grilles 0.29 0.19 0.43 0.29 0.24 0.57 E66 LoE air w/grilles 0.29 0.17 0.39 0.29 0.22 0.52 E66 LoE argon no grilles 0.26 0.18 0.43 0.25 0.24 0.57 E66 LoE argon w/grilles 0.26 0.17 0.39 0.25 0.22 0.52 Performance Data for Porter-lite Series 400 MFG by Krestmark Clear air no grilles 0.49 0.66 0.69 0.47 0.72 0.75 Clear air w/grilles 0.49 0.59 0.62 0.47 0.65 0.68 E66 LoE air no grilles 0.32 0.23 0.54 0.30 0.25 0.59 E66 LoE air w/grilles 0.33 0.21 0.48 0.31 0.23 0.53 E66 LoE argon no grilles 0.27 0.23 0.54 0.25 0.25 0.59 E66 LoE argon w/grilles 0.28 0.21 0.48 0.26 0.23 0.53

Performance Data for Porter-lite Series 400 MFG by Krestmark Dual 5/8 OA Insulated U-Factor SHGC VT Clear air no grilles 0.48 0.66 0.69 Clear air w/grilles 0.48 0.59 0.62 E66 LoE air no grilles 0.32 0.23 0.54 E66 LoE air w/grilles 0.32 0.21 0.48 E66 LoE argon no grilles 0.29 0.23 0.54 E66 LoE argon w/grilles 0.29 0.21 0.48 Performance Data for Krestmark Impact Vinyl 4000 Series Clear air no grilles 0.48 0.62 0.67 0.47 0.67 0.73 Clear air w/grilles 0.48 0.56 0.60 0.48 0.61 0.66 E66 LoE air no grilles 0.33 0.23 0.53 0.31 0.25 0.57 E66 LoE air w/grilles 0.35 0.21 0.47 0.33 0.23 0.52 E66 Argon no grilles 0.28 0.23 0.53 0.26 0.25 0.57 E66 Argon w/grilles 0.29 0.21 0.47 0.27 0.23 0.52 Performance Data for Krestmark Impact Vinyl 4000 Series Dual 3/4 OA Insulated U-Factor SHGC VT Clear air no grilles 0.48 0.62 0.67 Clear air w/grilles 0.48 0.55 0.60 E66 LoE air no grilles 0.33 0.23 0.53 E66 LoE air w/grilles 0.35 0.21 0.47 E66 Argon no grilles 0.28 0.23 0.53 E66 Argon w/grilles 0.30 0.21 0.47

Performance Data for Krestmark Aluminum 100 Series Windows Clear air no grilles 0.64 0.69 0.71 0.59 0.73 0.76 Clear air w/grilles 0.64 0.63 0.64 0.59 0.66 0.69 E66 LoE air no grilles 0.49 0.25 0.56 0.43 0.26 0.60 E66 LoE air w/grilles 0.49 0.23 0.50 0.43 0.24 0.54 E66 LoE argon no grilles 0.44 0.24 0.56 0.38 0.26 0.60 E66 LoE argon w/grilles 0.44 0.22 0.50 0.38 0.23 0.54 Performance Data for Krestmark Aluminum 150 Series Windows Clear air no grilles 0.67 0.68 0.70 0.59 0.73 0.76 Clear air w/grilles 0.67 0.61 0.63 0.59 0.66 0.69 E66 LoE air no grilles 0.52 0.25 0.55 0.43 0.26 0.60 E66 LoE air w/grilles 0.52 0.22 0.49 0.43 0.24 0.54 E66 LoE argon no grilles 0.48 0.24 0.55 0.38 0.26 0.60 E66 LoE argon w/grilles 0.48 0.22 0.49 0.38 0.23 0.54 Performance Data for Krestmark Aluminum 175 Series Windows Clear air no grilles 0.65 0.68 0.71 0.59 0.73 0.76 Clear air w/grilles 0.65 0.62 0.63 0.59 0.66 0.69 E66 LoE air no grilles 0.50 0.25 0.56 0.43 0.26 0.60 E66 LoE air w/grilles 0.50 0.23 0.51 0.43 0.24 0.54 E66 LoE argon no grilles 0.45 0.24 0.56 0.38 0.26 0.60 E66 LoE argon w/grilles 0.45 0.22 0.51 0.38 0.23 0.54