Compact Pressure Switch

Similar documents
Compact Pressure Switch

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

Series ZL. Multistage Ejector. New models! ZL212 large flow rate type and ZL112 with valve. ZX ZR ZM ZY ZH ZU ZL ZF ZP ZCU

Multistage Ejector Series ZL

Multistage Ejector Series ZL

Digital Flow Switch. Series PFM7

Technical Specifications

Digital electro-pneumatic regulators Series ER100

2/ Port G1/4

PSE Series. Remote Type Pressure Sensors/Pressure Sensor Controllers PSE550 ISE70 PS ISA3 ISA2 ISE35 PSE IS ISG ZSM1

1.0. ISE70/71 Series CAT.ES A. MPa/1.6 MPa. 3-Screen Display High-Precision Digital Pressure Switch. Angled display.

Vacuum Regulator. IRV10/20 Series. Weight reduced by. RoHS ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV

Series 10-IRV10/20. Vacuum Regulator C08 IRV C08 IRV 20 A. How to Order. Standard connections. Single sided connections. Accessory w Nil G ZN ZP ZA ZB

Compact Manometer. Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

For Air Pressure. AP-30 Series. Digital Display & Digital Control. EASY-TO-SEE 2-color display. Two-color digital display pressure sensor

DPS-400 SERIES DPH-100 SERIES

Pressure Sensor PSE53#

[Instruments for vacuum measurement, checking and adjustment] 3

Pressure Sensor/ PSE57 /PSE300AC Series CAT.ES A. 3-Screen Display Sensor Monitor. 500 VAC <Twice that of the PSE560> Remote Type

Pressure Sensor/ PSE57 /PSE300AC Series. 3-Screen Display Sensor Monitor 500 VAC. Remote Type. Change the settings while checking the measured value.

2-Color Display Digital Flow Switch

Pilot Check Valve: Metal Body Type

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

(1) (2) (3) (4) No indicator type Digital pressure sensor with large display 30mm negative pressure gauge Air

Installation, operating and maintenance Instructions for Seemag bypass level indicator

How to Order. Rc NPT 1/8 1/4 3/8 1/2

Series ZFC. Air Suction Filter In-line Type with One-touch Fittings

Series AMJ. Drain Separator for Vacuum

Pressure Sensor PSE54#

G1/8 G1/8. Model 0 bar -0,1 bar -0,2 bar -0,3 bar -0,4 bar -0,5 bar -0,6 bar -0,7 bar -0,8 bar

Slit Valve. XGT Series. Low particle generation. With end lock mechanism. Service life of two million cycles. XLA XL XL Q D- XSA XVD XGT CYV

COMPONENT SPECIFICATION M80-7XX SERIES CONNECTORS - THREE ROW

Pressure Sensor for General Fluids PSE56#

VACUUM REGULATORS CONTENTS

Pad Swinging Attachment

Proportional pressure regulators VPPE

MANUAL KPS Pressure Control Valve

Prewired position switches FA series

Ejector for Conveying particles, powder and fibers Vacuum GeneratorVRL

Precision Regulator. Series Model Regulating pressure range Port size Page

Wide opening parallel grippers Series CGLN

Space Saving Vacuum Ejector & Vacuum Pump System

ALL-IN-ONE MINI THERMAL MASS FLOWMETER

Zelio Relays RSL Slim Interface Plug-In Relays

Series IRV1000/2000/3000

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

5.0 MPa Maximum Supply Pressure. New. Stepless control of air pressure proportional to an electrical signal. Series ITVX CAT.

IRV Series. Vacuum Regulator. New RoHS. New and Improved. Series IRV10/20

SSL. Smart Valve Positioner.

Power Valve: Precision Regulator. High precision, large capacity relief regulator

Electro-Pneumatic Converter YT-940 SERIES

Bores: ø 10, 16, 20, 25, 32 mm

Air Differentail Pressure Switch

435 psi (3.0 MPa) Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. Maximum supply pressure. Set pressure range.

TECHNICAL INFORMATION

QPL... Pressure Switches. Siemens Building Technologies HVAC Products

Compact Manometer. Pressure measurements can easily be taken any time, anywhere.

TECHNICAL INFORMATION

TURQUOISE SWITCHES ABJ (BJ) SWITCHES

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Smart performance with innovative and ever-strong coil drive even under harsh working environments

SSR. Smart Valve Positioner.

Power Clamp Cylinder

ALF400 to 900, ALT-5/-9

Data Sheet. Vacuum generators

OPTIBAR P 1010 C Technical Datasheet

Compact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ

How to Order. Finger material. Carbon steel 1 Stainless steel. Dust cover material Chloroprene rubber (CR) Fluoro rubber (FKM) Silicon rubber (Si)

Level switches Series LD Vibrating fork level switch for liquids and solids

Thin pressure gauge. G401-W Series. Symbol Descriptions. A Connection A A. B Pressure display [MPa] P04 0 to 0.4MPa P10 0 to 1.

MECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET

Single and double acting, magnetic, self-centering Bores: ø 16, 20, 25, 32, 40 mm

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

Reliability and flexibility in a compact design

AMS 2710 PCB pressure sensor module with V output

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure

Air Gripper (2 Finger) (3 Finger)

WARNING. Work drop prevention check valves FPV series. Vacuum accessories. Safety handling of workpiece with several pads

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

RC 195 Receiver-Controller

Level switches Series LD Vibrating fork level switch for liquids and solids

NO: REL-149 PRODUCT: G8P Series PCB Power Relay DATE: November 2014 TYPE: Discontinuation Notice

Direct Operated Precision Regulator Modular Style. Standard Specifications

MPM280 Piezoresistive OEM Pressure Sensor

(1) Union Filter for positive and negative pressure (2) Filter size. (3) Tube dia. (4) Holder option : without Holder : with Holder

Position locking powerful chuck. CKL2-*-HC Series CKL2-40CS-HC CKL2-50CS-HC CKL2-63CS-HC CKL2-80CS-HC Compressed air to

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

EXH. Specifications. Descriptions. Min. working pressure MPa

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

e2c 20 - easy to connect

JUMO dtrans p30 Pressure Transmitter

Intrinsically safe solenoid valves on/off controls - ATEX certification

PRODUCT SPECIFICATION

Port size. Model Screw-in ZFA10 1/8 ZFA20 1/4 ZFB10 ZFB20 ZFB30 ZFB40 ZFC5 ZFC7

Pressure Measurement Single-range transmitters for general applications

MPM280 Piezoresistive OEM Pressure Sensor

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

Transcription:

Compact Pressure Switch Series 2 (For Vacuum)/ 2 (For Positive Pressure) For General Pneumatics Can be integrated with ZX or ZR ejector system. A Easy and simple wiring Connector type 77

Compact Pressure Switch Series 2/2 ow to Order Operating pressure range/ Setting pressure range Nil 0 to 1 MPa 0 to 100 kpa Piping specifications Single mounting R 1 /8 Note 1) T1 Single mounting NPTF 1 /8 Note 1) Note 1) (female) threaded. Positive pressure Vacuum 2 2 Piping specifications Single mounting R 1 /8 Note 2) T1 Single mounting NPTF 1 /8 Note 2) 0X W/suction filter (Mounting on ZX unit) 0XY W/suction filter (Mounting on ZX unit) M6 x 1 (Option) 0R Base mounting (Mounting on ZR unit) Note 2) Single mounting type: (female) threaded. Wiring specifications Nil Grommet type (ead wire: 0.6 m) Grommet type (ead wire: 3 m) C Connector type (ead wire: 0.6 m) C Connector type (ead wire: 3 m) CN Without connector Output specifications NPN open collector 55 PNP open collector With Connector/ow to Order Without lead wire (Connector 1 pc., 3 pcs.) ZS-10-A With lead wire ZS-10-5A- Note) When ordering switch with 5 m long lead wire, indicate both part numbers. Ex.) 2--CN 1 pc. ZS-10-5 A-50 1 pc. ead wire length Nil 30 50 0.6 m 3 m 5 m 780

Compact Pressure Switch Series 2/2 Specifications Rated pressure range/set pressure range Proof pressure Fluid Power supply voltage Current consumption Response time Repeatability Resistance Enclosure Operating temperature range Operating humidity range Vibration resistance Impact resistance Temperature characteristics(based on 25 C) Withstand voltage Insulation resistance Port size Mass ead wire Standard Model Grommet type Connector type Output Specifications Model Switch output Residual voltage Number of outputs ysteresis Indicator light Trimmer adjustment 2 For vacuum 0 to 1 kpa 2 For low pressure 0 to 100 kpa 500 kpa Air/Non-corrosive, non-flammable gas 2 For positive pressure 0 to 1 MPa 1.5 MPa 12 to 24 VDC ±10%, Ripple (P-P) 10% or less (With power supply polarity protection) 17 ma or less at 24 VDC 5 ms or less ±1% F.S. or less IP40 Operating: 0 to 60 C, Stored: 10 to 60 C (With no condensation and no freezing) Operating/Stored: 35 to 85%R (With no condensation) 10 to 500 z at whichever is smaller of 1.5 mm amplitude or 8 m/s 2 acceleration, in X, Y, Z directions for 2 hrs. each (De-energized) 80 m/s2 in X, Y, Z directions, 3 times each (De-energized) ±3% F.S. or less 1000 VAC for 1 min. (between live parts and case) 50 MΩ or more (at 500 VDC by megameter) between live parts and case : R 1/8,, 0X: With suction filter (For mounting on ZX unit) 0R: Base mount type (For mounting on ZR unit) 35 g (Including 0.6 m-ong lead wire) Oil-resistant vinyl cabtire code 3 cores, ø3.4, Cross section: 0.2 mm 2, Insulator O.D.: 1.1 mm eat-resistant vinyl electric wire, 3-wire, Cross section: 0.31 mm 2, Insulator O.D.: 1.55 mm Compliant with CE marking 55 NPN open collector 30V, 80 ma or less PNP open collector 80 ma or less 1 V or less (With load current of 80 ma) 1 3% F.S. or less (Fixed) ON: when output is ON (Red) 0 A 781

Series 2/2 Calibration Procedure Set the ON-pressure by the pressure setting trimmer. Turning clockwise can set the high pressure/high vacuum pressure. Pressure setting trimmer Indicator light ow to Use Connector 1. Attaching and detaching connectors When assembling the connector to the switch housing, push the connector straight onto the pins until the lever locks into the housing slot. When removing the connector from the switch housing, push the lever down to unlock it from the slot and then withdraw the connector straight off of the pin. ead wire 0.2 to 0.33 mm 2 Max. coating O.D. ø1.7 mm ook Connector DC polarity indicator ever Internal Circuit and Wiring Example - NPN open collector Main circuit Electric circuit diagram -55 PNP open collector Main circuit ED Red ED Red DC ( + ) Brown OUT Black + oad 12 to 24 VDC Max. 30 V, 80 ma DC ( ) Blue DC ( + ) Brown OUT Black DC ( ) Blue oad Max. 80 ma Electric circuit diagram + 12 to 24 VDC Set the possible min. pressure for adsorption confirmation. If setting the pressure lower than that, switch becomes ON in case that adsorption is not completely done. If setting the pressure higher than that, switch does not become ON even though it may absorb workpieces. igh vacuum Supply pressure Set point Atmospheric pressure 0 ysteresis Steady adsorption Unsteady adsorption Non adsorption Regarding the pressure setting Caution Observe the following precautions for setting the vacuum pressure: Use your fingertips to gently turn the screwdriver. Do not use a screwdriver with a large grip or with a tip that does not fit into the trimmer groove because this could strip the groove. ysteresis is the pressure difference between the ON and the OFF pressure of the output signal. The set pressure is the pressure selected to switch from OFF to ON condition. igh vacuum Set point igh pressure ysteresis ON OFF ook Core wire crimping area +O- ook ead wire Connector 0.2 to 0.33 mm 2 Max. coating O.D. ø1.7 mm DC polarity indicator ever Pin Slot ousing 2. Crimping of lead wires and sockets Strip 3.2 to 3.7 mm at the end of the lead wires, insert the ends of core wires evenly into the sockets, and then crimp with a crimping tool. When this is done, take care that the coverings of the lead wires do not enter the core wire crimping area. (Crimping tool: model no. DXT170-75-1) Covering retainer Core wire ead wire Covering 3.Attaching and detaching lead wires with sockets Attaching Insert the sockets into the square holes of the connector (with +, 0, indication), and continue to push the sockets all the way in until they lock by hooking into the seats in the connector. (When they are pushed in their hooks open and they are locked automatically.) Then confirm that they are locked by pulling lightly on the lead wires. Detaching To detach a socket from a connector, pull out the lead wire while pressing the socket s hook with a stick having a thin tip (about 1 mm). If the socket will be used again, first spread the hook outward. Connection example with a PC at common terminal Switch Main circuit of switch Filter case Caution DC ( + ) Brown OUT Black DC ( ) Blue + 12 to 24 VDC PC Input terminal COM 1. Do not use with thinner, carbon tetrachloride, chloroform, acetate, aniline, cyclohexane, trichloroethylene, sulfuric acid, lactic acid and watermiscible cutting fluid (alkaline). 2. Operate it away from direct sunlight. Caution Be sure to read before handling. Refer to front matters 58 and 5 for Safety Instructions and pages 687 to 61 for Pressure Switch Precautions. Atmospheric pressure 0 Connector ook ead wire 782

Compact Pressure Switch Series 2/2 Dimensions/With Suction Filter: 2-0X Grommet type: 2-0X - 7 35.6 Vacuum supply port Pneumatic circuit Vacuum pad connection port PV 10 8 Vacuum supply port 52 18 32 Connector type: 2-0X -C 10 17.6 2 x ø3.3 6.5 58 10.2 5.5 Vacuum pad connection port V A 7 35.6 Vacuum supply port Pneumatic circuit Vacuum pad connection port - O + 5 32 58 PV 6.5 10.2 8 18 V 10 10 17.6 5.5 Vacuum supply port 2 x ø3.3 Vacuum pad connection port 783

Series 2/2 Dimensions/Standard Type: 2- T1 Grommet type: 2- T1- Connector type: 2- T1-C 11 3 42 40 41 4 depth 5 : R 1/8 depth 5 : R 1/8 Dimensions/Base Mount Type: 2-0R Grommet type: 2-0R- Connector type: 2-0R-C 25 31 2 x M2.5 x 41 Mounting thread 25 31 2 x M2.5 x 41 Mounting thread 4.5 40 18 16 11 3 18 16 Gasket Vacuum supply port ø3.3 Gasket Vacuum supply port ø3.3 784

Compact Pressure Switch Series 2/2 Dimensions: 2 - T1 Grommet type: 2- T1- T1 Connector type: 2- -C 41 4 A depth 5 : R 1/8 depth 5 : R 1/8 785