Tube for General Pneumatic Piping

Similar documents
Insert Ring. Protection Ring from Tube Deformation. Protect tubes from deformation. Ultra soft tube is connectable to Fitting.

Anti-spatter Tube. Spatter-Proof Tube for Pneumatic Piping. Polyamide type Tube Coated with Flame-Retardant Resin(Equivalent to V-0 )

Coiling Tube Series. Coiling Tube for General Pneumatic Piping. Coiling Tube for General Pneumatic Piping. Suitable for Air Gun or Air Driver.

Polyurethane Tube. Straight Tube for General Pneumatic Piping. Excellent in Flexibility. Suitable for Compact Piping Requiring Small Bending Radius

Static dissipative Resin (Surface Resistivity : 10 4 ~10 7 Ω).

Tube for Clean Environment Polyurethane Tube Clean-Room Package

Multi Core Tube for General Pneumatic Piping

Tube Cutter with Measuring tape built-in

Coiling Tube with Twist-Proof Fitting

Change Valve. Push-In Fitting Type Three-way Changeover Valve. Changeover Air Direction by 90. Lightweight and Compact Design.

Push-In Fitting Type Silencer

Push-In Fitting Type Pressure Gauge

Push-In Fitting Type with Stop Valve

Hand Valve Series. Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Control Open/Close for Air Supply.

Pressure Gauge Series

Speed Controller Anti-spatter Series

Speed Controller Constant Flow

Ball Valve Series. Push-In Fitting Type Shut-off Valve. Control Open/Close Air Supply. Ensure Effective Area for Variety of Tube Dia.

(1) Name of tube (2) Tube dia. (O.D./I.D.) (3) Tube length. (4) Tube color. Model UD0425. UD1290 O.D. I.D. (mm) UD1075 UD0860 UD

Suitable for Semi-Conductor, Measuring Instrument, Printing and Medical Industries

Cautions : 1. Be careful when you release the Stop Fitting with some internal pressure

(1) Type. (2) Tube dia. (ød) : ø8mm (ø5/16in.) (3) Thread size (T) (4) Specification. Fluid medium. Air, water * 1, * 2, * 3 Max. operating pressure

Cautions : 1. Clogging of the element raises resistance to exhaust, thus lowering the

Die Temperature Control Fitting Series

(1) Type (2) Thread size (T) (3) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R)

Pad Swinging Attachment

Cautions : 1. The gauge orientation on the GPU and GPM types can be changed by using

Ejector for Conveying particles, powder and fibers Vacuum GeneratorVRL

(1) Type (2) Cylinder dia. (3) Gripper action : Single-acting closing gripper (normally open) (4) Holder type

Model PCøD-TSUS PC4-M6SUS PC4-01SUS PC4-02SUS PC6-M5SUS PC6-M6SUS PC6-01SUS PC6-02SUS PC16-03SUS

(2) Effective sectional area (no code for mini type) (3) Intake-side shape (no code for mini type) : Quick-fitting joint type : Taper pipe thread type

Model SPCøD-T SPC4-M5 SPC4-M50 * 1 SPC4-M6 SPC4-02 SPC6-M5 SPC6-M6 SPC6-01 SPC6-02 SPC16-03

(1) Union Filter for positive and negative pressure (2) Filter size. (3) Tube dia. (4) Holder option : without Holder : with Holder

The plastic bowl guard does not corrode. The draining method is selectable between the push type and the auto drain type.

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6

(1) Type (2) Tube dia. (ød(1)) (3) Thread size (T) (4) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R)

The products listed in this page are ECO-friendly products. * Please refer to page 4 for the details of ECO-friendly products. Model UAMR AD- L

Pilot Check Valve: Metal Body Type

SeriesTRBU. Flame Resistant (Equivalent to UL-94 Standard V-0) FR Double Layer Polyurethane Tubing

Series AS-FPQ/AS-FPG. Speed Controller with One-touch Fitting for Clean Room. Speed controllers for clean room use

(1) (2) (3) (4) No indicator type Digital pressure sensor with large display 30mm negative pressure gauge Air

Recommended applicable tubing. Specifications. Operating vacuum pressure. 20 C to 80 C Threads. Principal parts material

Small Vacuum Regulator Series

4-63 T UBE FITTINGS TUBING P OLYURETHANE TUBING SERIES TU P RODUCTS FOR A LIST OF STOCKED PRODUCTS, PLEASE SEE THE CURRENT SMC PRICE LIST S TOCKED

(1) Size (Overall dimensions: H W) (2) Bending radius. (3) Body color : Black : Ivory (102, 202, 203, 204, 206 only)

(1) Size (Overall dimensions: H W) (2) Bending radius. In case of ordering, please apply Model code in the following chart. H HF K a.

Industrial Filter. FGD series

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

ROTARY JOINTS NHRC Structural Diagram

Related Products: Auto Drain Valve. Model/Specifications. Model

reduces flow setting time and setting errors!

10 - TU0425 BU Color B Black W White R Red BU Blue Y Yellow G Green C Clear YR Orange. Tubing model. Inch size (Series TIUB) Model 3.

Operation Manual Air Saver Unit ASV5000 Series

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

CHECK VALVES GPCVC Structural Diagram

Specifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Flame resistant style

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

Clean Speed Controller with One-touch Fitting

Miniature Tubing & Miniature Fittings

Vacuum Saving Valve Series ZP2V How to Order ZP2V A5 03 Connection thread symbol for the pad Male thread connection Symbol Thread Applicable fixed ori

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

SEALED CONNECTORS FOR THE LIMIT SWITCHES

Direct Operated Precision Regulator Modular Style. Standard Specifications

PN LINE. Technical remarks PN 11 PN 13 PN 14 PN 15 PN 17 PN 18 PN 20 PN 23 PN 25 PN 26 PN 27 PN 28 PN 29 PN 37 PN 38 PN 39 PN 40 PN 43 PN 10 8_9 10_12

Series AMJ. Drain Separator for Vacuum

Air operated valve. VGA342R Series

Series ZFC. Air Suction Filter In-line Type with One-touch Fittings

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Specifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Standard style

// ADapters GUIDelines

PVC Quick Drain Valve

No.IL02-OM00011-A PRODUCT NAME LOCK UP VALVE. MODEL/ Series IL201 IL211

Installation, operation & maintenance manual - original version

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Installation, Operation and Maintenance Manual for Back Pressure Regulator

ALF400 to 900, ALT-5/-9

30% (SMC comparison) Silencer. New. New. The M5 silencer is now added! The resin silencer is now a more compact size! Series AN.

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

Specifications. JIS Symbol 2 port valve 3 port valve (A) 2 (A) 2. Construction. 2 port valve/series VHK2 3 port valve/series VHK3.

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Pressure Relief 3 Port Valve New. Sonic Conductance 45% With the indicator window Step1. With locking holes

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

OWNER S MANUAL. This manual contains; IMPORTANT SAFETY INFORMATION INSTALLATION INSTRUCTIONS MAINTENANCE FACTORY SERVICE REPAIR PARTS WARRANTY

COMPRESSION TUBE FITTINGS

Low torque Metal seal type Rotary joint

J138RSH and J150RSH 3/8" J138RSH 1/2" J150RSH. 3/8" Drive Sealed Head Ratchet 1/2" Drive Sealed Head Ratchet. Operation and Maintenance Manual WARNING

BUTTERFLY VALVES Series 800

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Automatic Non-freeze Valve NF6

COMPRESSION TUBE FITTINGS

Gas Welding Hoses and connections, the weak link

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Straight-Way Valve with Packing Gland

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Manual Brass Shut-Off Valve DN10 through DN22

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING

Series variation. Silencer. High damping effect and 2 types of materials. Applicable cylinder bore size (mm) Effective sectional area (mm 2 )

Air Saving Valve. Pressure Valve Flow Valve

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

Air Saving Valve reduction in 40% air consumption 40% air consumption Air consumption reduction ratio (%) Flow valve Flow valv

Port size. Model Screw-in ZFA10 1/8 ZFA20 1/4 ZFB10 ZFB20 ZFB30 ZFB40 ZFC5 ZFC7

Transcription:

http://www.pisco.co.jp TUBE MAKE-TO-ORDER PRODUCTS for General Pneumatic Piping 608 Standard Fine Pressure, Wear, and Cold Resistance. NB for Hot Water and Thermal Oil. Multi-core Coiling Twin Coiling Fluororesin / Polyamide Excellent Bending Fatigue Resistance. Stably Usable for Long Time. Clean Room 12 Color Selections for NB. 9 Color Selections for NA. Marking on every 500mm to cut conveniently. 500mm 500mm Cutting mark Cutting mark Cutting mark Longer Length is available. (Make-to-Order) Anti-Spatter Anti-Stalic Binder cutter Insert Ring Reel

Series Nylon Series TUBE VALVE CONTROLLER FITTING Model Designation (Example) 2 dia. (O.D. x I.D.) 1 type 1 type NA : Nylon NB : Soft Nylon 2 dia. mm size inch size Code 0425(5/32) 0640 0860(5/16) 1075 1290 1613(5/8) 1/8 3/16 1/4 3/8 1/2 O.D. (mm) ø4 ø6 ø8 ø10 ø12 ø16 ø3.18 ø4.76 ø6.35 ø9.53 ø12.7 I.D. (mm) ø2.5 ø4 ø6 ø7.5 ø9 ø13 ø2 ø2.99 ø4.57 ø6.99 ø9.56 There is no inch size selection for NB as a standard item. 4 color 3 length 609 Standard 3 length Code 20 100 Length(m) 20 100 NA1613 (5/8) and NB1613 are available only with 20m length. 4 color code B R O YB Y G Bu CB W BR YG P Color Black Red Orange Ocher Yellow Green Blue Clear blue Milky white Brown Yellow green Pink N mm size A inch size NB Standard colors for inch sized NA 1/8, 3/16, 1/4, 3/8 and 1/2 are Black and Milky white. Standard colors for NB1613 are Black, Blue and Milky white. Other colors are available as a make-to-order product. Color selection with marking is available as a make-to-order product. MOQ is 500m. Make-to-order product diameter / Length list Model code Reel Bundle (small) Bundle (large) 2 mm size inch size (m reel) (m reel) (m reel) NA0425, NB0425 NA1/8, NA5/32, NA3/16 500 500 NA0640, NB0640 NA1/4 500 500 NA0860, NB0860 NA5/16 200 200 500 NA1075, NB1075 NA3/8 150 150 300 NA1290, NB1290 NA1/2 100 100 300 NA1613, NB1613 NA5/8 50 50 200 1. MOQ of make-to-order tube is 500m. 2. Bundle (large) is packed on a pallet. Contact the nearest sales office for the freight charge.

http://www.pisco.co.jp Specifications type NA NB Fluid medium Air / Water ( 1-3) Air / Water / Thermal oil ( 1-3) Max. operating pressure (at 20 65%RH) 1.5MPa ( 4) 1.0MPa ( 4) Max. vacuum Operating temp. range -100kPa -15 90 (No freezing) Warning 1. Surge pressure must be controlled lower than max. operating pressure when using water (and thermal oil for NB ) as a fluid medium. 2. Tap water can be used. Consult with PISCO for using other kind of water. 3. Be sure to place Insert Ring into the tube edge when is inserted into Push-In Fittings with water (and thermal oil for NB ) as a fluid medium. 4. The value of max. operating pressure is measured at 20 and 65%RH. When s are used in different conditions, consider a safety ratio of the pressure with an enough margin referring to Burst Pressure Curve. TUBE Burst Pressure Curve (Reference value) 18 MAKE-TO-ORDER PRODUCTS Burst pressure(mpa) 16 14 12 10 8 6 4 2 NB1613 NA0425, NA0640 NA0860, NA1075, NA1290 NA1613 NB0425, NB0640 NB0860, NB1075, NB1290 0-15 0 20 40 60 80 90 Operating temperature( ) 610 Standard Multi-core Coiling Twin Coiling Fluororesin / Polyamide Clean Room Detailed Safety Instructions Before using PISCO products, be sure to read Safety Instructions and Safety Instruction Manual on page 23 to 27 and Common Safety Instructions for s on page 593 to 594. Caution 1. Due to the nature of the products, some tube additives contained in material may bleed on the surface of Nylon Series as time elapses. Anti-Spatter Anti-Stalic Binder cutter Insert Ring Reel

Series Nylon Series TUBE VALVE CONTROLLER FITTING NA compliant Model code Nylon O.D. (ømm) I.D. (ømm) length (m) Min. Bending Radius (mm) Min. Installation Radius (mm) NA 0425(5/32)- - 4 2.5 NA 0640- - 6 4 NA 0860(5/16)- - 8 6 NA 1075- - 10 7.5 NA 1290- - 12 9 NA 1613(5/8)-20-16 13 NA 1/8- - 3.18 2 NA 3/16- - 4.76 2.99 NA 1/4- - 6.35 4.57 NA 3/8- - 9.53 6.99 NA 1/2- - 12.7 9.56. Left in model code : Replace with length. Right in model code: Replaced with color code Weight (g/m) B Black R Red O Orange YB Ocher Y Yellow G Green Bu Blue CB Clear blue W Milky white 611 NB compliant Soft Nylon Standard Model code O.D. (ømm) I.D. (ømm) length (m) Min. Bending Radius (mm) Min. Installation Radius (mm) Weight (g/m) B R O YB Y Black Red Orange Ocher Yellow Green G Bu Blue CB Clear blue W YG Milky BR Yellow white Brown green NB 0425- - NB 0640- - NB 0860- - NB 1075- - NB 1290- - NB 1613-20-. Left in model code : Replace with length. Right in model code: Replaced with color code P Pink

Safety Instructions SAFETY Instructions This safety instructions aim to prevent personal injury and damage to properties by requiring proper use of PISCO products. Be certain to follow ISO 4414 and JIS B 8370 ISO 4414:Pneumatic fluid power Recomendations for the application of equipment to transmission and control systems. JIS B 8370:General rules and safety requirements for systems and their components. This safety instructions is classified into Danger, Warning and Caution depending on the degree of danger or damages caused by improper use of PISCO products. Danger Warning Caution Hazardous conditions. It can cause death or serious personal injury. Hazardous conditions depending on usages. Improper use of PISCO products can cause death or serious personal injury. Hazardous conditions depending on usages. Improper use of PISCO products can cause personal injury or damages to properties. 23 Warning 1. Selection of pneumatic products 1 A user who is a pneumatic system designer or has sufficient experience and technical expertise should select PISCO products. 2 Due to wide variety of operating conditions and applications for PISCO products, carry out the analysis and evaluation on PISCO products. The pneumatic system designer is solely responsible for assuring that the user's requirements are met and that the application presents no health or safety hazards. All designers are required to fully understand the specifications of PISCO products and constitute all systems based on the latest catalog or information, considering any malfunctions. 2. Handle the pneumatic equipment with enough knowledge and experience 1 Improper use of compressed air is dangerous. Assembly, operation and maintenance of machines using pneumatic equipment should be conducted by a person with enough knowledge and experience. 3. Do not operate machine / equipment or remove pneumatic equipment until safety is confirmed. 1 Make sure that preventive measures against falling work-pieces or sudden movements of machine are completed before inspection or maintenance of these machine. 2 Make sure the above preventive measures are completed. A compressed air supply and the power supply to the machine must be off, and also the compressed air in the systems must be exhausted. 3 Restart the machines with care after ensuring to take all preventive measures against sudden movements.. This safety instructions are subject to change without notice.

http://www.pisco.co.jp Disclaimer 1. PISCO does not take any responsibility for any incidental or indirect loss, such as production line stop, interruption of business, loss of benefits, personal injury, etc., caused by any failure on use or application of PISCO products. 2. PISCO does not take any responsibility for any loss caused by natural disasters, fires not related to PISCO products, acts by third parties, and intentional or accidental damages of PISCO products due to incorrect usage. 3. PISCO does not take any responsibility for any loss caused by improper usage of PISCO products such as exceeding the specification limit or not following the usage the published instructions and catalog allow. 4. PISCO does not take any responsibility for any loss caused by remodeling of PISCO products, or by combinational use with non-pisco products and other software systems. 5. The damages caused by the defect of Pisco products shall be covered but limited to the full amount of the PISCO products paid by the customer. 24

Safety Instructions 25 SAFETY INSTRUCTION MANUAL PISCO products are designed and manufactured for use in general industrial machines. Be sure to read and follow the instructions below. Danger 1. Do not use PISCO products for the following applications. 1 Equipment used for maintaining / handling human life and body. 2 Equipment used for moving / transporting human. 3 Equipment specifically used for safety purposes. Warning 1. Do not use PISCO products under the following conditions. 1 Beyond the specifications or conditions stated in the catalog, or the instructions. 2 Under the direct sunlight or outdoors. 3 Excessive vibrations and impacts. 4 Exposure / adhere to corrosive gas, inflammable gas, chemicals, seawater, water and vapor. * * Some products can be used under the condition above(4), refer to the details of specification and condition of each product. 2. Do not disassemble or modify PISCO products, which affect the performance, function, and basic structure of the product. 3. Turn off the power supply, stop the air supply to PISCO products, and make sure there is no residual air pressure in the pipes before maintenance and inspection. 4. Do not touch the release-ring of push-in fitting when there is a working pressure. The lock may be released by the physical contact, and tube may fly out or slip out. 5. Frequent switchover of compressed air may generate heat, and there is a risk of causing burn injury. 6. Avoid any load on PISCO products, such as a tensile strength, twisting and bending. Otherwise, there is a risk of causing damage to the products. 7. As for applications where threads or tubes swing / rotate, use Rotary Joints, High Rotary Joints or Multi-Circuit Rotary Block only. The other PISCO products can be damaged in these applications. 8. Use only Die Temperature Control Fitting Series, Fitting Stainless SUS316 Series, Fitting Stainless SUS316 Compression Fitting Series or Fitting Brass Series under the condition of over 60 (140 F) water or thermal oil. Other PISCO products can be damaged by heat and hydrolysis under the condition above. 9. As for the condition required to dissipate static electricity or provide an antistatic performance, use EG series fitting and antistatic products only, and do not use other PISCO products. There is a risk that static electricity can cause system defects or failures. 10. Use only Fittings with a characteristic of spatter-proof such as Antispatter or Brass series in a place where flame and weld spatter is produced. There is a risk of causing fire by sparks. 11. Turn off the power supply to PISCO products, and make sure there is no residual air pressure in the pipes and equipment before maintenance. Follow the instructions below in order to ensure safety. 1 Make sure the safety of all systems related to PISCO products before maintenance. 2 Restart of operation after maintenance shall be proceeded with care after ensuring safety of the system by preventive measures against unexpected movements of machines and devices where pneumatic equipment is used. 3 Keep enough space for maintenance when designing a circuit. 12. Take safety measures such as providing a protection cover if there is a risk of causing damages or fires on machine / facilities by a fluid leakage.

http://www.pisco.co.jp Caution 1. Remove dusts or drain before piping. They may get into the peripheral machine / facilities and cause malfunction. 2. When inserting an ultra-soft tube into push-in fitting, make sure to place an Insert Ring into the tube edge. There is a risk of causing the escape of tube and a fluid leakage without using an Insert Ring. 3. The product incorporating NBR as seal rubber material has a risk of malfunction caused by ozone crack. Ozone exists in high concentrations in static elimination air, clean-room, and near the high-voltage motors, etc. As a countermeasure, material change from NBR to HNBR or FKM is necessary. Consult with PISCO for more information. 4. Special option Oil-free products may cause a very small amount of a fluid leakage. When a fluid medium is liquid or the products are required to be used in harsh environments, contact us for further information. 5. In case of using non-pisco brand tubes, make sure the tolerance of the outer tube diameter is within the limits of Table 1. Table 1. O.D. Tolerance mm size Nylon tube Polyurethane tube inch size Nylon tube Polyurethane tube ø1.8mm ±0.05mm ø1/8 ±0.1mm ±0.15mm ø3mm ±0.15mm ø5/32 ±0.1mm ±0.15mm ø4mm ±0.1mm ±0.15mm ø3/16 ±0.1mm ±0.15mm ø6mm ±0.1mm ±0.15mm ø1/4 ±0.1mm ±0.15mm ø8mm ±0.1mm ±0.15mm ø5/16 ±0.1mm ±0.15mm ø10mm ±0.1mm ±0.15mm ø3/8 ±0.1mm ±0.15mm ø12mm ±0.1mm ±0.15mm ø1/2 ±0.1mm ±0.15mm ø16mm ±0.1mm ±0.15mm ø5/8 ±0.1mm ±0.15mm 6. Instructions for Insertion 1 Make sure that the cut end surface of the tube is at right angle without a scratch on the surface and deformations. 2 When inserting a tube, the tube needs to be inserted fully into the pushin fitting until the tubing edge touches the tube end of the fitting as shown in the figure below. Otherwise, there is a risk of leakage. 26 end Sealing is not fully inserted up to tube end. 3 After inserting the tube, make sure it is inserted properly and not to be disconnected by pulling it moderately.. When inserting tubes, Lock-claws may be hardly visible in the hole, observed from the front face of the release-ring. But it does not mean the tube will surely escape. Major causes of the tube escape are the followings; 1Shear drop of the lock-claws edge 2The problem of tube diameter (usually small) Therefore, follow the above instructions from 1 to 3, even lock-claws is hardly visible.

Safety Instructions 7. Instructions for Disconnection 1 Make sure there is no air pressure inside of the tube, before disconnecting it. 2 Push the release-ring of the push-in fitting evenly and deeply enough to pull out the tube toward oneself. By insufficient pushing of the releasering, the tube may not be pulled out or damaged by scratch, and tube shavings may remain inside of the fitting, which may cause the leakage later. 8. Instructions for Installing a fitting 1 When installing a fitting, use proper tools to tighten a hexagonal-column or an inner hexagonal socket. When inserting a hex key into the inner hexagonal socket of the fitting, be careful so that the tool does not touch lock-claws. The deformation of lock-claws may result in a poor performance of systems or an escape of the tube. 2 Refer to Table 2 which shows the recommended tightening torque. Do not exceed these limits to tighten a thread. Excessive tightening may break the thread part or deform the gasket and cause a fluid leakage. Tightening thread with tightening torque lower than these limits may cause a loosened thread or a fluid leakage. 3 Adjust the tube direction while tightening thread within these limits, since some PISCO products are not rotatable after the installation. Table 2: Recommended tightening torque / Sealock color / Gasket materials 27 Thread type Thread size Tightening torque Sealock color Gasket materials M3 0.5 0.7N m SUS304 M5 0.8 1.0 ~ 1.5N m NBR M6 1 2 ~ 2.7N m Metric thread M3 0.5 0.5 ~ 0.6N m M5 0.8 1 ~ 1.5N m M6 0.75 0.8 ~ 1N m POM M8 0.75 1 ~ 2N m R1/8 7 ~ 9N m Taper pipe thread R1/4 12 ~ 14N m R3/8 22 ~ 24N m White R1/2 28 ~ 30N m Unified thread No.10-32UNF 1.0 ~ 1.5N m SUS304 NBR 1/16-27NPT 7 ~ 9N m 1/8-27NPT 7 ~ 9N m National pipe 1/4-18NPT 12 ~ 14N m thread taper 3/8-18NPT 22 ~ 24N m White 1/2-14NPT 28 ~ 30N m These values may differ for some products. Refer to each specification as well. 9. Instructions for removing a fitting 1 When removing a fitting, use proper tools to loosen a hexagonal-column or an inner hex bolt. 2 Remove the sealant stuck on the mating equipment. The remained sealant may get into the peripheral equipment and cause malfunctions. 10. Arrange piping avoiding any load on fittings and tubes such as twist, tensile, moment load, shaking and physical impact. These may cause damages to fittings, tube deformations, bursting and the escape of tubes.

Series VALVE CONTROLLER FITTING Common Safety Instructions for s Before selecting or using PISCO products, read the following instructions. Read the detailed instructions for individual series as well as the instructions below. Warning 1. Avoid any load on s such as tensile strength, twisting and bending. These may cause the crush, burst and escape of s. TUBE 2. Protect s from scratches caused by snagging or kinking. It may cause the burst of s. 3. The burst pressure of s drops as temperature rises. Read the operating pressure in the catalog well, and apply safety factor. 4. The minimum bending radius and the minimum installation radius are reference values at 20 and 65% RH. They are not guaranteed values. Refer to the minimum bending radius when s are wound around a mandrel (round bar). As for the other operating conditions, refer to the minimum installation radius. These values vary depending on operating environments or the tube length. In order to make sure the suitability of s, carry out the operation test by the user's actual machine before using s. 593 5. Place Insert Ring into the edge of soft tubes like UD Series or tubes inserted to Push-In Fittings with a water fluid. There is a possibility of escape of without Insert Ring. 6. Only Anti-spatter can be used under the flame and weld spatter condition. Otherwise, there is a possibility of danger to catch fire by sparks. 7. Only Soft Nylon can be used for warm water or thermal oil. Otherwise, tubes may burst due to deterioration. 8. Only Anti-static can be used under the condition required to dissipate static electricity or provide an anti-static performance. There is a possibility that static electricity can cause malfunction or other troubles with the system. 9. An abnormal rise in temperature due to adiabatic compression may cause damage to s. 10. If s are used with any fluid or under any condition / environment other than listed in the catalog, as well as used outdoors, the conformity evaluation with the actual machine and safety measures taken by the responsible person are highly recommended.

http://www.pisco.co.jp Caution 1. When bending tubes, observe the minimum bending radius and minimum installation radius. 2. When piping, provide sufficient lengths of tube, considering possible shrinkage. 3. When s are inserted into Push-In Fitting, make sure that cut end surface of s are right angle, without any scratches on the surface and deformations. 4. Note that the effective cross-section area varies by tube length. Refer to Effective Area of Piping in Performance. TUBE Minimum Bending Radius & Minimum Mounting Radius 1. Measurement method Minimum Bend Radius (JIS method) JIS method (based on JIS B8381) Mandrel Minimum Bending Radius is measured by winding a tube tightly around a mandrel. ød Minimum Bending Radius is the value when the deformation ratio of the tube O.D. reaches ød 25%. Measurement condition: 20 65%RH L-D n= 1-100 2d n= Deformation ratio (%). Standard: under 25% d= O.D. L= Measured value (mm) D= Mandrel diameter (mm) L Minimum Installation Radius (Vice method) Fixed edge Vice width a 2R Moving edge Fix the tube as the left figure shows. Slowly move the moving edge toward the fixed edge. When a deforms 25% from the initial value, the measured R is Minimum Installation Radius. Measurement condition: 20 65%RH MAKE-TO-ORDER PRODUCTS 594 Standard Multi-core Coiling Twin Coiling Fluororesin / Polyamide Clean Room Anti-Spatter Anti-Stalic Binder cutter Insert Ring Reel

Series VALVE CONTROLLER FITTING TUBE Performance Effective Sectional Area of Piping Effective Sectional Area (mm 2 ) 1000 500 200 100 50 10 5 1 0.5 I.D. ø11 I.D. ø9 I.D. ø7.5 I.D. ø6.5 I.D. ø6(ø5.9) I.D. ø5 I.D. ø4 I.D. ø3.48 I.D. ø2.5(ø2.36) I.D. ø2 595 0.1 1 2 5 10 20 50 100 Piping length (m)