ITS 300 & 500 SERIES POSITION MONITORING INSTALLATION AND OPERATION MANUAL

Similar documents
Electro-Pneumatic Converter YT-940 SERIES

VOLUME BOOSTER RELAYS YT-300 / 305 SERIES

Lock Up Valves YT-400, YT-405 USER'S MANUAL

LOCK UP VALVES YT-400/405/430/435 SERIES

SANP ACTING RELAYS YT-520/525/530 SERIES

Electro-Pneumatic Positioner YT-1000L (Linear Type)

GAS FUEL VALVE FORM AGV5 OM 8-03

MODEL NUMBER: AS18-2 USER GUIDE

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E

Part I - Installation

Part I -Installation Tools Needed Screwdriver/Adjustable Wrench to 1-1/2 MOUNTING

120 Series Explosion-Proof Pressure and Differential Pressure Switches

Magnetic level switch type MR783 Instruction Manual

Part I -Installation Tools Needed Screwdriver/Adjustable Wrench to 1-1/2 MOUNTING

Part I - Installation

RADROVER REAR RACK INSTALLATION MANUAL

453 Series Steam Heated Vaporizing Regulator

D10S/D20S Wall/Post Mount Inflator Quick Start Manual

Installation and Operation Manual

FLANGED MULTI-PORT BALL VALVES

G92 Series BASOTROL Automatic Pilot Gas Valve

Certification of EXPLOSION PROTECTED ELECTRICAL EQUIPMENT

2000 lb manual winch

FLANGED TWO-PIECE BALL VALVES

COMPACT METAL bender 99826

Model DPC3500 Continuous Low Range Dew Point Analyzer. Operations Manual

USER MANUAL FLOW SELECTOR PM1000 SAVE THESE INSTRUCTIONS. Federal (USA) law restricts this device to sale by or on the order of a physician.

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

FLANGED TWO-PIECE BALL VALVES

MODELS (2 foot Version) (4 foot Version)

USER MANUAL. MACMAG magnetic separator MHK MHF

SDX Submersible Depth Transmitter User Manual

Operating Instructions

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

Operating Instructions

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

ACCURA D80 User Manual

Operating Instructions of BROSA tension load cells, types 0111, 0113

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

PRAHER PLC-MP AQUASTAR MANAUL 2009

Transmitter CS 21 Operation Manual

SDX Submersible Depth Transmitter User Manual

Model No.: SFC-ED Torque Tool Serial No.: SFC Ref No.:

Oxygen Concentrator. Installation and Operation Manual. ClearWater Tech, LLC. Integrated Ozone Systems

Inspection Recommendations

ULTRA HIGH PRESSURE PAINT GRATE CLEANER FCT-JS OPERATION AND MAINTENANCE MANUAL

L230 LED 40 Watt Searchlight

Installation and Maintenance Instruction Manual

DK48 - DK800. Quick Start. Variable area flowmeter

HYDROVEX TTT Membrane Flow Regulator

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Transmitter CS 21 Operation Manual

MODEL 154XST INSTALLATION AND SERVICE INSTRUCTIONS FOR MODEL 154XST STROBE LIGHT FOR USE IN HARSH ENVIRONMENTS/ HAZARDOUS LOCATIONS

Instruction Manual Differential Pressure Transmitter

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

ROPV R40 E Series User Manual

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

TL-12 FLUSH TANK. Manual Ref. # MN-??? Polyurethane Machinery Corp. REVISION 1.0

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

PLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions

Installation, operating and maintenance Instructions for Seemag bypass level indicator

GEMS SENSORS & CONTROLS

BGA244 Binary Gas Analyzer

PRESSURE REDUCING STATION INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Operating Instructions

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

OEM Manual. MODEL ½ Digit DRUM SCALE

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

SMART POSITIONER YT-3300/3301 SERIES

INSTRUCTION MANUAL. FLOAT TYPE LEVEL TRANSMITTER HT-100R Series HITROL CO., LTD.

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

Further technical information is available on

OFFICINE OROBICHE S.p.A. 1/9

Budget Range Operators Handbook

Technical Data. Dimensions

SOTR Special Operations Tactical Respirator

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

G96 Series BASOTROL Dual Operator Valve

BGA158 Series CE Approved Class A Shutoff Gas Valve

INSTALLATION & MAINTENANCE INSTRUCTIONS

Technical Data. Dimensions

CS150 CAP STAPLER OWNER S MANUAL

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

GALISO SOAP OPTION FOR PCT-ADW-D

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

FLOWMETER MODELS: 1MFA, 4MFA, 6MFA and 8MFA Series SAVE THESE INSTRUCTIONS

100C Air Compressor Kit

CPX EMERGENCY STANDBY MANIFOLD INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

VOLLEYBALL SPIKE TRAINER. Assembly Instructions. Owner s Manual. Model # VST-400. Club Volleyball Gear

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

Sunset Swings By Health in Motion, LLC

BGA158 Series CE Approved Class B Shutoff Gas Valve

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Model ASSEMBLY and OPERATING INSTRUCTIONS

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

Transcription:

ITS 300 & 500 SERIES POSITION MONITORING ITS 300 & 500 SERIES POSITION MONITORING INSTALLATION AND OPERATION MANUAL (Explosion proof Ex d II T6) (Doc no: ITS00312-M) 74-6, hun Ui-Dong, Won Mi-Gu, Bucheon ity, Kyoung Ki-do, Korea Tel : 82-2-855-1365, 66 Fax : 82-2-855-1367 E-mail : roy75@i-tork.com Website: www.i-tork.com 1

ITS 300 & 500 SERIES POSITION MONITORING TABLE OF ONTENTS 1. INTRODUTION 2. MANUFATURER WARRANTY 3. PRODUTION DESRIPTION 4. LABEL DESRIPTION 5. SUFFIX SYMBOLS 6. SPEIFIATION 7. PARTS AND ASSEMBLY 8. DIMENSION 9. INSTALLATION 10. ONNETION POWER 2

ITS 300 & 500 SERIES POSITION MONITORING 1. Introduction Many thanks for purchasing our ITS300 or ITS500 series Limit Switch Box! For safe and proper operation, please read this manual carefully before using it and save it for reference. The Installation & Operation Manual should be provided to the end-user. The Installation & Operation Manual is subject to change due to quality improvements, without notice. The Installation & Operation Manual should not be duplicated or reproduced for any purpose without written approval from I-Tork ontrols Ltd. 2. Manufacturer Warranty For safety, it is imperative to follow instructions in the manual. It is not the manufacturer s liability for any damages which are caused by the users negligence. It is not the manufacturer s liability for any damages for accidents which are caused by any alteration or modification of the product and parts. If alteration or modification is necessary, please contact the manufacturer in advance. Manufacturer warrants the product from the date of original retail purchase of the product for One year, except as otherwise stated. Manufacturer warranty will not cover the products if the products have been subjected to abuse, accident, alteration, modification, tampering, negligence, misuse, faulty installation, lack of reasonable care, repair or service in any way that is not contemplated in the documentation for the product, or if the model or serial number has been altered, tampered with, defaced or removed; damages that occurs in shipment, due to act of God, failure due to power surge, and cosmetic damage. Improper or incorrectly performed maintenance or report voids this Limited Warranty. For detailed warranty information, please contact the corresponding local I-Tork distributors or main office in Korea. Safety Precautions ITS300/500 is designed for use in explosive gas atmosphere. The user must follow explosion proof procedures and safety precautions. For unused power connectors, please make sure to use blind plugs which are explosion proof certified. (Ex d II ) If cover must be opened for any reason, the power must be turned off and wait for at least 30 seconds. When applying power, please make sure to use flame proof proven sealing fitting and/or cable glands. (Ex d II ) (It is the user s responsibility to ensure appropriate Explosion proof fittings/cable glands are used) 3

ITS 300 & 500 SERIES POSITION MONITORING 3. PRODUTION DESRIPTION ITS300/500 position monitoring switch is used for the valve and actuators which rotate 90 degree s quarter turn. The first function of ITS300/500 is to provide visual indication of current position of valve and actuator. Dome indicator unit shows current position by color indication. If there is full red color indication, current position of valve or actuator is fully closed position, and yellow is on fully open position. Different olor indication combination can be provided to suit customer s specific requirement Secondly, ITS300/500 provides electrical signal at the fully open or closed position by activating mechanical switches (SPDT and DPDT), or Proximity sensors and other magnetic sensors which independently makes function. Switches vary in a wide range and construction to meet customer s requirement. ITS300/500 has the function of a direction free installation on different valves, and generally no need to adjust position of the internal cams to activate the switches as long as 0 at close and 90 at open because of adjustable cam. If it is required, customer can adjust it easily with finger or hand watching its movement. Red is for close position and Yellow is for open position. Enclosure is ertified to IE 60079-0 and IE 60079-1 and so can be used in Zone 1, 2, gas group IIA, IIB and II without any problem. 4. Label Description ONTROLS Warning Model: Enclosure: Switch: Rating: Lot no.: onnection: Indicates model number Indicates explosion proof grade Indicates switch or sensor type Indicates allowable input rating According to purchase order Indicates entry size 4

ITS 300 & 500 SERIES POSITION MONITORING 5. Suffix Symbols 6. Specification 5

ITS 300 & 500 SERIES POSITION MONITORING 7. Parts and Assembly OVER INDIATOR INDIATOR O-ring OVER BOLT OVER AM SHAFT O-ring BODY MIRO E-ring TERMINAL BLOK 8. Dimensions ONTROLS Warning 6 9. INSTALLATION Saftey Warning All input and supply pressure to valve, actuator, and other related devices must be turned off when installing. Please check the switch type and rating on the label on ITS300/500 enclosure, and be careful not to electrically exceed the switch rating. All installation and maintenance should be done by authorized personnel only.

ITS 300 & 500 SERIES POSITION MONITORING ITS300/500 is designed for use in explosive gas atmosphere. The end-user must follow the explosion proof procedures and safety precautions. Please make sure there is no explosive gas or material present before the installation. aution : In order to avoid unexpected accident, serious injury and property damage, make sure to cut all power supply to the actuator and valve before inspection, maintenance and repair, Ambient temperature : -20 o ~+60 o Direction and positioning of installation: No limitation excluding hazardous area. ITS300/500 Installation Proper size of Mounting bracket is required for mounting ITS300/500 on valve or actuator. Standard Mounting bracket is supplied together with ITS, but in case of requirement by customer for special application, please refer to the drawing inside of the body. The most important thing in mounting is to align the shaft of valve (or actuator) with ITS shaft. ITS s shaft is done according to NAMUR standard, so that it may suitable for various applications without further modification. 10. onnection Power Safety Warning Please make sure there is no explosive gas or material present before the installation. While the cover is open, the power should be turned off and wait for at least 30 seconds. For unused power connectors, please make sure to use the blind plugs which are explosion proof certified. When connecting power, please ensure the use of flameproof proven sealing fitting and/or cable glands. Please make sure the polarities are correct. Don t use too much force when pulling the cable, and make sure the cable doesn t peel off. Electrostatic Hazard : lean over indicator only with a damp cloth. Do not clean with solvents. 7

ITS 300 & 500 SERIES POSITION MONITORING Ground onnection : Ground onnection is provided on the external surface. This onnection should be used to connect the enclosure metal work to the Equi-potential Bonding System/Earth. This is in addition to any Protective Earth Terminals provided inside the enclosure. It must be sized in accordance with local rules for electrical installations and not be smaller than 4mm2. Electrical wiring must be done according to the specification of international standard or local specific regulation. ITS300/500 provides two PF3/4 (Other thread sizes are optional) conduits for the wiring and by using approved explosion proof couplings, ensures tight sealing and explosion proof function. Mechanical Type(2 SPDT ) MEHANIAL S LOSE N N SOLEID VALVE LOSE EXT 1 3 4 5 6 7 8 2 GROUND Proximity Type(NPN Sensor ) PROXIMITY S LOSE SOLEID VALVE GROUND (PSN17-5DNU) (NPN) 8 EXT 6 7 5 4 LOSE 1 2 3 LOAD LOAD + - + - Proximity Type(P&F NJ2-V3-N ) PROXIMITY S LOSE SOLEID VALVE EXT 8 7 6 5 LOSE 1 2 3 4 (NJ2-V3-N) LOAD + LOAD - + - GROUND Mechanical Type(2 DPDT ) GROUND MEHANIAL 2-DPDT LOSE N N N N BRN BLK BRN BLK BRN BLK BRN BLK 12 11 7 9 10 8 6 5 LOSE 1 2 3 4 8

ITS 300 & 500 SERIES POSITION MONITORING Posotion Transmitter Type MEHANIAL ES LOSE N T N 5 6 7 8 4 1 2 3 15~28VD LOAD Output 4~20mA GROUND Adjustment Uper Switch Push up the Upper Switch and turn right or left to the preferred position. Adjustment Lower Switch Pull down the Lower Switch and turn right or left to the preferred position Bracket 9

ITS 300 & 500 SERIES POSITION MONITORING Rating Table for ITS300 & ITS500 Wire Standard 10