ASTRA - DRY PIPE VALVES GROOVE/GROOVE

Similar documents
TECHNICAL DATA CAUTION

TECHNICAL DATA DELUGE VALVE, MODEL F-1 STRAIGHT THROUGH STYLE

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

Anti-flood device Model B-1

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

TECHNICAL DATA. Page 1 of 8. model f /2 (dn40) & 2 (dn50)

TECHNICAL DATA. Q = C v P S

Services Department for information concerning the use of the ACC-1 for use with dry pipe valves other than the Model DPV-1.

TECHNICAL DATA. Q= Cv S

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE. 4. TECHNICAL DATA Approvals:

Model DPV-1 Dry Pipe Valve External Resetting. General Description. Technical Data. Page 1 of 20 AUGUST 2018 TFP1020. Worldwide Contacts

GW DRY PIPE VALVE INSTALLATION & OPERATION 100mm (4 ) 150mm (6 )

TECHNICAL DATA. Dry 132a. October 1, 2008

TECHNICAL DATA. than the water inlet pressure to the concentrate

TECHNICAL DATA ACCELERATOR MODEL E-1

TECHNICAL DATA. Deluge Valves 218a. November 30, 2007 DELUGE VALVE MODEL F-1 STRAIGHT THROUGH STYLE 2-1/2 (DN65) - 8 (DN200)

Instructions for Installation, Operation, Care and Maintenance

TECHNICAL DATA. Deluge Valves 211a. November 30, 2007 DELUGE VALVE MODEL E-1 ANGLE STYLE 3 (DN80), 4 (DN100) & 6 (DN150)

Fire Protection Equipment

GENERAL DESCRIPTION MODEL RCW DRY SYSTEM CONFIGURATION. Technical Support Airpark Dr. Standish, MI 48658

Worldwide Contacts. End Connection

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA Q= C. Table 1 - Specifications

Technical Data. UL Listing is based on the following criteria:

Fire Protection Equipment

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

Features. Model EX Low Pressure Dry Pipe Valve System 2 (DN50), 2½ (DN65), 3 (DN80), 76 mm, 4 (DN100 ), 6 (DN150), 165 mm & 8 (DN200)

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH PNEUMATIC RELEASE

NOTICE The Model DPV-1 Dry Pipe Valves and

TECHNICAL DATA. Q = C v P S

Wet pipe low flow foam/water system

End Connection. Thread x Thread N/A N/A N/A N/A Flange x Flange N/A

1.0 - OPENING AND CLOSING THE DOOR

TECHNICAL DATA OBSOLETE

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

TECHNICAL DATA. System water supply pressure enters the priming chamber of the deluge valve (A.1) through the 1/4 (8 mm) priming line, which

Features. Model DDX-LP Dry Pipe Valve System 2 (50 mm), 2½ (65 mm), 3 (80 mm), 76 mm, 4 (100 mm), 6 (150 mm), 165 mm & 8 (200mm) Listings & Approvals

TECHNICAL DATA. Page 1 of 12

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7

TECHNICAL DATA. Table 1 - Specifications

Worldwide Contacts.

TECHNICAL DATA CAUTION

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

TECHNICAL DATA OBSOLETE

Model DDX-LP Dry Pipe Valve System 8 (200mm) Features. Differential latching clapper-type, lighweight, dependable construction.

DRY-PIPE, DELUGE, PREACTION VALVES & ACCESSORIES. Table of Contents

Features. Model DDX-LP Dry Pipe Valve System 4 (100mm), 6 (150mm) & 165mm Sizes

MODEL RCW DRY SYSTEM VALVE

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Data Sheet Issue A

GREIG FILTERS, INC. OPERATION MANUAL

FireLock NXT Dry Valve. System No. Submitted By Spec Sect Para Location Date Approved Date

FireLock NXT Preaction Valve with Series 798 Pneumatic/Pneumatic Actuator

MODEL RCW NON-INTERLOCK PREACTION SYSTEM

TECHNICAL DATA. the Viking Pilot Pressure Regulating Valve 1 Model A-1 Speed Control Assembly: OBSOLETE. the Viking Speed Control Assembly 1

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

TECHNICAL DATA OBSOLETE

INSTALLATION OPERATION MAINTENANCE

DESIGN DATA OBSOLETE. C. Inspections - It is imperative that the system be inspected and tested on a regular basis. See Inspection

Model: 43T. Bermad Pressure Relief Valve

Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

TECHNICAL DATA. Trimpac 244a. September 16, 2013

DelVal Flow Controls Private limited

SV5 Safety Valve Installation and Maintenance Instructions

TECHNICAL DATA. Trimpac 257a. September 16, 2013

Speed control assembly model A-1

Pressure Dump Valve Service Kit for Series 2300 Units

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E

Pressure Dump Valve Service Kit for Series 3000 Units

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

Instructions for Installation, Operation, Care and Maintenance

Installation Troubleshooting Maintenance Instructions Installation / Start-up

TECHNICAL DATA. Trimpac 256a. October 31, 2013

Serie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection

SALCO PRODUCTS, INC. PRESSURE RELIEF VALVE STORAGE, INSTALLATION, OPERATING, MAINTENANCE/TESTING, AND INSPECTION INSTRUCTIONS

Model DPV-1 Dry Pipe Valve, DN100 and DN150 Model ACC-1 Dry Pipe Valve Accelerator European Conformity Valve Trim, 16 bar. General Description

Bermad Model:

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

ROTATING DISK VALVES INSTALLATION AND MAINTENANCE 1. SCOPE 3 2. INFORMATION ON USAGE 3 3. VALVE TYPES 3 4. OPERATORS 5 5. VALVE CONSTRUCTION 6

Installation & Operation Manual Proven Quality since 1892

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

Data Sheet Issue A

756 Safety Relief Valves

3/8" Dr. Air Butterfly Impact Wrench

Code AWC20HP Air Compressor

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

Hydraulic Piston Accumulators

Crosby style JCE Safety Valve Installation, Maintenance and Adjustment Instructions CROSBY

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY PNEUMATIC RELEASE. 1. DESCRIPTION (Refer to Figures 1, 2 or 3.

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL

Transcription:

WORLDWIDE - SELLING OUR PRODUCTS IN OVER 20 COUNTRIES ASTRA - DRY PIPE VALVES GROOVE/GROOVE 4" / DN100 Document includes technical information for : ASTRA Dry Pipe Valves model E Trim configuration UL/cUL/FM Trim configuration UL/cUL/FM/LPCB Venus Fire Protection 4105 Portland blvd. Sherbrooke, Quebec, Canada J1L 1X9 venus-fire.com / sales@venus.ca t: 1-819-820-8000 / f: 1-819-820-8002

RESETTING THE ASTRA DRY PIPE VALVE 1. Close main controlling valve or post indicator to shut off water supply to sprinkler system. 2. Open valve 1 to drain sprinkler system. 3. Gong and electric valve may be shut off by closing valve 2. 4. Vent sprinkler system by opening 3/4" (19.05mm) inspector's test valve which is normally located at the top. 5. After system is thoroughly drained, remove cover plate 3 for resetting dry valve. 6. Raise clapper off seat and scoop out any scale or solid particles found in intermediate chamber, in the bottom of the valve air and water seats. Using a clean piece of cloth wipe the surface of the rubber seats on the swinging clapper, also the tin seats in the valve. Never apply grease, tallow, or any other substance to water or air seat. 7. Let bronze clapper down on its seat making sure that the rubber air ring presses evenly all around the air seat. 8. Put on cover plate 3 making sure that gasket is in good condition. Replace nuts and tighten evenly, all around. 9. Drip valves are found at low points (if any) on sprinkler piping. They would not be drained by previous operation open these valves for draining after removing plugs and close when water stops running 10. Close 3/4" (19.05mm) inspector's test valve, previously opened to vent system. 11. Replace sprinklers fused by fire. 12. Prime by opening valve 4 and slowly pour water into priming cup 5 until priming level is even with the cup. remove plug 7 in valve 6 which is normally open; after water stops running replace plug 7 and close valve 4 tightly. Water must not be allowed to stand above the priming water level. 13. Open valve 8 and pump air pressure into the system. When ten pounds (4.536 kg) pressure has been built up, open drip valve again to force water from low points of system. Close drip valves tightly and plug. 14. Pump the correct air pressure into the sprinkler system, then close valve 8 tightly. Make sure these is no leakage of priming water by the rubber air seat into drip cut 10 by observing automatic drain valve 9. Note: Never allow air pressure to drop below minimum limit, to safeguard against accidental tripping of dry valve. Air pressure required for sprinkler system should be calculated at approximately one (1) PSI of air for every six (6) PSI of water pressure. The air pressure should be maintained at approximately twenty (20) PSI above calculated air pressure, per NFPA-13. 15. Partly close valve 1- then open main controlling valve slowly, until water is heard flowing through drain valve 1, then close tightly and open controlling valve fully and seal. 16. To check water seat inside the dry pipe valve, look at the automatic drain valve 9, and make sure that no water is leaking into the drip cup 10. 17. Open automatic drain valve 9 to be sure no water remains in pipe to alarm devices, then close. 18. Valve 2 should now be opened. INSPECTION AND MAINTENANCE A minimum of two people should be familiar with the sprinkler system but at least one should be held responsible for its proper maintenance 1. Test main riser for water to make sure dry pipe valve is not water columned. Water should be up to but not above the level of valve 6. 2. Close main control valve. Open main drain valve 1. 3. Close valve 6 and remove plug 7. Open 6 to drain water which is above the level of this valve. Replace plug 7 and open valve 6. Check air pressure according to NFPA-13. Close drain valve 1 and the open main control valve. 4. Air pressure must be maintained and checked weekly under normal conditions. During freezing weather it should be checked daily. Check valve 8 in the fall before freezing weather sets in to assure a tight seat. 5. Alarm devices may be tested occasionally without tripping the dry pipe valve by opening valve 11 if weather allows. 6. Drip valves or drum drips should be drained before freezing weather sets in and occasionally during winter. Note: We also recommend at least an annual inspection by qualified inspectors of the complete fire protection system. Many times defects may be detected during inspection and repairs made before they develop into major troubles might mean the protection would be off in your plant for several days. 1/4

4" ASTRA DRY VALVE - GR/GR RATED 175 PSI WORKING PRESSURE DESCRIPTION AND OPERATION The ASTRA 4" Dry Pipe Valve is essentially a differential check valve. The bronze clapper carries two rubber gaskets. The larger (air) gasket is rubber and seats against pure tin. The smaller (water) gasket is a specially designed rubber disc, which also seats on pure tin. These seats are proportioned so that 1 pound (.454 kg) of air pressure will hold back approximately 6 pounds (2.72kg) of water pressure. When the air pressure on the surface of the priming water is relieved by the opening of a sprinkler, the upward pressure of the water underneath the water gasket causes the clapper to lift, the chamber instantly fills and sounds the alarm. The water pressure acting on the entire surface of the clapper pushes it over to the wide open position and thus leaves a passage for the water to the sprinkler system. Parts List ITEM Part No. DWG No. DESCRIPTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 D-132 D-2 ON-12A D-268 D-47 DPVB 4004 DPV 4031 DPV 4033 DPV 4032 DPV 4007 DPV 4012 DPV 4040 DPV 4024 DPV 4009 DPV 4019 DPV 4021 DPV 4022 DPV 4025 DPV 4020 DPV 4030 DPV 4026 DPV 4027 DPV 4029 DPV 4028 DPV 4018 DPV 4016 DPV 4013 DPV 4015 DPV 4035 DPV 4014 DPV 4017 Body Cover gasket Heavy Hex. nut C-Plate stud 3/4" Cover Air seat Water seat Latch Clapper arm assem. Clapper assem. Arm hinge pin plug Asbestos gasket Arm pin bushing Arm hinge pin Cotter pin brass Clapper pin bushing Latch pin bushing Latch pin Clapper hinge pin Machine screw Hex. cap screw Water seat disc Water seat gasket Air seat retainer Air seat gasket Lock washer D-34 D-29 D-2274 D-33 D-30 OPC-3-10A D-31 D-32 OMS-16-10A D-2272 D-2273 D-38 D-40 4" (DN100) Dry Valve Model "E" (GROOVE/GROOVE) Approvals : UL, cul, FM, LPCB Face to face : 15-1/4" Weight : 112 lbs Working Pressure : 175 PSI Bolt Circle : PN-16 / ANSI-125 2/4

3" - 4" - 6" ASTRA DRY VALVE TRIM "UL/cUL/FM" 11/16 3/4

4" & 6" ASTRA DRY VALVE TRIM "LPCB" UL, ULc, FM, LPCB and CE marked 11/16 4/4