Operation Manual Air Saver Unit ASV5000 Series

Similar documents
Air operated valve. VGA342R Series

Pilot Check Valve: Metal Body Type

Related Products: Auto Drain Valve. Model/Specifications. Model

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

No.IL02-OM00011-A PRODUCT NAME LOCK UP VALVE. MODEL/ Series IL201 IL211

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6

Cautions : 1. Clogging of the element raises resistance to exhaust, thus lowering the

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

(1) Type (2) Thread size (T) (3) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R)

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Doc. No.SYJ300-OMO0002-A. Air Operated Valve PRODUCT NAME. SYJA300 / SYJ3000 Series MODEL/ Series

Series AS-FPQ/AS-FPG. Speed Controller with One-touch Fitting for Clean Room. Speed controllers for clean room use

WW-720. Pressure Reducing Control Valve

Direct Operated Precision Regulator Modular Style. Standard Specifications

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

Series ZFC. Air Suction Filter In-line Type with One-touch Fittings

Series IRV1000/2000/3000

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

WW-720. Pressure Reducing Control Valve

VOLUME BOOSTER RELAYS YT-300 / 305 SERIES

(1) Type (2) Cylinder dia. (3) Gripper action : Single-acting closing gripper (normally open) (4) Holder type

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

Interface Devices, Inc. Hydraulic Mini Mule

WW-730. Pressure Sustaining/Relief Control Valve

OPERATING AND MAINTENANCE MANUAL

PRODUCT NAME. Main Line Filter. MODEL / Series / Product Number

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

Hand Valve Series. Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Control Open/Close for Air Supply.

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

30% (SMC comparison) Silencer. New. New. The M5 silencer is now added! The resin silencer is now a more compact size! Series AN.

PVC Quick Drain Valve

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

How to Order. Body size. Pressure: 2 MPa. Pressure increase ratio 0 Twice. Symbol. Thread type. Body size

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

Doc. No.VFR3000-OMH0005-B. 5 Port Air Operated Valve PRODUCT NAME. VFRA3000, 4000 Series MODEL/ Series

(1) Name of tube (2) Tube dia. (O.D./I.D.) (3) Tube length. (4) Tube color. Model UD0425. UD1290 O.D. I.D. (mm) UD1075 UD0860 UD

Pressure Relief 3 Port Valve New. Sonic Conductance 45% With the indicator window Step1. With locking holes

Series AMJ. Drain Separator for Vacuum

Push-In Fitting Type Silencer

Coiling Tube with Twist-Proof Fitting

Jacuzzi. J-CQ420 Cartridge Filter Installation and Operating Instructions

(2) Effective sectional area (no code for mini type) (3) Intake-side shape (no code for mini type) : Quick-fitting joint type : Taper pipe thread type

Filter-Regulator-Lubricator

Air Saver Unit An environmentally friendly solution to reducing air consumption. Catalog 0698P

Change Valve. Push-In Fitting Type Three-way Changeover Valve. Changeover Air Direction by 90. Lightweight and Compact Design.

Vacuum Saving Valve Series ZP2V How to Order ZP2V A5 03 Connection thread symbol for the pad Male thread connection Symbol Thread Applicable fixed ori

Installation & Maintenance Instructions TEC-11N TIMER. Analogue electronic timer 02/09

SF SERIES CNG COMPRESSOR MODEL HF-4MH. 4 Nm3/Hour Displacement OPERATION MANUAL

5 Port Air Operated Valve

Cautions : 1. Be careful when you release the Stop Fitting with some internal pressure

Air Saving Valve. Pressure Valve Flow Valve

Index Table. Model 794. Installation, Operating and Maintenance Instructions

INSTALLATION COMMISSIONING, OPERATION & MAINTENANCE MANUAL

Push-In Fitting Type Pressure Gauge

OPERATION MANUAL NTF-15

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

Cautions : 1. The gauge orientation on the GPU and GPM types can be changed by using

AIR COMPRESSOR. Failure to follow all instructions as listed below may result in electrical shock, fire, and/or serious personal injury.

Pressure booster combination DPA-CRVZS. Operating instructions a [ ]

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

170-SJ Feed UnitTM 470-SJ Feed UnitTM

BUTTERFLY VALVES Series 800

Process Pump. Series PAF3000/Series PAF5000

SeriesTRBU. Flame Resistant (Equivalent to UL-94 Standard V-0) FR Double Layer Polyurethane Tubing

Pulse Blow Series Offers Energy Savings for Air-blowing Procedures

EXH. Specifications. Descriptions. Min. working pressure MPa

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

LMU100/200 Series. Standard Specifications

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

5 Port Solenoid Valve

HANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to:

OWNER S TECHNICAL MANUAL

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Tube Cutter with Measuring tape built-in

PN-DR. Pneumatic Direct-acting Pressure Reducing Valve for Steam and Air. Copyright 2018 by TLV CO., LTD. All rights reserved

The plastic bowl guard does not corrode. The draining method is selectable between the push type and the auto drain type.

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

(1) Type. (2) Tube dia. (ød) : ø8mm (ø5/16in.) (3) Thread size (T) (4) Specification. Fluid medium. Air, water * 1, * 2, * 3 Max. operating pressure

reduces flow setting time and setting errors!

Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Operating and maintenance manual Filter and reducing station Series / 1.0

OPERATION and MAINTENANCE Guide

OPERATION MANUAL NTF-60 Plus

Operation & Service Manual

Model GPR Primary Pressure Regulating Valve. Instruction Manual

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

Insert Ring. Protection Ring from Tube Deformation. Protect tubes from deformation. Ultra soft tube is connectable to Fitting.

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

Pre-filter for Brushless Blower Instruction Manual

Oxygen Usage Best Practice Guide

200 PSI FAST-FILL AIR SOURCE KIT

Float Operated Level Controllers

200 PSI COMPRESSORS - MODEL NUMBERS

100C Air Compressor Kit

200 PSI HIGH-FLOW AIR SOURCE KIT

Power Valve: Precision Regulator. High precision, large capacity relief regulator

IMPORTANT SAFETY INSTRUCTIONS

Transcription:

9IM-V066-b Operation Manual Air Saver Unit ASV5000 Series Thank you for your choice of Kuroda Pneumatics LTDs product on this time. Please read this operation manual carefully and use the product correctly. Keep this operation manual in case questions arise about this product in the future. If this operation manual becomes unreadable or parts of it are missing, consult our distributors or Kuroda Pneumatics Ltd. sales offices.

9IM-035-b Contents For safety use Warning P2 P2 1. ASV5000 Series general information P3 2. Ordering instructions P3 3. Specifications P4 4. Dimensions P4 5. How to adjust pulsed air cycle P4 6. Notes for usage P5 7. Problem & Trouble shooting P6 8. Disassembling and maintenance P6-1 -

9IM-035-b For Safety Use Be sure to read the following instructions before use. The following safety precautions are provided to prevent damage and injury to personnel and to provide instructions on the correct usage of this product. These precautions are classified into 3 categories: CAUTION, WARNING and DANGER according to the degree of possible injury or damage and the degree of impendence of such injury or damage. Be sure to comply with all precautions along with JIS B 8370(*1) and ISO 4414(*2), as they include important content regarding safety. Danger: Warning : Caution: Indicates an impending hazardous situation which may arise due to improper handling or operation and could result in serious personal injury or death. Indicates a potentially hazardous situation which may arise due to improper handling or operation and could result in serious personal injury or death. Indicates a potentially hazardous situation which may arise due to improper handling or operation and could result in personal injury or property-damage-only accidents. *1 JIS B8370 : General Rules for Pneumatic Systems *2 ISO 4414 : Pneumatic fluid power-general rules relating Never operate machinery nor remove the equipment until safety is assured. Before checking or servicing machinery and equipment, be sure to check that steps for prevention of dropping or runaway of the driven component have been completely taken. When removing the equipment, make sure that the above-mentioned safety measures have been done beforehand. Then turn off air supply and power to the system and purge compressed air in the system. When restarting machinery and equipment, check that proper prevention of malfunction has been provided for and then restart carefully. When using the pneumatic equipment in the following conditions or environments, take the proper safety measures and consult Kuroda Pneumatics LTD beforehand. Conditions and environments other than specified and outdoor use. Applications to nuclear power equipment, railroads, aircraft, vehicles, medical equipment, equipment connected with food and drink, amusement facilities and safety devices such as emergency interruption devices, clutch/brake circuits for a press and the likes. Applications which require extreme safety and will also greatly affect human and property. to systems. Warning The applicability of pneumatic equipment to the intended system should be judged by the pneumatic system designer or the personnel who determined specifications for such system. As operating conditions for products contained in this instruction are diversified, the applicability of pneumatic equipment to the intended system should be determined by the pneumatic system designer or the personnel who determined specifications for such system after conducting an analysis or testing as necessary. Before making a system, the system designer should thoroughly examine all specifications for such a system and also take into consideration the possibility of any trouble with the equipment. The pneumatic equipment should be handled by persons who have sufficient knowledge and rich experience. Inproper handling of compressed air will result in danger. Assembling, operation and maintenance of machinery using pneumatic equipment should be performed by persons who have sufficient knowledge and rich experience. - 2 -

1. General Information This product is a pulsed air generation unit with a built-in soft seal pneumatic valve. This product is mainly for reducing air consumption in air blowing applications. 2. Ordering Instructions ASV5000 -AA-04 1 2 3 1 Model No. 2 Voltage/Wiring 3 Port size ASV5000 (2-position, Single) AA:All air(no electrical wiring) No mark:without sub-base 04 :Rc1/2 <Circuit> 3. Specifications Model No. Unit ASV5000 Fluid - Non-lubricated air Port size - Rc1/2 Sonic speed conductance dm 3 /(s bar) 14.0 Critical pressure ratio - 0.45 Effective area (reference) mm 2 70 Ambient temperature Note 1) -5~50 Operating pressure range MPa 0~0.8 Pilot pressure MPa Note 2) 0.3~0.8 Max. frequency Hz 5 Weight g 830 Note 1) When ambient temperature of the unit goes below 5, complete dry air shall be supplied to prevent freezing. Note 2) ASV5000 series is a pilot operated unit. Therefore during air blow operation, pilot pressure should be more than 0.3MPa. Important Please be sure to supply more than 0.3MPa to pilot air supply port always. 3

4.Dimensions ASV5000-AA-04 Unit (mm) Pilot air supply port M5 Plug OFF time Adjustment needle Plug Port 4 Rc1/2 ON time Adjustment needle Port 1 Rc1/2 Threshold element Plug (Piping) Port 1 : Supply port (Compressor side) Port 4 : Outlet port (Blow nozzle side) Pilot air supply port (Mounting hole) Exhaust port (Port 3,5) Rc3/8 Plug 5. How to adjust pulse air cycle ON time Adjustment needle OFF time Adjustment needle Flow ON Time OFF Time Time ((Preparation for air supply)) 1) After piping to Air Saver Unit, fully close the ON time adjustment needle (clockwise rotation) and fully loose the OFF time adjustment needle (counter clockwise rotation) while the supply air is shut off. If fully loosed and tightened positions of adjustment needles are marked, it may later be convenient to use those marks as an indication of needle rotation. 2) If air is supplied to the supply port, air is output to the output port continuously. 4

3) Slowly loosen the ON time adjustment needle in CCW direction. A pulsed air blow of short OFF time will start. To adjust the ON/OFF duty, stop the rotating ON time adjustment needle at around 2 turns. 4) Next, adjust the OFF time by slowly tightening the OFF time adjustment needle in CW direction. The OFF time of the pulsed air blow will get longer. Stop rotating the OFF time adjustment needle at around 5 turns. A 2Hz and 50% duty pulsed air blow should be achieved. 5) Use the procedure of 4) as a starting point and make the frequency and duty adjustments required in your application by using ON time and OFF time adjustment needles. 6) Fix the adjustment position by tightening lock nuts on adjustment screws. Tighten (Clockwise) Loosen (Counter clockwise) Pulsed air cycle Slow Fast ON time adjustment needle Longer ON time Shorter ON time OFF time adjustment needle Longer OFF time Shorter OFF time *Adjust frequency of pulsed air to less than 5 Hz. If frequency of pulsed air is higher than 5 Hz, operation of all pneumatic circuit (logistic element) may become unstable. ((How to stop the operation of Air Saver Unit)) 1) Fully loosen ON time adjustment needle. 2) Fully tighten OFF time adjustment needle. Keep in mind that air blow may come out, even though, OFF time adjustment needle is fully tightened. 3) Cut the supply air to the Air Saver Unit. (Caution) When air blow is not used, be sure to cut air supply to the Air Saver Unit. Air blow may come out even the ON/OFF time adjustment needles are fully tightened. 6. Notes for usage a) Before piping Thoroughly flush the inside of each pipe to remove chips, coolant, dust, etc. b) Air quality 1) Fit an air filter with filtration of 5μm or finer. 2) Be sure to follow proper maintenance procedures of the compressor. Exhaust drain that is separated in filter. If drain gets into the compressed air, it may cause problems. If it is difficult to make drain management periodically, Kuroda Pneumatics LTD recommends setting up an air filter with automatic drain mechanism. 3) Be sure to take proper maintenance for a compressor. If sludge produced in compressor oil enters pneumatic equipment, it will cause operation failure of pneumatic equipment. Kuroda Pneumatics LTD recommends setting up a coalescing filter after a filter. c) Pneumatic circuit 5

This unit requires supply air for pilot port. To avoid malfunctions due to pressure drops, pilot air pressure must be more than 3MPa at all times. To avoid pressure drops during air blowing consider revising your piping, setting relatively higher pilot pressure, using tubes with proper diameter. Kuroda Pneumatics LTD recommends that the air for the blown air and pilot should be piped separately. d) Stopping the air blow Be sure to cut air supply to Air Saver Unit when air blow is not used. Blown air comes out even when the ON/OFF time adjustment needles are fully closed. e) Lubrication This product is designed for non-lubricated air. Do not lubricate. 7. Failure and Trouble shooting a) Failure and countermeasure Failure condition Cause Countermeasure The unit cannot be operated. Pilot air is less than 0.3MPa during operation. Adjust pilot air pressure properly. Operating frequency is getting slower. Valve part is contaminated with dust or sludge. Dust or high viscosity oil is trapped in the valve and it obstructs the spool. 1) Replace the product. 2) If an air filter is not used, use an air filter. 3) If problem is sludge, use a coalescing filter. 1) Replace the product. 2) If air filter is not used, use an air filter. Substantial air leakage is observed. From main valve part From base gasket Such as dust is caught inside of pneumatic circuit, and it blocks up the flow. Dust accumulated in the exhaust port, obstructing the air flow. Spool seal rings are damaged. Tightening torque for mounting screws is not enough to mount valve. Replace the concerned part. Clean up air mufflers or replace them. Replace the master valve. Tighten mounting screws to appropriate torque. 8. Maintenance and disassembly Regarding repair and maintenance, please consult Kuroda Pneumatics LTD. As a general rule, do not attempt maintenance or disassembly. If it is absolutely necessary to do maintenance work, keep the following points in mind. 1) Make sure that the actuators such as cylinders will not cause damage if they move. 2) Cut off electricity. 3) Cut off pneumatic pressure and exhaust air in the line. 4) Clean up the surroundings of the valve. 6

Caution Any attempt to repair and/or disassembling of the product by the user violates the warranty and Kuroda Pneumatics, Ltd. Does not take any responsibility for damage and injury caused by it. 7