Air Preparation Catalogue

Similar documents
Air Preparation. Regulators, Pressure Regulators, Lubricators and Accessories. Keeping the World Flowing

1200 Series Pressure Regulators

FILTER, REGULATOR AND FILTER/REGULATOR Stainless Steel 316L Compact 1/4, High Flow 1/4-1/2

NEWS 66. VALVES & AIR SERVICE UNITS STEEL LINE Series

Avenger Model 33M Installation & Operation Instructions

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

ACTUATORS AND INSTRUMENTS

64 Series Pressure Reducing Regulators

Precision and Instrument Regulators 1/4" port size

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

Direct Operated Precision Regulator Modular Style. Standard Specifications

PRO-50 Instrument Supply Regulator

BL68 - Olympian Plus, plug-in system Filter/regulators and lubricators

Related Products: Auto Drain Valve. Model/Specifications. Model

Precision matters. HiQ equipment for specialty gases.

lternative odels 3.87 (98) anual Drain 2.67 (68) 3.72 (94) utomatic Drain 2.13 (54) 1.12 (28) P1H, PTH Filter/Regulator-Lubricator Combination Units 0

Air preparation units

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Air-service devices, Series MU1

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

IP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

B74G - EXCELON Modular System General purpose filter/regulator

Locator Locator-D-Lux Air-Saver G1 Air-Saver G2

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

Pressure Dump Valve Service Kit for Series 2300 Units

System Pressure Manager Standard & System Pressure Manager Plus

IP2, IP2A and IP2D. Spirax-Monnier International Compressed Air Filter/ Regulators

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

INDUSTRIAL EXCESS ESS FLOW VALVES

BACK PRESSURE / SUSTAINING

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

B84G - Excelon Plus Modular System General purpose filter/regulator

BACK PRESSURE / SUSTAINING

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

Type 4708 Supply Pressure Regulator

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

Booster Regulator/Air Tank

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

CATALOGUE // The Fort Vale Range of Equipment to suit Hydrogen Peroxide Tank Specification. Fort Vale Engineering Ltd. 2009

MPC1M, MPC2M and MPC2AM Monnier High Efficiency Compressed Air Filter / Regulators

PILOT OPERATED RELIEF VALVE SAFETY PRODUCTS THAT PROTECT EQUIPMENT, LIVES & THE ENVIRONMENT

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

FILTER TYPE PRESSURE SNUBBER

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type

F68G - Olympian Plus plug-in system General purpose filter

RMG 5020 Gas Pressure Regulator Enabling Dependable Gas Operations

GP1 & GP2. Electropneumatic Regulators FOR PRESSURE CONTROL TO 1,000 PSI

Valve actuation at the world s largest flow metering calibration facility

Rate of Flow Valve Series 120

Fisher 2625 and 2625NS Volume Boosters

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Air service units series K G1/8, G1/4

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

Lock Up Valves YT-400, YT-405 USER'S MANUAL

CASH VALVE TYPE KP BACK PRESSURE VALVES

B84G - Excelon Plus Modular System General purpose filter/regulator

Pressure Independent Control Series

TECHNICAL DATA CAUTION

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

Thrust Compensator. Redefining Flow Control. Actuation Solutions for Nuclear Powerplants

Model 10. Low-Medium Pressure Reducing Regulator

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

Type 4708 Supply Pressure Regulator

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

TECHNICAL DATA. Page 1 of 12

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

THE HF-210 SERIES. Operating and Service Manual. Series includes all variants of HF-210/211. Issue A October 2014 *Section 6.

safety Shut-Off Valve HON 721

VOLUME BOOSTER RELAYS YT-300 / 305 SERIES

Pressure Dump Valve Service Kit for Series 3000 Units

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

LOCK UP VALVES YT-400/405/430/435 SERIES

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New

Gas Hydraulic Valve Operator

Liquid Level Controllers

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

Series K Air service units G 1/8, G 1/4

Budget Range Operators Handbook

MF2M Monnier Miniature Compressed Air Filter

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

NGP-250/500 Nitrogen Generator Quick Start Guide

Model 4000 Pressure Controller

Precision pressure regulators LRP/LRPS

SPCH/ Blowing block

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Power Valve: Precision Regulator. High precision, large capacity relief regulator

Masoneilan* 78 Model Air Filter Regulator

Water Solenoids Safety Valves Air. Meters. Butterfly Ball Gate Globe Strainers Pressure Gauges Thermometers

REFRIGERATION SYSTEM COMPONENTS

Cover headline. Cover subheadline. Check Valves

The Ins and Outs of I/P Transducers

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

Transcription:

Air Preparation Catalogue Redefining Flow Control Regulators, Pressure Regulators, Lubricators and Accessories 3525 series, 3550 series 3500 series, 3575 series OPD

Contents Section Page Section Page Introduction 3 3525 Series air service units Compact Filter Regulator 4 3550 Series air service units Filter Regulators 6 Filters 0 Pressure Regulators 3 Accessories 5 3500 Series air service units Filter Regulators 7 Filters 20 Pressure Regulators 24 Lubricator 26 Accessories 28 3575 Series air service units Filter Regulators 3 Filters 33 Pressure Regulators 35 Over Pressure Device Features and Benefits 37 General Description 38 Development 38 Performance Characteristics 39 Rotork Midland in the Oil and Gas Industries 4 Rotork Instruments 4 Rotork Site Services Service and Support 42 Rotork is the global market leader in valve automation and flow control. Our products and services are helping organisations around the world to improve efficiency, assure safety and protect the environment. We strive always for technical excellence, innovation and the highest quality standards in everything we do. As a result, our people and products remain at the forefront of flow control technology. Uncompromising reliability is a feature of our entire product range, from our flagship electric actuator range through to our pneumatic, hydraulic and electro-hydraulic actuators, as well as instruments, gearboxes and valve accessories. Rotork is committed to providing first class support to each client throughout the whole life of their plant, from initial site surveys to installation, maintenance, audits and repair. From our network of national and international offices, our engineers work around the clock to maintain our position of trust. Rotork. Redefining flow control. 2

Introduction As a specialist manufacturer of stainless steel large flow air service equipment we offer comprehensive, purpose designed, engineered and manufactured solutions for filtration and regulation of compressed air and gases for the actuation industries. Certification Options Available ATEX (GOST R) Redefining Flow Control 3

3525 Series air service units /4 Compact Filter Regulator A 36L stainless steel combined unit for filtration and regulation of compressed air and gases. Features and Benefits Designed for severe environments Self relieving /4 NPT ported filter regulator 550 l/min (9.7 dm 3 /s) flow capacity at bar differential 0.5-8 bar outlet pressure range 20 bar maximum inlet pressure Full 36L stainless steel construction FKM Seals Manual drain 25 µm filter Mounting bracket included as standard Ambient Temperature Range -20 to +80 C (-4 to +76 F) Port & Connections Port: /4 NPT Gauge/breather: /8 NPT /4 NPT optional, add suffix 'X' (refer to table) Filter 25 µm nominal Condensate bowl capacity: 5 cc Flow At 0 bar (45 psi) supply pressure, 6.3 bar (9.35 psi) secondary pressure, bar (4.5 psi) pressure drop 550 l/min (9.42 SCFM) Operating Media Instrument air, sweet natural gas, inert gases Accessories Available Stud mounting kit 0- bar pressure gauge See page 5 for ordering details. Flow Characteristics (in accordance with BS6953 parts & 2) 4.5 4 3.5 Forward Flow Port Size: ¼ Model Number: 2FRMSV082D Outlet Pressure (bar) 3 2.5 2.5 0.5 0 0 2 4 6 8 0 2 4 6 Air Flow Rate dm³/s, ANR 2.5 Bar Set Pressure, Increasing Flow 4.0 Bar Set Pressure, Increasing Flow 2.5 Bar Set Pressure, Decreasing Flow 4.0 Bar Set Pressure, Decreasing Flow 4

3525 Series air service units /4 Compact Filter Regulator - Engineering Drawings View with standard mounting bracket fitted View with optional mounting stud kit SSBF238-2 (screwed into un-used gauge port) Ordering Information Product Code Size Gauge Port Size Regulated Pressure bar (psi) Max Inlet Pressure bar Weight kg CV 2FRMSV082D /4 NPT /8 NPT 0.5 to 8.0 (7.2 to 6) 20 0.675 0.48 2FRMSV082DX /4 NPT /4 NPT (Gauge Port Option) 0.5 to 8.0 (7.2 to 6) 20 0.675 0.48 Note: Where /4 NPT gauge ports are required a /8 NPT to /4 NPT fitting will be provided. Price on application. Accessories Ordering Information Product Code SSBF238/2 SSF53N/ GLY Item Stud Mounting Kit 0- bar pressure gauge Note: Specification and engineering drawings for accessories available on request. Redefining Flow Control 5

3550 Series air service units /4 to 3 /4 Filter Regulator A 36L stainless steel combined unit for filtration and regulation of compressed air and gases for the actuation industries. Features and Benefits Specifically designed for severe environments Non or self-relieving 40 micron element stainless steel 36 as standard, 5 micron option available Ambient temperature range -20 to +80 ºC (-4 to +76 ºF) Low temperature option available 36L stainless steel construction Regulated pressure range from 0.50 to 2.0 bar depending on model selection Large flow characteristics NACE capability option available Ambient Temperature Range Standard: -20 to +80 ºC (-4 to +76 ºF) Low temp: -50 to +90 ºC (-58 to +94 ºF) optional Maximum Relief Flow At 2 bar (29 psi) secondary pressure 0.5 cc/sec (0.03 cu in/sec) Flow At 0 bar (45 psi) supply pressure, 6 bar (87 psi) secondary pressure, bar (4.5 psi) pressure drop. /4-3,720 l/min (30 SCFM) /2 and 3 /4-6,000 l/min (22 SCFM) Maximum Inlet Pressure Manual drain - 20 bar (290 psi) Automatic drain - 7 bar (247 psi) Ports NPT (BSP option available - consult factory for part codes) /4, /2, 3 /4 Gauge Ports /8 NPT /4 NPT (option available - suffix product code with 'X') Relief Vent Port /8 NPT (fitted with breather) Note: Not fitted on low temperature option Bowl Capacity 2 cc (.28 cu ins) Accessories Available Mounting brackets Stainless steel pressure gauge Hand wheel See page 5-6 for ordering details Operating Media Gases - air, inert gas, sweet (natural) and sour gases - NACE Construction Materials Body/bonnet/bowl and internals: 36L stainless steel Element: 40 micron 36 stainless steel (5 micron option available - suffix product code with '05') Seals: Standard option - Fluoroelastomer Low temperature option - EPDM Certification Options Available ATEX (GOST R) 6

3550 Series air service units /4 to 3 /4 Filter Regulator - Flow Characteristics Flow - SCFM 0 50 00 50 200 250 6 Primary pressure 0 barg (45 psi) with 8 barg (6) spring 90 5 /4 /2 3 /4 75 Secondary Pressure (bar) 4 3 2 /4 /4 /2 3 /4 /2 3 /4 60 45 30 Secondary Pressure (psi) /4 /2 3 /4 5 0 0 0 20 40 60 80 00 20 Flow - l/sec Redefining Flow Control 7

3550 Series air service units /4 to 3 /4 Filter Regulators - Engineering drawings (manual drain) Relief Port Gauge Port (Front & Rear) A 23.5 Inlet Outlet A 4 - B x 8 deep (both ends) Available only on ¼" and ½" 2 line ports 04.5 67 (¼ to ½ versions) Manual Drain 7 (¾ Version) Self-Relieving with manual drain Rear gauge port plugged 57 2.25 Standard Product Code Low Temperature Version Size Filter Regulated Pressure bar (psi) Max Inlet Pressure bar A B Weight kg 2FRMSV022A 2FRMSF022A ¼ 24 M4.75 2.4 4FRMSV022A 4FRMSF022A ½ Manual 0.50 to 2.0 Drain (7.2 to 29) 20 28 M5.75 4.4 6FRMSV022A 6FRMSF022A ¾ - -.95 5.0 2FRMSV042A 2FRMSF042A ¼ 24 M4.75 2.4 4FRMSV042A 4FRMSF042A ½ Manual 0.50 to 4.0 Drain (7.2 to 58) 20 28 M5.75 4.4 6FRMSV042A 6FRMSF042A ¾ - -.95 5.0 2FRMSV082A 2FRMSF082A ¼ 24 M4.75 2.4 4FRMSV082A 4FRMSF082A ½ Manual 0.50 to 8.0 Drain (7.2 to 6) 20 28 M5.75 4.4 6FRMSV082A 6FRMSF082A ¾ - -.95 5.0 2FRMSV22A 2FRMSF22A ¼ 24 M4.75 2.4 4FRMSV22A 4FRMSF22A ½ Manual 0.50 to 2.0 Drain (7.2 to 74) 20 28 M5.75 4.4 6FRMSV22A 6FRMSF22A ¾ - -.95 5.0 5 micron option available - suffix product code with '05'. ¼" NPT gauge port option available - suffix product code with 'X' Cv 8

3550 Series air service units /4 to 3 /4 Filter Regulators - Engineering Drawings (auto drain) Relief Port Gauge Port (Front & Rear) A 23.5 64.5 Rear gauge port plugged 57 A 4 - B x 8 deep (both ends) Available only on ¼" and ½" 2 line ports 67 (¼ to ½ versions) 7 (¾ Version) Self-Relieving with automatic drain ¹/8 NPT autodrain port 2.25 Product Code Size Filter Regulated Pressure bar (psi) Max Inlet Pressure bar A B Weight kg 2FRASV022A ¼ 24 M4 2.05 2.4 4FRASV022A ½ Auto 0.50 to 2.0 Drain (7.2 to 29) 7 28 M5 2.05 4.4 6FRASV022A ¾ - - 2.25 5.0 2FRASV042A ¼ 24 M4 2.05 2.4 4FRASV042A ½ Auto 0.50 to 4.0 Drain (7.2 to 58) 7 28 M5 2.05 4.4 6FRASV042A ¾ - - 2.25 5.0 2FRASV082A ¼ 24 M4 2.05 2.4 4FRASV082A ½ Auto 0.50 to 8.0 Drain (7.2 to 6) 7 28 M5 2.05 4.4 6FRASV082A ¾ - - 2.25 5.0 2FRASV22A ¼ 24 M4 2.05 2.4 4FRASV22A ½ Auto 0.50 to 2.0 Drain (7.2 to 74) 7 28 M5 2.05 4.4 6FRASV22A ¾ - - 2.25 5.0 Low temperature version not available in auto drain. 5 micron option available - suffix product code with '05'. ¼" NPT gauge port option available - suffix product code with 'X' Cv Redefining Flow Control 9

3550 Series air service units /4 to 3 /4 Filters A 36L stainless steel unit for filtration of compressed air and gases for the actuation industries. Features and Benefits Specifically designed for severe environments 40 micron element stainless steel 36 as standard, 5 micron option available Ambient temperature range -20 to +80 ºC (-4 to +76 ºF) Low temperature version available 36L stainless steel construction Large flow characteristics NACE capability option available Ambient Temperature Range Standard: -20 to +80 ºC (-4 to +76 ºF) Low temp: -50 to +90 ºC (-58 to +94 ºF) optional Maximum Inlet Pressure Manual drain - 20 bar (290 psi) Automatic drain - 7 bar (247 psi) Flow At 7 bar (02 psi) supply pressure, 0.35 bar (5 psi) pressure drop. /4 -,380 l/min (49 SCFM) /2 and 3 /4-2,940 l/min (04 SCFM) Ports NPT (BSP option available - consult factory for part codes) /4, /2, 3 /4 Automatic Drain Port /8 NPT Bowl Capacity 2 cc (.28 cu ins) Operating Media Gases - air, inert gas, sweet (natural) and sour gases - NACE Construction Materials Body/bonnet/bowl and internals: 36L stainless steel Element: 40 micron 36 stainless steel (5 micron option available - suffix product code with '05') Seals: Standard option - Fluoroelastomer Low temperature option - EPDM Air Flow for ¼ and ½ Filter Accessories Available Mounting brackets See page 5 for ordering details Pressure Drop - kpa Certification Options Available ATEX (GOST R) Flow - l/sec 0

3550 Series air service units /4 to 3 /4 Filters - Engineering Drawings (manual drain) A 3 4 - B x 8 deep (both ends) 2 line ports 04.5 Manual Drain 67 (¼ to ½ versions) 2.3 7 (¾ Version) Filter with manual drain 2.3 57 Product Code Low Temperature Version Size Filter Max Inlet Pressure bar A B Weight kg 2FLMSV202A 2FLMSF202A ¼ 24 M4.3 2.4 4FLMSV202A 4FLMSF202A ½ Manual Drain 20 28 M5.3 4.4 6FLMSV202A 6FLMSF202A ¾ - -.5 5.0 5 micron option available - suffix product code with '05'. Cv Redefining Flow Control

3550 Series air service units /4 to 3 /4 Filters - Engineering Drawings (auto drain) A 4 - B x 8 deep (both ends) 2 line ports A 64.5 3 67 (¼ to ½ versions) ¹/8 NPT Auto-Drain Port 2.3 7 (¾ version) Filter with automatic drain 2.3 57 Product Code Size Filter Max Inlet Pressure bar A B Weight kg 2FLASV72A ¼ 24 M4.6 2.4 4FLASV72A ½ Auto Drain 7 28 M5.6 4.4 6FLASV72A ¾ - -.8 5.0 Low temperature version not available in auto drain. 5 micron option available - suffix product code with '05'. Cv 2

3550 Series air service units /4 to 3 /4 Pressure Regulators A 36L stainless steel unit for the pressure regulation of compressed air and gases for the actuation industries. Features and Benefits Specifically designed for severe environments Non or self-relieving Ambient temperature range -20 to +80 ºC (-4 to +76 ºF) Low temperature version available 36L stainless steel construction Large flow charateristics NACE capability option available Ambient Temperature Range Standard: -20 to +80 ºC (-4 to +76 ºF) Low temp: -50 to +90 ºC (-58 to +94 ºF) optional Maximum Relief Flow At 2 bar (29 psi) secondary pressure 0.5 cc/sec (0.03 cu in/sec) Flow At 0 bar (45 psi) inlet pressure, 6 bar (87 psi) secondary pressure with bar (4.5 psi) pressure drop. /4-6,80 l/min (28 SCFM) /2 and 3 /4-2,780 l/min (33 SCFM) Ports NPT (BSP option available - consult factory for part codes) /4, /2, 3 /4 Gauge Ports /8 NPT /4 NPT (option available - suffix product code with 'X') Operating Media Gases - air, inert gas, sweet (natural) and sour gases - NACE Construction Materials Body/bonnet/bowl and internals: 36L stainless steel Seals: Standard option - Fluoroelastomer Low temperature option - EPDM 6 5 Flow - SCFM 0 50 00 50 200 250 Primary pressure 0 barg (45psi) with 8 barg (6) spring /4 /2 3 /4 90 75 Relief Vent Port /8 NPT (fitted with breather) Note: Not fitted on low temperature option Accessories Available Mounting brackets Stainless steel pressure gauge Hand wheel Secondary Pressure (bar) 4 3 2 /4 /4 /2 3 /4 /2 3 /4 60 45 30 Secondary Pressure (Psi) See page 5-6 for ordering details /4 /2 3 /4 5 Certification Options Available ATEX (GOST R) 0 0 20 40 60 80 00 20 Flow - L/Sec 0 Redefining Flow Control 3

3550 Series air service units /4 to 3 /4 Pressure Regulators - Engineering Drawings Relief Port Rear gauge port plugged 57 23.5 Gauge Port (Front & Rear) A A 4 - B x 8 deep (both ends) Available only on ¼" and ½" 64 2 line ports 67 (¼ to ½ versions) 7 (¾ version) Self-Relieving 2.3 Product Code Low Temperature Version Size Regulated Pressure bar (psi) Max Inlet Pressure bar A B Weight kg 2PRVSV022A 2PRVSF022A ¼ 24 M4.6 2.4 4PRVSV022A 4PRVSF022A ½ 0.50 to 2.0 (7.2 to 29) 20 28 M5.6 4.4 6PRVSV022A 6PRVSF022A ¾ --- ---.8 5.0 2PRVSV042A 2PRVSF042A ¼ 24 M4.6 2.4 4PRVSV042A 4PRVSF042A ½ 0.50 to 4.0 (7.2 to 58) 20 28 M5.6 4.4 6PRVSV042A 6PRVSF042A ¾ --- ---.8 5.0 2PRVSV082A 2PRVSF082A ¼ 24 M4.6 2.4 4PRVSV082A 4PRVSF082A ½ 0.50 to 8.0 (7.2 to 6) 20 28 M5.6 4.4 6PRVSV082A 6PRVSF082A ¾ --- ---.8 5.0 2PRVSV22A 2PRVSF22A ¼ 24 M4.6 2.4 4PRVSV22A 4PRVSF22A ½ 0.50 to 2.0 (7.2 to 74) 20 28 M5.6 4.4 6PRVSV22A 6PRVSF22A ¾ --- ---.8 5.0 ¼" NPT gauge port option available - suffix product code with 'X' Cv 4

3550 Series air service units Accessories for ¼" to ¾" units - supplied separately Plastic handwheel kit Stud mounting kit Ø44 M8 8 30 6 A/F Socket /8" NPT 4 M8 3 A/F Hex Product Code Description Product Code Description SSAF238/23 Kit comprises of plastic handwheel, pressure adjusting screw (36 stainless steel) and handwheel retaining screw (36 stainless steel) SSBF238/2 Kit comprises of stud complete with 2 locknuts and is designed to screw into un-used gauge port. All components 36 stainless steel. Mounting bracket A C D ØH N E B K E 4 Holes ØF 2 Mounting Slots L wide x M long J Product Code Suitable for A B C D E F H J K L M N SSF20-7S ¼" units (Short) 79 00 25 60 24 4.5 26 4 80 5.5 8.5 2 SSF20-7 ¼" units (Long) 95 00 25 76 24 4.5 26 4 80 5.5 8.5 2 SSF40-7 ½",¾"units 95 00 25 76 28 4.5 26 4 80 5.5 8.5 2 Component material 36 stainless steel. Brackets are supplied complete with fasteners. Note: Part numbers above are for single items Redefining Flow Control 5

3550 Series air service units Accessories for ¼" to ¾" units - supplied separately Pressure gauge SS-36L - Glycerine filled Ø 57.5 23 28 0 /8"NPT 4 A/F HEX Product Code Size mm Regulated Pressure bar SSF53N/2GLY 50 0 to 2 SSF53N/4GLY 50 0 to 4 SSF53N/GLY 50 0 to Please consult factory for low temperature version if required. Tamperproof cap kit 47 36 5 4 A/F SQ 3 A/F HEX M8 Wire Lock Hole Product Code SSAF238/22 Description Kit comprises of pressure adjusting screw and tamperproof cap. All material 36 stainless steel 6

3500 Series air service units 3 /4 to Filter Regulators A 36L stainless steel combined unit for filtration and regulation of compressed air and gases for the actuation industries. Features and Benefits Specifically designed for severe environments 40 micron element as standard, 5 micron option available Ambient temperature range -20 to +80 ºC (-4 to +76 ºF) Low temperature option available Non or self-relieving 36L stainless steel construction Large flow characteristics Bowl capacity window Ambient Temperature Range Standard: -20 to +80 ºC (-4 to +76 ºF) Low temp: -50 to +90 ºC (-58 to +94 ºF) optional Maximum Relief Flow At 2 bar (29 psi) secondary pressure 0.5 cc/sec (0.03 cu in/sec) Flow At 7 bar (02 psi) supply pressure, 6 bar (87 psi) secondary pressure, bar (4.5 psi) pressure drop. 7,800 l/min (274 SCFM) Maximum Inlet Pressure Manual drain - 20 bar (290 psi) Automatic drain - 7 bar (247 psi) Ports NPT (BSP option available - consult factory for part codes) 3 /4, Gauge Ports /8 NPT Relief Vent Port /8 NPT (fitted with breather) Note: Not fitted on low temperature option Bowl Capacity 260 cc (5.87 cu ins) Accessories Available Mounting brackets Stainless steel pressure gauge See page 28-29 for ordering details Operating Media Gases - air, inert gas and sweet (natural) gases Construction Materials Body/bonnet/bowl and internals: 36L stainless steel Element: 40 micron sintered polypropylene (5 micron option available - suffix product code with '05') Seals: Standard option - Fluoroelastomer Low temperature option - EPDM Certification Options Available ATEX (GOST R) Redefining Flow Control 7

3500 Series air service units 3 /4 to Filter Regulators - Engineering Drawings (manual drain) Relief Port 29 Gauge Port (Front & Rear) 2 - M8 x 2 deep (Front & Rear) Optional Mounting Bracket 2 line ports 80.5 70 20 Manual Drain 45 20 2-Ø 8.5 Mounting Holes Self-Relieving with manual drain 82 6 Product Code Low Temperature Version Size Filter Regulated Pressure bar (psi) Max Inlet Pressure bar Weight kg 6FRMSV022 6FRMSL022 ¾ Manual 0.50 to 2.0 5.75 6.5 20 8FRMSV022 8FRMSL022 Drain (7.2 to 29) 5.75 8.8 6FRMSV042 6FRMSL042 ¾ Manual 0.50 to 4.0 5.75 6.5 20 8FRMSV042 8FRMSL042 Drain (7.2 to 58) 5.75 8.8 6FRMSV072 6FRMSL072 ¾ Manual 0.50 to 7.0 5.75 6.5 20 8FRMSV072 8FRMSL072 Drain (7.2 to 02) 5.75 8.8 6FRMSV02 6FRMSL02 ¾ Manual 0.50 to 0.0 5.75 6.5 20 8FRMSV02 8FRMSL02 Drain (7.2 to 45) 5.75 8.8 5 micron option available - suffix product code with '05'. Cv 8

3500 Series air service units 3 /4 to Filter Regulators - Engineering Drawings (auto drain) Relief Port 29 Gauge Port (Front & Rear) 2 - M8 x 2 deep (Front & Rear) Optional Mounting Bracket 2 line ports 99.5 70 20 ¹/8 NPT auto-drain port 45 20 2-Ø 8.5 Mounting Holes Self-Relieving with auto drain 82 6 Product Code Size Filter Regulated Pressure bar (psi) Max Inlet Pressure bar Weight kg 6FRASV022 ¾ Auto 0.50 to 2.0 5.75 6.5 7 8FRASV022 Drain (7.2 to 29) 5.75 8.8 6FRASV042 ¾ Auto 0.50 to 4.0 5.75 6.5 7 8FRASV042 Drain (7.2 to 58) 5.75 8.8 6FRASV072 ¾ Auto 0.50 to 7.0 5.75 6.5 7 8FRASV072 Drain (7.2 to 02) 5.75 8.8 6FRASV02 ¾ Auto 0.50 to 0.0 5.75 6.5 7 8FRASV02 Drain (7.2 to 45) 5.75 8.8 Low temperature version not available in auto drain. 5 micron option available - suffix product code with '05'. Cv Redefining Flow Control 9

3500 Series air service units 3 /4 to Filters A 36L stainless steel unit for filtration of compressed air and gases for the actuation industries. Features and Benefits Specifically designed for severe environments 40 micron element as standard, 5 micron option available Ambient temperature range -20 to +80 ºC (-4 to +76 ºF) Low temperature option available 36L stainless steel construction Large flow characteristics Bowl capacity window Ambient Temperature Range Standard: -20 to +80 ºC (-4 to +76 ºF) Low temp: -50 to +90 ºC (-58 to +94 ºF) optional Flow At 7 bar (02 psi) supply pressure, 0.35 bar (5 psi) pressure drop. 0,020 l/min (353 SCFM) Maximum Inlet Pressure Manual drain - 20 bar (290 psi) Automatic drain - 7 bar (247 psi) Ports NPT (BSP option available - consult factory for part codes) 3 /4, Bowl Capacity 260 cc (5.87 cu ins) Operating Media Gases - air, inert gas and sweet (natural) gas Construction Materials Body/bonnet/bowl and internals: 36L stainless steel Element: 40 micron sintered polypropylene (5 micron option available - suffix product code with '05') Seals: Standard option - Fluoroelastomer Low temperature option - EPDM Accessories Available Mounting brackets See page 29 for ordering details Certification Options Available ATEX (GOST R) 20

3500 Series air service units 3 /4 to Filters - Engineering Drawings (manual drain) 49.5 2 - M8 x 2 deep (Front & Rear) Optional Mounting Bracket 2 line ports 80.5 70 20 45 20 2-Ø 8.5 Mounting Holes Manual Drain Filter with manual drain 82 6 Product Code Low Temperature Version Size Filter Max Inlet Pressure bar Weight kg 6FLMSV202 6FLMSL202 ¾ Manual 3.75 6.5 20 8FLMSV202 8FLMSL202 Drain 3.75 8.8 5 micron option available - suffix product code with '05'. Cv Redefining Flow Control 2

3500 Series air service units 3 /4 to Filters - Engineering Drawings (auto drain) 70 20 45 20 6 82 49.5 2 - M8 x 2 deep (Front & Rear) Optional Mounting Bracket 2 line ports 99.5 2-Ø 8.5 Mounting Holes ¹/8 NPT auto-drain port Filter with automatic drain Product Code Size Filter Max Inlet Pressure bar Weight kg 6FLASV72 ¾ Auto 3.75 6.5 7 8FLASV72 Drain 3.75 8.8 Low temperature version not available in auto drain. 5 micron option available - suffix product code with '05'. Cv 22

3500 Series air service units 3 /4 to Filters - Flow Characteristics Flow Standard - Cubic feet/min 40 0 20 40 60 80 00 20 40.0 35 2 barg 0.0 Pressure Drop across filter - Barg 30 25 20 5 0 4 barg 6 barg 7 barg 0 barg 9.0 8.0 7.0 6.0 5.0 4.0 3.0 Pressure Drop across filter - psi 5 2.0.0 0 0 20 40 60 80 00 20 40 60 80 0 Flow Normal - I/sec Redefining Flow Control 23

3500 Series air service units 3 /4 to Pressure Regulators A 36L stainless steel unit for pressure regulation of compressed air and gases for the actuation industries. Features and Benefits Specifically designed for severe environments Non or self-relieving Ambient temperature range -20 to +80 ºC (-4 to +76 ºF) Low temperature option available 36L stainless steel construction Large flow characteristics Ambient Temperature Range Standard: -20 to +80 ºC (-4 to +76 ºF) Low temp: -50 to +90 ºC (-58 to +94 ºF) optional Maximum Relief Flow At 2 bar (29 psi) secondary pressure 0.5 cc/sec (0.03 cu in/sec) Flow At 7 bar (02 psi) supply pressure, 6 bar (87 psi) secondary pressure, bar (4.5 psi) pressure drop. 7,800 l/min (274 SCFM) Ports NPT (BSP option available - consult factory for part codes) 3 /4, Gauge Ports /8 NPT Relief Vent Port /8 NPT (fitted with breather) Note: Not fitted on low temperature option Operating Media Gases - air, inert gas, sweet (natural) gas Construction Materials Body/bonnet/bowl and internals: 36L stainless steel Seals: Standard option - Fluoroelastomer Low temperature option - EPDM Accessories Available Mounting brackets Stainless steel pressure gauge See page 28-29 for ordering details Product Code Low Temperature Version Size Regulated Pressure bar (psi) Max Inlet Pressure bar Weight kg 6PRVSV022 6PRVSL022 ¾ 0.50 to 2.0 5.0 6.5 20 8PRVSV022 8PRVSL022 (7.2 to 29) 5.0 8.8 6PRVSV042 6PRVSL042 ¾ 0.50 to 4.0 5.0 6.5 20 8PRVSV042 8PRVSL042 (7.2 to 58) 5.0 8.8 6PRVSV072 6PRVSL072 ¾ 0.50 to 7.0 5.0 6.5 20 8PRVSV072 8PRVSL072 (7.2 to 02) 5.0 8.8 6PRVSV02 6PRVSL02 ¾ 0.50 to 0.0 5.0 6.5 20 8PRVSV02 8PRVSL02 (7.2 to 45) 5.0 8.8 Cv Certification Options Available ATEX (GOST R) 24

3500 Series air service units 3 /4 to Pressure Regulators - Engineering Drawings & Flow Characteristics Relief Port 29 Gauge Port (Front & Rear) 70 2 - M8 x 2 deep (Front & Rear) Optional Mounting Bracket 49.5 2 Line Ports 20 45 20 2-Ø 8.5 Mounting Holes 6 Flow - SCFM 0 50 00 50 200 250 300 82 7 Primary pressure 7 barg (02 psi) with 0 barg (45 psi) spring 00 90 6 80 5 70 Self-Relieving pressure regulator Secondary Pressure (bar) 4 3 60 50 40 Secondary Pressure (psi) 2 30 20 0 0 0 0 20 40 60 80 00 20 40 Flow - L/Sec Redefining Flow Control 25

3500 Series air service units /2 Lubricator A 36L stainless steel unit providing lubrication of compressed air for the actuation industries. Features and Benefits Specifically designed for severe environments Accurate drip rate adjustment Can be filled under pressure Transparent sight feed dome Ambient temperature range -20 to +80 ºC (-4 to +76 ºF) 36L stainless steel construction Built in flow sensor to automatically adjust lubrication delivery to meet wide air flow demand Ambient Temperature Range Standard: -20 to +80 ºC (-4 to +76 ºF) Working Pressure 7 bar (247 psi) Ports NPT (BSP option available - consult factory for part codes) /2 NPT Bowl Capacity 380 cc (23.2 cu ins) Operating Media Gases - air, inert gas and sweet (natural) gases Construction Materials Body/bonnet/bowl and internals: stainless steel 36L Seals: Nitrile Bowl: 36 stainless steel Acrylic flow and sight glass Product Code 4LUBSN72 26

3500 Series air service units /2 Lubricator - Engineering Drawings 55 9 2-Ø 8.5 Mounting Holes 0 4 2-½ NPT Line Ports 52 40 56 20 45 Function Symbol 85 Redefining Flow Control 27

3500 Series air service units Accessories for ¾" to " units - supplied separately Pressure gauge SS-36L - Glycerine filled Ø 57.5 23 28 0 /8"NPT 4 A/F HEX Product Code Size mm Regulated Pressure bar SSF53N/2GLY 50 0 to 2 SSF53N/4GLY 50 0 to 4 SSF53N/GLY 50 0 to Please consult factory for low temperature version if required. Tamperproof cap kit 80 50 6 7 A/F SQ 9 A/F HEX M2 Wire Lock Hole Product Code SSAF638/22 Description Kit comprises of pressure adjusting screw and tamperproof cap. All material stainless steel 28

3500 Series air service units Accessories for ¾" to " units - supplied separately Mounting bracket 08 25 76 Ø40 2 35 00 80 35 Slots to suit M5 screws 2 mounting slots 5.5 wide x 8.5 long 4 Filter / Regulator with Mounting Brackets Product Code SSF80-7 Suitable for ¾" & " units Component material 36 stainless steel. Brackets are supplied complete with fasteners. Note: Part number above is for single item. 36 Redefining Flow Control 29

3500 Series air service units Accessories for ¾" to " units - supplied separately Rear mounting bracket 45 20 28 70 2 - Ø8.5 Mounting Holes M8 20 9 2.6 92 Filter / Regulator with Rear Bracket Product Code SSAF638-26 Description Kit comprises of mounting bracket and 2 - M8 x2 cap head screws. All material stainless steel. 30

3575 Series air service units /2 to 2 Filter Regulators A 36L stainless steel combined unit for filtration and regulation of compressed air and gases for the actuation industries. Features and Benefits Specifically designed for severe environments Self-relieving Manual or auto-drain 25 micron element stainless steel 36 Ambient temperature range -20 to +80 ºC (-4 to +76 ºF) 36L stainless steel construction Mounting brackets supplied fitted as standard Gauge supplied fitted as standard Regulated pressure range from 0.50 to 2.0 bar depending on model selection Option available to supply without pilot regulator (consult factory for product code) Large flow paths (up to 45 Cv) NACE capability option available Units ordered with a specified pressure range will be supplied complete with a pilot regulator and piped using double ferrule fittings. Ports NPT (BSP option available - consult factory for part codes) /2, 2 Gauge Ports /8 NPT (fitted with gauge) Relief Vent Port /2 NPT (fitted with breather) Maximum Relief Flow At 2 bar (29 psi) secondary pressure 0.5 cc/sec (0.03 cu in/sec) Flow At 0 bar (45 psi) supply pressure, 6 bar (87 psi) secondary pressure, bar (4.5 psi) pressure drop. 2-45,000 l/min (,590 SCFM) Bowl Capacity 2 cc (.28 cu ins) Operating Media Gases - air, inert gas, sour gases - NACE compliant Construction Materials Body/bonnet/bowl and internals: 36L stainless steel Element: 25 micron 36 stainless steel Seals: Nitrile Redefining Flow Control 3

3575 Series air service units /2 to 2 Filter Regulators - Engineering Drawings 48 394 00 80 Pressure Gauge 209 80 8.5 6 00 ½ or 2 NPT Ports 47 (Manual Drain) 235 (Auto Drain) Manual Drain ½ NPT Relief Port 3 Self-Relieving with auto drain Self-Relieving with manual drain 376 Product Code Size Filter Regulated Pressure bar (psi) Max Inlet Pressure bar Weight kg 7FRMSN022 ½" 38 Manual Drain 20 9FRMSN022 2" 0.50 to 2.0 45 7FRASN022 ½" (7.2 to 29) 38 Auto Drain 7 9FRASN022 2" 45 7FRMSN042 ½" 38 Manual Drain 20 9FRMSN042 2" 0.50 to 4.0 45 7FRASN042 ½" (7.2 to 58) 38 Auto Drain 7 9FRASN042 2" 45 9 7FRMSN082 ½" 38 Manual Drain 20 9FRMSN082 2" 0.50 to 8.0 45 7FRASN082 ½" (7.2 to 6) 38 Auto Drain 7 9FRASN082 2" 45 7FRMSN22 ½" 38 Manual Drain 20 9FRMSN22 2" 0.50 to 2.0 45 7FRASN22 ½" (7.2 to 74) 38 Auto Drain 7 9FRASN22 2" 45 Cv 32

3575 Series air service units /2 to 2 Filter A 36L stainless steel compressed air filter, designed to provide clean air for the actuation industries. Features and Benefits Specifically designed for severe environments Manual or auto-drain 25 micron element stainless steel 36 Ambient temperature tange -20 to +80 ºC (-4 to +76 ºF) 36L stainless steel construction Mounting brackets supplied fitted as standard Large flow paths (up to 45 Cv) NACE capability option available Ports NPT (BSP option available - consult factory for part codes) /2, 2 Flow At 6 bar (87 psi) supply pressure, bar (4.5 psi) pressure drop. 2-45,000 l/min (,590 SCFM) Bowl Capacity 2 cc (.28 cu ins) Operating Media Gases - air, inert gas, sour gases - NACE compliant Construction Materials Body/bonnet/bowl and internals: 36L stainless steel Element: 25 micron 36 stainless steel Seals: Nitrile Product Code Size Filter Max Inlet Pressure bar Weight kg Cv 8.7 38 7FLMSN202 /2 Manual 20 9FLMSN202 2 Drain 8.7 45 7FLASN72 /2 Auto 8.7 38 7 9FLASN72 2 Drain 8.7 45 Redefining Flow Control 33

3575 Series air service units /2 to 2 Filters - Engineering Drawings 220 00 80 96 80 8.5 00 89.4 3 50 6 ½ or 2 NPT Ports 47 (Manual Drain) 235 (Auto Drain) Manual Drain 0.4 4 - M0 Alternative mounting holes Filter with auto drain Filter with manual drain 78 34

3575 Series air service units /2 to 2 Pressure Regulators A 36L stainless steel unit for pressure regulation of compressed air and gases for the actuation industries. Features and Benefits Specifically designed for severe environments Self-relieving Ambient temperature range -20 to +80 ºC (-4 to +76 ºF) 36L stainless steel construction Mounting brackets supplied fitted as standard Gauge fitted as standard Regulated pressure range from 0.50 to 2.0 bar depending on model selection Large flow paths (up to 45 Cv) Option available to supply without pilot regulator (consult factory for product code) NACE capability option available Units ordered with a specified pressure range will be supplied complete with a pilot regulator piped using double ferrule fittings. Ports NPT (BSP option available - consult factory for part codes) /2, 2 Gauge Ports /8 NPT (fitted with gauge) Relief Vent Port /2 NPT (fitted with breather) Maximum Relief Flow At 2 bar (29 psi) secondary pressure 0.5 cc/sec (0.03 cu in/sec) Flow At 0 bar (45 psi) supply pressure, 6 bar (87 psi) secondary pressure, bar (4.5 psi) pressure drop. 2-45,000 l/min (,590 SCFM) Operating Media Gases - air, inert gas, sour gases - NACE compliant Construction Materials Body/bonnet/bowl and internals: 36L stainless steel Seals: Nitrile Product Code Size Regulated Pressure Max Inlet Pressure bar Weight kg 7PRVSN022 ½" 38 0.50 to 2.0 bar (7.2 to 29 psi) 9PRVSN022 2" 45 7PRVSN042 ½" 38 0.50 to 4.0 bar (7.2 to 58 psi) 9PRVSN042 2" 45 20 7PRVSN082 ½" 38 0.50 to 8.0 bar (7.2 to 6 psi) 9PRVSN082 2" 45 7PRVSN22 ½" 38 0.50 to 2.0 bar (7.2 to 74 psi) 9PRVSN22 2" 45 Cv Redefining Flow Control 35

3575 Series air service units /2 to 2 Pressure Regulators - Engineering Drawings 220 96 00 80 Pressure Gauge 3 96 209 80 8.5 00 6 ½ NPT Relief Port ½ or 2 NPT Ports Self Relieving 78 36

Over Pressurisation Device OPD A 36L stainless steel unit providing protection to downstream equipment from over pressure events. Features and Benefits Protection of equipment from regulator failure and over pressure events Specifically designed for severe environments Manifold mounted option Auto shut-off ¼ turn actuator and on/off valve protection Linear actuator and control valve protection System instrumentation equipment protection Process valve stem & seat saver Easy installation 36L stainless steel construction Compliments and protects ESD & safety instrumented system equipment Ambient temperature range -20 to +80 ºC (-4 to +76 ºF) Low temperature option available Regulated outlet pressure range 4-8 bar Trip Pressure Range 4.5-8.5 bar (4-8 bar) Maximum Response Time 30 ms (4-8 bar) Temperature Range Standard: -20 to +80 ºC (-4 to +76 ºF) Low temp: -50 to +90 ºC (-58 to +94 ºF) optional Maximum Inlet Pressure Manual drain: 20 bar Auto drain: 7 bar Product Code (Manual Drain) Product Code (Auto Drain) Size Weight kg 4OPDSVX23XX XXA 4OPASVX23XX XXA ½ 3.3 Customer to specify trip pressure Customer to specify set pressure Factory to determine via customer set & trip pressure Redefining Flow Control 37

Over Pressurisation Device OPD General Description The purpose of the OPD is to protect downstream equipment from over pressure events including regulator failure, thus preventing potential damage and downtime. Applications include the protection of ESD & Safety Instrumented Systems including positioners, actuators and process valve stems. The device includes a pressure regulator with a protection valve and sensor system. Increases in outlet pressure can occur for many reasons, including failure of key regulator components or misadjustment. Should this occur the device will automatically fail-safe within 30 milli-seconds. The protection valve will be triggered to shut-off the outlet and vent the downstream pressure. When the protection valve has deployed, the reset button protrudes from the housing providing a positive indication that a fault has occurred. The OPD reduces the potential for damage occurring from increased torque, thrust or pressure values within the downstream system. Once the fault has been corrected the unit can be reset by pushing the reset button on the unit. In line with today s requirements for space saving, weight reduction and efficiency the system is all close coupled within a compact body. Development Failures of pressure regulators can result in the over pressurisation of the downstream line, as the self-relieving capacity of the regulator is insufficient to cope with major failures. Usually a relief valve of sufficient capacity is fitted into the system to hold the pressure down to an acceptable level. However a relief valve flow is sized on a pressure differential between set pressure and over pressure, usually 0%. Thus on a set pressure of 4.5 barg a pressure rise to 4.95 barg would have to flow sufficiently to hold the pressure at 4.95 barg, against the flow through a failed pressure regulator. At 0 barg supply pressure the flow through the failed pressure regulators will be driven by a 0 to 4.95 i.e. 5.05 barg pressure drop. In many cases this would result in damage to sensitive & expensive equipment such as positioners, actuator diaphragms and process valve stems. An alternative is to fit an excessively large relief valve(s), which in itself could cause serious problems by dumping all of the systems air and starving other equipment resulting in plant shutdown and potential compressor damage. Considered Regulator Failure modes Failure modes are common to all manufacturers regulators unless specific design changes have been made to cope with them. Therefore to overcome these difficulties the Over Pressurisation Device was designed and engineered. Typical Regulator Failure Modes Misuse and maladjustment during installation and commissioning. Rupture of diaphragm leading to total loss of pressure regulation. Failure of regulator seat leading to partial or total loss of pressure regulation. Blocking of the regulator relief port leading to total loss of pressure regulation. 38

Over Pressurisation Device OPD Performance Characteristics Response times are dependant upon the actual pressures within the system at the point of failure; all times stated within the specification section are maximums taken at the lowest extreme of the pressure range (worst case). 20.0 B 6.0 2.0 8.0 4.0 0.0-4.0 2-8.0-3.6ms -8.9ms 22.7ms -2.0 4.49 B 5. B 620.0 mb -6.0-20.0-00.0-75.0-50.0-25.0 0.0 25.0 50.0 75.0 00.0 25.0 50.0 20.0 B 6.0 2.0 8.0 4.0 0.0-4.0-8.0-2.0-6.0 2-73.ms -62.6ms 0.5ms 3.88 B 3.97 B 90.0 mb 20.0 B 6.0 2.0 8.0 4.0 0.0-4.0-8.0-2.0-6.0-20.0 20.0 B 6.0 2.0 8.0 4.0 0.0-4.0-8.0-2.0-6.0-20.0-20.0-20.0-00.0-80.0-60.0-40.0-20.0 0.0 20.0 40.0 60.0 80.0 The magnitude of any pressure spikes exceeding the trip pressure which occur during deployment of the valve are dependant upon the system downstream volume; a larger system volume decreases the likelihood of the system pressure exceeding the trip pressure (see graphs). Any pressure spikes which do occur will only do so for a fraction of a second (less than the time taken for the device to operate). Small actuator test results. 4-8 bar OPD; outlet connected to a volume of 0.2 litres Trigger Test: Blue = Simulated actuator pressure (bar) Red = Supply pressure (bar) The graph to the left is an overpressure test result with a small 0.2 litre reservoir to simulate the actuator. An overpressure signal is applied allowing the barg supply pressure to bypass the regulator, simulating a ruptured diaphragm. The response time of the device is measured as the time between the pressure within the device reaching the trip pressure and the actuator pressure returning to below the regulated pressure (see dashed lines on graph & right hand column of table). Larger actuator test results. 4-8 bar OPD; outlet connected to a volume of 3 litres Trigger Test: Blue = Actuator pressure (bar) Red = Supply pressure (bar) The graph above is an overpressure test result with a larger 3 litre reservoir to simulate the actuator. An overpressure signal is applied allowing the barg supply pressure to bypass the regulator, simulating a ruptured diaphragm. The response time of the device is measured as the time between the pressure within the device reaching the trip pressure and the actuator pressure returning to below the regulated pressure (see dashed lines on graph & right hand column of table). Note: During this test the actuator pressure does not exceed the trip pressure value. Test Circuit OPD 6 Barg Supply 0 Barg 0-40 barg gauge 4 Barg Over pressure valve Operating poppet valve 0.2 litre Isolation Valve 0 Barg Detent /4 turn ball valve overpressure Redefining Flow Control 39

Over Pressurisation Device OPD - Engineering Drawings 4-8 Bar 7 Trip Pressure Adjuster C/W Tamperproof Cap Relief Port 04.5 28.5 Manual Drain With Tamperproof Cap 2.5 3.0 Reset Button Gauge Port (Front & Back) 28.0 64.5 Auto-Drain 8.5 Manual Drain Auto-Drain Port 6 Exhaust Port 28.5 65 40

Oil & Gas industries Since our founding in 956, we have been known internationally as one of the oil & gas industries premier designers and manufacturers of 36L stainless steel control equipment. Over the years we have developed an enviable reputation for high quality products, reliability and innovation. We have the ability to investigate problems and provide comprehensive solutions for the control of hydraulic and pneumatic actuated process control valves across a broad range of industries and markets. This, coupled with repeatedly delivering impressive results worldwide, sets us apart from our competitors. Rotork Instruments are experts in flow control, pressure control, flow measurement and pressure measurement. We manufacture products and components that are trusted for applications where high precision and reliability are required. Rotork Instruments has manufacturing facilities in USA, Italy, Brazil, India, China and Singapore. The Rotork global sales and service network supports all Rotork Instruments products. This network is the biggest global actuation support organisation in the world with direct sales offices and agents in all industrialised countries. Customer service and field support provides quick and effective response to customer requirements. The Rotork Site Services network is represented throughout the world and provides valuable service and assistance to all industries. Redefining Flow Control 4

Service and Support Client Support Programme Rotork staff are dedicated to providing client support across all Rotork divisions with the aim of maximising the client production cycle. These teams are based out of service centres around the world and are complemented by factorytrained agents. Our expert technicians support Rotork customers, allowing us to deliver on our promise of global solutions backed by local service. We provide a full range of flow control services: Emergency and planned service Actuator overhauls Health checks Preventative maintenance Retrofitting actuators to existing valves Shutdown outages Certified inspection and safety checks Factory fitting of actuators to new valves Plant optimisation Repairs and upgrades Loan actuator service System Integration projects Automation projects Visit www.rotork.com to identify your nearest Rotork Site Services centre. Rotork offers a premium level of product reliability and availability through the flexible Client Support Programme (CSP). Designed to facilitate the highest production demands while providing a tiered approach to maintenance, the CSP is committed to reducing maintenance downtime and costs. Through consultation, the CSP is tuned to deliver the optimum level of maintenance through predictive maintenance algorithms. Features of the CSP are: Fixed term prices for Rotork products and services Customisable cover based on equipment criticality to production Equipment performance related targets for reliability and availability Priority support with customisable response times Fully parts and labour inclusive, no additional costs or discounted labour and parts Fix or replace options Periodic equipment performance and status reports Built-in regular health checks on all equipment Benefits of the CSP include but are not limited to: Year-on-year reduced maintenance costs Easy budget management Maximised production resulting in reduced downtime Year-on-year improved reliability and availability Optimised resource usage to accelerate in-house projects Reduced lifecycle costs 0225 733284 service@rotork.co.uk 42

Service and Support Preventative maintenance To maximise plant up-time and minimise operating costs we offer clients a range of preventative maintenance programmes. We tailor the service in every case to reflect the type of actuators in service, the availability of asset information and the criticality of the plant. Automation projects This is a growing requirement and some of our service teams have the wide range of skills necessary to offer a one-stopshop to automate part or all of a customer s process. Our capabilities cover all of the installation phases (scoping, design, procurement, manufacturing, installation, commissioning) on the broad scopes that typically surround actuation projects. Emergency and planned service We provide a full range of actuator services, covering any type of actuator in any location, including hazardous environments. Our services include installation, commissioning and upgrading as well as connection and installation of bus communication systems. We are also skilled at troubleshooting and repairing damaged or deteriorating assets. Depending on your requirements, we can offer guaranteed emergency response times or planned response. Health checks To help customers understand the state of their plant and assets, to better inform maintenance and replacement decisions, we offer full inspection and reporting. In addition to a detailed and intrusive inspection of the actuators, we offer extra insights from our original factory build data. Retrofitting actuators to existing valves We have extensive experience in fitting actuators to valves, penstocks and dampers that are already installed as part of existing plant. Whether customers are replacing obsolete actuators, changing power sources or motorising manual valves, we offer a tailor made solution to meet customers specific requirements. Actuator overhauls After a long service life it is sometimes preferable to overhaul rather than replacing actuators. In our workshops we completely strip and rebuild actuators, returning them to their original state. Shutdown outages For those customers who run tightly-scheduled shutdowns, we engage closely in the project to help meet demanding deadlines. A typical example might involve our staff removing large numbers of actuators, overhauling them in our workshops and re-commissioning them as part of the maintenance of a larger unit. Factory fitting of actuators to new valves The careful assembly of valve and actuator is critical to ensure that an automated valve performs correctly and reliably. Whilst this service is often carried out by valve manufacturers, if there is a need we can provide this service. Redefining Flow Control 43

Redefining Flow Control www.rotork.com A full listing of our worldwide sales and service network is available on our website. Rotork Midland Ltd. Patrick Gregory Road Wolverhampton WV 3DZ, UK tel +44 (0)902 305 678 fax +44 (0)902 305 676 email sales.midland@rotork.com Scan with your smart phone for more information on this product range PUB7-00-00 Issue /4 As part of a process of on-going product development, Rotork reserves the right to amend and change specifications without prior notice. Published data may be subject to change. For the very latest version release, visit our website at www.rotork.com The name Rotork is a registered trademark. Rotork recognises all registered trademarks. POWTG4. Published and produced in the UK by Rotork Controls Limited. Registered office: Rotork plc, Brassmill Lane, Bath, BA 3JQ, UK.